Skip to main content

Microdetectors for medical physics

RYC2020-030247-I

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal de Promoción del Talento y su Empleabilidad en I+D+i
Subprogram Subprograma Estatal de Incorporación
Call Ramón y Cajal
Call year 2020
State Plan 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre AGENCIA ESTATAL CONSEJO SUPERIOR DE INVESTIGACIONES CIENTIFICAS (CSIC)

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

First Tests of an Opto-Electro-Mechanical System for 2D Dose Analysis in Low Energy Proton Irradiated Films

  • Mena Fernández, Silvia|||0000-0002-2800-2388
  • Karkour, Nabil|||0000-0002-1153-7706
  • Alaphilippe, V.
  • Crepin, D.
  • Jiménez-Ramos, M.C.|||0000-0001-7109-1040
  • García López, Javier|||0000-0003-4107-4383
  • Espino, J.M.
  • Pascual-Alvarez, D.
  • Riera-Llobet, Carla|||0000-0002-9037-1539
  • Muñoz-Berbel, Xavier|||0000-0002-6447-5756
  • Guirado, Gonzalo|||0000-0003-2128-7007
  • Gibelin, L.
  • Linget, D.
  • Guardiola, C.
This work presents a 2D dosimetry analysis with a new micro-opto-electro-mechanical system of radiochromic films irradiated with a low energy proton beam. The new system is based on a 5 X 10 matrix of photodetectors controlled by both an in-house electronic circuit and a graphical user interface, which allows direct optical density measurements. We have investigated the performance of this 2D readout system using Gafchromic EBT3 films. The results were compared with those obtained using a standard analysis method based on a flat-bed scanner, and the results showed the feasibility of this system for 2D dose map evaluation. To the best of the authors' knowledge, this is the first time that a two-dimensional micro-opto-electro-mechanical system has been used to analyze radiochromic films irradiated with low-energy protons. We intend to develop a portable 2D dosimetry tool that provides dose maps to speed up the reading of radiochromic films in radiotherapy.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

New opto-electro-mechanical sensor for two-dimensions dosimetry based on radiochromic films

  • Mena, Silvia
  • Karkour, Nabil
  • Alaphilippe, V
  • Botero, J P
  • Jiménez, Marcio Alfonso
  • Linget, Denis
  • Gibelin, L
  • Le Ven, V
  • Marquet, A
  • Mellouh, S
  • Josson, E
  • Benassou, W
  • Muñoz-Berbel, Xavier
  • Guirado, Gonzalo
  • Guardiola Salmerón, Consuelo
This work presents the validation of a new Opto‒Electro-Mechanical (MOEM) system consisting of a matrix of photodetectors for two-dimensional dosimetry evaluation with radiochromic films. The proposed system is based on a 5 × 10 matrix of photodetectors controlled by both in-house electronic circuit and graphical user interface, which enables optical measurements directly. We present the first tests performed in an X-ray machine and 137Cs source with that array by using Gafchromic EBT3 films. We obtained similar results than with a standard method (e.g. flat-bed scanner). Results were compared with Monte Carlo simulations and very good agreement was found. Results show the feasibility of using this system for dose evaluations. To the best of our knowledge, this is the first MOEM sensor for radiotherapy. Further developments are ongoing to create an advanced 16 × 16 LDRs system covering 1.6 cm × 1.6 cm with a 1 mm of spatial resolution. We point to develop a portable dosimetry tool delivering dose maps in real time to improve the clinical application of radiochromic films., Peer reviewed