Skip to main content

FUNCIONALIZACION DE PROTESIS RETICULARES DE POLIPROPILENO CON RECUBRIMIENTOS ANTISEPTICOS, DESTINADOS A LA PREVENCION DE LA INFECCION EN REPARACION HERNIARIA

SAF2017-89481-P

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal de Fomento de la Investigación Científica y Técnica de Excelencia
Subprogram Subprograma Estatal de Generación de Conocimiento
Call Proyectos de I+D (Excelencia / Generación de Conocimiento)
Call year 2017
State Plan 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre UNIVERSIDAD DE ALCALA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Pre-clinical assay of the tissue integration and mechanical adhesion of several types of cyanoacrylate adhesives in the fixation of lightweight polypropylene meshes for abdominal hernia repair

  • Pascual, G.
  • Mesa-Ciller, Claudia
  • Rodríguez, Marta
  • Pérez-Köhler, Bárbara
  • Gómez-Gil, V.
  • Fernández-Gutiérrez, Mar
  • San Román, Julio
  • Bellón, Juan M.
INTRODUCTION: Lightweight (LW) polypropylene (PP) meshes better adapt to host tissue, causing less fibrosis and inflammatory responses than high-density meshes. Mesh fixation using tissue adhesives (TA) that replace conventional sutures may improve the process of hernia repair and tissue trauma. This preclinical study compares the behavior of different cyanoacrylate-based adhesives in the fixation of LW-PP meshes for hernia repair. METHODS: Partial abdominal wall defects were repaired using LW-PP Optilene meshes in New Zealand rabbits. The following groups were established according to the mesh fixation method: Suture (control), Glubran 2 (n-butyl), Ifabond (n-hexyl), SafetySeal (n-butyl) and Evobond (n-octyl). At 14, 90 and 180 days after surgery, the recovered implants were examined to assess the host tissue integration, the macrophage response and the biomechanical strength. RESULTS: All the groups showed optimal host tissue incorporation regardless of the fixation procedure. Significantly increased levels of collagen 1 and collagen 3 gene expression (p<0.001) were observed at 14 days compared to the medium- and long-term durations, where the Suture and Glubran groups showed the highest expression of collagen 1. All the adhesives increased the macrophage reaction (p<0.001) compared to sutures at all implant times. Maximal macrophage response was observed in the short-term Glubran group (p<0.01) compared to the rest of the groups. Although SafetySeal and Evobond did not reach the biomechanical resistance of sutures at 14 days, all the adhesives did reach this level in the medium- to long-term periods, providing significantly higher resistance (p<0.05). CONCLUSIONS: All the cyanoacrylates, despite inducing a significantly increased macrophage response versus sutures, showed optimal host tissue integration and long-term mechanical behavior; thus, they might be good choices for LW-PP mesh hernia repairs., The study was supported by Grant “SAF2014-55022-P” and “SAF2017-89481-P” from the Spanish Ministry of Economy and Competitiveness., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Development of biocomposite polymeric systems loaded with antibacterial nanoparticles for the coating of polypropylene biomaterials

  • Fernández-Gutiérrez, Mar
  • Pérez-Köhler, Bárbara
  • Benito-Martínez, Selma
  • García-Moreno, Francisca
  • Pascual, Gemma
  • García-Fernández, Luis
  • Aguilar, María Rosa
  • Vázquez-Lasa, Blanca
  • Bellón, Juan Manuel
The development of a biocomposite polymeric system for the antibacterial coating of polypropylene mesh materials for hernia repair is reported. Coatings were constituted by a film of chitosan containing randomly dispersed poly(d,l-lactide-co-glycolide) (PLGA) nanoparticles loaded with chlorhexidine or rifampicin. The chlorhexidine-loaded system exhibited a burst release during the first day reaching the release of the loaded drug in three or four days, whereas rifampicin was gradually released for at least 11 days. Both antibacterial coated meshes were highly active against Staphylococcus aureus and Staphylococcus epidermidis (106 CFU/mL), displaying zones of inhibition that lasted for 7 days (chlorhexidine) or 14 days (rifampicin). Apparently, both systems inhibited bacterial growth in the surrounding environment, as well as avoided bacterial adhesion to the mesh surface. These polymeric coatings loaded with biodegradable nanoparticles containing antimicrobials effectively precluded bacterial colonization of the biomaterial. Both biocomposites showed adequate performance and thus could have potential application in the design of antimicrobial coatings for the prophylactic coating of polypropylene materials for hernia repair., The study was supported by Grants SAF2017-89481-P and MAT2017-84277-R from the Spanish Ministry of Science, Innovation and Universities. Financial support from the CIBER-BBN is acknowledged. The study was supported by Grants SAF2017-89481-P and MAT2017-84277-R from the Spanish Ministry of Science, Innovation and Universities. Financial support from the CIBER-BBN is acknowledged (CIBER-BBN Internal Collaborations 2018-2021: “Functionalization of polymer coatings using antimicrobial agents for prevention of mesh infection following hernia surgery” and “Polymeric nanoparticles for the treatment of bacterial diseases”)., Peer reviewed
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

New insights into the application of 3D-printing technology in hernia repair

  • Pérez Köhler, Bárbara|||0000-0002-5061-1526
  • Benito Martínez, Selma|||0000-0002-3118-0564
  • Gómez Gil, Verónica|||0000-0002-6642-5912
  • Rodríguez Mancheño, Marta
  • Pascual González, María Gemma|||0000-0002-1623-4384
  • Bellón Caneiro, Juan Manuel|||0000-0002-6071-5011
"Publicación presentada para sexenios", Abdominal hernia repair using prosthetic materials is among the surgical interventions most widely performed worldwide. These materials, or meshes, are implanted to close the hernial defect, reinforcing the abdominal muscles and reestablishing mechanical functionality of the wall. Meshes for hernia repair are made of synthetic or biological materials exhibiting multiple shapes and configurations. Despite the myriad of devices currently marketed, the search for the ideal mesh continues as, thus far, no device offers optimal tissue repair and restored mechanical performance while minimizing postoperative complications. Additive manufacturing, or 3D-printing, has great potential for biomedical applications. Over the years, different biomaterials with advanced features have been successfully manufactured via 3D-printing for the repair of hard and soft tissues. This technological improvement is of high clinical relevance and paves the way to produce next-generation devices tailored to suit each individual patient. This review focuses on the state of the art and applications of 3D-printing technology for the manufacture of synthetic meshes. We highlight the latest approaches aimed at developing improved bioactive materials (e.g., optimizing antibacterial performance, drug release, or device opacity for contrast imaging). Challenges, limitations, and future perspectives are discussed, offering a comprehensive scenario for the applicability of 3D-printing in hernia repair., Financial support from the CIBER-BBN
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Development of biocomposite polymeric systems loaded with antibacterial nanoparticles for the coating of polypropylene biomaterials

  • Fernández Gutiérrez, Mar
  • Pérez Köhler, Bárbara|||0000-0002-5061-1526
  • Benito Martínez, Selma|||0000-0002-3118-0564
  • García-Moreno Nisa, Francisca|||0000-0001-5360-0577
  • Pascual González, María Gemma|||0000-0002-1623-4384
  • García Fernández, Luis
  • Aguilar, María Rosa
  • Vázquez Lasa, Blanca
  • Bellón Caneiro, Juan Manuel|||0000-0002-6071-5011
"Publicación presentada para sexenios", The development of a biocomposite polymeric system for the antibacterial coating of polypropylene mesh materials for hernia repair is reported. Coatings were constituted by a film of chitosan containing randomly dispersed poly(d,l-lactide-co-glycolide) (PLGA) nanoparticles loaded with chlorhexidine or rifampicin. The chlorhexidine-loaded system exhibited a burst release during the first day reaching the release of the loaded drug in three or four days, whereas rifampicin was gradually released for at least 11 days. Both antibacterial coated meshes were highly active against Staphylococcus aureus and Staphylococcus epidermidis (106 CFU/mL), displaying zones of inhibition that lasted for 7 days (chlorhexidine) or 14 days (rifampicin). Apparently, both systems inhibited bacterial growth in the surrounding environment, as well as avoided bacterial adhesion to the mesh surface. These polymeric coatings loaded with biodegradable nanoparticles containing antimicrobials e_ectively precluded bacterial colonization of the biomaterial. Both biocomposites showed adequate performance and thus could have potential application in the design of antimicrobial coatings for the prophylactic coating of polypropylene materials for hernia repair., Agencia Estatal de Investigación
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Self-adhesive hydrogel meshes reduce tissue incorporation and mechanical behavior versus microgrips self-fixation: a preclinical study.

  • Benito Martínez, Selma|||0000-0002-3118-0564
  • Rodríguez Mancheño, Marta
  • García-Moreno Nisa, Francisca|||0000-0001-5360-0577
  • Pérez Köhler, Bárbara|||0000-0002-5061-1526
  • Peña, Estefanía
  • Calvo Calzada, Begoña
  • Pascual González, María Gemma|||0000-0002-1623-4384
  • Bellón Caneiro, Juan Manuel|||0000-0002-6071-5011
Purpose: Atraumatic mesh fixation for abdominal hernia repair has been developed to avoid the disadvantages of classical fixation with sutures, which is considered a cause of chronic pain and discomfort. This study was designed to analyze, in the short and medium term, the biological and mechanical behavior of two self-fixing meshes compared to that of a polypropylene (PP) mesh fixed with a cyanoacrylate (CA) tissue adhesive. Methods: Partial abdominal wall defects (6 × 4 cm) were created in New Zealand rabbits (n = 36) and repaired using a selfadhesive hydrogel mesh (Adhesix?), a self-gripping mesh (ProGrip?) or a PP mesh fixed with CA (Surgipro? CA). After 14 and 90 days, the host tissue incorporation, macrophage response and biomechanical strength were examined. Results: At 14 and 90 days, the ProGrip and Surgipro CA meshes showed good host tissue incorporation; however, the Adhesix implants presented poor integration, seroma formation and a higher degree of shrinkage. The Adhesix hydrogel was completely reabsorbed at 14 days, whereas ProGrip microhooks were observed at all study times. The macrophage response was higher in the ProGrip and Surgipro CA groups at 14 and 90 days, respectively, and decreased over time. At 90 days, the ProGrip implants showed the highest tensile strength values and the Adhesix implants showed the highest failure stretch. Conclusion: Meshes with mechanical microgrip self-fixation (ProGrip) show better biological and mechanical behavior than those with adhesive hydrogel (Adhesix) in a preclinical model of abdominal hernia repair in rabbits., Agencia Estatal de Investigación