Publication Artículo científico (JournalArticle)

Use of MOSFET dosimeters to validate Monte Carlo radiation treatment calculation in an anthropomorphic phantom

  • Juste-Vidal, Belen-Jeanne|||0000-0003-1978-3765
  • Miró Herrero, Rafael|||0000-0003-1012-0869
  • Verdú Martín, Gumersindo Jesús|||0000-0001-5098-080X
  • Abella Aranda, Vicente
  • Santos Serra, Agustín
Radiation therapy treatment planning based on Monte Carlo simulation provide a very accurate dose calculation compared to deterministic systems. Nowadays, Metal-Oxide-Semiconductor Field Effect Transistor (MOSFET) dosimeters are increasingly utilized in radiation therapy to verify the received dose by patients. In the present work, we have used the MCNP6 (Monte Carlo N-Particle transport code) to simulate the irradiation of an anthropomorphic phantom (RANDO) with a medical linear accelerator. The detailed model of the Elekta Precise multileaf collimator using a 6 MeV photon beam was designed and validated by means of different beam sizes and shapes in previous works. To include in the simulation the RANDO phantom geometry a set of Computer Tomography images of the phantom was obtained and formatted. The slices are input in PLUNC software, which performs the segmentation by defining anatomical structures and a Matlab algorithm writes the phantom information in MCNP6 input deck format. The simulation was verified and therefore the phantom model and irradiation was validated throughout the comparison of High-Sensitivity MOSFET dosimeter (Best medical Canada) measurements in different points inside the phantom with simulation results. On-line Wireless MOSFET provide dose estimation in the extremely thin sensitive volume, so a meticulous and accurate validation has been performed. The comparison show good agreement between the MOSFET measurements and the Monte Carlo calculations, confirming the validity of the developed procedure to include patients CT in simulations and approving the use of Monte Carlo simulations as an accurate therapy treatment plan., The authors wish to thank the Consorci Hospitalari Provincial de Castello (Spain) for their kind support in doing this work. This work was partially supported through "Programa para la innovacion e incentivacion" of the Universitat Politecnica de Valencia "INNOVA 2012". This work has been done under the project: Monte Carlo Treatment Planning System: Software for the high precision dosimetry calculations in radiotherapy (SP20120824).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Monte Carlo calculation of the spatial response (Modulated Transfer Function) of a scintillation flat panel and comparison with experimental results

  • Juste-Vidal, Belen-Jeanne|||0000-0003-1978-3765
  • Miró Herrero, Rafael|||0000-0003-1012-0869
  • Verdú Martín, Gumersindo Jesús|||0000-0001-5098-080X
  • Monasor, P.
Phosphor screens are commonly used in many X-ray imaging applications. The design and optimization of these detectors can be achieved using Monte Carlo codes to simulate radiation transport in scintillation materials and to improve the spatial response. This work presents an exhaustive procedure to measure the spatial resolution of a scintillation flat panel image and to evaluate the agreement with data obtained by simulation. To evaluate the spatial response we have used the Modulated Transfer Function (MTF) parameter. According to this, we have obtained the Line Spread Function (LSF) of the system since the Fourier Transform (FT) of the LSF gives the MTF. The experimental images were carried out using a medical X-ray tube (Toshiba E7299X) and a flat panel (Hammamatsu C9312SK). Measurements were based on the slit methodology experimental implementation, which measures the response of the system to a line. LSF measurements have been performed using a 0.2 mm wide lead slit superimposed over the flat panel. The detector screen was modelled with MCNP (version 6) Monte Carlo simulation code in order to analyze the effect of the acquisition setup configuration and to compare the response of scintillator screens with the experimental results. MCNP6 offers the possibility of studying the optical physics parameters (optical scattering and absorption coefficients) that occur in the phosphor screen. The study has been tested for different X-ray tube voltages, from 100 to 140 kV. An acceptable convergence between the MTF results obtained with MCNP6 and the experimental measurements have been obtained., This work was partially supported through "Programa para la innovacion e incentivacion" of the Polytechnic University of Valencia "INNOVA 2012". This work has been done under the project: Monte Carlo Treatment Planning System: Software for the high precision dosimetry calculations in radiotherapy (SP20120824).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

VARIAN CLINAC 6 MeV Photon Spectra Unfolding using a Monte Carlo Meshed Model

  • Morató-Rafet, Sergio
  • Juste-Vidal, Belen-Jeanne|||0000-0003-1978-3765
  • Miró Herrero, Rafael|||0000-0003-1012-0869
  • Verdú Martín, Gumersindo Jesús|||0000-0001-5098-080X
[EN] Energy spectrum is the best descriptive function to determine photon beam quality of a Medical Linear Accelerator (LinAc). The use of realistic photon spectra in Monte Carlo simulations has a great importance to obtain precise dose calculations in Radiotherapy Treatment Planning (RTP). Reconstruction of photon spectra emitted by medical accelerators from measured depth dose distributions in a water cube is an important tool for commissioning a Monte Carlo treatment planning system. Regarding this, the reconstruction problem is an inverse radiation transport function which is ill conditioned and its solution may become unstable due to small perturbations in the input data. This paper presents a more stable spectral reconstruction method which can be used to provide an independent confirmation of source models for a given machine without any prior knowledge of the spectral distribution. Monte Carlo models used in this work are built with unstructured meshes to simulate with realism the linear accelerator head geometry., Ha recibido financiación de DESARROLLO E IMPLEMENTACION DE UN SISTEMA DE PLANIFICACION RADIOTERAPÉUTICA (TELETERAPIA Y BRAQUITERAPIA) BASADO EN EL MÉTODO MONTECARLO PARA EL HUPLAFE (UNIVERSIDAD POLITECNICA DE VALENCIA), DESARROLLO Y VALIDACION EXPERIMENTAL DE UN SISTEMA DE PLANIFICACION DE TRATAMIENTOS RADIOTERAPEUTICOS UTILIZANDO TECNICAS DE MONTE CARLO (UNIVERSIDAD POLITECNICA DE VALENCIA), Dosimetría in vivo en radioterapia sin filtro aplanador (FFF) (UNIVERSIDAD POLITECNICA DE VALENCIA), MONTE CARLO TREATMENT PLANNING SYSTEM: SOFTWARE PARA EL CALCULO DOSIMETRICO DE ALTA PRECISION EN RADIOTERAPIA. (UNIVERSIDAD POLITECNICA DE VALENCIA) y SISTEMA DE PLANIFICACION DE TRATAMIENTOS EN RADIOTERAPIA BASADO EN EL METODO DE MOTE CARLO Y EL PROCESADO 3D DE IMAGENES MEDICAS (GENERALITAT VALENCIANA)