RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication
Artículo científico (JournalArticle)
Test Strips Based on Gated Nanoporous Anodic Alumina for the Rapid and Accurate Detection of Pseudomonas aeruginosa in Clinical Samples
[EN] Pseudomonas aeruginosa is a high-priority pathogen responsible for up to 23% of infections in intensive care units, yet current diagnostic methods remain hindered by multiday delays or high technical complexity. In this study, we report a rapid and highly sensitive biosensor based on nanoporous anodic alumina (NAA) capped with a specific oligonucleotide molecular gate targeting the phzA2 gene. The S3 biosensor achieved a limit of detection (LOD) of 0.153 ng mu L-1 for genomic DNA and an exceptional 28 CFU mL(-1) for direct bacterial detection without the need for prior DNA extraction. Validation in 63 clinical urine samples demonstrated a sensitivity of 91.67% and a specificity of 94.87% (AUC: 0.961, p-value < 0.0001). Furthermore, the sensor was integrated into Lateral Flow Assay (LFA), enabling the discrimination of positive and negative clinical samples in only 1 min with 100% specificity and 90.9% sensitivity. These results, combined with a one-year stability at 4 degrees C, position this gated-nanodevice as a robust and low-cost tool for Point-of-care (POC) diagnosis of P. aeruginosa infections., This research was funded by projects PID2024-155683OB-C41, PID2021-126304OB-C41, PID2021-122875OB-I00, and TED2021-132114B-100, supported by MCIN/AEI/10.13039/501100011033, the European Regional Development Fund, the European Union (NextGenerationEU/PRTR), and the Generalitat Valenciana (CIPROM/2021/007). This study is part of the Advanced Materials programme (MFA/2022/053) and was supported by MCIN with funding from the European Union's NextGenerationEU (PRTR-C17. I1) and by the Generalitat Valenciana. The project was also funded by Ayuntamiento de Valencia (SPI2024-096) and Instituto de Salud Carlos III (PI24/01239), cofunded by the European Union. In the same way, A.T. would like to thank the INVESTIGO program of the Ministry of Innovation, Universities, Research, and Digital Society of the Valencian Community for offering this research opportunity (INVEST/2023/443). To conclude, A.T. is grateful to the Asociacion Espanola Contra el Cancer for her 2024 predoctoral fellowship (PRDVA246577TORR (2024-0590-1)), which enabled this research. E.C. thanks the Instituto de Salud Carlos III (Miguel Servet 2023 CP23/00086), cofounded by the European Union. The authors thank Electron Microscopy Service at UPV for support. Funding for open access charge: CRUE-Universitat Politecnica de Valencia.
Project:
Agencia Estatal de Investigación / Plan Estatal de Investigación Científica y Técnica y de Innovación 2021-2023 PID2021-126304OB-C41
,
Agencia Estatal de Investigación / Plan Estatal de Investigación Científica y Técnica y de Innovación 2021-2023 PID2021-122875OB-I00
,
Ajuntament de València SPI2024-096
,
Generalitat Valenciana INVEST/2023/443
,
Generalitat Valenciana MFA/2022/053
,
Instituto de Salud Carlos III CP23/00086
,
Generalitat Valenciana CIPROM/2021/007
,
Instituto de Salud Carlos III PI24/01239
,
Asociación Española Contra el Cáncer PRDVA246577TORR
,
Agencia Estatal de Investigación PID2024-155683OB-C41
,
Ministerio de Ciencia e Innovación TED2021-132114B-100