Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 20
Encontrada(s) 1 página(s)

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

On studying the interaction between different stent models and rabbit tracheal tissue: numerical, endoscopic and histological comparison

  • Chaure, J
  • Serrano, C
  • Fernández-Parra, R
  • Peña, E
  • Lostalé, F
  • Gregorio, MA
  • Martínez, MA
  • Malvè, M
Stenting technique is employed worldwide for treating atherosclerotic vessel and tracheal stenosis. Both diseases can be treated by means of metallic stents which present advantages but are affected by the main problem of restenosis of the stented area. In this study we have built a rabbit trachea numerical model and we have analyzed it before and after insertion and opening of two types of commercial stent: a Zilver® FlexTM Stent and a WallStentTM. In experimental parallel work, two types of stent were implanted in 30 New Zealand rabbits divided in two groups of 10 animals corresponding to each stent type and a third group made up of 10 animals without stent. The tracheal wall response was assessed by means of computerized tomography by endoscopy, macroscopic findings and histopathological study 90 days after stent deployment. Three idealized trachea models, one model for each group, were created in order to perform the computational study. The animal model was used to validate the numerical findings and to attempt to find qualitative correlations between numerical and experimental results. Experimental findings such as inflammation, granuloma and abnormal tissue growth, assessed from histomorphometric analyses were compared with derived numerical parameters such as wall shear stress (WSS) and maximum principal stress. The direct comparison of these parameters and the biological response supports the hypothesis that WSS and tensile stresses may lead to a greater tracheal epithelium response within the stented region, with the latter seeming to have the dominant role. This study may be helpful for improving stent design and demonstrates the feasibility offered by in-silico investigated tracheal structural and fluid dynamics.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Effect of diet and age on arterial stiffening due to atherosclerosis in ApoE-/- mice

  • Cilla, M.
  • Pérez, M.M.
  • Peña, E.
  • Martínez, M.A.
This work analyzes the progressive stiffening of the aorta due to atherosclerosis development of both ApoE-/- and C57BL/6J mice fed on a Western (n = 5) and a normal (n = 5) chow diet for the ApoE-/- group and on a normal chow diet (n = 5) for the C57BL/6J group. Sets of 5 animals from the three groups were killed after 10, 20, 30 and 40 weeks on their respective diets (corresponding to 17, 27, 37 and 47 weeks of age). Mechanical properties (inflation test and axial residual stress measurements) and histological properties were compared for both strains, ApoE-/- on the hyper-lipidic diet and both ApoE-/- and C57BL/6J on the normal diet, after the same period and after different periods of diet. The results indicated that the aorta stiffness in the ApoE-/- and C57BL/6J mice under normal diet remained approximately constant irrespective of their age. However, the arterial stiffness in the ApoE-/- on the hyper-lipidic diet increased over time. Statistical differences were found between the group after 10 weeks and the groups after 30 and 40 weeks of a hyper-lipidic diet. Comparing the hyper-lipidic and normal diet mice, statistical differences were also found between both diets in all cases after 40 weeks of diet, frequently after 30 weeks, and in some cases after 20 weeks. The early stages of lesion corresponded to the first 2 weeks of diet. Advanced lesions were found at 30 weeks and, finally, the aorta was completely damaged after 40 weeks of diet. In conclusion, we found substantial changes in the mechanical properties of the aorta walls of the ApoE-/- mice fed with the hyper-lipidic diet compared to the normal chow diet groups for both the ApoE-/- and C57BL/6J groups. These findings could serve as a reference for the study of changes in the arterial wall properties in cases of atherosclerosis.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

A Manifold Learning Approach to Data-Driven Computational Elasticity and Inelasticity

  • Ibañez, R.
  • Abisset-Chavanne, E.
  • Aguado, J.V.
  • Gonzalez, D.
  • Cueto, E.
  • Chinesta, F.
Standard simulation in classical mechanics is based on the use of two very different types of equations. The first one, of axiomatic character, is related to balance laws (momentum, mass, energy, ...), whereas the second one consists of models that scientists have extracted from collected, natural or synthetic data. Even if one can be confident on the first type of equations, the second one contains modeling errors. Moreover, this second type of equations remains too particular and often fails in describing new experimental results. The vast majority of existing models lack of generality, and therefore must be constantly adapted or enriched to describe new experimental findings. In this work we propose a new method, able to directly link data to computers in order to perform numerical simulations. These simulations will employ axiomatic, universal laws while minimizing the need of explicit, often phenomenological, models. This technique is based on the use of manifold learning methodologies, that allow to extract the relevant information from large experimental datasets.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

A rabbit model of Acanthamoeba keratitis: Use of infected soft contact lenses after corneal epithelium debridement with a diamond burr

  • Ortillés, Á.
  • Goñi, P.
  • Rubio, E.
  • Sierra, M.
  • Gámez, E.
  • Fernández, M.T.
  • Benito, M.
  • Cristóbal, J.Á.
  • Calvo, B.
PURPOSE. To develop a rabbit model of Acanthamoeba keratitis (AK) as the best method to reproduce the natural course of this disease. METHODS. To induce AK, infected contact lenses (1000 amoebae/mm2, 90% trophozoites) were placed over the previously debrided corneal surface, in combination with a temporary tarsorrhaphy. Environmental and clinical strains of Acanthamoeba spp. (genotype T4) were used. Three groups (1L, n = 32; 2L–21d, n = 5; 2L–3d, n = 23) were established according to the number of contact lenses used (1L, 1 lens; 2L–21d and 2L–3d, 2 lenses) and the placement day of these (1L, day 1; 2L–21d, days 1 and 21; 2L–3d, days 1 and 3). The infection was quantified by a clinical score system and confirmed using corneal cytology and culture, polymerase chain reaction and histopathologic analysis. RESULTS. The infection rate obtained was high (1L, 87.5%; 2L–21d, 100%; 2L–3d, 82.6%), although no clinical signs were observed in the 50% of the infected animals in group 1L. Among groups, group 2L–3d showed more cases of moderate and severe infection. Among strains, no statistically significant differences were found in the infection rate. In the control eyes, cross infection was confirmed when a sterile contact lens was placed in the previously debrided corneas but not if the eye remained intact. CONCLUSIONS. The combination of two infected contact lenses after corneal debridement seems to be an alternative model, clinically and histopathologically similar to its human counterpart, to induce the different AK stages and reproduce the course of the disease in rabbits.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Towards the modelling of ageing and atherosclerosis effects in ApoE-/- mice aortic tissue

  • Waffenschmidt, T.
  • Cilla, M.
  • Sáez, P.
  • Pérez, M.M.
  • Martínez, M.A.
  • Menzel, A.
  • Peña, E.
The goal of this work consists in a quantitative analysis and constitutive modelling of ageing processes associated to plaque formation in mice arteries. Reliable information on the characteristic evolution of pressure–stretch curves due to the ageing effects is extracted from previous inflation test experiments. Furthermore, characteristic age-dependent material parameters are identified on the basis of a continuum-mechanics-based parameter optimisation technique. The results indicate that the aorta-stiffness of the healthy control mice remains basically constant irrespective of the diet-time and age. In contrast, significant differences exist within the material response and in consequence within the material parameters between the ApoE-/- and the control mice as well as for the different locations over the aorta which is underlined by our experimental observations. With regard to the temporal evolution of the material parameters, we observe that the material parameters for the ApoE-/- mice aortas exhibit a saturation-type increase with respect to age.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Predicting muscle fatigue: a response surface approximation based on proper generalized decomposition technique

  • Sierra, M.
  • Grasa, J.
  • Muñoz, M. J.
  • Miana-Mena, F.
  • González, D.
A novel technique is proposed to predict force reduction in skeletal muscle due to fatigue under the influence of electrical stimulus parameters and muscle physiological characteristics. Twelve New Zealand white rabbits were divided in four groups ((Formula presented.)) to obtain the active force evolution of in vitro Extensor Digitorum Longus muscles for an hour of repeated contractions under different electrical stimulation patterns. Left and right muscles were tested, and a total of 24 samples were used to construct a response surface based in the proper generalized decomposition. After the response surface development, one additional rabbit was used to check the predictive potential of the technique. This multidimensional surface takes into account not only the decay of the maximum repeated peak force, but also the shape evolution of each contraction, muscle weight, electrical input signal and stimulation protocol. This new approach of the fatigue simulation challenge allows to predict, inside the multispace surface generated, the muscle response considering other stimulation patterns, different tissue weight, etc.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Contribución de congreso (ConferenceOutput)

The role of purkinje automaticity as an arrhythmia mechanism in hyperkalaemia

  • Monasterio, Violeta
  • Carro, Jesús
  • Pueyo, Esther
  • Rodríguez, José F.
The pacemaker activity of Purkinje (PK) cells is usually suppressed by the sino-atrial (SA) node. Under abnormal conditions, PK cells may produce ectopic focal activity leading to tachycardia and fibrillation. This computational modelling work illustrates the potential role of PK automaticity as an arrhythmia mechanism in hyperkalaemia. First, we investigated the automaticity of isolated PK cells under hyperkalaemic conditions. Second, the potential consequences of altered PK automaticity were explored in a 1-D model of a terminal PK fibre running through a hyperkalaemic zone. Hyperkalaemia was found to accelerate the autorhythmic period of isolated PK cells with respect to control. For extracellular potassium levels = 7.2 mM, spontaneous action potentials (APs) appeared in the PK fibre, leading to conduction disturbances and complex combinations of spontaneous and stimulation-driven APs.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Computational simulation of scleral buckling surgery for rhegmatogenous retinal detachment: On the effect of the band size on the myopization

  • Lanchares, E.
  • Buey, M.A.D.
  • Cristóbal, J.A.
  • Calvo, B.
  • Ascaso, F.J.
  • Malvè, M.
A finite element model (FE) of the eye including cornea, sclera, crystalline lens, and ciliary body was created to analyze the influence of the silicone encircling bandwidth and the tightness degree on the myopia induced by scleral buckling (SB) procedure for rhegmatogenous retinal detachment. Intraocular pressure (IOP) was applied to the reference geometry of the FE model and then SB surgery was simulated with encircling bandwidths of 1, 2, and 2.5 mm. Different levels of tightening and three values of IOP were applied. The anterior segment resulted as unaffected by the surgery. The highest value of Cauchy stress appeared in the surroundings of the implant, whereas no increment of stress was observed either in anterior segment or in the optic nerve head. The initial IOP did not appear to play any role in the induced myopia. The wider the band, the greater the induced myopia: 0.44, 0.88, and 1.07 diopters (D) for the 1, 2, and 2.5 mm bandwidth, respectively. Therefore, patients become more myopic with a wider encircling element. The proposed simulations allow determining the effect of the bandwidth or the tightness degree on the axial lengthening, thus predicting the myopic increment caused by the encircling surgery.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Reseña (Review)

Limitations in electrophysiological model development and validation caused by differences between simulations and experimental protocols

  • Carro, J.
  • Rodríguez-Matas, J.F.
  • Monasterio, V.
  • Pueyo, E.
Models of ion channel dynamics are usually built by fitting isolated cell experimental values of individual parameters while neglecting the interaction between them. Another shortcoming regards the estimation of ionic current conductances, which is often based on quantification of Action Potential (AP)-derived markers. Although this procedure reduces the uncertainty in the calculation of conductances, many studies evaluate electrophysiological AP-derived markers from single cell simulations, whereas experimental measurements are obtained from tissue preparations. In this work, we explore the limitations of these approaches to estimate ion channel dynamics and maximum current conductances and how they could be overcome by using multiscale simulations of experimental protocols. Four human ventricular cell models, namely ten Tusscher and Panfilov (2006), Grandi et al. (2010), O''Hara et al. (2011), and Carro et al. (2011), were used. Two problems involving scales from ion channels to tissue were investigated: 1) characterization of L-type calcium voltage-dependent inactivation ICa, L; 2) identification of major ionic conductance contributors to steady-state AP markers, including APD90, APD75, APD50, APD25, Triangulation and maximal and minimal values of V and dV/dt during the AP (Vmax, Vmin, dV/dtmax, dV/dtmin). Our results show that: 1) ICa, L inactivation characteristics differed significantly when calculated from model equations and from simulations reproducing the experimental protocols. 2) Large differences were found in the ionic currents contributors to APD25, Triangulation, Vmax, dV/dtmax and dV/dtmin between single cells and 1D-tissue. When proposing any new model formulation, or evaluating an existing model, consistency between simulated and experimental data should be verified considering all involved effects and scales.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Haptic simulation of tissue tearing during surgery

  • Quesada, Carlos
  • Alfaro, Icíar
  • González, David
  • Chinesta, Francisco
  • Cueto, Elías
We present a method for the real-time, interactive simulation of tissue tearing during laparoscopic surgery. The method is designed to work at haptic feedback rates (i.e., around 1kHz). Tissue tearing is simulated under the general framework of continuum damage mechanics. The problem is stated as a general, multidimensional parametric problem, which is solved by means of Proper Generalized Decomposition (PGD) methods. One of the main novelties is the reduction of history-dependent problems, such as damage mechanics, by resorting to an approach in which a reduced-order field of initial damage values is considered as a parameter of the formulation. We focus on the laparoscopic cholecystectomy procedure as a general example of the performance of the method.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Local proper generalized decomposition

  • Badías, A.
  • González, D.
  • Alfaro, I.
  • Chinesta, F.
  • Cueto, E.
Local model order reduction methods provide better results than global ones to problems with intricate manifold solution structure. A posteriori methods (e.g. Proper Orthogonal Decomposition) have been many times applied locally, but a priori methods (e.g. Proper Generalized Decomposition) have the difficulty of determining the manifold structure of the solution in a previous way. We propose three strategies for estimating the appropriate size of the local sub-domains where afterwards local PGD (l-PGD) is applied. It can be seen as a sort of a priori manifold learning or non-linear dimensionality reduction technique. Finally, three examples support the work.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Effect of cryopreserved amniotic membrane on the mechanical properties of skeletal muscle after strabismus surgery in rabbits

  • Sierra, M.
  • Ortillés, A.
  • Miana-Mena, F.J.
  • Grasa, J.
  • Calvo, B.
Purpose: To study the functional recovery of the superior rectus muscle (SRM) after its partial resection in a rabbit model with and without cryopreserved amniotic membrane (AM). Material and methods: Resection of the right and left SRMs of 30 rabbits was performed. On the left eyes, a single sheet of equine cryopreserved AM was placed covering the muscle edge sutured. Active and passive mechanical properties of muscles operated with and without AM were monitored over time at 30 (n = 10), 60 (n = 10), and 90 (n = 10) days after surgery. Muscle samples were extracted and electrically stimulated to register the force exerted by the samples, characterizing its active behavior. They were, then, subjected to stretching test to obtain its resistance to deformation, known as passive behavior. Moreover, right and left eyes of a control group (n = 5) were equally subjected to active and passive tests to characterize the physiological behavior of SRM muscles. Results: On active function examination, statistically significant differences were documented between the following: control vs AM and no AM at 30 days (p = 0.002 and p = 0.04, respectively). All other comparisons were insignificant (p > 0.05). On passive function analysis, significant differences were only found between control vs. no AM at 30 days (p = 0.004) and between AM vs. no AM at 30 days (p = 0.002). Indeed, muscle operated without AM did not recover a normal passive function until 60 days after surgery. Conclusion: Cryopreserved AM is effective in accelerating recovery of SRM passive function in rabbits. Nevertheless, AM produced no significant effect on recovery of SRM active function.¿
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Tunable injectable alginate-based hydrogel for cell therapy in Type 1 Diabetes Mellitus

  • Espona-Noguera, A.
  • Ciriza, J.
  • Cañibano-Hernández, A.
  • Fernandez, L.
  • Ochoa, I.
  • Saenz del Burgo, L.
  • Pedraz, J.L.
Islet transplantation has the potential of reestablishing naturally-regulated insulin production in Type 1 diabetic patients. Nevertheless, this procedure is limited due to the low islet survival after transplantation and the lifelong immunosuppression to avoid rejection. Islet embedding within a biocompatible matrix provides mechanical protection and a physical barrier against the immune system thus, increasing islet survival. Alginate is the preferred biomaterial used for embedding insulin-producing cells because of its biocompatibility, low toxicity and ease of gelation. However, alginate gelation is poorly controlled, affecting its physicochemical properties as an injectable biomaterial. Including different concentrations of the phosphate salt Na2HPO4 in alginate hydrogels, we can modulate their gelation time, tuning their physicochemical properties like stiffness and porosity while maintaining an appropriate injectability. Moreover, these hydrogels showed good biocompatibility when embedding a rat insulinoma cell line, especially at low Na2HPO4 concentrations, indicating that these hydrogels have potential as injectable biomaterials for Type 1 Diabetes Mellitus treatment.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Over length quantification of the multiaxial mechanical properties of the ascending, descending and abdominal aorta using Digital Image Correlation

  • Peña, Juan A.
  • Corral, Victoria
  • Martínez, Miguel A.
  • Peña, Estefanía
In this paper, we hypothesize that the biaxial mechanical properties of the aorta may be dependent on arterial location. To demonstrate any possible position-related difference, our study analyzed and compared the biaxial mechanical properties of the ascending thoracic aorta, descending thoracic aorta and infrarenal abdominal aorta stemming from the same porcine subjects, and reported values of constitutive parameters for well-known strain energy functions, showing how these mechanical properties are affected by location along the aorta. When comparing ascending thoracic aorta, descending thoracic aorta and infrarenal abdominal aorta, abdominal tissues were found to be stiffer and highly anisotropic. We found that the aorta changed from a more isotropic to a more anisotropic tissue and became progressively less compliant and stiffer with the distance to the heart. We observed substantial differences in the anisotropy parameter between aortic samples where abdominal samples were more anisotropic and nonlinear than the thoracic samples. The phenomenological model was not able to capture the passive biaxial properties of each specific porcine aorta over a wide range of biaxial deformations, showing the best prediction root mean square error e=0.2621 for ascending thoracic samples and, especially, the worst for the infrarenal abdominal samples e=0.3780. The micro-structured model with Bingham orientation density function was able to better predict biaxial deformations (e=0.1372 for ascending thoracic aorta samples). The root mean square error of the micro-structural model and the micro-structured model with von Mises orientation density function were similar for all positions.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Template-based methodology for the simulation of intracorneal segment ring implantation in human corneas

  • Flecha-Lescún, J.
  • Calvo, B.
  • Zurita, J.
  • Ariza-Gracia, M.Á.
Keratoconus is an idiopathic, non-inflammatory and degenerative corneal disease characterised by a loss of the organisation in the corneal collagen fibrils. As a result, keratoconic corneas present a localised thinning and conical protrusion with irregular astigmatism and high myopia that worsen visual acuity. Intracorneal ring segments (ICRSs) are used in clinic to regularise the corneal surface and to prevent the disease from progressing. Unfortunately, the post-surgical effect of the ICRS is not explicitly accounted beforehand. Traditional treatments rely on population-based nomograms and the experience of the surgeon. In this vein, in silico models could be a clinical aid tool for clinicians to plan the intervention, or to test the post-surgical impact of different clinical scenarios. A semi-automatic computational methodology is presented in order to simulate the ICRS surgical operation and to predict the post-surgical optical outcomes. For the sake of simplicity, circular cross section rings, average corneas and an isotropic hyperelastic material are used. To determine whether the model behaves physiologically and to carry out a sensitivity analysis, a (Formula presented.) full-factorial analysis is carried out. In particular, how the stromal depth insertion, horizontal distance of ring insertion (hDRI) and diameter of the ring’s cross section ((Formula presented.)) are impacting in the spherical and cylindrical power of the cornea is analysed. Afterwards, the kinematics, mechanics and optics of keratoconic corneas after the ICRS insertion are analysed. Based on the parametric study, we can conclude that our model follows clinical trends previously reported. In particular and although there is an improvement in defocus, all corneas presented a change in their optical aberrations. The stromal depth insertion is the parameter that affects the corneal optics the most, whereas hDRI and (Formula presented.) are less important. Not only that, but it is almost impossible to achieve an optimal trade-off between spherical and cylindrical correction. Regarding the mechanical behaviour, inserting the rings at 65% depth or above will cause the cornea to slightly bend. This abnormal stress distribution greatly distorts the corneal optics and, more importantly, could be the cause of clinical problems such as corneal extrusion. Not only that, but our model also supports that rings are acting as restraint elements which relax the stresses of the corneal stroma in the cone of the disease. However, depending on the exact spatial location of the keratoconus, the insertion of rings could promote its evolution instead of preventing it. ICRS inserted deeper will prevent keratoconus in the posterior stroma from growing (relaxation of posterior surface), but will promote its growing if they are located in the anterior surface (increment of stress). In conclusion, the methodology proposed is suitable for simulating long-term mechanical and optical effects of ICRS insertion.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Consistent data-driven computational mechanics

  • González, D.
  • Chinesta, F.
  • Cueto, E.
We present a novel method, within the realm of data-driven computational mechanics, to obtain reliable and thermodynamically sound simulation from experimental data. We thus avoid the need to fit any phenomenological model in the construction of the simulation model. This kind of techniques opens unprecedented possibilities in the framework of data-driven application systems and, particularly, in the paradigm of industry 4.0.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

An Update on Corneal Biomechanics and Architecture in Diabetes

  • del Buey, María A.
  • Casas, Paula
  • Caramello, Constanza
  • López, Nuria
  • de la Rica, Marisa
  • Subirón, Ana B.
  • Lanchares, Elena
  • Huerva, Valentín
  • Grzybowski, Andrzej
  • Ascaso, Francisco J.
In the last decade, we have witnessed substantial progress in our understanding of corneal biomechanics and architecture. It is well known that diabetes is a systemic metabolic disease that causes chronic progressive damage in the main organs of the human body, including the eyeball. Although the main and most widely recognized ocular effect of diabetes is on the retina, the structure of the cornea (the outermost and transparent tissue of the eye) can also be affected by the poor glycemic control characterizing diabetes. e different corneal structures (epithelium, stroma, and endothelium) are affected by specific complications of diabetes. e development of new noninvasive diagnostic technologies has provided a better understanding of corneal tissue modifications. e objective of this review is to describe the advances in the knowledge of the corneal alterations that diabetes can induce
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Physically sound, self-learning digital twins for sloshing fluids

  • Moya, Beatriz
  • Alfaro, Iciar
  • Gonzalez, David
  • Chinesta, Francisco
  • Cueto, Elías
In this paper, a novel self-learning digital twin strategy is developed for fluid sloshing phenomena. This class of problems is of utmost importance for robotic manipulation of fluids, for instance, or, in general, in simulation-assisted decision making. The proposed method infers the (linear or non-linear) constitutive behavior of the fluid from video sequences of the sloshing phenomena. Real-time prediction of the fluid response is obtained from a reduced order model (ROM) constructed by means of thermodynamics-informed data-driven learning. From these data, we aim to predict the future response of a twin fluid reacting to the movement of the real container. The constructed system is able to perform accurate forecasts of its future reactions to the movements of the containers. The system is completed with augmented reality techniques, so as to enable comparisons among the predicted result with the actual response of the same liquid and to provide the user with insightful information about the physics taking place.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Incremental dynamic mode decomposition: A reduced-model learner operating at the low-data limit

  • Reille, A.
  • Hascoet, N.
  • Ghnatios, C.
  • Ammar, A.
  • Cueto, E.
  • Duval, J.L.
  • Chinesta, F.
  • Keunings, R.
The present work aims at proposing a new methodology for learning reduced models from a small amount of data. It is based on the fact that discrete models, or their transfer function counterparts, have a low rank and then they can be expressed very efficiently using few terms of a tensor decomposition. An efficient procedure is proposed as well as a way for extending it to nonlinear settings while keeping limited the impact of data noise. The proposed methodology is then validated by considering a nonlinear elastic problem and constructing the model relating tractions and displacements at the observation points.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Physics perception in sloshing scenes with guaranteed thermodynamic consistency

  • Moya, Beatriz
  • Badias, Alberto
  • Gonzalez, David
  • Chinesta, Francisco
  • Cueto, Elías
Physics perception very often faces the problem that only limited data or partial measurements on the scene are available. In this work, we propose a strategy to learn the full state of sloshing liquids from measurements of the free surface. Our approach is based on recurrent neural networks (RNN) that project the limited information available to a reduced-order manifold to not only reconstruct the unknown information but also be capable of performing fluid reasoning about future scenarios in real-time. To obtain physically consistent predictions, we train deep neural networks on the reduced-order manifold that, through the employ of inductive biases, ensure the fulfillment of the principles of thermodynamics. RNNs learn from history the required hidden information to correlate the limited information with the latent space where the simulation occurs. Finally, a decoder returns data to the high-dimensional manifold, to provide the user with insightful information in the form of augmented reality. This algorithm is connected to a computer vision system to test the performance of the proposed methodology with real information, resulting in a system capable of understanding and predicting future states of the observed fluid in real-time.