Publication Artículo científico (JournalArticle)

Green-tape ceramics. New technological approach for integrating electronics and fluidics in microsystems

  • Ibáñez García, Núria
  • Alonso, Julián
  • Martínez Cisneros, Cynthia Susana
  • Valdés, Francisco
The miniaturization of analytical systems for different applications is currently a very active field of research. The inherent advantages of micro total analysis systems (muTASs) are well known. Although the fluidic platforms and the development of suitable miniaturized detection systems have been studied extensively, the integration in a single substrate of the electronics that is needed to manage the whole system using a single technology is still a sizeable challenge. In this overview, we discuss the role of the low-temperature co-fired ceramics (LTCC) as a potential alternative for miniaturizing analytical systems, since a single technology can easily combine fluidics and electronics to produce a number of novel chemical microanalyzers., The authors would like to thank the Spanish MEC for its financial support through: Consolider-Ingenio 2010 (CSD2006-00012), TEC2006-13907-C04-04/MIC and CIT-310200-2007-29., Publicado
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publication Artículo científico (JournalArticle)

A monolithic continuous-flow microanalyzer with amperometric detection based on the green tape technology

  • Martínez Cisneros, Cynthia Susana
  • Da Rocha, Zaira
  • Ferreira, Marcos
  • Valdés, Francisco
  • Seabra, Antonio
  • Góngora Rubio, Mario
  • Alonso Chamarro, Julián
The development of micro total analysis systems (muTAS) has become a growing research field. Devices that include not only the fluidics and the detection system but also the associated electronics are reported scarcely in the literature because of the complexity and the cost involved for their monolithic integration. Frequently, dedicated devices aimed at solving specific analytical problems are needed. In these cases, low-volume production processes are a better alternative to mass production technologies such as silicon and glass. In this work, the design, fabrication, and evaluation of a continuous-flow amperometric microanalyzer based on the green tape technology is presented. The device includes the microfluidics, a complete amperometric detection system, and the associated electronics. The operational lifetime of the working electrode constitutes a major weak point in electrochemical detection systems, especially when it is integrated in monolithic analytical devices. To increase the overall system reliability and its versatility, it was integrated following an exchangeable configuration. Using this approach, working electrodes can be readily exchanged, according to the analyte to be determined or when their surfaces become passivated or poisoned. Furthermore, the electronics of the system allow applying different voltamperometric techniques and provide four operational working ranges (125, 12.5, 1.25, and 0.375 muA) to do precise determinations at different levels of current intensity., The authors would like to thank the Spanish MEC for its financial support through: Consolider-Ingenio 2010 (CSD2006-00012), TEC2006-13907-C04-04/MIC and CIT- 310200-2007-29.
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publication Artículo científico (JournalArticle)

Miniaturized total analysis systems: integration of electronics and fluidics using low-temperature co-fired ceramics

  • Martínez Cisneros, Cynthia Susana
  • Ibáñez García, Núria
  • Valdés, Francisco
  • Alonso, Julián
The advantages of microanalyzers, usually fabricated in silicon, glass, or polymers, are well-known. The design and construction of fluidic platforms are well-developed areas due to the perfectly established microfabrication technologies used. However, there is still the need to achieve devices that include not only the fluid management system but also the measurement electronics, so that real portable miniaturized analyzers can be obtained. Low-temperature co-fired ceramics technology permits the incorporation of actuators, such as micropumps and microvalves, controlled either magnetically, piezoelectrically, or thermally. Furthermore, electronic circuits can be also easily built exploiting the properties of these ceramics and the fact that they can be fabricated using a multilayer approach. In this work, taking advantage of the possibility of combining fluidics and electronics in a single substrate and using the same fabrication methodology, a chemical microanalyzer that integrates microfluidics, the detection system, and also the data acquisition and digital signal processing electronics is presented. To demonstrate the versatility of the technology, two alternative setups have been developed. In the first one, a modular configuration is proposed. In this case, the same electronic module can be used to determine different chemical parameters by simply exchanging the chemical module. In the second one, the monolithic integration of all the elements was accomplished, allowing the construction of compact and dedicated devices. Chloride ion microanalyzers have been constructed to demonstrate the operability of both device configurations. In all cases, the results obtained showed adequate analytical features., The authors thank the Spanish MEC for its financial support through: Consolider-Ingenio 2010 (CSD2006-00012), TEC2006-13907-C04-04/MIC, and CIT-310200-2007-29. C.S.M.-C. is also thankful to the Alban Program (High-level grants from the Eurepean Union to Latin America for its financial support: Grant E05D053315MX) and Conacyt, Mexico for further financial assistance., Publicado
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publication Artículo científico (JournalArticle)

LTCC microflow analyzers with monolithic integration of thersmal control

  • Martínez Cisneros, Cynthia Susana
  • Ibáñez García, Núria
  • Valdés, Francisco
  • Alonso Chamarro, Julián
Recently, the low temperature co-fired ceramics technology has shown to be an excellent alternative to silicon-based microfabrication techniques for the production of three-dimensional structures using a multi-layer approach. This enables the integration of several unitary operations of a classical analytical process and also the integration of sensors, actuators and electronics in the same substrate. In this work, we show the integration of the actuators and the sensors needed for the control of temperature inside a miniaturized fluidic device. The proposed device presents enough thermal accuracy to be used in chemical systems where temperature control is a crucial factor, such as enzyme reactions or polymerase chain reaction systems., The authors would like to thank the Spanish MEC for its financial support through: Consolider-Ingenio 2010 (CSD2006-00012), TEC2006-13907-C04-04/MIC and CIT-310200-2007-29. CSM is also thankful to the Alban Program (High-level grants from the European Union to Latin America for its financial support (Grant number: E05D053315MX).