Skip to main content

INTERPRETACION Y CARACTERIZACION DE METODOS DE ANALISIS DE COMPLEJIDAD EN EL CONTEXTO DEL PROCESADO BIOMEDICO DE LA SEÑAL

TEC2009-14222

•
Funding agency name Ministerio de Ciencia e Innovación
Funding agency acronym MICINN
Program Programa Nacional de Proyectos de Investigación Fundamental
Subprogram Subprograma de Proyectos de Investigación Fundamental no Orientada
Call Proyectos I+D
Call year 2009
State Plan 2008-2011 Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica
Management unit Subdirección General de Proyectos de Investigación
Beneficiary centre UNIVERSITAT POLITÈCNICA DE VALÈNCIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 6
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Comparative study of approximate entropy and sample entropy robustness to spikes

  • Molina Picó, Antonio|||0000-0003-2414-5864
  • Cuesta Frau, David|||0000-0002-0076-0515
  • Miró Martínez, Pau|||0000-0001-9573-9104
  • Oltra Crespo, Sandra|||0000-0003-1995-2557
  • Riobo Aboy, Pedro Mateo
  • Crespo Sánchez, María Cristina
Objective: There is an ongoing research effort devoted to characterize the signal regularity metrics approximate entropy (ApEn) and sample entropy (SampEn) in order to better interpret their results in the context of biomedical signal analysis. Along with this line, this paper addresses the influence of abnormal spikes (impulses) on ApEn and SampEn measurements. Methods: A set of test signals consisting of generic synthetic signals, simulated biomedical signals, and real RR records was created. These test signals were corrupted by randomly generated spikes. ApEn and SampEn were computed for all the signals under different spike probabilities and for 100 realizations. Results: The effect of the presence of spikes on ApEn and SampEn is different for test signals with narrowband line spectra and test signals that are better modeled as broadband random processes. In the first case, the presence of extrinsic spikes in the signal results in an ApEn and SampEn increase. In the second case, it results in an entropy decrease. For real RR records, the presence of spikes, often due to QRS detection errors, also results in an entropy decrease. Conclusions: Our findings demonstrate that both ApEn and SampEn are very sensitive to the presence of spikes. Abnormal spikes should be removed, if possible, from signals before computing ApEn or SampEn. Otherwise, the results can lead to misunderstandings or misclassification of the signal regularity. © 2011 Elsevier B.V., This work has been supported by the Spanish Ministry of Science and Innovation, research projects TEC2008-05871 and TEC2009-14222.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Characterization of complex fractionated atrial electrograms by Sample Entropy: An international multi-center study

  • Cirugeda Roldán, Eva María
  • Novak, Daniel
  • Kremen, Vaclav
  • Keller, Matthias
  • Luik, Armin
  • Srutova, Martina
  • Cuesta Frau, David|||0000-0002-0076-0515
Atrial fibrillation (AF) is the most commonly clinically-encountered arrhythmia. Catheter ablation of AF is mainly based on trigger elimination and modification of the AF substrate. Substrate mapping ablation of complex fractionated atrial electrograms (CFAEs) has emerged to be a promising technique. To improve substrate mapping based on CFAE analysis, automatic detection algorithms need to be developed in order to simplify and accelerate the ablation procedures. According to the latest studies, the level of fractionation has been shown to be promisingly well estimated from CFAE measured during radio frequency (RF) ablation of AF. The nature of CFAE is generally nonlinear and nonstationary, so the use of complexity measures is considered to be the appropriate technique for the analysis of AF records. This work proposes the use of sample entropy (SampEn), not only as a way to discern between non-fractionated and fractionated atrial electrograms (A-EGM), but also as a tool for characterizing the degree of A-EGM regularity, which is linked to changes in the AF substrate and to heart tissue damage. The use of SampEn combined with a blind parameter estimation optimization process enables the classification between CFAE and non-CFAE with statistical significance (p < 0:001), 0.89 area under the ROC, 86% specificity and 77% sensitivity over a mixed database of A-EGM combined from two independent CFAE signal databases, recorded during RF ablation of AF in two EU countries (542 signals in total). On the basis of the results obtained in this study, it can be suggested that the use of SampEn is suitable for real-time support during navigation of RF ablation of AF, as only 1.5 seconds of signal segments need to be analyzed., This work has been supported by the Spanish Ministry of Science and Innovation, Research Project TEC 2009-14222, by the Ministry of Education Youth and Sports of the Czech Republic, the Grant Agency of the Czech Technical University in Prague No. SGS13/203/OHK3/3T/13 and by the Czech Science 300 Foundation post-doctoral GACR research project GACR #P103/11/P106.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Comparative study of entropy sensitivity to missing biosignal data

  • Cirugeda Roldán, Eva María
  • Cuesta Frau, David|||0000-0002-0076-0515
  • Miró Martínez, Pau|||0000-0001-9573-9104
  • Oltra Crespo, Sandra|||0000-0003-1995-2557
Entropy estimation metrics have become a widely used method to identify subtle changes or hidden features in biomedical records. These methods have been more effective than conventional linear techniques in a number of signal classification applications, specially the healthy pathological segmentation dichotomy. Nevertheless, a thorough characterization of these measures, namely, how to match metric and signal features, is still lacking. This paper studies a specific characterization problem: the influence of missing samples in biomedical records. The assessment is conducted using four of the most popular entropy metrics: Approximate Entropy, Sample Entropy, Fuzzy Entropy, and Detrended Fluctuation Analysis. The rationale of this study is that missing samples are a signal disturbance that can arise in many cases: signal compression, non-uniform sampling, or data transmission stages. It is of great interest to determine if these real situations can impair the capability of segmenting signal classes using such metrics. The experiments employed several biosignals: electroencephalograms, gait records, and RR time series. Samples of these signals were systematically removed, and the entropy computed for each case. The results showed that these metrics are robust against missing samples: With a data loss percentage of 50% or even higher, the methods were still able to distinguish among signal classes., This work has been supported by the Spanish Ministry of Science and Innovation, research project TEC2009-14222.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Influence of QRS complex detection errors on entropy algorithms. Application to heart rate variability discrimination

  • Molina Picó, Antonio|||0000-0003-2414-5864
  • Cuesta Frau, David|||0000-0002-0076-0515
  • Miró Martínez, Pau|||0000-0001-9573-9104
  • Oltra Crespo, Sandra|||0000-0003-1995-2557
  • Riobo Aboy, Pedro Mateo
Signal entropy measures such as Approximate Entropy (ApEn) and Sample Entropy (SampEn) are widely used in Heart Rate Variability (HRV) analysis and biomedical research. In this article, we analyze the influence of QRS detection errors on HRV results based on signal entropy measures. Specifically, we study the influence that QRS detection errors have on the discrimination power of ApEn and SampEn using the Cardiac Arrhythmia Suppression Trial (CAST) database. The experiments assessed the discrimination capability of ApEn and SampEn under different levels of QRS detection errors. The results demonstrate that these measures are sensitive to the presence of ectopic peaks: from a successful classification rate of 100%, down to a 75% when spikes are present. The discriminating capability of the metrics degraded as the number of misdetections increased. For an error rate of 2% the segmentation failed in a 12.5% of the experiments, whereas for a 5% rate, it failed in a 25%. (C) 2012 Elsevier Ireland Ltd. All rights reserved., This work has been supported by the Spanish Ministry of Science and Innovation, research project TEC2009-14222.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

A new algorithm for quadratic sample entropy optimization for very short biomedical signals: Application to blood pressure records

  • Cirugeda Roldán, Eva María
  • Vigil-Medina, L.
  • Varela-Entrecanales, M.
  • Cuesta Frau, David|||0000-0002-0076-0515
  • Miró Martínez, Pau|||0000-0001-9573-9104
  • Oltra Crespo, Sandra|||0000-0003-1995-2557
[EN] This paper describes a new method to optimize the computation of the quadratic sample entropy (QSE) metric. The objective is to enhance its segmentation capability between pathological and healthy subjects for short and unevenly sampled biomedical records, like those obtained using ambulatory blood pressure monitoring (ABPM). In ABPM, blood pressure is measured every 20-30 min during 24h while patients undergo normal daily activities. ABPM is indicated for a number of applications such as white-coat, suspected, borderline, or masked hypertension. Hypertension is a very important clinical issue that can lead to serious health implications, and therefore its identification and characterization is of paramount importance. Nonlinear processing of signals by means of entropy calculation algorithms has been used in many medical applications to distinguish among signal classes. However, most of these methods do not perform well if the records are not long enough and/or not uniformly sampled. That is the case for ABPM records. These signals are extremely short and scattered with outliers or missing/resampled data. This is why ABPM Blood pressure signal screening using nonlinear methods is a quite unexplored field. We propose an additional stage for the computation of QSE independently of its parameter r and the input signal length. This enabled us to apply a segmentation process to ABPM records successfully. The experimental dataset consisted of 61 blood pressure data records of control and pathological subjects with only 52 samples per time series. The entropy estimation values obtained led to the segmentation of the two groups, while other standard nonlinear methods failed. (C) 2014 Elsevier Ireland Ltd. All rights reserved., This work has been supported by the Spanish Ministry of Science and Innovation, research project TEC2009-14222.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Automatic sleep stages classification using EEG entropy features and unsupervised pattern analysis techniques

  • Rodríguez-Sotelo, Jose Luis
  • Osorio-Forero, Alejandro
  • Jiménez-Rodríguez, Alejandro
  • Cirugeda Roldán, Eva María
  • Peluffo, Diego
  • Cuesta Frau, David|||0000-0002-0076-0515
Sleep is a growing area of research interest in medicine and neuroscience. Actually, one major concern is to find a correlation between several physiologic variables and sleep stages. There is a scientific agreement on the characteristics of the five stages of human sleep, based on EEG analysis. Nevertheless, manual stage classification is still the most widely used approach. This work proposes a new automatic sleep classification method based on unsupervised feature classification algorithms recently developed, and on EEG entropy measures. This scheme extracts entropy metrics from EEG records to obtain a feature vector. Then, these features are optimized in terms of relevance using the Q-&#945; algorithm. Finally, the resulting set of features is entered into a clustering procedure to obtain a final segmentation of the sleep stages. The proposed method reached up to an average of 80% correctly classified stages for each patient separately while keeping the computational cost low., The authors would like to thank Universidad Autonoma de Manizales for financial support in the present work (Research project 328-038). This work has also been supported by the Spanish Ministry of Science and Innovation, research project TEC2009-14222.