Skip to main content

APLICACION DE TECNICAS LAPLACIANAS PARA LA MONITORIZACION DE LA ACTIVIDAD ELECTRICA DEL MUSCULO LISO HUMANO: ENFASIS EN ELECTROHISTEROGRAMA

TEC2010-16945

•
Funding agency name Ministerio de Ciencia e Innovación
Funding agency acronym MICINN
Program Programa Nacional de Proyectos de Investigación Fundamental
Subprogram Subprograma de Proyectos de Investigación Fundamental no Orientada
Call Proyectos I+D
Call year 2010
State Plan 2008-2011 Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica
Management unit Subdirección General de Proyectos de Investigación
Beneficiary centre UNIVERSITAT POLITÈCNICA DE VALÈNCIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 6
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Feasibility and analysis of bipolar concentric recording of Electrohysterogram with flexible active electrode

  • Ye Lin, Yiyao
  • Alberola Rubio, José
  • Perales Marin, Alfredo Jose
  • Desantes, D.
  • Prats-Boluda, Gema|||0000-0002-9362-5055
  • Garcia-Casado, Javier|||0000-0003-1410-2721
The conduction velocity and propagation patterns of Electrohysterogram (EHG) provide fundamental information about uterine electrophysiological condition. The accuracy of these measurements can be impaired by both the poor spatial selectivity and sensitivity to the relative direction of the contraction propagation associated with conventional disc electrodes. Concentric ring electrodes could overcome these limitations the aim of this study was to examine the feasibility of picking up surface EHG signals using a new flexible tripolar concentric ring electrode (TCRE), and to compare it with conventional bipolar recordings. Simultaneous recording of conventional bipolar signals and bipolar concentric EHG (BC-EHG) were carried out on 22 pregnant women. Signal bursts were characterized and compared. No significant differences among channels in either duration or dominant frequency in the Fast Wave High frequency range were found. Nonetheless, the high pass filtering effect of the BC-EHG records resulted in lower frequency content within the range 0.1 to 0.2 Hz than the bipolar ones. Although the BC-EHG signal amplitude was about 5-7 times smaller than that of bipolar recordings, similar signal-to-noise ratio was obtained. These results suggest that the flexible TCRE is able to pick up uterine electrical activity and could provide additional information for deducing uterine electrophysiological condition., The authors are grateful to the Obstetrics Unit of the Hospital Universitario La Fe de Valencia (Valencia, Spain), where the recording sessions were carried out. The work was supported in part by the Ministerio de Ciencia y Tecnologia de Espana (TEC2010-16945), by the Universitat Politecnica de Valencia (PAID SP20120490) and Generalitat Valenciana (GV/2014/029) and by General Electric Healthcare.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Comparison of non-invasive electrohysterographic recording techniques for monitoring uterine dynamics

  • Alberola Rubio, José
  • Valero, J.
  • Perales Marin, Alfredo Jose
  • Prats-Boluda, Gema|||0000-0002-9362-5055
  • Ye Lin, Yiyao|||0000-0003-2929-181X
  • Garcia-Casado, Javier|||0000-0003-1410-2721
Non-invasive recording of uterine myoelectric activity (electrohysterogram, EHG) could provide an alternative to monitoring uterine dynamics by systems based on tocodynamometer (TOCO). Laplacian recording of bioelectric signals has been shown to give better spatial resolution and less interference than mono and bipolar surface recordings. The aim of this work was to study the signal quality obtaines from monopolar, bipolar and Laplacian techniques in EHG recordings, as well as to assess their ability to detect uterine contractions. Twenty-two recording sessions were carried out on singleton pregnant women during the active phase of labour. In each session the following simultaneous recordings were obtained: internal uterine pressure (IUP), external tension of abdominal wall (TOCO) and EHG signals (5 monopolar and 4 bipolar recordings, 1 discrete aproximation to the Laplacian of the potential and 2 estimates of the Laplacian from two active annular electrodes). The results obtained show that EHG is able to detect a higher number of uterine contractions than TOCO. Laplacian recordings give improved signal quality over monopolar and bipolar techniques, reduce maternal cardiac interference and improve the signal-to-noise ratio. The optimal position for recording EHG was found to be the uterine median axis and the lower centre-right umbilical zone., Research partly supported by the Spanish Ministerio de Ciencia y Tecnologia (TEC2010-16945) and the Universitat Politecnica de Valencia (PAID 2009/10-2298). The translation of this paper was funded by the Universitat Politecnica de Valencia, Spain.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Active flexible concentric ring electrode for non-invasive surface bioelectrical recordings

  • Prats-Boluda, Gema|||0000-0002-9362-5055
  • Ye Lin, Yiyao|||0000-0003-2929-181X
  • Garcia-Breijo, Eduardo|||0000-0002-9745-8485
  • Ibáñez Civera, Francisco Javier|||0000-0002-1035-2662
  • Garcia-Casado, Javier|||0000-0003-1410-2721
Bioelectrical surface recordings are usually performed by unipolar or bipolar disc electrodes even though they entail the serious disadvantage of having poor spatial resolution. Concentric ring electrodes give improved spatial resolution, although this type of electrode has so far only been implemented in rigid substrates and as they are not adapted to the curvature of the recording surface may provide discomfort to the patient. Moreover, the signals recorded by these electrodes are usually lower in amplitude than conventional disc electrodes. The aim of this work was thus to develop and test a new modular active sensor made up of concentric ring electrodes printed on a flexible substrate by thick-film technology together with a reusable battery-powered signal-conditioning circuit. Simultaneous ECG recording with both flexible and rigid concentric ring electrodes was carried out on ten healthy volunteers at rest and in motion. The results show that flexible concentric ring electrodes not only present lower skin electrode contact impedance and lower baseline wander than rigid electrodes but are also less sensitive to interference and motion artefacts. We believe these electrodes, which allow bioelectric signals to be acquired non-invasively with better spatial resolution than conventional disc electrodes, to be a step forward in the development of new monitoring systems based on Laplacian potential recordings., This research was supported in part by the Ministerio de Ciencia y Tecnologia de Espana (TEC2010-16945) and by the Universitat Politecnica de Valencia (PAID 2009/10-2298). The proof-reading of this paper was funded by the Universitat Politecnica de Valencia, Spain.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Automatic identification of motion artifacts in EHG recording for robust analysis of uterine contractions

  • Ye-Lin, Yiyao
  • Alberola Rubio, José
  • Perales Marin, Alfredo Jose
  • Garcia-Casado, Javier|||0000-0003-1410-2721
  • Prats-Boluda, Gema|||0000-0002-9362-5055
Electrohysterography (EHG) is a non-invasive technique for monitoring uterine electrical activity. However, the presence of artifacts in the EHG signal may give rise to erroneous interpretations and make it difficult to extract useful information from these recordings. The aim of this work was to develop an automatic system of segmenting EHG recordings that distinguishes between uterine contractions and artifacts. Firstly, the segmentation is performed using an algorithm that generates the toco-like signal derived from the EHG and detects windows with significant changes in amplitude. After that, these segments are classified in two groups: artifacted and non-artifacted signals. To develop a classifier, a total of eleven spectral, temporal and non-linear features were calculated from EHG signal windows from 12 women in the first stage of labor that had previously been classified by experts. The combination of characteristics that led to the highest degree of accuracy in detecting artifacts was then determined. The results showed that it is possible to obtain automatic detection of motion artifacts in segmented EHG recordings with a precision of 92.2% using only seven features. The proposed algorithm and classifier together compose a useful tool for analyzing EHG signals and would help to promote clinical applications of this technique., The authors are grateful to the R + D + I Linguistic Assistance Office at the UPV for their help in proofreading this paper. The work was supported by the Ministerio de Ciencia e Innovacion de Espana (TEC2010-16945).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Enhancement of Non-Invasive Recording of Electroenterogram by Means of a Flexible Array of Concentric Ring Electrodes

  • Garcia-Casado, Javier|||0000-0003-1410-2721
  • Prats-Boluda, Gema|||0000-0002-9362-5055
  • Ye Lin, Yiyao|||0000-0003-2929-181X
  • Zena Giménez, Víctor Fabián
Monitoring intestinal myoelectrical activity by electroenterogram (EEnG) would be of great clinical interest for diagnosing gastrointestinal pathologies and disorders. However, surface EEnG recordings are of very low amplitude and can be severely affected by baseline drifts and respiratory and electrocardiographic (ECG) interference. In this work, a flexible array of concentric ring electrodes was developed and tested to determine whether it can provide surface EEnG signals of better quality than bipolar recordings from conventional disc electrodes. With this aime, sixteen healthy subjects in a fasting state (>8h) underwent recording. The capabiltiy of detecting intestinal pacemaker activity (slow wave) and the influence of physiological interferences were studied. The signals obtained from the concentric ring electrodes proved to be more robust to ECG and respiratory interference than those from conventional disc electrodes. The results also show that intestinal EEnG components such as the slow wave can be more easily identified by the proposed system based on a flexible array of concentric ring electrodes. The developed active electrode array could be a very valuable tool for non-invasive diagnosis of disease states such as ischemia and motility disorders of the small bowel which are known to alter the normal enteric slow wave activity., Research supported in part by the Ministerio de Ciencia y Tecnologia de Espana (TEC 2010-16945). The proof-reading of this paper was funded by the Universitat Politecnica de Valencia, Spain.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Flexible Concentric Ring Electrode for Non Invasive Bioelectrical Surface Recordings

  • Prats-Boluda, Gema|||0000-0002-9362-5055
  • Gil Sánchez, Luís|||0000-0003-3453-5559
  • Ye Lin, Yiyao|||0000-0003-2929-181X
  • Ibáñez Civera, Francisco Javier|||0000-0002-1035-2662
  • Garcia-Casado, Javier|||0000-0003-1410-2721
  • Garcia-Breijo, Eduardo|||0000-0002-9745-8485
[EN] Non-invasive bioelectrical recordings are usually carried out by using monopolar or bipolar disc electrodes. The poor spatial resolution is one important disadvantage of this kind of electrodes tending to pick up physiological interferences. Concentric ring electrodes have already been implemented in rigid substrates to increase the spatial resolution in the recording of bioelectrical signals such as the electrocardiography (ECG) or the electroencephalography (EEG). Our goal was to develop and test a new modular active sensor made up of a disposable sensing part with concentric ring electrodes printed on a flexible substrate by thick-film technology connected to a battery powered signal conditioning circuit, and to compare it to rigid conventional concentric ring electrodes implemented on printed circuit board. Simultaneous ECG recordings were carried out using both flexible and rigid electrodes. Results show that flexible concentric ring electrodes present lower skin-electrode contact impedance, higher amplitude and lower baseline wander than the rigid ones., Authors ackowledge financial support from the Spanish Government and its MICINN (MAT2009-14564-C04-02), MICINN (TEC2010-16945), the Universitat Politècnia de Valencia trough Nuevas Líneas de Investigación Multidisciplinares (PAID-05-11) for their respective research fellowship