Skip to main content

MODULO DETECTOR DE RAYOS GAMMA PARA SISTEMA DE NAVEGACION INTRAOPERATORIA GUIADA MEDIANTE IM/RM

TEC2013-48036-C3-1-R

•
Funding agency name Ministerio de Economía y Competitividad
Funding agency acronym MINECO
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos I+D+i Retos de Investigación
Call year 2013
State Plan 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Management unit Secretaría de Estado de Educación, Formación Profesional y Universidades
Beneficiary centre AGENCIA ESTATAL CONSEJO SUPERIOR DE INVESTIGACIONES CIENTIFICAS (CSIC)

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Calibration and Performance Tests of Detectors for Laser-Accelerated Protons

  • Seimetz, Michael
  • González Martínez, Antonio Javier
  • Moliner Martínez, Laura
  • Rodríguez-Álvarez, M.J.|||0000-0001-8333-8792
  • Sanchez, S.
  • Vidal San Sebastian, Luis Fernando|||0000-0001-8852-8560
  • Benlloch Baviera, Jose María|||0000-0001-6073-1436
  • Bellido, P.
  • Soriano Asensi, Antonio
  • García López, J.
  • Jiménez-Ramos, M.C.
  • Fernández, B.
  • Conde Castellanos, Pablo Eloy
  • Crespo Navarro, Efren
  • Hernández Hernández, Liczandro
  • Iborra Carreres, Amadeo
  • Rigla Pérez, Juan Pablo
  • Sanchez, F.
We present the calibration and performance tests carried out with two detectors for intense proton pulses accelerated by lasers. Most of the procedures were realized with proton beams of 0.46-5.60 MeV from a tandem accelerator. One approach made use of radiochromic films, for which we calibrated the relation between optical density and energy deposition over more than three orders of magnitude. The validity of these results and of our analysis algorithms has been confirmed by controlled irradiation of film stacks and reconstruction of the total beam charge for strongly non-uniform beam profiles. For the spectral analysis of protons from repeated laser shots, we have designed an online monitor based on a plastic scintillator. The resulting signal from a photomultiplier directly measured on a fast oscilloscope is especially useful for time-of-flight applications. Variable optical filters allow for suppression of saturation and an extension of the dynamic range. With pulsed proton beams we have tested the detector response to a wide range of beam intensities from single particles 3 x 10(5) to protons per 100 ns time interval., Project funded by the Spanish Ministry of Economy and Competitiveness and co-funded with FEDER's funds within the INNPACTO 2011 program under Grant No. IPT-2011-0862-900000. This work was supported by the Spanish Plan Nacional de Investigacion Cientifica, Desarrollo e Innovacion Tecnologica (I+D+i) under Grant No. TEC 2013-48036-C3-1-R and the Valencian Local Government under Grants PROMETEOII/2013/010 and ISIC 2011/013. The work of A. J. Gonzalez is financed by CSIC with a JAE-Doc contract under Junta de Ampliacion de Estudios program, cofinanced by the European Social Fund.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Performance Study of a Large Monolithic LYSO PET Detector With Accurate Photon DOI Using Retroreflector Layers

  • Gonzalez-Montoro, Andrea
  • Aguilar, Albert
  • Cañizares, Gabriel
  • Conde, Pablo
  • Hernández, Liczandro
  • Galasso, Matteo
  • Fabbri, Andrea
  • Vidal San Sebastian, Luis Fernando|||0000-0001-8852-8560
  • F Sánchez
  • Benlloch Baviera, Jose María|||0000-0001-6073-1436
  • González Martínez, Antonio Javier
[EN] Clinical and organ-dedicated PET systems typically require a high efficiency imposing the use of thick scintillators, normally through crystal arrays. To provide depth of interaction (DOI) information, two or more layers are sometimes mounted in the staggered or phoswich approach. In this paper, we are proposing an alternative using thick and large monolithic crystals. We have tested two surface treatments for a 50 mm x 50 mm x 20 mm LYSO block. We provide data in this paper as close as 5 mm to the lateral walls. We left those walls black painted and the exit face coupled to the photosensor (12 x 12 SiPM array) polished. The entrance face was: 1) black painted or 2) coupled to a retroreflector (RR) layer. These configurations keep a good DOI linearity and, on average, reached 4 mm DOI resolution, measured as the full width at half of the maximum. Approaches using RR layers return constant and good energy resolutions nearing 12%, compared to a range of 15%-16% in the case of totally black painted blocks. The best result concerning the detector spatial resolution was obtained when one of the smallest RR was used (120 um corner cube size), being 1.7 mm at the entrance crystal layer and 0.7 mm in the layer closest to the photosensor. These values worsen at least 30% for the black treatment case., This work was supported in part by the EU FP7 program under Grant 603002, in part by the Spanish Plan Nacional de Investigacion Cientifica, Desarrollo e Innovacion Tecnologica under Grant TEC 2013-48036-C3-1-R, and in part by the Valencian Local Government under Grant PROMETEOII/2013/010 and Grant ISIC 2011/013. The work of A. J. Gonzalez was supported by the CSIC through the Ramon y Cajal modality.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Calibration and performance tests of detectors for laser-accelerated protons

  • Seimetz, Michael
  • Bellido Millán, Pablo Jesús
  • Soriano, A.
  • García López, J.
  • Jiménez-Ramos, M. C.
  • Fernández-Martínez, Begoña
  • Conde, P.
  • Crespo, Efrén
  • González Martínez, Antonio Javier
  • Hernández Hernández, Liczandro
  • Iborra, A.
  • Moliner, L.
  • Rigla, J. P.
  • Rodríguez-Álvarez, María José
  • Sánchez, S.
  • Vidal, L. F.
  • Benlloch Baviera, José María
We present the calibration and performance tests carried out with two detectors for intense proton pulses accelerated by lasers. Most of the procedures were realized with proton beams of 0.46-5.60 MeV from a tandem accelerator. One approach made use of radiochromic films, for which we calibrated the relation between optical density and energy deposition over more than three orders of magnitude. The validity of these results and of our analysis algorithms has been confirmed by controlled irradiation of film stacks and reconstruction of the total beam charge for strongly non-uniform beam profiles. For the spectral analysis of protons from repeated laser shots, we have designed an online monitor based on a plastic scintillator. The resulting signal from a photomultiplier directly measured on a fast oscilloscope is especially useful for time-of-flight applications. Variable optical filters allow for suppression of saturation and an extension of the dynamic range. With pulsed proton beams we have tested the detector response to a wide range of beam intensities from single particles to 3 ×105 protons per 100 ns time interval., Project funded by the Spanish Ministry of Economy and Competitiveness and co-funded with FEDER's funds within the INNPACTO 2011 program under Grant No. IPT-2011-0862-900000. This work was supported by the Spanish Plan Nacional de Investigacion Cientifica, Desarrollo e Innovacion Tecnologica (I+D+i) under Grant No. TEC 2013-48036-C3-1-R and the Valencian Local Government under Grants PROMETEOII/2013/010 and ISIC 2011/013. The work of A. J. Gonzalez is financed by CSIC with a JAE-Doc contract under Junta de Ampliacion de Estudios program, cofinanced by the European Social Fund., Peer Reviewed