Skip to main content

PROCESADO DIGITAL NO LINEAL Y APRENDIZAJE ESTADISTICO CON NUCLEOS AUTOCORRELACION PARA APLICACIONES EN SALUD

TEC2013-48439-C4-1-R

•
Funding agency name Ministerio de Economía y Competitividad
Funding agency acronym MINECO
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos I+D+i Retos de Investigación
Call year 2013
State Plan 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Management unit Secretaría de Estado de Educación, Formación Profesional y Universidades
Beneficiary centre UNIVERSIDAD REY JUAN CARLOS

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Arrhythmia Mechanism and Scaling Effect on the Spectral Properties of Electroanatomical Maps with Manifold Harmonics

  • Sanroman-Junquera, Margarita
  • Mora-Jimenez, Inmaculada
  • Garcia-Alberola, Arcadio
  • Caamano, Antonio J.
  • Rojo-Alvarez, Jose L.
  • Trenor Gomis, Beatriz Ana|||0000-0001-9166-6112
[EN] Introduction: Spatial and temporal processing of intracardiac electrograms provides relevant information to support the arrhythmia ablation during electrophysio-logical studies. Current cardiac navigation systems (CNS) and electrocardiographic imaging (ECGI) build detailed 3-D electroanatomical maps (EAM), which represent the spatial anatomical distribution of bioelectrical features, such as activation time or voltage. Objective: We present a principled methodology for spectral analysis of both EAM geometry and bioelectrical feature in CNS or ECGI, including their spectral representation, cutoff frequency, or spatial sampling rate (SSR). Methods: Existing manifold harmonic techniques for spectral mesh analysis are adapted to account for a fourth dimension, corresponding to the EAM bioelectrical feature. Appropriate scaling is required to address different magnitudes and units. Results: With our approach, simulated and real EAM showed strong SSR dependence on both the arrhythmia mechanism and the cardiac anatomical shape. For instance, high frequencies increased significantly the SSR because of the "early-meets-late" in flutter EAM, compared with the sinus rhythm. Besides, higher frequency components were obtained for the left atrium (more complex anatomy) than for the right atrium in sinus rhythm. Conclusion: The proposed manifold harmonics methodology opens the field toward new signal processing tools for principled EAM spatiofeature analysis in CNS and ECGI, and to an improved knowledge on arrhythmia mechanisms., This work was partly supported by Spanish Research Projects TEC2013-48439-C4-1-R, TEC2016-75361-R, and TEC2016-75161-C2-1-4.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Noise maps for quantitative and clinical severity towards long-term ECG monitoring

  • Everss-Villalba, Estrella
  • Melgarejo-Meseguer, Francisco Manuel
  • Blanco-Velasco, Manuel
  • Gimeno-Blanes, Francisco Javier
  • Sala, Salvador
  • Rojo-Álvarez, José Luis
  • García-Alberola, Arcadi
This article belongs to the Special Issue Sensors for Health Monitoring and Disease Diagnosis., Noise and artifacts are inherent contaminating components and are particularly present in Holter electrocardiogram (ECG) monitoring. The presence of noise is even more significant in long-term monitoring (LTM) recordings, as these are collected for several days in patients following their daily activities; hence, strong artifact components can temporarily impair the clinical measurements from the LTM recordings. Traditionally, the noise presence has been dealt with as a problem of non-desirable component removal by means of several quantitative signal metrics such as the signal-to-noise ratio (SNR), but current systems do not provide any information about the true impact of noise on the ECG clinical evaluation. As a first step towards an alternative to classical approaches, this work assesses the ECG quality under the assumption that an ECG has good quality when it is clinically interpretable. Therefore, our hypotheses are that it is possible (a) to create a clinical severity score for the effect of the noise on the ECG, (b) to characterize its consistency in terms of its temporal and statistical distribution, and (c) to use it for signal quality evaluation in LTM scenarios. For this purpose, a database of external event recorder (EER) signals is assembled and labeled from a clinical point of view for its use as the gold standard of noise severity categorization. These devices are assumed to capture those signal segments more prone to be corrupted with noise during long-term periods. Then, the ECG noise is characterized through the comparison of these clinical severity criteria with conventional quantitative metrics taken from traditional noise-removal approaches, and noise maps are proposed as a novel representation tool to achieve this comparison. Our results showed that neither of the benchmarked quantitative noise measurement criteria represent an accurate enough estimation of the clinical severity of the noise. A case study of long-term ECG is reported, showing the statistical and temporal correspondences and properties with respect to EER signals used to create the gold standard for clinical noise. The proposed noise maps, together with the statistical consistency of the characterization of the noise clinical severity, paves the way towards forthcoming systems providing us with noise maps of the noise clinical severity, allowing the user to process different ECG segments with different techniques and in terms of different measured clinical parameters., This work was supported by the PRINCIPIAS project (TEC2013-48439-C4-1-R and TEC2013-48439-C4-2-R), FINALE project (TEC2016-75161-C2-1-R and TEC2016-75161-C2-2-R), KERMES project (TEC2016-81900-REDT), and project TEC2015-64835-C3-1-R with FEDER fundings. These grants allow to cover open access costs for publication., Peer reviewed
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

On the Influence of Heart Rate and Coupling Interval Prematurity on Heart Rate Turbulence

  • Barquero-Pérez, Ó
  • Figuera, C.
  • Goya-Esteban, R.
  • Mora-Jiménez, I.
  • Gimeno-Blanes, F. J.
  • Laguna, P.
  • Martínez, J.P.
  • Gil, E.
  • Sörnmo, L.
  • García-Alberola, A.
  • Rojo-Álvarez J.L.
Objective: Heart rate turbulence (HRT) has been successfully explored for cardiac risk stratification. While HRT is known to be influenced by the heart rate (HR) and the coupling interval (CI), nonconcordant results have been reported on how the CI influences HRT. The purpose of this study is to investigate HRT changes in terms of CI and HR by means of an especially designed protocol. Methods: A dataset was acquired from 11 patients with structurally normal hearts for which CI was altered by different pacing trains and HR by isoproterenol during electrophysiological study (EPS). The protocol was designed so that, first, the effect of HR changes on HRT and, second, the combined effect of HR and CI could be explored. As a complement to the EPS dataset, a database of 24-h Holters from 61 acute myocardial infarction (AMI) patients was studied for the purpose of assessing risk. Data analysis was performed by using different nonlinear ridge regression models, and the relevance of model variables was assessed using resampling methods. The EPS subjects, with and without isoproterenol, were analyzed separately. Results: The proposed nonlinear regression models were found to account for the influence of HR and CI on HRT, both in patients undergoing EPS without isoproterenol and in low-risk AMI patients, whereas this influence was absent in high-risk AMI patients. Moreover, model coefficients related to CI were not statistically significant, p > 0.05, on EPS subjects with isoproterenol. Conclusion: The observed relationship between CI and HRT, being in agreement with the baroreflex hypothesis, was statistically significant (p < 0.05), when decoupling the effect of HR and normalizing the CI by the HR. Significance: The results of this study can help to provide new risk indicators that take into account physiological influence on HRT, as well as to model how this influence changes in different cardiac conditions.