Skip to main content

ESTUDIO DEL COMPORTAMIENTO DEL SISTEMA NERVIOSO AUTONOMO, Y HABILIDADES COGNITIVAS, EN ENTORNOS HIPERBARICOS

TEC2014-54143-P

•
Funding agency name Ministerio de Economía y Competitividad
Funding agency acronym MINECO
Program Programa Estatal de Fomento de la Investigación Científica y Técnica de Excelencia
Subprogram Subprograma Estatal de Generación de Conocimiento
Call Proyectos de I+D (Excelencia / Generación de Conocimiento)
Call year 2014
State Plan 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Management unit Secretaría de Estado de Educación, Formación Profesional y Universidades
Beneficiary centre CENTRO UNIVERSITARIO DE DEFENSA ACADEMIA GENERAL MILITAR

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Autonomic nervous system measurement in hyperbaric environments using ECG and PPG signals

  • Hernando, Alberto
  • Peláez-Coca, María Dolores
  • Lozano, María Teresa
  • Aiger, Monserrat
  • Izquierdo, David
  • Sánchez, Alberto
  • López-Jurado, María Isabel
  • Moura, Ignacio
  • Fidalgo, Joaquín
  • Lázaro, Jesús
  • Gil, Eduardo
The main aim of this work was to characterise the Autonomic Nervous System (ANS) response in hyper- baric environments using electrocardiogram (ECG) and pulse- photoplethysmogram (PPG) signals. To that end, 26 subjects were introduced into a hyperbaric chamber and five stages with different atmospheric pressures (1 atm; descent to 3 and 5 atm; ascent to 3 and 1 atm) were recorded. Respiratory information was extracted from the ECG and PPG signals and a combined respiratory rate was studied. This information was also used to analyse Heart Rate Variability (HRV) and Pulse Rate Variability (PRV). The database was cleaned by eliminating those cases where the respiratory rate dropped into the low frequency band (LF: 0.04-0.15 Hz) and those in which there was a discrepancy between the respiratory rates estimated using the ECG and PPG signals. Classical temporal and frequency indices were calculated in such cases. The ECG results showed a time-related depen- dency, with the heart rate and sympathetic markers (normalised power in LF and LF/HF ratio) decreasing as more time was spent inside the hyperbaric environment. A dependency between the atmospheric pressure and the parasympathetic response, as reflected in the high frequency band power (HF: 0.15-0.40 Hz), was also found, with power increasing with atmospheric pressure. The combined respiratory rate also reached a maximum in the deepest stage, thus highlighting a significant difference between this stage and the first one. The PPG data gave similar findings and also allowed the oxygen saturation to be computed, therefore we propose the use of this signal for future studies in hyperbaric environments.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Photoplethysmographic Waveform Versus Heart Rate Variability to Identify Low Stress States. Attention Test

  • Peláez Coca, María Dolores
  • Lozano Albalate, María Teresa
  • Hernando Sanz, Alberto
  • Aiger Vallés, Montserrat
  • Gil, Eduardo
Our long-term goal is the development of an automatic identifier of attentional states. In order to accomplish it, we should firstly be able to identify different states based on physiological signals. So, the first aim of this work is to identify the most appropriate features, to detect a subject high performance state. For that, a database of electrocardiographic (ECG) and photopletysmographic (PPG) signals is recorded in two unequivocally defined states (rest and attention task) from up to 50 subjects as a sample of the population. Time and frequency parameters of heart/pulse rate variability have been computed from the ECG/PPG signals respectively. Additionally, the respiratory rate has been estimated from both signals and also six morphological parameters from PPG. In total, twenty six features are obtained for each subject. They provide information about the autonomic nervous system and the physiological response of the subject to an attention demand task. Results show an increase of sympathetic activation when the subjects perform the attention test. The amplitude and width of the PPG pulse were more sensitive that the classical sympathetic markers (normalised power in LF and LF/HF ratio) for identifying this attentional state. State classification accuracy reaches a mean of 89 $\pm$ 2%, a maximum of 93% and a minimum of 85%, in the hundred classifications made by only selecting four parameters extracted from the PPG signal (pulse amplitude, pulse width, pulse downward slope and mean pulse rate). These results suggest that attentional states could be identified by PPG.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Significant Physiological Features to Identify High Performance States

  • Pelaez Coca, María Dolores
  • Lozano Albalate, María Teresa
  • Aiger, Montserrat
  • Hernando, Alberto
  • Gil, Eduardo
Our long-term goal is the development of an automaticidentifier of attentional states. In order to accomplish it, we should firstly be able to identify different states. So, the first aim of this work is to identify the most appropriate features, to detect a subject high performance state. For that, a database of electrocardiographic (ECG) signal of two unequivocally defined states (rest and attention task) is needed. To achieve this goal, ECG signal is recorded, in those cognitive states from up to 54 subjects as a sample of the population. Temporal and frequency parameters of heart rate variability have been computed from ECG signal. Additionally, the respiratory rate has been estimated from the same signal. In total, ten features are obtained for each subject. They provide information about the physiological response of the subject and about his autonomic nervous system. Results show that eight from these features present significant differences between subject’s baseline and subject’s attentional state; and selecting only four of them, state classification accuracy reaches a mean of 75.91%.