OPTIMIZACION DE LAS PRESTACIONES DE SMOS Y FUTURAS MISIONES

TEC2014-58582-R

•
Funding agency name Ministerio de Economía y Competitividad
Funding agency acronym MINECO
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos I+D+i Retos de Investigación
Call year 2014
State Plan 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Management unit Secretaría de Estado de Educación, Formación Profesional y Universidades
Beneficiary centre UNIVERSITAT POLITECNICA DE CATALUNYA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 10
Encontrada(s) 1 página(s)

Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Dielectric properties of colon polyps, cancer, and normal mucosa: Ex vivo measurements from 0.5 to 20 GHz

  • Guardiola, Marta
  • Buitrago, Santiago
  • Fernández-Esparrach, Gloria
  • O’Callaghan, Joan M.
  • Romeu, Jordi
  • Cuatrecasas, Miriam
  • Córdova, Henry
  • González Ballester, Miguel Ángel, 1973-
  • Camara, Oscar
Purpose: Colorectal cancer is highly preventable by detecting and removing polyps, which are the precursors. Currently, the most accurate test is colonoscopy, but still misses 22% of polyps due to visualization limitations. In this paper, we preliminary assess the potential of microwave imaging and dielectric properties (e.g., complex permittivity) as a complementary method for detecting polyps and cancer tissue in the colon. The dielectric properties of biological tissues have been used in a wide variety of applications, including safety assessment of wireless technologies and design of medical diagnostic or therapeutic techniques (microwave imaging, hyperthermia, and ablation). The main purpose of this work is to measure the complex permittivity of different types of colon polyps, cancer, and normal mucosa in ex vivo human samples to study if the dielectric properties are appropriate for classification purposes. Methods: The complex permittivity of freshly excised healthy colon tissue, cancer, and histological samples of different types of polyps from 23 patients was characterized using an open-ended coaxial probe between 0.5 and 20 GHz. The obtained measurements were classified into five tissue groups before applying a data reduction step with a frequency dispersive single-pole Debye model. The classification was finally compared with pathological analysis of tissue samples, which is the gold standard. Results: The complex permittivity progressively increases as the tissue degenerates from normal to cancer. When comparing to the gold-standard histological tissue analysis, the sensitivity and specificity of the proposed method is the following: 100% and 95% for cancer diagnosis; 91% and 62% for adenomas with high-grade dysplasia; 100% and 61% for adenomas with low-grade dysplasia; and 100% and 74% for hyperplastic polyps, respectively. In addition, complex permittivity measurements were independent of the lesion shape and size, which is also an interesting property comparing to current colonoscopy techniques. Conclusions: The contrast in complex permittivities between normal and abnormal colon tissues presented here for the first time demonstrate the potential of these measurements for tissue classification. It also opens the door to the development of a microwave endoscopic device to complement the outcomes of colonoscopy with functional tissue information., This work was supported by the Department of Universitats, Recerca i Societat de la Informacio of the Catalan Government through Llavor 2014LLAV00016 and producte 2016PROD00068 projects, La Caixa through Caixaimpulse program CI16-00058, the Spanish Comision Interministerial de Ciencia y Tecnologıa (CICYT) under projects TEC2016- 78028-C3-1-P, TEC2014-58582-R, the Spanish Agencia Estatal de Investigacion Unidad de Excelencia Maria de Maeztu (MDM-2016-0600), the Spanish Ministerio de Economıa, Industria y Competitividad, DTS17/00090 and CERCA Programme/Generalitat de Catalunya.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Otros (Other)

Direct faraday rotation angle retrieval in SMOS field of view

  • Rubino, Roselena
  • Torres, Francesc
  • Duffo, Nuria
  • González Gambau, Verónica
  • Corbella, Ignasi
  • Martín-Neira, Manuel
2017 IEEE International Geoscience and Remote Sensing Symposium (IGARSS), 23-28 July 2017, Fort Worth, TX, USA.-- 2 pages, 2 figures.-- © 2017 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works, It has recently been demonstrated that boresight averaged Faraday rotation angle (FRA) can be retrieved directly from SMOS full-pol radiometric data. However, in order to extend FRA retrievals to the full Alias-Free Field of View (AF-FoV), SMOS relatively poor pixel radiometric sensitivity and accuracy must be compensated by spatial and temporal averaging. This requires some kind of tradeoff to constrain systematic FRA estimation bias both within SMOS AF-FoV and along the orbit. This work presents the first results given by a SMOS end-to-end FRA simulator, currently under development, that is used to trim and assess the performance of several FRA retrieval approaches, This work has been supported by the European Space Agency and Deimos Engenharia (Portugal), SMOS P7 Subcontract DME CP12 no. 2015-005; ERDF (European Regional Development Fund) and by Spanish public funds, projects TEC2014-58582-R and ESP2015-67549-C3-1-R, Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Wide Field of View Microwave Interferometric Radiometer Imaging

  • Corbella, Ignasi
  • Torres, Francesc
  • Duffo, Nuria
  • Durán, Israel
  • González Gambau, Verónica
  • Martín-Neira, Manuel
Special Issue Ten Years of Remote Sensing at Barcelona Expert Center.-- 17 pages, 9 figures, In microwave interferometric radiometers with a large field of view, as for example the Microwave Imaging Radiometer with Aperture Synthesis (MIRAS) onboard the Soil Moisture and Ocean Salinity (SMOS) satellite, one of the major causes of reconstruction error is the contribution to the visibility of the brightness temperature outside the fundamental period, defined on the basis of reciprocal grids. A mitigation method consisting of estimating this contribution through the application of a brightness temperature model outside the fundamental period is proposed. The main advantage is that it does not require any a posteriori addition of artificial scenes to the reconstructed image. Additionally, a method to avoid the sophisticated matrix regularization and inversion techniques usually applied in microwave interferometry is presented. Image reconstruction algorithms are implemented on a minimum grid size in order to maximize their numerical efficiency. An improved method to apply an apodization window to the reconstructed image for reducing Gibbs oscillations is also proposed. All procedures are generally described considering the single polarization case and successively implemented applying the MIRAS layout in both its single polarization and full polarimetric modes. Results show similar performance of the proposed algorithm with respect to the nominal one applied by SMOS. All algorithms are implemented in the MIRAS Testing Software and have been successfully used for scientific studies by other teams, We acknowledge support by the CSIC Open Access Publication Initiative through its Unit of Information Resources for Research (URICI), This research was funded by the European Space Agency through SMOS P7 subcontract DME CP12 no. 2015-005 with Deimos Enginheria (Portugal) and by Ministerio de Economia, Industria y Competitividad, Gobierno de España, projects TEC2014-58582-R, TEC2017-88850-R and ESP2015-67549-C3-1-R, Peer reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Wide field of view microwave interferometric radiometer imaging

  • Corbella Sanahuja, Ignasi|||0000-0001-5598-7955
  • Torres Torres, Francisco|||0000-0003-1160-6350
  • Duffo Ubeda, Núria|||0000-0002-9398-3995
  • Durán Martínez, Israel
  • González Gambau, Verónica
  • Martín Neira, Manuel
In microwave interferometric radiometers with a large field of view, as for example the Microwave Imaging Radiometer with Aperture Synthesis (MIRAS) onboard the Soil Moisture and Ocean Salinity (SMOS) satellite, one of the major causes of reconstruction error is the contribution to the visibility of the brightness temperature outside the fundamental period, defined on the basis of reciprocal grids. A mitigation method consisting of estimating this contribution through the application of a brightness temperature model outside the fundamental period is proposed. The main advantage is that it does not require any a posteriori addition of artificial scenes to the reconstructed image. Additionally, a method to avoid the sophisticated matrix regularization and inversion techniques usually applied in microwave interferometry is presented. Image reconstruction algorithms are implemented on a minimum grid size in order to maximize their numerical efficiency. An improved method to apply an apodization window to the reconstructed image for reducing Gibbs oscillations is also proposed. All procedures are generally described considering the single polarization case and successively implemented applying the MIRAS layout in both its single polarization and full polarimetric modes. Results show similar performance of the proposed algorithm with respect to the nominal one applied by SMOS. All algorithms are implemented in the MIRAS Testing Software and have been successfully used for scientific studies by other teams., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

One-point microwave radiometer calibration

  • Corbella Sanahuja, Ignasi|||0000-0001-5598-7955
  • Torres Torres, Francisco|||0000-0003-1160-6350
  • Closa Soteras, Josep
  • Duffo Ubeda, Núria|||0000-0002-9398-3995
  • Durán Martínez, Israel
  • González Gambau, Verónica
  • Martín Neira, Manuel
© 2020 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes,creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works., A method for internally calibrating microwave total power radiometers by using only one level of noise injection is presented. It is based on having a previous accurate characterization of the receiver noise temperature, which used de facto as a second calibration standard. The method proves to be at least equivalent to the classical two level, as demonstrated through their intercomparison using the data provided by the Microwave Imaging Radiometer using Aperture Synthesis (MIRAS) on board the European Space Agency Soil Moisture and Ocean Salinity (SMOS) Satellite. The long-term stability in terms of retrieved brightness temperature using both methods has similar trends with a small advantage for the one-point approach proposed here., This work was supported in part by the Euro-pean Space Agency with Deimos Enginheria (Portugal) under SMOSP7 Subcontract DME CP12 2015-005 and in part by the Ministerio deEconomía, Industria y Competitividad,Gobierno de España under ProjectTEC2014-58582-R, Project TEC2017-88850-R, and Project ESP2015-67549-C3-1-R., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Calibration of the MIRAS Radiometers

  • Corbella Sanahuja, Ignasi|||0000-0001-5598-7955
  • Torres Torres, Francisco|||0000-0003-1160-6350
  • Duffo Ubeda, Núria|||0000-0002-9398-3995
  • Durán Martínez, Israel
  • González Gambau, Verónica
  • Oliva Balagué, Roger
  • Closa, Josep
  • Martín Neira, Manuel
© 2018 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes,creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works., The microwave imaging radiometer with aperture synthesis (MIRAS) is formed by 69 total power radiometers, of which three are the noise-injection type. Their calibration is reviewed on the basis of the data gathered during more than eight years of operation. Internally calibrated gain and offset corrections with improved temporal stability are presented. New front-end loss characterization with lower seasonal dependence originated from external temperature swings is also proposed. Finally, a methodology to validate the external calibrations, with the instrument pointing to the cold sky, is developed. It seems to indicate that the change of orientation of the instrument, with associated thermal variations, may induce small changes in the radiometer front-end losses, thus introducing calibration errors., Peer Reviewed
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Wide field of view microwave interferometric radiometer imaging

  • Corbella Sanahuja, Ignasi
  • Torres Torres, Francisco
  • Duffo Ubeda, Núria
  • Durán Martínez, Israel
  • González Gambau, Verónica
  • Martín Neira, Manuel
In microwave interferometric radiometers with a large field of view, as for example the Microwave Imaging Radiometer with Aperture Synthesis (MIRAS) onboard the Soil Moisture and Ocean Salinity (SMOS) satellite, one of the major causes of reconstruction error is the contribution to the visibility of the brightness temperature outside the fundamental period, defined on the basis of reciprocal grids. A mitigation method consisting of estimating this contribution through the application of a brightness temperature model outside the fundamental period is proposed. The main advantage is that it does not require any a posteriori addition of artificial scenes to the reconstructed image. Additionally, a method to avoid the sophisticated matrix regularization and inversion techniques usually applied in microwave interferometry is presented. Image reconstruction algorithms are implemented on a minimum grid size in order to maximize their numerical efficiency. An improved method to apply an apodization window to the reconstructed image for reducing Gibbs oscillations is also proposed. All procedures are generally described considering the single polarization case and successively implemented applying the MIRAS layout in both its single polarization and full polarimetric modes. Results show similar performance of the proposed algorithm with respect to the nominal one applied by SMOS. All algorithms are implemented in the MIRAS Testing Software and have been successfully used for scientific studies by other teams., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Calibration of the MIRAS Radiometers

  • Corbella Sanahuja, Ignasi
  • Torres Torres, Francisco
  • Duffo Ubeda, Núria
  • Durán Martínez, Israel
  • González Gambau, Verónica
  • Oliva Balagué, Roger
  • Closa, Josep
  • Martín Neira, Manuel
© 2018 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes,creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works., The microwave imaging radiometer with aperture synthesis (MIRAS) is formed by 69 total power radiometers, of which three are the noise-injection type. Their calibration is reviewed on the basis of the data gathered during more than eight years of operation. Internally calibrated gain and offset corrections with improved temporal stability are presented. New front-end loss characterization with lower seasonal dependence originated from external temperature swings is also proposed. Finally, a methodology to validate the external calibrations, with the instrument pointing to the cold sky, is developed. It seems to indicate that the change of orientation of the instrument, with associated thermal variations, may induce small changes in the radiometer front-end losses, thus introducing calibration errors., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

One-point microwave radiometer calibration

  • Corbella Sanahuja, Ignasi
  • Torres Torres, Francisco
  • Closa Soteras, Josep
  • Duffo Ubeda, Núria
  • Durán Martínez, Israel
  • González Gambau, Verónica
  • Martín Neira, Manuel
© 2020 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes,creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works., A method for internally calibrating microwave total power radiometers by using only one level of noise injection is presented. It is based on having a previous accurate characterization of the receiver noise temperature, which used de facto as a second calibration standard. The method proves to be at least equivalent to the classical two level, as demonstrated through their intercomparison using the data provided by the Microwave Imaging Radiometer using Aperture Synthesis (MIRAS) on board the European Space Agency Soil Moisture and Ocean Salinity (SMOS) Satellite. The long-term stability in terms of retrieved brightness temperature using both methods has similar trends with a small advantage for the one-point approach proposed here., This work was supported in part by the Euro-pean Space Agency with Deimos Enginheria (Portugal) under SMOSP7 Subcontract DME CP12 2015-005 and in part by the Ministerio deEconomía, Industria y Competitividad,Gobierno de España under ProjectTEC2014-58582-R, Project TEC2017-88850-R, and Project ESP2015-67549-C3-1-R., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Dielectric properties of colon polyps, cancer, and normal mucosa: Ex vivo measurements from 0.5 to 20 GHz

  • Guardiola, Marta
  • Buitrago, Santiago
  • Fernández-Esparrach, Gloria
  • O’Callaghan, Joan M.
  • Romeu, Jordi
  • Cuatrecasas, Miriam
  • Córdova, Henry
  • González Ballester, Miguel Ángel, 1973-
  • Camara, Oscar
Purpose: Colorectal cancer is highly preventable by detecting and removing polyps, which are the precursors. Currently, the most accurate test is colonoscopy, but still misses 22% of polyps due to visualization limitations. In this paper, we preliminary assess the potential of microwave imaging and dielectric properties (e.g., complex permittivity) as a complementary method for detecting polyps and cancer tissue in the colon. The dielectric properties of biological tissues have been used in a wide variety of applications, including safety assessment of wireless technologies and design of medical diagnostic or therapeutic techniques (microwave imaging, hyperthermia, and ablation). The main purpose of this work is to measure the complex permittivity of different types of colon polyps, cancer, and normal mucosa in ex vivo human samples to study if the dielectric properties are appropriate for classification purposes. Methods: The complex permittivity of freshly excised healthy colon tissue, cancer, and histological samples of different types of polyps from 23 patients was characterized using an open-ended coaxial probe between 0.5 and 20 GHz. The obtained measurements were classified into five tissue groups before applying a data reduction step with a frequency dispersive single-pole Debye model. The classification was finally compared with pathological analysis of tissue samples, which is the gold standard. Results: The complex permittivity progressively increases as the tissue degenerates from normal to cancer. When comparing to the gold-standard histological tissue analysis, the sensitivity and specificity of the proposed method is the following: 100% and 95% for cancer diagnosis; 91% and 62% for adenomas with high-grade dysplasia; 100% and 61% for adenomas with low-grade dysplasia; and 100% and 74% for hyperplastic polyps, respectively. In addition, complex permittivity measurements were independent of the lesion shape and size, which is also an interesting property comparing to current colonoscopy techniques. Conclusions: The contrast in complex permittivities between normal and abnormal colon tissues presented here for the first time demonstrate the potential of these measurements for tissue classification. It also opens the door to the development of a microwave endoscopic device to complement the outcomes of colonoscopy with functional tissue information., This work was supported by the Department of Universitats, Recerca i Societat de la Informacio of the Catalan Government through Llavor 2014LLAV00016 and producte 2016PROD00068 projects, La Caixa through Caixaimpulse program CI16-00058, the Spanish Comision Interministerial de Ciencia y Tecnologıa (CICYT) under projects TEC2016- 78028-C3-1-P, TEC2014-58582-R, the Spanish Agencia Estatal de Investigacion Unidad de Excelencia Maria de Maeztu (MDM-2016-0600), the Spanish Ministerio de Economıa, Industria y Competitividad, DTS17/00090 and CERCA Programme/Generalitat de Catalunya.