Skip to main content

DESARROLLO DE ARQUITECTURAS Y TECNOLOGIAS FUTURAS HACIA LA RED 5G

TEC2014-60258-C2-1-R

•
Funding agency name Ministerio de Economía y Competitividad
Funding agency acronym MINECO
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos I+D+i Retos de Investigación
Call year 2014
State Plan 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Management unit Secretaría de Estado de Educación, Formación Profesional y Universidades
Beneficiary centre UNIVERSITAT POLITÈCNICA DE VALÈNCIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 21
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Initial UWB in-body channel characterization using a novel multilayer phantom measurement setup

  • Pérez-Simbor, Sofia
  • Barbi, Martina
  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
  • Castelló-Palacios, Sergio|||0000-0003-4689-652X
  • Cardona Marcet, Narciso|||0000-0001-5697-1453
[EN] Wireless Body Area Networks (WBANs) are a promising technology for medical purposes. Currently the WBAN are classified into: implanted (in-), surface (on-) or outside (off-) body communications regarding the location of the devices with reference to the human body. The Ultra Wide-Band (UWB) frequency band is growing as a band of interest for implanted communications because of its high data rate and low power consumption among other benefits. Software simulations, in-vivo measurements and experimental phantom measurements are common methods to properly characterize the propagation channel. Nevertheless, up to now, experimental phantoms measurements presented in the literature show some inconveniences, i.e., the accuracy of the phantoms compared with the real human tissues or the testbed used for the measurements. This paper aims at overcoming these issues using accurate phantoms designed for the purpose of implanted communications in the UWB frequency band. In addition, a multilayer phantom container was developed. This container has capacity for two different phantoms, emulating a heterogeneous propagation medium for in-body measurements. Moreover, a novel setup was built for in-body phantom measurements. As a result, an experimental path loss model is presented from the measurements obtained with phantoms. Besides, software simulations mimicking the experimental setup are performed in order to validate the previous results obtained, This work was supported by the European Union's H2020:MSCA:ITN program for the "Wireless In-body Environment Communication-WiBEC" project under the grant agreement no. 675353. this work was also funded by the Programa de Ayudas de Investigación y Desarrollo 8PAID-01-16) from Univeristat Politècnica de València and by the Ministerio de Economía y Competitividad, Spain (TEC2014-60258-C2-1-R), by the European FEDER funds.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Dielectric characterization of healthy and malignant colon tissues in the 0.5 18 GHz frequency band

  • Fornés Leal, Alejandro|||0000-0001-5914-6045
  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
  • Cardona Marcet, Narciso|||0000-0001-5697-1453
  • Frasson, M.
  • Pons Beltrán, Vicente
Several reports over the last few decades have shown that the dielectric properties of healthy and malignant tissues of the same body organ usually show different values. However, no intensive dielectric studies of human colon tissue have been performed, despite colon cancer's being one of the most common types of cancer in the world. In order to provide information regarding this matter, a dielectric characterization of healthy and malignant colon tissues is presented. Measurements are performed on ex vivo surgery samples obtained from 20 patients, using an open-ended coaxial probe in the 0.5 18 GHz frequency band. Results show that the dielectric constant of colon cancerous tissue is 8.8% higher than that of healthy tissues (p = 0.002). Besides, conductivity is about 10.6% higher, but in this case measurements do not have statistical significance (p = 0.038). Performing an analysis per patient, the differences in dielectric constant between healthy and malignant tissues appear systematically. Particularized results for specific frequencies (500 MHz, 900 MHz, 2.45 GHz, 5 GHz, 8.5 GHz and 15 GHz) are also reported. The findings have potential application in early-stage cancer detection and diagnosis, and can be useful in developing new tools for hyperthermia treatments as well as creating electromagnetic models of healthy and cancerous tissues., The authors would like to thank the medical staff of the endoscopy unit of Hospital Universitari i Politecnic La Fe for their assistance in the gathering of tissue samples. This work was supported by Ministerio de Economia y Competitividad, Spain (ref. TEC2014-60258-C2-1-R, TEC2014-56469-REDT), by FEDER funds, and by a UPV-IISLaFe action (CEI-2G, 2014).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Frequency Dependence of UWB In-Body Radio Channel Characteristics

  • Andreu-Estellés, Carlos
  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
  • Castelló-Palacios, Sergio|||0000-0003-4689-652X
  • Vallés Lluch, Ana|||0000-0002-7896-8666
  • Cardona Marcet, Narciso|||0000-0001-5697-1453
[EN] In this letter, a research of ultra-wideband in-body channel by using a high accurate phantom is performed in order to evaluate the impact of frequency dependence of human tissues on the channel characteristics. Hence, a phantom-based measurement campaign from 3.1 to 5.1 GHz has been conducted. From postprocessing data, the path loss is assessed considering subbands of 500 MHz as well as the entire frequency range under test. In addition, the correlation in transmission is computed and discussed., This work was supported in part by the Ministerio de Economia y Competitividad, Spain, under Grant TEC2014-60258-C2-1-R, and in part by the European FEDER funds. (Corresponding author: Carlos Andreu.)
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Non-Coherent Open-Loop MIMO Communications Over Temporally-Correlated Channels

  • Cabrejas Peñuelas, Jorge
  • Roger Varea, Sandra
  • Fouad, Yaser M. M.
  • Gohary, Ramy H.
  • Yanikomeroglu, Halim
  • Calabuig Soler, Daniel|||0000-0003-0611-9902
  • Monserrat del Río, Jose Francisco|||0000-0001-8664-6408
[EN] This paper investigates the use of non-coherent communication techniques for open-loop transmission over temporally-correlated Rayleigh-fading MIMO channels. These techniques perform data detection without knowing the instantaneous channel coefficients. Three non-coherent Multiple Input Multiple Output (MIMO) schemes, namely, differential unitary space-time modulation, differential space-time block code, and Grassmannian signaling, are compared with several state-of-the-art training-based coherent schemes. This paper shows that the non-coherent schemes are meaningful alternatives to training-based communication, specially as the number of transmit antennas increases. In particular, for more than two transmit antennas, non-coherent communication provides a clear advantage in medium to high mobility scenarios., This work was supported in part by the Ministerio de Economia y Competitividad, Spain, under Grant TEC2014-60258-C2-1-R, in part by the European Regional Development Fund, in part by the European Union through the H2020 Project METIS-II under Grant 671680, in part by Huawei Canada Company, Ltd., and in part by the Ontario Ministry of Economic Development and Innovation's through the Ontario Research Fund-Research Excellence Program.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Performance of Hybrid Beamforming for mmW Multi-antenna Systems in Dense Urban Scenarios

  • Gimenez, Sonia
  • Roger, Sandra
  • Baracca, Paolo
  • Braun, Volker
  • Halbauer, Hardy
  • Martín-Sacristán, David|||0000-0002-7781-557X
  • Monserrat del Río, Jose Francisco|||0000-0001-8664-6408
[EN] Among the many proposals to meet the fifth generation (5G) data rate demands, current spectrum scarcity has motivated the use of millimeter-Wave (mmW) bands for cellular communication. It is well known that mmW communication involves many propagation challenges, which can be compensated through massive multi-antenna techniques. However, implementing fully digital precoding schemes with massive arrays entails huge complexity and costs, which have recently boosted the interest for hybrid beamforming solutions. Although hybrid schemes have shown good performance in simplified setups, their suitability for realistic cellular systems with many interfering base stations and users is still unclear. In this sense, this paper assesses the performance of hybrid beamforming in a dense urban cellular system with a realistic mmW channel model and shows that it can reach the performance of fully digital maximum ratio transmission under line of sight conditions and with a sufficient number of parallel radio-frequency chains. Another important result is that multi-user hybrid beamforming provides a substantial capacity increase with respect to its single-user (SU) counterpart. This finding complements the views on mmW communication usage, which has been so far mainly intended for SU communication to provide high beamforming gains., The research done by P. Baracca, V. Braun, and H. Halbauer leading to these results received funding from the European Commission H2020 programme under grant agreement number 671650 (mmMAGIC project). The work carried out at the Universitat Politecnica de Valencia was supported by the Ministerio de Economia y Competitividad, Spain (TEC2014-60258-C2-1-R), by the European FEDER funds.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Localization for capsule endoscopy at UWB frequencies using an experimental multilayer phantom

  • Barbi, Martina
  • Pérez Simbor, Sofía
  • Andreu Estellés, Carlos
  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
  • Cardona Marcet, Narciso|||0000-0001-5697-1453
[EN] Localization inside the human body using ultrawideband (UWB) wireless technology is gaining importance in several medical applications such as capsule endoscopy. Performance analysis of RF based localization techniques are mainly conducted through simulations using numerical human models or through experimental measurements using homogeneous phantoms. One of the most common implemented RF localization approaches uses the received signal strength (RSS). However, to the best of our knowledge, no experimental measurements employing multilayer phantoms are currently available in literature. This paper investigates the performance of RSS-based technique for two-dimensional (2D) localization by employing a two-layer experimental phantom-based setup. Preliminary results on the estimation of the in-body antenna coordinates show that RSS-based method can achieve a location accuracy on average of 0.5-1 cm within a certain range of distances between in-body and on-body antenna., This work was supported by the European Union’s H2020:MSCA:ITN program for the ”Wireless In-body Environment Communication- WiBEC” project under the grant agreement no. 675353. This work was also funded by the Programa de Ayudas de Investigación y Desarrollo (PAID-01-16) from Universitat Politècnica de València and by the Ministerio de Economía y Competitividad, Spain (TEC2014-60258-C2-1-R), by the European FEDER funds.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Impact of Receivers Location on the Accuracy of Capsule Endoscope Localization

  • Barbi, Martina
  • Andrea Nevárez
  • Vicente Pons Beltrán
  • Frasson, Matteo
  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
  • Cardona Marcet, Narciso|||0000-0001-5697-1453
[EN] In recent years, localization for capsule endoscopy applications using Ultra-Wideband (UWB) technology has become an attractive field of study due to its potential benefits for patients. Performance analysis of RF-based localization techniques are very limited in literature. Most of the available studies rely on software simulations using digital human models. Nonetheless, no realistic studies based on in-vivo measurements has been reported yet. This paper investigates the performance of RSS-based technique for three-dimensional (3D) localization in the UWB frequency band. Impact of receivers selection as well as of the evaluated path loss model on the localization accuracy is investigated. Results obtained through CST-based simulations and from recently conducted in-vivo measurements are presented and compared., This work was supported by the European Union's H2020:MSCA:ITN program for the "Wireless In-body Environment Communication- WiBEC" project under the grant agreement no. 675353. This work was also funded by the Ministerio de Economia y Competitividad, Spain (TEC2014-60258-C2-1-R), by the European FEDER funds.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Spectrum Sharing for LTE-A and DTT: Field Trials of an Indoor LTE-A Femtocell in DVB-T2 Service Area

  • Martínez Pinzón, Gerardo
  • Ribadeneira-Ramírez, Jefferson Alexander
  • Cardona Marcet, Narciso|||0000-0001-5697-1453
  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
  • Fornés Leal, Alejandro|||0000-0001-5914-6045
In this paper, we study a particular case which goes a step beyond the previous ones, as it aims at sharing the same frequency band in the same area between long term evolution-advance (LTE-A) and digital video broadcasting-terrestrial second generation (DVB-T2) technologies. Those geographical areas that are not covered because the useful DTT signal is obstructed by the environment or it has a limited coverage by the network design can be called micro-TVWS. We assume that a DVB-T2 transmitter provides coverage for fixed rooftop reception as a primary service, to a building in which a LTE-A femtocell is installed indoors for local coverage, as a secondary service. The results have been obtained by laboratory emulation and validated through field measurements using professional equipment. Our results provide the technical restrictions of the LTE-A femtocell, mainly on the maximum allowable effective isotropic radiated power that could transmit on the DTT band in terms of carrier separation, from co-channel to adjacent band. These results meet the need of spectrum for IMT-Advanced technologies, so spectrum sharing is proposed in this paper as a new solution to make an efficient use of this resource., This work was supported in part by the Ministerio de Educacion y Ciencia, Spain, under Grant "DEFINE5G" TEC2014-60258-C2-1-R and Grant "ARCO5G" TEC2014-56469-REDT, and in part by the European FEDER Funds.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Tailor-Made Tissue Phantoms Based on Acetonitrile Solutions for Microwave Applications up to 18 GHz

  • Castelló-Palacios, Sergio|||0000-0003-4689-652X
  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
  • Fornés Leal, Alejandro|||0000-0001-5914-6045
  • Cardona Marcet, Narciso|||0000-0001-5697-1453
  • Vallés Lluch, Ana|||0000-0002-7896-8666
Tissue-equivalent phantoms play a key role in the development of new wireless communication devices that are tested on such phantoms prior to their commercialization. However, existing phantoms cover a small number of tissues and do not reproduce them accurately within wide frequency bands. This paper aims at enlarging the number of mimicked tissues as well as their working frequency band. Thus, a variety of potential compounds are scanned according to their relative permittivity from 0.5 to 18 GHz. Next, a combination of these compounds is characterized so the relation between their dielectric properties and composition is provided. Finally, taking advantage of the previous analysis, tailor-made phantoms are developed for different human tissues up to 18 GHz and particularized for the main current body area network (BAN) operating bands. The tailor-made phantoms presented here exhibit such a high accuracy as would allow researchers and manufacturers to test microwave devices at high frequencies for large bandwidths as well as the use of heterogeneous phantoms in the near future. The key to these phantoms lies in the incorporation of acetonitrile to aqueous solutions. Such compounds have a suitable behavior to achieve the relative permittivity values of body tissues within the studied frequency band., This work was supported by the Ministerio de Economia y Competitividad, Spain (TEC2014-60258-C2-1-R) and by the European FEDER Funds.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Formulas for easy-to-prepare tailored phantoms at 2.4 GHz ISM band

  • Castelló-Palacios, Sergio|||0000-0003-4689-652X
  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
  • Fornés Leal, Alejandro|||0000-0001-5914-6045
  • Cardona Marcet, Narciso|||0000-0001-5697-1453
  • Vallés Lluch, Ana|||0000-0002-7896-8666
[EN] Emerging integration of communication networks into wearable or implantable body devices involves a challenge due to the transmitting medium, the body itself. This medium is heterogeneous and lossier than air, so devices that are supposed to work on it should be tested in tissue-equivalent materials. A number of materials with the electromagnetic response of body tissues have been proposed. Most of them are sucrose aqueous solutions that are supposed to simulate human's muscle tissue mainly within medical frequency bands. However, these recipes are restricted to a single tissue and it is difficult to adapt them to fit the permittivity values of different body tissues. The significance of this study lies in the development of a mathematical relationship that models the dielectric properties of an aqueous solution according to the concentration of sugar and salt at 2.4 GHz, the frequency around which an Industrial, Scientific and Medical (ISM) band is placed. Thus, it becomes possible to create custom-made phantoms with simple and accessible ingredients that are easy to prepare in any laboratory., This work was supported by the Ministerio de Economia y Competitividad, Spain (TEC2014-60258-C2-1-R) and by the European FEDER Funds.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Multicarrier Waveform Harmonization and Complexity Analysis for an Efficient 5G Air Interface Implementation

  • Garcia-Roger, David
  • Roger Varea, Sandra
  • Flores De Valgas, Josue
  • Monserrat del Río, Jose Francisco|||0000-0001-8664-6408
[EN] The coexistence of multiple air interface variants in the upcoming fifth generation (5G) wireless technology remains a matter of ongoing discussion. This paper focuses on the physical layer of the 5G air interface and provides a harmonization solution for the joint implementation of several multicarrier waveform candidates. Waveforms based either on cyclic prefix-orthogonal frequency division multiplexing (CP-OFDM) or on filter bank multicarrier (FBMC) are first presented through a harmonized system model. Complexity comparisons among five different waveforms are provided. Then, the complexity of a proposed configurable hardware implementation setup for waveform transmission and reception is evaluated. As a result, the harmonized transmitter and receiver exhibit 25¿40% and 15¿25% less complexity in floating-point operations, respectively, in comparison to two standalone implementations of the most complex waveform instances of the CP-OFDM and FBMC families. This highlights the similarities between both families and illustrates the component reuse advantages associated with the proposed harmonized solution., This work was performed in the framework of the H2020 Project METIS-II with reference 671680, which is partly funded by the European Union. The authors would like to acknowledge the contributions of their colleagues in METIS-II. This work was also supported in part by the Ministerio de Economia y Competitividad, under Grant TEC2014-60258-C2-1-R.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Accurate broadband measurement of electromagnetic tissue phantoms using open-ended coaxial systems

  • Fornés Leal, Alejandro|||0000-0001-5914-6045
  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
  • Castelló-Palacios, Sergio|||0000-0003-4689-652X
  • Vallés Lluch, Ana|||0000-0002-7896-8666
  • Cardona Marcet, Narciso|||0000-0001-5697-1453
[EN] New technologies and devices for wireless communication networks are continually developed. In order to assess their performance, they have to be tested in realistic environments taking into account the influence of the body in wireless communications. Thus, the development of phantoms, which are synthetic materials that can emulate accurately the electromagnetic behaviour of different tissues, is mandatory. An accurate dielectric measurement of these phantoms requires using a measurement method with a low uncertainty. The open-ended coaxial technique is the most spread technique but its accuracy is strongly conditioned by the calibration procedure. A typical calibration is performed using an open circuit, a short circuit and water. However, this basic calibration is not the most accurate approach for measuring all kinds of materials. In this paper, an uncertainty analysis of the calibration process of open-ended coaxial characterization systems when a polar liquid is added to the typical calibration is provided. Measurements are performed on electromagnetically well-known liquids in the 0.5 - 8.5 GHz band. Results show that adding methanol improves the accuracy in the whole solution domain of the system, mainly when measuring phantoms that mimic high water content tissues, whereas ethanol is more suitable for measuring low water content tissue phantoms., This work was supported by the Ministerio de Educacion y Ciencia, Spain (ref. TEC2014-60258-C2-1-R, TEC2014-56469-REDT), by the European FEDER funds.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Doppler Characterization in Ultra Wideband BAN Channels During Breathing

  • García-Serna, Rubén Gregorio
  • Molina-García-Pardo, José María
  • JUAN LLACER, LEANDRO
  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
  • Cardona Marcet, Narciso|||0000-0001-5697-1453
[EN] Monitoring the physical parameters from devices inside the body, using ultra wideband (UWB) technology, enables the development of high bandwidth demanding applications in real time. The relative movement of the nodes deployed in the body, due to breathing, can give rise to a frequency shifting effect, increasing the fading level in the propagation channel during transmissions. In this article, therefore, we present a study of the frequency effects on the propagation channel derived from the relative movement between two nodes of a wireless body area network (WBAN), at least one of them placed inside the human body, caused by breathing. The study is performed on the basis of the Doppler spectrum characterization in terms of the shape fitting and frequency spread parameter derivation. Continuous wave (CW) signals have been used to cover the UWB range at four selected frequencies: 3.1, 4.8, 6, and 8.5 GHz, and a liquid phantom has been employed for emulating the dielectric properties of the high water content tissues at the considered UWB frequencies., This work was supported in part by the Ministerio de Economia y Competitividad (MINECO), Spain, under Grant TEC2016-78028-C3-2-P, in part by the European Union's H2020-MSCA-ITN Program by the "mmWave Communications in the Built Environments-WaveComBE" Project, under Grant 766231, and in part by the European FEDER funds.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Performance evaluation of analog beamforming with hardware impairments for mmW massive MIMO communication in an urban scenario

  • Giménez Colás, Sonia
  • Roger Varea, Sandra
  • Baracca, Paolo
  • Braun, Volker
  • Halbauer, Hardy
  • Martín-Sacristán, David|||0000-0002-7781-557X
  • Monserrat del Río, Jose Francisco|||0000-0001-8664-6408
[EN] The use of massive multiple-input multiple-output (MIMO) techniques for communication at millimeter-Wave (mmW) frequency bands has become a key enabler to meet the data rate demands of the upcoming fifth generation (5G) cellular systems. In particular, analog and hybrid beamforming solutions are receiving increasing attention as less expensive and more power efficient alternatives to fully digital precoding schemes. Despite their proven good performance in simple setups, their suitability for realistic cellular systems with many interfering base stations and users is still unclear. Furthermore, the performance of massive MIMO beamforming and precoding methods are in practice also affected by practical limitations and hardware constraints. In this sense, this paper assesses the performance of digital precoding and analog beamforming in an urban cellular system with an accurate mmW channel model under both ideal and realistic assumptions. The results show that analog beamforming can reach the performance of fully digital maximum ratio transmission under line of sight conditions and with a sufficient number of parallel radio-frequency (RF) chains, especially when the practical limitations of outdated channel information and per antenna power constraints are considered. This work also shows the impact of the phase shifter errors and combiner losses introduced by real phase shifter and combiner implementations over analog beamforming, where the former ones have minor impact on the performance, while the latter ones determine the optimum number of RF chains to be used in practice., The research done by P. Baracca, V. Braun, and H. Halbauer leading to these results received funding from the European Commission H2020 programme under grant agreement number 671650 (mmMAGIC project). The work carried out at the Universitat Politècnica de València was supported by the Ministerio de Economia y Competitividad, Spain (TEC2014-60258-C2-1-R) by the European FEDER funds.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

UWB Path Loss Models for Ingestible Devices

  • Pérez-Simbor, Sofia
  • Andreu-Estellés, Carlos
  • Frasson, Matteo
  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
  • Cardona Marcet, Narciso|||0000-0001-5697-1453
[EN] Currently, some medical devices such as the Wireless Capsule Endoscopy (WCE) are used for data transmission from inside to outside the body. Nevertheless, for certain applications such as WCE, the data rates offered by current medical frequency bands can result insufficient. Ultra Wideband (UWB) frequency band has become an interesting solution for this. However, to date, there is not a formal channel path loss model for the UWB frequency band in the gastrointestinal (GI) scenario due to the huge differences between the proposed studies. There are three main methodologies to characterize the propagation channel, software simulations and experimental measurements either in phantom or in in vivo animals. Previous works do not compare all the methodologies or present some disagreements with the literature. In this paper, a dedicated study of the path loss using the three methodologies aforementioned (simulations, phantoms and in vivo measurements) and a comparison with previous researches in the literature is performed. Moreover, numerical values for a path loss model which agrees with the three methodologies and the literature are proposed. This paper aims at being the starting point for a formal path loss model in the UWB frequency band for WBANs in the GI scenario, This work was supported in part by the European Union's H2020-MSCA-ITN Program for the "Wireless In-body Environment Communication" Project under Grant 675353, in part by the Programa de Ayudas de Investigacion y Desarrollo (PAID-01-16) from Universitat Politecnica de Valencia, and in part by the Ministerio de Economia y Competitividad, Spain under Grant TEC2014-60258-C2-1-R through the European FEDER Funds.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Wideband phantoms of different body tissues for heterogeneous models in body area networks

  • Castelló-Palacios, Sergio|||0000-0003-4689-652X
  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
  • Fornés Leal, Alejandro|||0000-0001-5914-6045
  • Cardona Marcet, Narciso|||0000-0001-5697-1453
  • Vallés Lluch, Ana|||0000-0002-7896-8666
[EN] One of the key issues about wireless technologies is their interaction with the human body. The so-called internet of things will comprise many devices that will transmit either around or through the human body. These devices must be tested either in their working medium, when possible, or in the most realistic one. For this purpose, tissue-like phantoms are the best alternative to carry out realistic analyses of the performance of body area networks. In addition, they are the conventional way to certify the compliance of commercial standards by these devices. However, the number of phantoms that work in large bandwidths is limited in literature. This work aims at presenting chemical solutions that will be useful to prepare a variety of wideband tissue phantoms. Besides, the colon was mimicked in two ways, the healthy tissue and the malignant one, taking into account studies that relate changes on the relative permittivity with cancer. They were designed on the basis of acetonitrile in aqueous solutions as described in a previous work. Thus, many scenarios could be developed such as multilayers which imitate parts of the heterogeneous body., Research supported by the Programa de Ayudas de Investigación y Desarrollo (PAID-01-16) from Universitat Politècnica de València, by the Ministerio de Economía y Competitividad, Spain (TEC2014-60258-C2-1- R) and by the European FEDER Funds.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Spatial In-Body Channel Characterization Using an Accurate UWB Phantom

  • Andreu Estellés, Carlos
  • Castelló-Palacios, Sergio|||0000-0003-4689-652X
  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
  • Fornés Leal, Alejandro|||0000-0001-5914-6045
  • Vallés Lluch, Ana|||0000-0002-7896-8666
  • Cardona Marcet, Narciso|||0000-0001-5697-1453
Ultra-wideband (UWB) systems have emerged as a possible solution for future wireless in-body communications. However, in-body channel characterization is complex. Animal experimentation is usually restricted. Furthermore, software simulations can be expensive and imply a high computational cost. Synthetic chemical solutions, known as phantoms, can be used to solve this issue. However, achieving a reliable UWB phantom can be challenging since UWB systems use a large bandwidth and the relative permittivity of human tissues are frequency dependent. In this paper, a measurement campaign within 3.1-8.5 GHz using a new UWB phantom is performed. Currently, this phantom achieves the best known approximation to the permittivity of human muscle in the whole UWB band. Measurements were performed in different spatial positions, in order to also investigate the diversity of the in-body channel in the spatial domain. Two experimental in-body to in-body (IB2IB) and in-body to on-body (IB2OB) scenarios are considered. From the measurements, new path loss models are obtained. Besides, the correlation in transmission and reception is computed for both scenarios. Our results show a highly uncorrelated channel in transmission for the IB2IB scenario at all locations. Nevertheless, for the IB2OB scenario, the correlation varies depending on the position of the receiver and transmitter., This work was supported by the Ministerio de Economia y Competitividad, Spain, under Grant TEC2014-60258-C2-1-R and Grant TEC2014-56469-REDT and by the European FEDER Funds.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Experimental Assessment of Time Reversal for In-Body to In-Body UWB Communications

  • Andreu-Estellés, Carlos
  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
  • Castelló-Palacios, Sergio|||0000-0003-4689-652X
  • Cardona Marcet, Narciso|||0000-0001-5697-1453
[EN] The standard of in-body communications is limited to the use of narrowband systems. These systems are far from the high data rate connections achieved by other wireless telecommunication services today in force. The UWB frequency band has been proposed as a possible candidate for future in-body networks. However, the attenuation of body tissues at gigahertz frequencies could be a serious drawback. Experimental measurements for channel modeling are not easy to carry out, while the use of humans is practically forbidden. Sophisticated simulation tools could provide inaccurate results since they are not able to reproduce all the in-body channel conditions. Chemical solutions known as phantoms could provide a fair approximation of body tissues¿ behavior. In this work, the Time Reversal technique is assessed to increase the channel performance of in-body communications. For this task, a large volume of experimental measurements is performed at the low part of UWB spectrum (3.1-5.1 GHz) by using a highly accurate phantom-based measurement setup. This experimental setup emulates an in-body to in-body scenario, where all the nodes are implanted inside the body. Moreover, the in-body channel characteristics such as the path loss, the correlation in transmission and reception, and the reciprocity of the channel are assessed and discussed., This work was supported by the Programa de Ayudas de Investigacion y Desarrollo (PAID-01-16) from Universitat Politecnica de Valencia and by the Ministerio de Economia y Competitividad, Spain (TEC2014-60258-C2-1-R), by the European FEDER funds.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Ultrawideband Technology for Medical In-Body Sensor Networks: An Overview of the Human Body as a Propagation Medium, Phantoms, and Approaches for Propagation Analysis

  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
  • Fornés Leal, Alejandro|||0000-0001-5914-6045
  • Castelló-Palacios, Sergio|||0000-0003-4689-652X
  • Vallés Lluch, Ana|||0000-0002-7896-8666
  • Cardona Marcet, Narciso|||0000-0001-5697-1453
  • Andreu-Estellés, Carlos
  • Pérez-Simbor, Sofia
  • Barbi, Martina
[EN] An in-body sensor network is that in which at least one of the sensors is located inside the human body. Such wireless in-body sensors are used mainly in medical applications, collecting and monitoring important parameters for health and disease treatment. IEEE Standard 802.15.6-2012 for wireless body area networks (WBANs) considers in-body communications in the Medical Implant Communications Service (MICS) band. Nevertheless, high-data-rate communications are not feasible at the MICS band because of its narrow occupied bandwidth. In this framework, ultrawideband (UWB) systems have emerged as a potential solution for in-body highdata-rate communications because of their miniaturization capabilities and low power consumption., This work was supported by the Programa de Ayudas de Investigación y Desarrollo (PAID-01-16) at the Universitat Politècnica de València, Spain; by the Ministerio de Economía y Competitividad, Spain (TEC2014-60258-C2-1-R); and by the European FEDER funds. It was also funded by the European Union’s H2020:MSCA:ITN program for the Wireless In-Body Environ-ment Communication–WiBEC project under grant 675353.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Distributed Hybrid Precoding for Indoor Deployments Using Millimeter Wave Band

  • Giménez Colás, Sonia
  • Roger Varea, Sandra
  • Calabuig Soler, Daniel|||0000-0003-0611-9902
  • Monserrat del Río, Jose Francisco|||0000-0001-8664-6408
  • Cardona Marcet, Narciso|||0000-0001-5697-1453
[EN] DistributedAntenna Systems (DAS) are an alternative of network deployment that allows reducing the distance between transmitter and receiver by distributing the antennas throughout the coverage area. Moreover, the performance of the millimeter wave (mmWave) band can be significantly high within short transmitter-receiver distances. In this paper, the potential benefits of DAS deployments in the mmWave band are studied. To this aim, a distributed hybrid precoding (DHP) solution with remote antenna unit (RAU) selection capabilities is proposed and analyzed in an indoor DAS working in mmWaves and compared to two other indoor deployment strategies: a conventional cellular system with colocated antenna arrays and a small cell deployment. Theresults show that, using DHP, DAS not only brings huge gains to cell-edge users rate but also increases system capacity, becoming the best overall deployment. Further simulations including practical limitations have revealed that DAS using DHP is quite robust to combiner losses, although its performance is significantly degraded by outdated channel reports., This work has been supported by Ministerio de Economia y Competitividad, Spain (BES-2012-055975 and TEC2014-60258-C2-1-R), and by the European FEDER funds.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

UWB RSS-based Localization for Capsule Endoscopy using a Multilayer Phantom and In Vivo Measurements

  • Barbi, Martina
  • Nevárez, Andrea
  • Pons Beltrán, Vicente
  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
  • Cardona Marcet, Narciso|||0000-0001-5697-1453
[EN] In recent years, the localization for capsule endoscopy applications using ultrawideband (UWB) technology has become an attractive field of investigation due to its potential benefits for patients. The literature concerning performance analysis of radio frequency-based localization techniques for in-body applications at UWB frequencies is very limited. Available studies mainly rely on finite-difference time-domain simulations, using digital human models and on experimental measurements by means of homogeneous phantoms. Nevertheless, no realistic analysis based on multilayer phantom measurements or through in vivo experiment has been reported yet. This paper investigates the performance of the received signal strength-based approach for 2-D and 3-D localizations in the UWB frequency band. For 2-D localization, experimental laboratory measurements using a two-layer phantom-based setup have been conducted. For 3-D localization, data from a recently conducted in vivo experiment have been used. Localization accuracy using path loss models, under ideal and non-ideal channel estimation assumptions, is compared. Results show that, under nonideal channel assumption, the relative localization error slightly increases for the 2-D case but not for the in vivo 3-D case. Impact of receivers selection on the localization accuracy has also been investigated for both 2-D and 3-D cases., This work was supported in part by the European Union's H2020 through the MSCA: ITN Program "Wireless in-Body Environment Communication-WiBEC" under Grant 675353, in part by the Programa de Ayudas de Investigacion y Desarrollo, Universitat Politecnica de Valencia under Grant PAID-01-16, and in part by the Ministerio de Economia y Competitividad, Spain, through the European FEDER Funds under Grant TEC2014-60258-C2-1-R.