Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Techniques for ventricular repolarization instability assessment from the ECG

  • Laguna, Pablo
  • Martínez Cortés, Juan Pablo
  • Pueyo, Esther
Instabilities in ventricular repolarization have been documented to be tightly linked to arrhythmia vulnera- bility. Translation of the information contained in the repolar- ization phase of the electrocardiogram (ECG) into valuable clinical decision-making tools remains challenging. This work aims at providing an overview of the last advances in the pro- posal and quantification of ECG-derived indices that describe repolarization properties and whose alterations are related with threatening arrhythmogenic conditions. A review of the state of the art is provided, spanning from the electrophysio- logical basis of ventricular repolarization to its characteriza- tion on the surface ECG through a set of temporal and spatial risk markers.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Respiratory rate derived from smartphone-camera-acquired pulse photoplethysmographic signals

  • Lázaro Plaza, Jesús
  • Nam, Yunyoung
  • Gil Herrando, Eduardo
  • Laguna Lasaosa, Pablo
  • Chon, Ki
A method for deriving respiratory rate from smartphone-camera-acquired pulse photoplethysmographic (SCPPG) signal is presented. Our method exploits respiratory information by examining the pulse wave velocity and dispersion from the SCPPG waveform and we term these indices as the pulse width variability (PWV). A method to combine information from several derived respiration signals is also presented and it is used to combine PWV information with other methods such as pulse amplitude variability (PAV), pulse rate variability (PRV), and respiration-induced amplitude and frequency modulations (AM and FM) in SCPPG signals Evaluation is performed on a database containing SCPPG signals recorded from 30 subjects during controlled respiration experiments at rates from 0.2 to 0.6 Hz with an increment of 0.1 Hz, using three different devices: iPhone 4S, iPod 5, and HTC One M8. Results suggest that spontaneous respiratory rates (0.2–0.4 Hz) can be estimated from SCPPG signals by the PWV- and PRVbased methods with low relative error (median of order 0.5% and interquartile range of order 2.5%). The accuracy can be improved by combining PWV and PRV with other methods such as PAV, AM and/or FM methods. Combination of these methods yielded low relative error for normal respiratory rates, and Institute of Physics and Engineering in Medicine maintained good performance at higher rates (0.5–0.6 Hz) when using the iPhone 4S or iPod 5 devices.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Difference in pulse arrival time at forehead and at finger as a surrogate of pulse transit time

  • Lazaro, Jesús
  • Bailón, Raquel
  • Laguna, Pablo
  • Marozas, Vaidotas
  • Rapalis, Andrius
  • Gil, Eduardo
Pulse transit time (PTT) difference (PTTD) to the forehead and finger dynamics are compared to pulse arrival time towards the finger (PATF) dynamics during a tilt table test. Two frequency bands, where different physiological information is expected, are analyzed: low frequency (LF) influenced by both sympathetic and parasympathetic activity, and high frequency (HF) influenced by parasympathetic activity. As PATF, PTTD is influenced by PTT, but in contrast to PATF, PTTD is not influenced by the pre-ejection period (PEP). This is advantaging in certain applications such as arterial stiffness assessment or blood pressure estimation. Results showed higher correlation between PTTD and PATF during rest stages than during tilt stage, when the PEP dynamics have stronger effect in PATF dynamics. This suggests that PTTD variability can potentially be a surrogate of PTT variability that is not influenced by PEP, which is advantaging in the previously mentioned applications. However, further studies must be elaborated in order to evaluate the potential of PTTD in such specific applications.