Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 10
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Barium ion sensing with IPG K+ molecular probes

  • Miller, R. L.
  • Byrnes, N.
  • Cameron, C. G.
  • Carlson, A. J.
  • Dey, E.
  • Madigan, R.
  • Medina, J.
  • Melancon, S.
  • Navarro, K. E.
  • Foss, F. W.
  • Jones, B. J. P.
  • Adams, C.
  • Almazan, H.
  • Aranburu, A. I.
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • García-Barrena, Jara
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
[EN] Fluorophores covalently bound to azacrown ether ionophores can be assembled into sensitive turn-on chemosensors. The size specificity and electron-rich nature of the ionophore's binding domain contribute to both selectivity and strong turn-on fluorescence sensing by various mechanisms when properly constructed. Aza-18-crown-6 ethers are quite selective for binding to K+ and Ba2+, yet the more electron-withdrawing dicationic nature of barium imposes a larger electronic effect on turn-on fluorescent sensors. Barium chemosensors can be important for measuring soluble Ba2+ in drinking water and have gained recent attention for their potential to enhance the detection of rare events in xenon decay. Here we quantify the capability of three chemosensors, marketed for biologically useful K+ sensing, as effective probes for Ba2+ ions. We present measurements from bulk spectrofluorometry to characterize the system in aqueous solutions and demonstrate the usefulness of these species for low-background single-ion fluorescence microscopy, revealing new candidates for Ba2+ sensing., Our program of single metal ion sensing is a part of a collaborative project to employ SMFI chemosensors functional at the solid-gas interface as R&D toward barium tagging for the NEXT experiment. We thank ION Biosciences for supplying the IPG dyes used in these experiments and also for technical support on their best use. We acknowledge support from the US National Science Foundation under award number NSF CHE 2004111 and the Robert A Welch Foundation under award number Y-2031-20200401 (University of Texas Arlington) and the US Department of Energy under awards DE-SC0019054 and DE-SC0019223. The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under Grant Agreement No. 951281-BOLD; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under Grant Agreement No. 957202-HIDDEN; the MCIN/AEI of Spain and ERDF A way of making Europe under grants RTI2018-095979 and PID2021-125475NB, the Severo Ochoa Program grant CEX2018-000867-S and the Ramon y Cajal program grant RYC-2015-18820; the Generalitat Valenciana of Spain under grants PROMETEO/2021/087 and CIDEGENT/2019/049; the Department of Education of the Basque Government of Spain under the predoctoral training program non-doctoral research personnel; the Portuguese FCT under project UID/FIS/04559/2020 to fund the activities of LIBPhys-UC; the Pazy Foundation (Israel) under grants 877040 and 877041; the US Department of Energy under contracts number DE-AC02-06CH11357 (Argonne National Laboratory) and DE-AC02-07CH11359 (Fermi National Accelerator Laboratory). Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Demonstration of neutrinoless double beta decay searches in gaseous xenon with NEXT

  • Novella, P.
  • Sorel, M.
  • Usón, A.
  • Adams, C.
  • Almazán, H.
  • Aparicio, B.
  • Aranburu, A. I.
  • Arazi, L.
  • Arnquist, I.J.
  • Auria-Luna, F
  • Ayet, S.
  • C.D.R. Azevedo
  • Bailey, K.
  • Rodriguez-Samaniego, Javier
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] The NEXT experiment aims at the sensitive search of the neutrinoless double beta decay in Xe-136, using high-pressure gas electroluminescent time projection chambers. The NEXT-White detector is the first radiopure demonstrator of this technology, operated in the Laboratorio Subterr & aacute;neo de Canfranc. Achieving an energy resolution of 1% FWHM at 2.6 MeV and further background rejection by means of the topology of the reconstructed tracks, NEXT-White has been exploited beyond its original goals in order to perform a neu-trinoless double beta decay search. The analysis considers the combination of 271.6 days of Xe-136-enriched data and 208.9 days of 136Xe-depleted data. A detailed background mod-eling and measurement has been developed, ensuring the time stability of the radiogenic and cosmogenic contributions across both data samples. Limits to the neutrinoless mode are obtained in two alternative analyses: a background-model-dependent approach and a novel direct background-subtraction technique, offering results with small dependence on the background model assumptions. With a fiducial mass of only 3.50 +/- 0.01 kg of Xe-136-enriched xenon, 90% C.L. lower limits to the neutrinoless double beta decay are found in the T-1/2(0 nu) > 5.5x10(23) -1.3x10(24) yr range, depending on the method. The presented techniques stand as a pro of-of-concept for the searches to be implemented with larger NEXT detectors., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under Grant Agreement No. 951281-BOLD; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under Grant Agreement No. 957202-HIDDEN; the MCIN/AEI of Spain and ERDF A way of making Europe under grants PID2021-125475NB and the Severo Ochoa Program grant CEX2018-000867-S; the Generalitat Valenciana of Spain under grants PROMETEO/2021/087 and CIDEGENT/2019/049; the Department of Education of the Basque Government of Spain under the predoctoral training program non-doctoral research personnel; the Spanish la Caixa Foundation (ID 100010434) under fellowship code LCF/BQ/PI22/11910019; the Portuguese FCT under project UID/FIS/04559/2020 to fund the activities of LIBPhys-UC; the Israel Science Foundation (ISF) under grant 1223/21; the Pazy Foundation (Israel) under grants 310/22, 315/19 and 465; the US Department of Energy under contracts number DE-AC02-06CH11357 (Argonne National Laboratory), DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M), DE-SC0019054 (Texas Arlington) and DE-SC0019223 (Texas Arlington); the US National Science Foundation under award number NSF CHE 2004111; the Robert A Welch Foundation under award number Y-2031-20200401. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Data Compression in the NEXT-100 Data Acquisition System

  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
  • Rodríguez Ponce, Jorge
  • Simón Estévez, Ander
  • Benlloch Rodríguez, José María
[EN] NEXT collaboration detectors are based on energy measured by an array of photomultipliers (PMT) and topological event filtering based on an array of silicon photomultipliers (SiPMs). The readout of the PMT sensors for low-frequency noise effects and detector safety issues requires a grounded cathode connection that makes the readout AC-couple with variations in the signal baseline. Strict detector requirements of energy resolution better than 1% FWHM require a precise baseline reconstruction that is performed offline for data analysis and detector performance characterization. Baseline variations make it inefficient to apply traditional lossy data compression techniques, such as zero-suppression, that help to minimize data throughput and, therefore, the dead time of the system. However, for the readout of the SiPM sensors with less demanding requirements in terms of accuracy, a traditional zero-suppression is currently applied with a configuration that allows for a compression ratio of around 71%. The third stage in the NEXT detectors program, the NEXT-100 detector, is a 100 kg detector that instruments approximately five times more PMT sensors and twice the number of SiPM sensors than its predecessor, the NEXT-White detector, putting more pressure in the DAQ throughput, expected to be over 900 MB/s with the current configuration, which will worsen the dead time of the acquisition data system. This paper describes the data compression techniques applied to the sensor data in the NEXT-100 detector, which reduces data throughput and minimizes dead time while maintaining the event rate to the level of its predecessor, around 50 Hz., NEXT collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under Grant Agreement No. 951281-BOLD; the European Research Council (ERC) under Grant Agreement No. 101039048-GanESS; the European Union's Framework Program for Research and Innovation Horizon 2020 (2014-2020) under Grant Agreement No. 957202-HIDDEN; the MCIN/AEI/10.13039/501100011033 of Spain and ERDF A way of making Europe under grant RTI2018-095979, the Severo Ochoa Program grant CEX2018-000867-S and the Maria de Maeztu Program grant MDM-2016-0692; the Generalitat Valenciana of Spain under grants PROMETEO/2021/087 and CIDEGENT/2019/049; the Portuguese FCT under project UID/FIS/04559/2020 to fund the activities of LIBPhys-UC; the Pazy Foundation (Israel) under grants 877040 and 877041; the US Department of Energy under contract number DE-AC02-06CH11357 (Argonne National Laboratory), DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M), DE-SC0019054 (Texas Arlington) and DE-SC0019223 (Texas Arlington); the US National Science Foundation under award number NSF CHE 2004111; the Robert A Welch Foundation under award number Y-2031-20200401. A.S.E acknowledges support from the Kreitman School of Advanced Graduate Studies at Ben-Gurion University and from the Marie Sklodowska-Curie grant agreement No. 101026628. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Ion transport on phased radiofrequency carpets in xenon gas

  • Dey, E.
  • Jones, B. J. P.
  • Mei, Y.
  • Brodeur, M.
  • Chirayath, V. A.
  • Coward, N.
  • Foss, F. W.
  • Navarro, K. E.
  • Parmaksiz, I.
  • Adams, C.
  • Almazán, H.
  • Aparicio, B.
  • Aranburu, A. I.
  • Arazi, L.
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • García-Barrena, Jara
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] We present the design and performance of a four-phased radiofrequency (RF) carpet system for ion transport between 200–600 mbar, significantly higher than previously demonstrated RF carpet applications. The RF carpet, designed with a 160 μm pitch, is applied to the lateral collection of ions in xenon at pressures up to 600 mbar. We demonstrate transport efficiency of caesium ions across varying pressures, and compare with microscopic simulations made in the SIMION package. The novel use of an N-phased RF carpet can achieve ion levitation and controlled lateral motion in a denser environment than is typical for RF ion transport in gases. This feature makes such carpets strong candidates for ion transport to single ion sensors envisaged for future neutrinoless double-beta decay experiments in xenon gas., The work in this paper was funded by the US Department of Energy under DE-SC0019054 and DE-SC0019223 to the University of Texas at Arlington. The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under Grant Agreement No. 951281-BOLD; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under Grant Agreement No. 957202-HIDDEN; the MCIN/AEI of Spain and ERDF A way of making Europe under grants PID2021-125475NB and RTI2018-095979, and the Severo Ochoa and Maria de Maeztu Program grants CEX2023-001292-S, CEX2023-001318-M and CEX2018-000867-S; the Generalitat Valenciana of Spain under grants PROMETEO/2021/087 and CISEJI/2023/27; the Department of Education of the Basque Government of Spain under the predoctoral training program non-doctoral research personnel; the Spanish la Caixa Foundation (ID 100010434) under fellowship code LCF/BQ/PI22/11910019; the Portuguese FCT under project UID/FIS/04559/2020 to fund the activities of LIBPhys-UC; the Israel Science Foundation (ISF) under grant 1223/21; the Pazy Foundation (Israel) under grants 310/22, 315/19 and 465; the US Department of Energy under contracts number DE-AC02-06CH11357 (Argonne National Laboratory), DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M), DE-SC0019054 (Texas Arlington) and DE-SC0019223 (Texas Arlington); the US National Science Foundation under award number NSF CHE 2004111; the Robert A Welch Foundation under award number Y-2031-20200401; Deutsche Forschungsgemeinschaft (DFG, German Research Foundation)-AY 155/2-1; MB acknowledge support from the National Science Foundation under grant number PHY-2310059. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

First results of the NEXT-100 detector using 83mKr decays

  • Martinez-Lema, G.
  • Herves Carrete, C.
  • Torelli, S.
  • Cid Laso, M.
  • Vazquez Cabaleiro, P.
  • Palmeiro, B.
  • Hernando Morata, J. A.
  • Gomez-Cadenas, J. J.
  • Adams, C.
  • Almazan, H.
  • Aranburu, A. I.
  • Arazi, L.
  • Arnquist, I. J.
  • Auria-Luna, F.
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • García-Barrena, Jara
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • MARTÍNEZ PÉREZ, ALBERTO
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] The NEXT Collaboration is investigating the double beta decay of ¹³¿Xe using high-pressure gaseous electroluminescent time projection chambers, which provide excellent energy resolution together with a robust topological signature. Operating at the Laboratorio Subterráneo de Canfranc (LSC) and building on the success of the NEXT-White detector, the NEXT-100 apparatus began commissioning in May 2024 and started operation with xenon at a pressure of 4 bar in October 2024. We report here the first results obtained with NEXT-100 using low-energy calibration data from ¿³¿Kr decays, which allow the detector response to be mapped throughout the active volume and its stability to be monitored over time. After homogenizing the light response, we achieve an energy resolution of 4.37% FWHM at 41.5 keV for ¿³¿Kr point-like energy deposits contained within a radius of 425 mm. In a fiducial region representing the operating conditions of NEXT-100 at 10 bar, we obtain an improved energy resolution of 4.16% FWHM. These results are in good agreement with those obtained in NEXT-White, and an E¿¹¿² extrapolation to Q<sub>ßß</sub> yields an energy resolution close to 0.5% FWHM, well below the 1% FWHM design target., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under Grant Agreements No. 951281-BOLD and 101039048-GanESS; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under Grant Agreement No. 860881-HIDDeN; the MCIN/AEI of Spain and ERDF A way of making Europe under grants PID2021-125475NB and RTI2018-095979, and the Severo Ochoa and Maria de Maeztu Program grants CEX2023-001292-S, CEX2023-001318-M and CEX2018-000867-S; the Generalitat Valenciana of Spain under grants PROMETEO/2021/087, ASFAE/2022/028, ASFAE/2022/029, CISEJI/2023/27 and CIDEXG/2023/16; the Department of Education of the Basque Government of Spain under the predoctoral training program non-doctoral research personnel; the Spanish la Caixa Foundation (ID 100010434) under fellowship code LCF/BQ/PI22/11910019; the Portuguese FCT under project UID/FIS/04559/2020 to fund the activities of LIBPhys-UC; the Israel Science Foundation (ISF) under grant 1223/21; the Pazy Foundation (Israel) under grants 310/22, 315/19 and 465; the US Department of Energy under contract numbers DE-AC02-06CH11357 (Argonne National Laboratory), DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M), DE-SC0019054 (Texas Arlington) and DE-SC0019223 (Texas Arlington); the US National Science Foundation under award number NSF CHE 2004111; the Robert A. Welch Foundation under award number Y-2031-20200401. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo de revisión (ReviewArticle)

Measurement of energy resolution with the NEXT-White silicon photomultipliers

  • Contreras, T.
  • Palmeiro, B.
  • Almazán, H.
  • Para, A.
  • Martinez-Lema, G.
  • Guenette, R.
  • Adams, C.
  • Aparicio, B.
  • Aranburu, A. I.
  • Arazi, L.
  • Arnquist, I.J.
  • Auria-Luna, F.
  • Ayet, S.
  • Azevedo, C.D.R.
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] The NEXT-White detector, a high-pressure gaseous xenon time projection chamber, demonstrated the excellence of this technology for future neutrinoless double beta decay searches using photomultiplier tubes (PMTs) to measure energy and silicon photomultipliers (SiPMs) to extract topology information. This analysis uses 83mKr data from the NEXT-White detector to measure and understand the energy resolution that can be obtained with the SiPMs, rather than with PMTs. The energy resolution obtained of (10.9±0.6)%, full-width half-maximum, is slightly larger than predicted based on the photon statistics resulting from very low light detection coverage of the SiPM plane in the NEXT-White detector. The difference in the predicted and measured resolution is attributed to poor corrections, which are expected to be improved with larger statistics. Furthermore, the JHEP09(2024)112 noise of the SiPMs is shown to not be a dominant factor in the energy resolution and may be negligible when noise subtraction is applied appropriately, for high-energy events or larger SiPM coverage detectors. These results, which are extrapolated to estimate the response of large coverage SiPM planes, are promising for the development of future, SiPM-only, readout planes that can offer imaging and achieve similar energy resolution to that previously demonstrated with PMTs., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under Grant Agreement No. 951281-BOLD; the European Union’s Framework Programme for Research and Innovation, Horizon 2020 (2014–2020), under Grant Agreement No. 957202-HIDDEN; Spain’s MCIN/AEI and the ERDF (“A way of making Europe”) under grants PID2021-125475NB and the Severo Ochoa Programme grant CEX2018-000867-S; the Generalitat Valenciana (Spain) under grants PROMETEO/2021/087 and CIDEGENT/2019/049; the Department of Education of the Basque Government (Spain) under the predoctoral training programme for non-doctoral research personnel; the “la Caixa” Foundation (ID 100010434) under fellowship code LCF/BQ/PI22/11910019; the Portuguese Foundation for Science and Technology (FCT) under project UID/FIS/04559/2020 supporting the activities of LIBPhys-UC; the Israel Science Foundation (ISF) under grant 1223/21; the Pazy Foundation (Israel) under grants 310/22, 315/19, and 465; the U.S. Department of Energy under contract numbers DE-AC02-06CH11357 (Argonne National Laboratory), DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M), DE-SC0019054 (The University of Texas at Arlington), and DE-SC0019223 (The University of Texas at Arlington); the U.S. National Science Foundation under award NSF CHE-2004111; and the Robert A. Welch Foundation under award Y-2031-20200401. Finally, we are grateful to the Laboratorio Subterráneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

High voltage delivery and distribution for the NEXT-100 Time Projection Chamber

  • Adams, C.
  • Almazan, H.
  • Bailey, K.
  • Guenette, R.
  • Jones, B. J. P.
  • Johnston, S.
  • Mistry, K.
  • Monrabal, F.
  • Nygren, D. R.
  • Palmeiro, B.
  • Rogers, L.
  • Waldschmidt, J.
  • Aranburu, A. I.
  • Arazi, L.
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • García-Barrena, Jara
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] A critical element in the realization of large liquid and gas time projection chambers (TPCs) is the delivery and distribution of high voltages into and around the detector. Such experiments require of order tens of kilovolts to enable electron drift over meter-scale distances. This paper describes the design and operation of the cathode feedthrough and high voltage distribution through the field cage of the NEXT-100 experiment, an underground TPC that will search for neutrinoless double beta decay 0v beta beta The feedthrough has been demonstrated to hold pressures up to 20 bar and sustain voltages as high as -65 kV. The TPC is operating stably at its design high voltages. The system has been realized within the constraints of a stringent radiopurity budget and is now being used to execute a suite of sensitive double beta decay analyses., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under Grant Agreement No. 951281-BOLD; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under Grant Agreement No. 957202-HIDDEN; the MCIN/AEI of Spain and ERDF A way of making Europe under grants PID2021-125475NB and RTI2018-095979, and the Severo Ochoa and Maria de Maeztu Program grants CEX2023-001292-S, CEX2023-001318-M and CEX2018-000867-S; the Generalitat Valenciana of Spain under grants PROMETEO/2021/087 and CISEJI/2023/27; the Department of Education of the Basque Government of Spain under the predoctoral training program non-doctoral research personnel; the Spanish la Caixa Foundation (ID 100010434) under fellowship code LCF/BQ/PI22/11910019; the Portuguese FCT under project UID/FIS/04559/2020 to fund the activities of LIBPhys-UC; the Israel Science Foundation (ISF) under grant 1223/21; the Pazy Foundation (Israel) under grants 310/22, 315/19 and 465; the US Department of Energy under contracts number DE-AC02-06CH11357 (Argonne National Laboratory), DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M), DE-SC0019054 (Texas Arlington) and DE-SC0019223 and DE-SC0024438 (Texas Arlington); the US National Science Foundation under award number NSF CHE 2004111; the Robert A Welch Foundation under award number Y-2031-20200401. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

The NEXT-100 Detector

  • Adams, C.
  • Almazan, H.
  • Aranburu, A. I.
  • Arazi, L.
  • Arnquist, I. J.
  • Auria-Luna, F.
  • Ayet, S.
  • Ayyad, Y.
  • Azevedo, C. D. R.
  • Bailey, K.
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • García-Barrena, Jara
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • MARTÍNEZ PÉREZ, ALBERTO
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] The NEXT collaboration is dedicated to the study of double beta decays of 136\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$<^>{136}$$\end{document}Xe using a high-pressure gas electroluminescent time projection chamber. This advanced technology combines exceptional energy resolution (<= 1%\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\le 1\%$$\end{document} FWHM at the Q beta beta\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$Q_{\beta \beta }$$\end{document} value of the neutrinoless double beta decay) and powerful topological event discrimination. Building on the achievements of the NEXT-White detector, the NEXT-100 detector started taking data at the Laboratorio Subterr & aacute;neo de Canfranc (LSC) in May of 2024. Designed to operate with xenon gas at 13.5 bar, NEXT-100 consists of a time projection chamber where the energy and the spatial pattern of the ionising particles in the detector are precisely retrieved using two sensor planes (one with photo-multiplier tubes and the other with silicon photo-multipliers). The detector has been operating at stable conditions using argon and xenon gases at similar to\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\sim $$\end{document}4 bar and drift fields of 74Vcm-1\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$74\hbox { V cm}<^>{-1}$$\end{document} and 118Vcm-1\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$118\hbox { V cm}<^>{-1}$$\end{document}, respectively. Alpha decays from the 222\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$<^>{222}$$\end{document}Rn chain have been used to test and monitor the stability of the detector, showing a constant electron lifetime in the drift volume. In this paper, in addition to reporting the results of the commissioning run, we provide a detailed description of the NEXT-100 detector, describe its assembly, and present the current estimation of the radiopurity budget., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under Grant Agreements No. 951281-BOLD and 101039048-GanESS; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under Grant Agreement No. 860881-HIDDeN; the MCIN/AEI of Spain and ERDF A way of making Europe under grants PID2021-125475NB and RTI2018-095979, and the Severo Ochoa and Maria de Maeztu Program grants CEX2023-001292-S, CEX2023-001318-M and CEX2018-000867-S; the Generalitat Valenciana of Spain under grants PROMETEO/2021/087, ASFAE/2022/028, ASFAE/2022/029, CISEJI/2023/27, and CIDEXG/2023/16; the Department of Education of the Basque Government of Spain under the predoctoral training program non-doctoral research personnel; the Spanish la Caixa Foundation (ID 100010434) under fellowship code LCF/BQ/PI22/11910019; the Portuguese FCT under project UID/FIS/04559/2020 to fund the activities of LIBPhys-UC; the Israel Science Foundation (ISF) under grant 1223/21; the Pazy Foundation (Israel) under grants 310/22, 315/19 and 465; the US Department of Energy under contracts number DE-AC02-06CH11357 (Argonne National Laboratory), DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M), DE-SC0019054, DE-SC0019223 and DE-SC0024438 (Texas Arlington); the US National Science Foundation under award number NSF CHE 2004111; the Robert A Welch Foundation under award number Y-2031-20200401. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Demonstration of event position reconstruction based on diffusion in the NEXT-white detector

  • Haefner, J.
  • Navarro, K.E.
  • Guenette, R.
  • Jones, B.J.P.
  • Tripathi, Animesh
  • Adams, C.
  • Almazán, H.
  • Aparicio, B.
  • Aranburu, A. I.
  • Arazi, L.
  • Arnquist, I.J.
  • Auria-Luna, F
  • Ayet, S.
  • Azevedo, C.D.R.
  • Ballester, F.
  • Esteve, R.
  • Mora, F.J.
  • Rodríguez, J.
  • Herrero, V.
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
[EN] Noble element time projection chambers are a leading technology for rare event detection in physics, such as for dark matter and neutrinoless double beta decay searches. Time projection chambers typically assign event position in the drift direction using the relative timing of prompt scintillation and delayed charge collection signals, allowing for reconstruction of an absolute position in the drift direction. In this paper, alternate methods for assigning event drift distance via quantification of electron diffusion in a pure high pressure xenon gas time projection chamber are explored. Data from the NEXT-White detector demonstrate the ability to achieve good position assignment accuracy for both high- and low-energy events. Using point-like energy deposits from Kr-83m calibration electron captures (E similar to 45 keV), the position of origin of low-energy events is determined to 2 cm precision with bias <1 mm. A convolutional neural network approach is then used to quantify diffusion for longer tracks (E >= 1.5 MeV), from radiogenic electrons, yielding a precision of 3 cm on the event barycenter. The precision achieved with these methods indicates the feasibility energy calibrations of better than 1% FWHM at Q(beta beta) in pure xenon, as well as the potential for event fiducialization in large future detectors using an alternate method that does not rely on primary scintillation., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under Grant Agreement No. 951281-BOLD; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under Grant Agreement No. 957202-HIDDEN; the MCIN/AEI of Spain and ERDF A way of making Europe under grants PID2021-125475NB and the Severo Ochoa Program grant CEX2018-000867-S; the Generalitat Valenciana of Spain under grants PROMETEO/2021/087 and CIDEGENT/2019/049; the Department of Education of the Basque Government of Spain under the predoctoral training program non-doctoral research personnel; the Spanish la Caixa Foundation (ID 100010434) under fellowship code LCF/BQ/PI22/11910019; the Portuguese FCT under project UID/FIS/04559/2020 to fund the activities of LIBPhys-UC; the Israel Science Foundation (ISF) under grant 1223/21; the Pazy Foundation (Israel) under grants 310/22, 315/19 and 465; the US Department of Energy under contracts number DE-AC02-06CH11357 (Argonne National Laboratory), DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A &M), DE-SC0019054 (Texas Arlington) and DE-SC0019223 (Texas Arlington); the US National Science Foundation under award number NSF CHE 2004111; the Robert A Welch Foundation under award number Y-2031-20200401.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Measurement of the Xe 136 two-neutrino double -decay half-life via direct background subtraction in NEXT

  • Novella, P.
  • Sorel, M.
  • Usón, A.
  • Adams, C.
  • Almazán, H.
  • Aparicio, B.
  • Aranburu, A. I.
  • Arazi, L.
  • Arnquist, I.J.
  • Ayet, S.
  • Azevedo, D.C.R.
  • Bailey, K.
  • Benlloch-Rodriguez, J. M.
  • Lopez-March, N.
  • Rodríguez, J.
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] We report a measurement of the half-life of the 136Xe two-neutrino double-ß decay performed with a novel direct-background-subtraction technique. The analysis relies on the data collected with the NEXT-White detector operated with 136Xe-enriched and 136Xe-depleted xenon, as well as on the topology of double-electron tracks. With a fiducial mass of only 3.5 kg of Xe, a half-life of 2.34+0.80(stat)+0.30(sys)×1021 yr is derived from ¿0.46 ¿0.17 the background-subtracted energy spectrum. The presented technique demonstrates the feasibility of unique background-model-independent neutrinoless double-ß-decay searches., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under Grant No. 951281-BOLD; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under Grant No. 957202-HIDDEN; the MCIN/AEI/10.13039/501100011033 of Spain and ERDF "A way of making Europe" under Grant No. RTI2018-095979, the Severo Ochoa Program Grant No. CEX2018-000867-S, and the Maria de Maeztu Program Grant No. MDM-2016-0692; the Generalitat Valenciana of Spain under Grants No. PROMETEO/2021/087 and No. CIDEGENT/2019/049; the Portuguese FCT under Project No. UID/FIS/04559/2020 to fund the activities of LIBPhys-UC; the Pazy Foundation (Israel) under Grants No. 877040 and No. 877041; the U.S. Department of Energy under Contracts No. DE-AC02-06CH11357 (Argonne National Laboratory), No. DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), No. DE-FG02-13ER42020 (Texas A&M), No. DE-SC0019054 (Texas Arlington), and No. DE-SC0019223 (Arlington, TX); the U.S. National Science Foundation under Grant No. CHE 2004111; and the Robert A. Welch Foundation under Grant No. Y-203120200401. D.G.D. acknowledges support from the Ramon y Cajal program (Spain) under Contract No. RYC-2015-18820. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.