Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 6
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Design, establishment, analysis, and quality control of a high-precision reference frame in Cortes de Pallás (Spain)

  • García-Asenjo Villamayor, Luis|||0000-0001-6535-2216
  • Baselga Moreno, Sergio|||0000-0002-0492-4003
  • Martínez, Laura
  • Garrigues, Pascual
  • Luján, Raquel
[EN] A high-precision geodetic reference frame was required in Cortes de Pallas (Spain) to undertake a long-term deformation monitoring project. Involving distances up to 2000 m, the aimed accuracy was 1 mm and 3 mm for horizontal and vertical components, respectively. Such a high precision is necessary to detect possible displacements of selected points on a critical rocky area in a short period of time, i.e., 2 or 3 years, and also to provide ground control for the integration of precise 3D models periodically obtained by remote sensing techniques. Considering the historical geotechnical problems of the area, the possible influence of the hydroelectric power plant, and the peculiar orography of the zone, a proper analysis of the stability is crucial if the reference frame is to be used for rigorous over-time deformation monitoring. This paper describes the deformation monitoring of a 10-pillar geodetic network which was measured from 2018 to 2020 by using a sub-millimetric Mekometer ME5000 (0.2 mm + 0.2 ppm) along with a demanding observing methodology which includes a network of data loggers for temperature, humidity, and air pressure as well as proper calibration of sensors and instruments to prevent potential inconsistencies between the scale of the network and the unit of length of the International System (SI meter). The results demonstrated that the chosen methodology yielded the aimed accuracy. However, using such a high precision methodology entails the problem that small displacements of only 1 or 2 mm are significantly detected as deformations by conventional deformation analysis and then it arises the problem of finding a subset of stable points for a rigorous datum realization when all the points seem to displace. This general problem is analyzed in the particular case of Cortes de Pallas, where a balanced mix of deformation analysis and technical decisions was eventually adopted to define a precise and stable reference frame for rigorous over-time deformation monitoring., Open Access funding provided thanks to the CRUE-CSIC agreement with Springer Nature.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Comparison between a Two-Wavelength Absolute Distance Meter and a GNSS-Based Distance Meter at CERN Geodetic Network

  • Guillory, Joffray
  • Wallerand, Jean Pierre
  • Truong, Daniel
  • Luján, Raquel
  • Pesce, Damien
  • Weyer, Benjamin
  • Fuchs, Jean-Frederic
  • Missiaen, Dominique
  • Baselga Moreno, Sergio|||0000-0002-0492-4003
  • García-Asenjo Villamayor, Luis|||0000-0001-6535-2216
[EN] Absolute distance determination, which is the determination of distances consistent with the International System of Units (SI) definition of meter, is a current challenge for distances of several kilometers in the open air and with submillimetric accuracies, which is being increasingly demanded for scientific and technological applications. We present the first comparison of two techniques recently developed for this purpose: the Arpent Absolute Distance Meter and the improved Global Navigation Satellite System (GNSS)-based distance meter. Both techniques have been tested and compared on the European Organization for Nuclear Research (CERN) geodetic network during a 2-week observation campaign. The results obtained include the rigorous determination of the uncertainties for both methodologies. In the end, four baselines of 2.2, 4.8, 6.0, and 6.5 km were measured, and for three of them, the differences between the two systems were less than 0.7 mm. The baseline of 4.8 km showed a difference of 2.7 mm, i.e., about 0.6 parts per million (ppm): in the case of conventional optical telemetry, such an agreement would require refractivity correction with knowledge of the air temperature and pressure at better than 0.6 K and 0.15 hPa, respectively., This work was partially funded by the Joint Research Project (JRP) 18SIB01 GeoMetre. This project has received funding from the European Metrology Programme for Innovation and Research (EMPIR, funder ID 10.13039/100014132), cofinanced by the participating states and from the European Union's Horizon 2020 research and innovation program. This work was partially funded by the project Development of High-Precision GNSS Techniques for Dimensional Metrology, Deformation Monitoring, and Geodetic Networks for Civil Engineering Projects (GNSS-Metrology), ref. PID2022-142363NB-I00, Plan Estatal de Investigacion Cientifica y Tecnica y de Innovacion 2021-2023, MCIN/AEI/10.13039/501100011033/FEDER, UE.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

EDM-GNSS distance comparison at the EURO5000 calibration baseline: preliminary results

  • Wezka, Kinga
  • Próchniewicz, Dominik
  • Szpunar, Ryszard
  • Garrigues Talens, Pascual
  • Walo, Janusz
  • Luján, Raquel
  • García-Asenjo Villamayor, Luis|||0000-0001-6535-2216
  • Baselga Moreno, Sergio|||0000-0002-0492-4003
[EN] At the Pieniny Klippen Belt in Poland, the novel primary reference baseline EURO5000 is required as part of the European Research project GeoMetre to both validate refractivity-compensated EDM prototypes and investigate the metrological traceability of GNSS-based distances. Since the aimed uncertainty is 1 mm at 5 km (k = 2), the design, construction, and validation must be carefully prepared to fulfil the high standards of the GeoMetre field campaigns which are planned to be carried out in May 2022. This contribution describes the main features of the EURO5000 and presents the results of the preliminary validation which includes a first comparison between the results obtained by using precise currently available EDMs as well as GNSS techniques following the standard GNSS geodetic processing algorithms, on the one hand, and the improved GNSS-Based Distance Meter (GBDM+) approach developed at UPV, on the other hand. The preliminary validation presented in this contribution also permits (1) to detect potential problems in the use of the baseline such as potential geodynamic problems, atmospheric refraction or multipath limitations, (2) to produce a set of reliable results, and (3) to pave the way for the final field comparisons between the novel EDMs and the GBDM+ approach. The result of this metrological experiment may significantly contribute to overcome the limitations of current high-precision deformation monitoring applications that require their scale to be consistent with the SI-metre within 0.1 ppm in several km., The project 18SIB01 GeoMetre hasreceived funding from the EMPIR programme co-financedby the Participating States and from the European Union's Horizon 2020 research and innovation programme, funderID: 10.13039/100014132. Raquel Lujan acknowledges the funding from the Programa de Ayudas de Investigaciony Desarrollo (PAID-01-20) de la Universitat Politecnica deValencia.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Development of a Submillimetric GNSS-Based Distance Meter for Length Metrology

  • García-Asenjo Villamayor, Luis|||0000-0001-6535-2216
  • Baselga Moreno, Sergio|||0000-0002-0492-4003
  • Atkins, Chris
  • Garrigues Talens, Pascual
[EN] Absolute distance determination in the open air with an uncertainty of a few tenths of a millimetre is increasingly required in many applications that involve high precision geodetic metrology. No matter the technique used to measure, the resulting distances must be proven consistent with the unit of length (SI-metre) as realized in the outdoor facilities traditionally used in length metrology, which are also known as calibration baselines of reference. The current calibration baselines of reference have distances in the range of 10 to 1000 m, but at present there is no solution on the market to provide distances with submillimetric precision in that range. Consequently, new techniques such as multi-wave interferometry, two-wave laser telemeters or laser trackers are being developed. A possible alternative to those sophisticated and expensive techniques is the use of widely used Global Navigation Satellite Systems (GNSS) in order to provide a GNSS-Based Distance Meter (GBDM). The use of a GBDM as a potential technique for length metrology has been thoroughly analysed in several European research projects by using the state-of-the-art geodetic software, such as Bernese 5.2, but no definite conclusions have been drawn and some metrological questions are considered still open. In this paper, we describe a dedicated approach to build up a submillimetric GBDM able to be applied in the current calibration baselines of reference, as well as possible methods to cope with the multipath error of the GNSS signals which is the major limitation for the practical uptaking of the technique in metrology. The accuracy of the proposed approach has been tested following the length metrology standards in four experiments carried out in the Universitat Politecnica de Valencia (UPV). The results demonstrate that the proposed GBDM can provide an accuracy of a few tenths of a millimetre in the current calibration baselines of reference, This work was partly performed within the 18SIB01 GeoMetre project of the European Metrology Programme for Innovation and Research (EMPIR). This project has received funding from the EMPIR programme co-financed by the Participating States and from the European Union's Horizon 2020 research and innovation programme. This research was also partly funded by the Spanish Ministry of Education, Culture and Sports (PRX17/00371).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

The European GeoMetre project: developing enhanced large-scale dimensional metrology for geodesy

  • Pollinger, Florian
  • Courde, Clément
  • Eschelbach, Cornelia
  • Garrigues, Pascual
  • Guillory, Joffray
  • Hedekvist, Per Olof
  • Helojärvi, Tuomas
  • Jokela, Jorma
  • Kallio, Ulla
  • Klügel, Thomas
  • Köchert, Paul
  • Lösler, Michael
  • Luján, Raquel
  • Meyer, Tobias
  • Neyezhmakov, Pavel
  • Pesce, Damien
  • Pisani, Marco
  • Poutanen, Markku
  • Prellinger, Günther
  • Sauthoff, Anni
  • Seppä, Jeremias
  • Truong, Daniel
  • Underwood, Robin
  • Wezka, Kinga
  • Wallerand, Jean Pierre
  • Wisniewski, Mariusz
  • Baselga Moreno, Sergio|||0000-0002-0492-4003
  • García-Asenjo Villamayor, Luis|||0000-0001-6535-2216
[EN] We provide a survey on the joint European research project "GeoMetre", which explores novel technologies and their inclusion to existing surveying strategies to improve the traceability of geodetic reference frames to the SI definition of the metre. This work includes the development of novel distance meters with a range of up to 5 km, the realisation of optical multilateration systems for large structure monitoring at an operation distance of 50 m and beyond, and a novel strategy for GNSS-based distance determination. Different methods for refractivity compensation, based on classical sensors, on dispersion, on spectroscopic thermometry, and on the speed of sound to reduce the meteorological uncertainties in precise distance measurements, are developed further and characterised. These systems are validated at and applied to the novel European standard baseline EURO5000 at the Pieniny Kippen Belt, Poland, which was completely refurbished and intensely studied in this project. We use our novel instruments for a reduced uncertainty of the scale in the surveillance networks solutions for local tie measurements at space-geodetic co-location stations. We also investigate novel approaches like close-range photogrammetry to reference point determination of space-geodetic telescopes. Finally, we also investigate the inclusion of the local gravity field to consider the deviations of the vertical in the data analysis and to reduce the uncertainty of coordinate transformations in this complex problem., Open Access funding enabled and organized by Projekt DEAL. This project 18SIB01 GeoMetre has received funding from the EMPIR programme co-financed by the Participating States and from the European Union's Horizon 2020 research and innovation programme.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

GBDM+: an improved methodology for a GNSS-based distance meter

  • Baselga Moreno, Sergio|||0000-0002-0492-4003
  • García-Asenjo Villamayor, Luis|||0000-0001-6535-2216
  • Garrigues Talens, Pascual
  • Luján, Raquel
[EN] The determination of distances consistent with the definition of the base unit of length in the International System of Units (SI), the SI meter, with uncertainties of less than 1 ppm up to 5 km in the open air is a current challenge that is being increasingly required for different applications, including the determination of local ties, calibration baselines, and high precision geodetic metrology in singular scientific and engineering projects. The required knowledge of the index of refraction of the propagating medium at the same level of 1 ppm is a hard limit to the use of precise electronic distance meters (EDMs), which has motivated the recent development of new two-color, refractivity compensated, EDM prototypes. As an alternative, the use of global navigation satellite systems (GNSS) could benefit from their high scale stability although the lack of appropriate estimation of the uncertainties in their sources of error and their unknown propagation into the final result during the data processing has prevented a rigorous uncertainty analysis and, therefore, the use of GNSS for absolute distance determination. Stemming from our initial methodology for a GNSS-based distance meter (GBDM) that was restricted to relatively horizontal baselines and distances up to 1 km only, we have improved the method so that its application range is extended to baselines of up to 5 km with a possibly significant height difference so that it provides the final baseline distance with the corresponding uncertainty derived from the uncertainties in the different error sources rigorously propagated through the equations by which the distance is finally determined. This improved methodology, named as GBDM+, constitutes a significant step forward in the application of GNSS to open air length metrology., The work leading to this paper was performed within the 18SIB01 GeoMetre project of the European Metrology Programme for Innovation and Research (EMPIR). This project has received funding from the EMPIR programme co-financed by the Participating States and from the European Union's Horizon 2020 research and innovation programme, funder ID: 10.13039/100014132. Raquel Lujan acknowledges the funding from the Programa de Ayudas de Investigacion y Desarrollo (PAID-01-20) de la Universitat Politecnica de Valencia.