Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Comparative Analysis of Data Acquisition Setups for Fast Timing in ToF-PET Applications

  • Latella, Riccardo|||0000-0002-5044-9557
  • Benlloch Baviera, Jose María|||0000-0001-6073-1436
  • Lecoq, Paul
  • Gonzalez, Antonio J.
  • Konstantinou, Georgios
[EN] The signal-to-noise ratio in positron emission tomography (PET) improves with precise timing resolution. PET systems enabling the capability of time-of-flight (ToF) are nowadays available. This study assesses various data configurations, comparing the obtained timing performances applicable to time-of-flight positron emission tomography (ToF-PET) systems. Different readout configurations were evaluated together with silicon photomultipliers (SiPMs) photosensors from the Fondazione Bruno Kessler (FBK), with and without the so-called metal trench (MT) technology. The tests were carried out with scintillation crystals of 3x3x5 mm(3) (LYSO:Ce,Ca) from SIPAT. Two onboard FPGA-based systems, namely, the Felix time-to-digital converter (TDC) from Tediel S.r.l. and the ASIC-based FastIC from the University of Barcelona, along with custom-made high-frequency electronics (CM-HF), were compared. Considering only photopeak events, the best-coincidence timing resolution (CTR) results obtained were 71 ps with the MT SiPMs. This result worsened to 88 ps with the old version of the same device that does not include the MT technology (called HD). The results demonstrate substantial CTR improvements when MT SiPMs were used across the different scenarios, resulting in a timing improvement in the 10 to 45-ps range compared to HD SiPMs. Notably, the Felix TDC achieved sub-100-ps timing results, emphasizing the potential of FPGA technology in ToF-PET applications. Moreover, the fully passive version of the CM-HF connected to the MT SiPMs shows only a degradation of 8-ps difference compared to the version using amplifiers. The novel MT-type SiPMs promise superior timing performance, enhancing accuracy and efficiency in PET imaging systems., This work was supported in part by the frame of the ERC Advanced Grant TICAL under Grant 338953 PI (P. Lecoq), and the related Prof-of-Concept Project ULTIMA under Grant 680552, both funded by the European Commission; and in part by the European Research Council (ERC) through the European Union's Horizon 2020 Research and Innovation Program under Grant 695536.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Exploiting Cherenkov Radiation With BGO-Based Metascintillators

  • Latella, Riccardo|||0000-0002-5044-9557
  • González Martínez, Antonio Javier
  • Kovylina-Zabyako, Miroslavna
  • Griol Barres, Amadeu
  • Benlloch Baviera, Jose María|||0000-0001-6073-1436
  • Lecoq, Paul
  • Bonifacio, Daniel A. B.
  • Konstantinou, Georgios
[EN] In time-of-flight positron emission tomography (TOF-PET), the timing capabilities of the scintillation-based detector play an important role. An approach for fast timing is using the so-called metascintillators, which combine two materials leading to the synergistic blending of their favorable characteristics. An added effect for BGO-based metascintillators is taking advantage of better transportation of Cherenkov photons through UV-transparent materials such as plastic (type EJ232). To prove this, we use an optimized Coincidence Time Resolution (CTR) setup based on electronic boards with two output signals (timing and energy) and near-ultraviolet (NUV) and vacuum-ultraviolet (VUV) silicon photomultipliers (SiPMs) from Fondazione Bruno Kessler (FBK), along with different coupling materials. As a reference detector, we employed a 3x3x5-mm(3) LYSO:Ce,Ca crystal pixel coupled with optical grease to an NUV-HD SiPM. The evaluation is based on low-threshold rise time, energy and time of arrival of event datasets. Timing results of a BGO/EJ232 3x3x15-mm(3) metapixel show detector time resolutions (DTRs) of 159 ps for the full photopeak. We demonstrate the possibility of event discrimination using subsets with different DTR from the rise time distributions (RTDs). Finally, we present the synergistic capability of metascintillators to enhance Cherenkov photons detection when used along with VUV-sensitive SiPMs., This work was supported in part by the European Research Council (ERC) under the European Union's Horizon 2020 Research and Innovation Program (4D-PET) under Grant 695536, and in part by the Brazilian Funding Agency Conselho Nacional de Desenvolvimento Cientifico e Tecnologico (CNPq) under Grant 202378/2020-9.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Metascintillators: New Results for TOF-PET Applications

  • Lecoq, Paul
  • Latella, Riccardo|||0000-0002-5044-9557
  • Moliner Martínez, Laura
  • Barrio-Toala, John|||0000-0001-5181-2146
  • Benlloch Baviera, Jose María|||0000-0001-6073-1436
  • González Martínez, Antonio Javier
  • Konstantinou, Georgios
  • Nuyts, Johan
  • Zhang, Lei
[EN] We report on the progress on a first generation of realistic size metascintillators for time-of-flight PET. These heterostructures combine dense LYSO or BGO plates, interleaved with fast scintillator layers producing a bunch of prompt photons from the energy leakage of the recoil photoelectric electron. From a Geant4 simulation of the energy sharing distribution between the dense and the fast scintillator on 42 LYSO-based and 42 BGO-based configurations, a detailed study of the timing performance has been performed on a selection of the most promising 12 LYSO-based and 14 BGO-based metascintillators. A Monte Carlo simulation was first performed to extrapolate from direct measurements of the performance of the metascintillator components, the detector time resolution (DTR), and sensitivity on the basis of the simulated amount of energy leakage to the fast scintillator. An analytic algorithm was then applied to determine an equivalent coincidence time resolution (CTR) from the random association of the DTR distributions from two metapixels in coincidence. This equivalent CTR is calculated in order to obtain the same variance in the reconstructed image as the combination of the DTR distributions of 2 metapixels. Preliminary results confirm that with these simple and still nonoptimized configurations, an equivalent CTR of 150 ps for BGO-based and 140 ps for LYSO-based metapixels of realistic size can be obtained, This work was supported in part by the European Research Council (ERC) through the European Union's Horizon 2020 Research and Innovation Programme under Grant 695536. The work of P. Lecoq was supported in part by ERC Advanced under Grant TICAL 338953, and in part by the related Proof-of-Concept Project under Grant ULTIMA 680552, both funded by the European Commission.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Metascintillators: New Results for TOF-PET Applications

  • Lecoq, P.
  • Konstantinou, Georgios
  • Latella, Riccardo
  • Moliner, Laura
  • Nuyts, Johan
  • Zhang, Lei
  • Barrio Toala, J.
  • Benlloch Baviera, José María
  • González Martínez, Antonio Javier
We report on the progress on a first generation of realistic size metascintillators for time-of-flight PET. These heterostructures combine dense LYSO or BGO plates, interleaved with fast scintillator layers producing a bunch of prompt photons from the energy leakage of the recoil photoelectric electron. From a Geant4 simulation of the energy sharing distribution between the dense and the fast scintillator on 42 LYSO-based and 42 BGO-based configurations, a detailed study of the timing performance has been performed on a selection of the most promising 12 LYSO-based and 14 BGO-based metascintillators. A Monte Carlo simulation was first performed to extrapolate from direct measurements of the performance of the metascintillator components, the detector time resolution (DTR), and sensitivity on the basis of the simulated amount of energy leakage to the fast scintillator. An analytic algorithm was then applied to determine an equivalent coincidence time resolution (CTR) from the random association of the DTR distributions from two metapixels in coincidence. This equivalent CTR is calculated in order to obtain the same variance in the reconstructed image as the combination of the DTR distributions of 2 metapixels. Preliminary results confirm that with these simple and still nonoptimized configurations, an equivalent CTR of 150 ps for BGO-based and 140 ps for LYSO-based metapixels of realistic size can be obtained., This work was supported in part by the European Research Council (ERC) through the European Union’s Horizon 2020 Research and Innovation Programme under Grant 695536. The work of P. Lecoq was supported in part by ERC Advanced under Grant TICAL 338953, and in part by the related Proof-ofConcept Project under Grant ULTIMA 680552, both funded by the European Commission. (Corresponding author: P. Lecoq.), Peer reviewed