Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 7
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Comparative Analysis of Data Acquisition Setups for Fast Timing in ToF-PET Applications

  • Latella, Riccardo|||0000-0002-5044-9557
  • Benlloch Baviera, Jose María|||0000-0001-6073-1436
  • Lecoq, Paul
  • Gonzalez, Antonio J.
  • Konstantinou, Georgios
[EN] The signal-to-noise ratio in positron emission tomography (PET) improves with precise timing resolution. PET systems enabling the capability of time-of-flight (ToF) are nowadays available. This study assesses various data configurations, comparing the obtained timing performances applicable to time-of-flight positron emission tomography (ToF-PET) systems. Different readout configurations were evaluated together with silicon photomultipliers (SiPMs) photosensors from the Fondazione Bruno Kessler (FBK), with and without the so-called metal trench (MT) technology. The tests were carried out with scintillation crystals of 3x3x5 mm(3) (LYSO:Ce,Ca) from SIPAT. Two onboard FPGA-based systems, namely, the Felix time-to-digital converter (TDC) from Tediel S.r.l. and the ASIC-based FastIC from the University of Barcelona, along with custom-made high-frequency electronics (CM-HF), were compared. Considering only photopeak events, the best-coincidence timing resolution (CTR) results obtained were 71 ps with the MT SiPMs. This result worsened to 88 ps with the old version of the same device that does not include the MT technology (called HD). The results demonstrate substantial CTR improvements when MT SiPMs were used across the different scenarios, resulting in a timing improvement in the 10 to 45-ps range compared to HD SiPMs. Notably, the Felix TDC achieved sub-100-ps timing results, emphasizing the potential of FPGA technology in ToF-PET applications. Moreover, the fully passive version of the CM-HF connected to the MT SiPMs shows only a degradation of 8-ps difference compared to the version using amplifiers. The novel MT-type SiPMs promise superior timing performance, enhancing accuracy and efficiency in PET imaging systems., This work was supported in part by the frame of the ERC Advanced Grant TICAL under Grant 338953 PI (P. Lecoq), and the related Prof-of-Concept Project ULTIMA under Grant 680552, both funded by the European Commission; and in part by the European Research Council (ERC) through the European Union's Horizon 2020 Research and Innovation Program under Grant 695536.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Exploiting Cherenkov Radiation With BGO-Based Metascintillators

  • Latella, Riccardo|||0000-0002-5044-9557
  • González Martínez, Antonio Javier
  • Kovylina-Zabyako, Miroslavna
  • Griol Barres, Amadeu
  • Benlloch Baviera, Jose María|||0000-0001-6073-1436
  • Lecoq, Paul
  • Bonifacio, Daniel A. B.
  • Konstantinou, Georgios
[EN] In time-of-flight positron emission tomography (TOF-PET), the timing capabilities of the scintillation-based detector play an important role. An approach for fast timing is using the so-called metascintillators, which combine two materials leading to the synergistic blending of their favorable characteristics. An added effect for BGO-based metascintillators is taking advantage of better transportation of Cherenkov photons through UV-transparent materials such as plastic (type EJ232). To prove this, we use an optimized Coincidence Time Resolution (CTR) setup based on electronic boards with two output signals (timing and energy) and near-ultraviolet (NUV) and vacuum-ultraviolet (VUV) silicon photomultipliers (SiPMs) from Fondazione Bruno Kessler (FBK), along with different coupling materials. As a reference detector, we employed a 3x3x5-mm(3) LYSO:Ce,Ca crystal pixel coupled with optical grease to an NUV-HD SiPM. The evaluation is based on low-threshold rise time, energy and time of arrival of event datasets. Timing results of a BGO/EJ232 3x3x15-mm(3) metapixel show detector time resolutions (DTRs) of 159 ps for the full photopeak. We demonstrate the possibility of event discrimination using subsets with different DTR from the rise time distributions (RTDs). Finally, we present the synergistic capability of metascintillators to enhance Cherenkov photons detection when used along with VUV-sensitive SiPMs., This work was supported in part by the European Research Council (ERC) under the European Union's Horizon 2020 Research and Innovation Program (4D-PET) under Grant 695536, and in part by the Brazilian Funding Agency Conselho Nacional de Desenvolvimento Cientifico e Tecnologico (CNPq) under Grant 202378/2020-9.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Metascintillators: New Results for TOF-PET Applications

  • Lecoq, Paul
  • Latella, Riccardo|||0000-0002-5044-9557
  • Moliner Martínez, Laura
  • Barrio-Toala, John|||0000-0001-5181-2146
  • Benlloch Baviera, Jose María|||0000-0001-6073-1436
  • González Martínez, Antonio Javier
  • Konstantinou, Georgios
  • Nuyts, Johan
  • Zhang, Lei
[EN] We report on the progress on a first generation of realistic size metascintillators for time-of-flight PET. These heterostructures combine dense LYSO or BGO plates, interleaved with fast scintillator layers producing a bunch of prompt photons from the energy leakage of the recoil photoelectric electron. From a Geant4 simulation of the energy sharing distribution between the dense and the fast scintillator on 42 LYSO-based and 42 BGO-based configurations, a detailed study of the timing performance has been performed on a selection of the most promising 12 LYSO-based and 14 BGO-based metascintillators. A Monte Carlo simulation was first performed to extrapolate from direct measurements of the performance of the metascintillator components, the detector time resolution (DTR), and sensitivity on the basis of the simulated amount of energy leakage to the fast scintillator. An analytic algorithm was then applied to determine an equivalent coincidence time resolution (CTR) from the random association of the DTR distributions from two metapixels in coincidence. This equivalent CTR is calculated in order to obtain the same variance in the reconstructed image as the combination of the DTR distributions of 2 metapixels. Preliminary results confirm that with these simple and still nonoptimized configurations, an equivalent CTR of 150 ps for BGO-based and 140 ps for LYSO-based metapixels of realistic size can be obtained, This work was supported in part by the European Research Council (ERC) through the European Union's Horizon 2020 Research and Innovation Programme under Grant 695536. The work of P. Lecoq was supported in part by ERC Advanced under Grant TICAL 338953, and in part by the related Proof-of-Concept Project under Grant ULTIMA 680552, both funded by the European Commission.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

A proof-of-concept of cross-luminescent metascintillators: testing results on a BGO: BaF2metapixel

  • Konstantinou, G.
  • Zhang, L.
  • Latella, Riccardo|||0000-0002-5044-9557
  • Moliner Martínez, Laura
  • Benlloch Baviera, Jose María|||0000-0001-6073-1436
  • González Martínez, Antonio Javier
  • Lecoq, Paul
[EN] Objective: Time-of-flight positron emission tomography (PET)is the next frontier in improving the effective sensitivity. To achieve superior timing for time-of-flight PET, combined with high detection efficiency and cost-effectiveness, we have studied the applicability of BaF2 in metascintillators driven by the timing of cross-luminescence photon production. Approach: Based on previous simulation studies of energy sharing and analytic multi-exponential scintillation pulse, as well as sensitivity characteristics, we have experimentally tested a pixel of 3 × 3 × 15 mm3 based on 300 ¿m BGO and 300 ¿m BaF2 layers. To harness the deep ultraviolet cross-luminescent light component, which carries improved timing, we use the FBK VUV SiPM. Metascintillator energy sharing is addressed through a double integration approach. Main results: We reach an energy resolution of 22%, comparable to an 18% resolution of simple BGO pixels using the same readout, through the optimized use of the integrals of the metascintillator pulse in energy sharing calculation. We measure the energy sharing extent of each pulse with a resolution of 25% and demonstrate that experimental and simulation results agree well. Based on the energy sharing, a timewalk correction is applied, exhibiting significant improvements for both the coincidence time resolution (CTR) and the shape of the timing histogram. We reach 242 ps CTR for the entire photopeak, while for a subset of 13% of the most shared events, the CTR value improves to 108 ps, comparable to the 3 × 3 × 5 mm3 LYSO:Ce:Ca reference crystal. Significance: While we are considering different ways to improve further these results, this proof-ofconcept demonstrates the applicability of cross-luminescence for metascintillator designs through the application of VUV compatible SiPM coupling, and easily implementable digital algorithms. This is the first test of BaF2-based metascintillators of sufficient stoppng power to be included in a PET scanner, demonstrating the industrial applicability of such cross-luminescent metascintillators., Part of the research presented in this manuscript was funded by the ERC grant Innovative PET scanner for dynamic imaging, agreement no 695536. The concept presented in this manuscript was based on research first developed within the TICAL: 4D total absorptionTime Imaging CALorimeter ERC grant, agreement no 338953. The authors would like to acknowledge the support of Dr. Daniel Bonifacio of IPEN, Sao Paolo, Brazil.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Semi-Monolithic Meta-Scintillator Simulation Proof-of-Concept, Combining Accurate DOI and TOF

  • Konstantinou, Georgios
  • Zhang, Lei
  • Bonifacio, Daniel
  • Latella, Riccardo|||0000-0002-5044-9557
  • Benlloch Baviera, Jose María|||0000-0001-6073-1436
  • González Martínez, Antonio Javier
  • Lecoq, Paul
[EN] In this study, we propose and examine a unique semimonolithic metascintillator (SMMS) detector design, where slow scintillators (BGO or LYSO) are split into thin slabs and read by an array of SiPM, offering depth-of-interaction (DOI) information. These are alternated with thin segmented fast scintillators (plastic EJ232 or EJ232Q), also read by single SiPMs, which provides pixel-level coincidence time resolution (CTR). The structure combines layers of slow scintillators of size 0.3 x 25.5 x (15 or 24) mm(3) with fast scintillators of size 0.1 x 3.1 x (15 or 24) mm(3). We use a Monte Carlo Gate simulation to gauge this novel semimonolithic detector's performance. We found that the time resolution of SMMS is comparable to pixelated metascintillator designs with the same materials. For example, a 15-mm deep LYSO-based SMMS yielded a CTR of 121 ps before applying timewalk correction (after correction, 107-ps CTR). The equivalent BGO-based SMMS presented a CTR of 241 ps, which is a 15% divergence from metascintillator pixel experimental findings from previous works. We also applied neural networks to the photon distributions and timestamps recorded at the SiPM array, following guidelines on semimonolithic detectors. This led to determining the DOI with less than 3-mm precision and a confidence level of 0.85 in the best case, plus more than 2 standard deviations accuracy in reconstructing energy sharing and interaction energy. In summary, neural network prediction capabilities outperform standard energy calculation methods or any analytical approach on energy sharing, thanks to the improved understanding of photon distribution., This work was supported in part by the European Research Council in the framework of the ERC Advanced Grant TICAL under Grant 338953, and in part by the European Research Council (ERC) through the European Union s Horizon 2020 Research and Innovation Program (4DPET) under Grant 695536.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Toward a Second Generation of Metascintillators Using the Purcell Effect

  • Shultzman, Avner
  • Schutz, Roman
  • Kurman, Yaniv
  • Lahav, Neta
  • Dosovitskiy, George
  • Roques-Carmes, Charles
  • Bekenstein, Yehonadav
  • Konstantinou, Georgios
  • Latella, Riccardo
  • Zhang, Lei
  • Loignon-Houle, Francis
  • González Martínez, Antonio Javier
  • Benlloch Baviera, José María
  • Kaminer, Ido
  • Lecoq, Paul
This study focuses on advancing metascintillators to break the 100 ps barrier and approach the 10 ps target. We exploitnanophotonic features, specifically the Purcell effect, to shape and enhance the scintillation properties of the first-generation metascintillator. We demonstrate that a faster emission is achievable along with a more efficient conversionefficiency. This results in a coincidence time resolution improved by a factor of 1.3, crucial for TOF-PET applications., The metascintillator concept presented in this manuscript was based on research first developed within the ERC Adv Project TICAL: 4-D total absorption time imaging CALorimeter, P. Lecoq (Grant Agreement No. 338953). The authors also acknowledge the Pazy Foundation and Technion’s Helen Diller Quantum Center for their support in developing the nanophotonic concepts., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Metascintillators: New Results for TOF-PET Applications

  • Lecoq, P.
  • Konstantinou, Georgios
  • Latella, Riccardo
  • Moliner, Laura
  • Nuyts, Johan
  • Zhang, Lei
  • Barrio Toala, J.
  • Benlloch Baviera, José María
  • González Martínez, Antonio Javier
We report on the progress on a first generation of realistic size metascintillators for time-of-flight PET. These heterostructures combine dense LYSO or BGO plates, interleaved with fast scintillator layers producing a bunch of prompt photons from the energy leakage of the recoil photoelectric electron. From a Geant4 simulation of the energy sharing distribution between the dense and the fast scintillator on 42 LYSO-based and 42 BGO-based configurations, a detailed study of the timing performance has been performed on a selection of the most promising 12 LYSO-based and 14 BGO-based metascintillators. A Monte Carlo simulation was first performed to extrapolate from direct measurements of the performance of the metascintillator components, the detector time resolution (DTR), and sensitivity on the basis of the simulated amount of energy leakage to the fast scintillator. An analytic algorithm was then applied to determine an equivalent coincidence time resolution (CTR) from the random association of the DTR distributions from two metapixels in coincidence. This equivalent CTR is calculated in order to obtain the same variance in the reconstructed image as the combination of the DTR distributions of 2 metapixels. Preliminary results confirm that with these simple and still nonoptimized configurations, an equivalent CTR of 150 ps for BGO-based and 140 ps for LYSO-based metapixels of realistic size can be obtained., This work was supported in part by the European Research Council (ERC) through the European Union’s Horizon 2020 Research and Innovation Programme under Grant 695536. The work of P. Lecoq was supported in part by ERC Advanced under Grant TICAL 338953, and in part by the related Proof-ofConcept Project under Grant ULTIMA 680552, both funded by the European Commission. (Corresponding author: P. Lecoq.), Peer reviewed