Pasar al contenido principal

MYGAIT_BIO. PLANTILLAS INTELIGENTES PARA LA REALIZACION DE MEDIDAS CARDIOVASCULARES

PID2020-116011RB-C21

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2020
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSITAT POLITECNICA DE CATALUNYA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 9
Encontrada(s) 1 página(s)

UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Robust algorithm for the detection and classification of QRS complexes with different morphologies using the continuous spline wavelet transform with automatic scale detection

  • Martínez Suárez, Frank
  • Alvarado Serrano, Carlos
  • Casas Piedrafita, Óscar|||0000-0002-0077-0561
This work presents an algorithm for the detection and classification of QRS complexes based on the continuous wavelet transform (CWT) with splines. This approach can evaluate the CWT at any integer scale and the analysis is not restricted to powers of two. The QRS detector comprises four stages: implementation of CWT with splines, detection of QRS complexes, searching for undetected QRS complexes, and correction of the R wave peak location in detected QRS complexes. After, the onsets and ends of the QRS complexes are detected. The algorithm was evaluated with synthetic ECG and with the manually annotated databases: MIT-BIH Arrhythmia, European ST-T, QT and PTB Diagnostic ECG. Evaluation results of the QRS detector were: MIT-BIH arrhythmia database (109,447 beats analyzed), sensitivity Se = 99.72% and positive predictivity P+ = 99.87%; European ST-T database (790522 beats analyzed), Se = 99.92% and P+ = 99.55% and QT database (86498 beats analyzed), Se = 99.97% and P+ = 99.99%. To evaluate the delineation algorithm of the QRS onset (Qi) and QRS end (J) with the QT and PTB Diagnostic ECG databases, the mean and standard deviations of the differences between the automatic and manual annotated location of these points were calculated. The standard deviations were close to the accepted tolerances for deviations determined by the CSE experts. The proposed algorithm is robust to noise, artifacts and baseline drifts, classifies QRS complexes, automatically selects the CWT scale according to the sampling frequency of the ECG record used, and adapts to changes in the heart rate, amplitude and morphology of QRS complexes., This work has been funded by a scholarship from the CONAHCYT (México) to Frank Martínez-Suárez (No. CVU = 736915) and The Spanish Agencia Estatal de Investigación under grant PID2020-116011RBC21 (MCIN / AEI / 10.13039/501100011033)., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Compact, fully differential analog amplitude demodulator by power supply voltage switching

  • Serrano Finetti, Roberto Ernesto|||0000-0002-5628-5426
  • Hornero Ocaña, Gemma|||0000-0002-2998-3173
  • Casas Piedrafita, Óscar|||0000-0002-0077-0561
There is a growing interest in developing impedance sensors able to work at low power and with a small footprint. The analog lock-in amplifier (an amplitude-modulated (AM) demodulator) is a common solution to recover the baseband signal from modulating sensors while avoiding low-frequency noise. However, it uses several active components whose total power consumption might shorten battery life. In this work, we propose a simple AM demodulator based on a fully differential switched-gain amplifier. Using op amps with shutdown enables the gain switching between 0 and 1, which recovers the baseband signal in a similar way to a conventional +1/-1 switched gain amplifier, but with a 50% amplitude decrease in the demodulated signal. By using a power-down signal synchronized with the carrier, it is possible to program a 0° or 90° phase that enables in-phase and quadrature demodulation, ultimately allowing the measurement of complex impedances. Tests were performed in two different situations: static and time-varying impedances, and with two different op amp models, the OPA363 and the ADA4806-1. In the former test, several resistors and capacitors were measured, yielding deviations from a reference instrument below 0.5% for resistors and below 2.7% for capacitors when using the OPA363. In the latter test, the electrical bioimpedance changes of the hand-to-hand body segment of a number of healthy volunteers were recorded, enabling the detection of the respiratory and pulse rate., This work was supported by the Spanish Agencia Estatal de Investigación under Grant PID2020-116011RB-C21 (MCIN/AEI/10.13039/501100011033)., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Low-power wireless system for continuous measurement of cardiovascular parameters on a single limb

  • Gascón Roche, Alberto
  • Serrano Finetti, Roberto Ernesto|||0000-0002-5628-5426
  • Marco Marco, Álvaro
  • Casanella Alonso, Ramón|||0000-0003-2995-7132
  • López Lapeña, Oscar|||0000-0002-6024-0722
  • Hornero Ocaña, Gemma|||0000-0002-2998-3173
  • Casas Nebra, Roberto
  • Casas Piedrafita, Óscar|||0000-0002-0077-0561
A novel low-power sensor wireless system for continuous and simultaneous measurement of the electrocardiogram (ECG) and the impedance plethysmogram (IPG) from a single limb has been designed and tested. This system is made up of an analog subsystem composed of two signal-conditioning channels, one for the ECG and one for the IPG that share the same voltage pickup electrodes, and a digital subsystem based on the BGM220PC22WGA microcontroller that is responsible for digitizing the signals and sending their data via Bluetooth Low Energy (BLE) to a processing unit. The consumption of the system has been analyzed using different settings, obtaining values that would allow a battery duration of up to 131 h, by performing four 30-s measurements every hour. The system was tested in one arm and one leg in a group of healthy volunteers to verify the functionality and to identify the best electrode positions to get high quality signals. Non-standard ECG leads are obtained in both one arm and one leg with an SNR of more than 30 dB. In the worst case, for measurements on the legs, the mean error of the RR intervals from each recording was 1.7 ms and the 95% confidence interval (±SD) was ±7.3 ms versus a reference system. This has made it possible to accurately obtain the Pulse Arrival Time (PAT) between the ECG and the simultaneously measured IPG signal, which allows more cardiovascular information to be obtained from the patient than with systems that acquire only the ECG signal., This work was supported in part by Spanish Agencia Estatal de Investigacion (MCIN/AEI/10.13039/501100011033) under Grant PID2020-116011RB-C21 and Grant PID2020-116011RB-C22; in part by Universidad de Zaragoza, Fundación Bancaria Ibercaja and Fundación Caja Inmaculada de Aragón under Grant IT 10/22; and in part by Aragon Regional Government through the Program for Research Groups under Grant T27_23R., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Low-power long-term ambulatory electrocardiography monitor of three leads with beat-to-beat heart rate measurement in real time

  • Martínez Suárez, Frank
  • García Limón, José Alberto
  • Baños Bautista, Jorge Enrique
  • Alvarado Serrano, Carlos
  • Casas Piedrafita, Óscar|||0000-0002-0077-0561
A low-power long-term ambulatory ECG monitor was developed for the acquisition, storage and processing of three simultaneous leads DI, aVF and V2 with a beat-to-beat heart rate measurement in real time. It provides long-term continuous ECG recordings until 84 h. The monitor uses a QRS complex detection algorithm based on the continuous wavelet transform with splines, which automatically selects the scale for the analysis of ECG records with different sampling frequencies. It includes a lead-off detection to continuously monitor the electrode connections and a real-time system of visual and acoustic alarms to alert users of abnormal conditions in its operation. The monitor presented is based in an ADS1294 analogue front end with four channels, 24-bit analog-to-digital converters and programmable gain amplifiers, a low-power dual-core ESP32 microcontroller, a microSD memory for data storage in a range of 4 GB to 32 GB and a 1.4 in thin-film transistor liquid crystal display (LCD) variant with a resolution of 128 × 128 pixels. It has programmable sampling rates of 250, 500 and 1000 Hz; a bandwidth of 0 Hz to 50% of the selected sampling rate; a CMRR of -105 dB; an input margin of ±2.4 V; a resolution of 286 nV; and a current consumption of 50 mA for an average battery life of 84 h. The ambulatory ECG monitor was evaluated with the commercial data-acquisition system BIOPAC MP36 and its module for ECG LABEL SS2LB, simultaneously comparing the morphologies of two ECG records and obtaining a correlation of 91.78%. For the QRS detection in real time, the implemented algorithm had an error less than 5%. The developed ambulatory ECG monitor can be used for the analysis of the dynamics of the heart rate variability in long-term ECG records and for the development of one’s own databases of ECG recordings of normal subjects and patients with cardiovascular and noncardiovascular diseases., This work has been funded by a scholarship from the CONAHCYT (México) to Frank Martínez Suárez (No. CVU = 736915), José Alberto García Limón (No. CVU = 924566), Jorge Enrique Baños-Bautista (No. CVU = 1003644) and the Spanish Agencia Estatal de Investigación under grant PID2020-116011RB-C21 (MCIN/AEI/10.13039/501100011033)., Peer Reviewed
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Low-power wireless system for Continuous measurement of cardiovascular parameters on a single limc

  • Gascón, Alberto
  • Serrano-Finetti, Ernesto
  • Marco, Álvaro
  • Casanella, Ramón
  • López-Lapeña, Óscar
  • Hornero, Gemma
  • Casas, Roberto
  • Casas, Óscar
A novel low-power sensor wireless system for continuous and simultaneous measurement of the electrocardiogram (ECG) and the impedance plethysmogram (IPG) from a single limb has been designed and tested. This system is made up of an analog subsystem composed of two signal-conditioning channels, one for the ECG and one for the IPG that share the same voltage pickup electrodes, and a digital subsystem based on the BGM220PC22WGA microcontroller that is responsible for digitizing the signals and sending their data via Bluetooth Low Energy (BLE) to a processing unit. The consumption of the system has been analyzed using different settings, obtaining values that would allow a battery duration of up to 131 h, by performing four 30-s measurements every hour. The system was tested in one arm and one leg in a group of healthy volunteers to verify the functionality and to identify the best electrode positions to get high quality signals. Non-standard ECG leads are obtained in both one arm and one leg with an SNR of more than 30 dB. In the worst case, for measurements on the legs, the mean error of the RR intervals from each recording was 1.7 ms and the 95% confidence interval (±SD) was ±7.3 ms versus a reference system. This has made it possible to accurately obtain the Pulse Arrival Time (PAT) between the ECG and the simultaneously measured IPG signal, which allows more cardiovascular information to be obtained from the patient than with systems that acquire only the ECG signal.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Robust algorithm for the detection and classification of QRS complexes with different morphologies using the continuous spline wavelet transform with automatic scale detection

  • Martínez Suárez, Frank
  • Alvarado Serrano, Carlos
  • Casas Piedrafita, Óscar
This work presents an algorithm for the detection and classification of QRS complexes based on the continuous wavelet transform (CWT) with splines. This approach can evaluate the CWT at any integer scale and the analysis is not restricted to powers of two. The QRS detector comprises four stages: implementation of CWT with splines, detection of QRS complexes, searching for undetected QRS complexes, and correction of the R wave peak location in detected QRS complexes. After, the onsets and ends of the QRS complexes are detected. The algorithm was evaluated with synthetic ECG and with the manually annotated databases: MIT-BIH Arrhythmia, European ST-T, QT and PTB Diagnostic ECG. Evaluation results of the QRS detector were: MIT-BIH arrhythmia database (109,447 beats analyzed), sensitivity Se = 99.72% and positive predictivity P+ = 99.87%; European ST-T database (790522 beats analyzed), Se = 99.92% and P+ = 99.55% and QT database (86498 beats analyzed), Se = 99.97% and P+ = 99.99%. To evaluate the delineation algorithm of the QRS onset (Qi) and QRS end (J) with the QT and PTB Diagnostic ECG databases, the mean and standard deviations of the differences between the automatic and manual annotated location of these points were calculated. The standard deviations were close to the accepted tolerances for deviations determined by the CSE experts. The proposed algorithm is robust to noise, artifacts and baseline drifts, classifies QRS complexes, automatically selects the CWT scale according to the sampling frequency of the ECG record used, and adapts to changes in the heart rate, amplitude and morphology of QRS complexes., This work has been funded by a scholarship from the CONAHCYT (México) to Frank Martínez-Suárez (No. CVU = 736915) and The Spanish Agencia Estatal de Investigación under grant PID2020-116011RBC21 (MCIN / AEI / 10.13039/501100011033)., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Compact, fully differential analog amplitude demodulator by power supply voltage switching

  • Serrano Finetti, Roberto Ernesto
  • Hornero Ocaña, Gemma
  • Casas Piedrafita, Óscar
There is a growing interest in developing impedance sensors able to work at low power and with a small footprint. The analog lock-in amplifier (an amplitude-modulated (AM) demodulator) is a common solution to recover the baseband signal from modulating sensors while avoiding low-frequency noise. However, it uses several active components whose total power consumption might shorten battery life. In this work, we propose a simple AM demodulator based on a fully differential switched-gain amplifier. Using op amps with shutdown enables the gain switching between 0 and 1, which recovers the baseband signal in a similar way to a conventional +1/-1 switched gain amplifier, but with a 50% amplitude decrease in the demodulated signal. By using a power-down signal synchronized with the carrier, it is possible to program a 0° or 90° phase that enables in-phase and quadrature demodulation, ultimately allowing the measurement of complex impedances. Tests were performed in two different situations: static and time-varying impedances, and with two different op amp models, the OPA363 and the ADA4806-1. In the former test, several resistors and capacitors were measured, yielding deviations from a reference instrument below 0.5% for resistors and below 2.7% for capacitors when using the OPA363. In the latter test, the electrical bioimpedance changes of the hand-to-hand body segment of a number of healthy volunteers were recorded, enabling the detection of the respiratory and pulse rate., This work was supported by the Spanish Agencia Estatal de Investigación under Grant PID2020-116011RB-C21 (MCIN/AEI/10.13039/501100011033)., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Low-power long-term ambulatory electrocardiography monitor of three leads with beat-to-beat heart rate measurement in real time

  • Martínez Suárez, Frank
  • García Limón, José Alberto
  • Baños Bautista, Jorge Enrique
  • Alvarado Serrano, Carlos
  • Casas Piedrafita, Óscar
A low-power long-term ambulatory ECG monitor was developed for the acquisition, storage and processing of three simultaneous leads DI, aVF and V2 with a beat-to-beat heart rate measurement in real time. It provides long-term continuous ECG recordings until 84 h. The monitor uses a QRS complex detection algorithm based on the continuous wavelet transform with splines, which automatically selects the scale for the analysis of ECG records with different sampling frequencies. It includes a lead-off detection to continuously monitor the electrode connections and a real-time system of visual and acoustic alarms to alert users of abnormal conditions in its operation. The monitor presented is based in an ADS1294 analogue front end with four channels, 24-bit analog-to-digital converters and programmable gain amplifiers, a low-power dual-core ESP32 microcontroller, a microSD memory for data storage in a range of 4 GB to 32 GB and a 1.4 in thin-film transistor liquid crystal display (LCD) variant with a resolution of 128 × 128 pixels. It has programmable sampling rates of 250, 500 and 1000 Hz; a bandwidth of 0 Hz to 50% of the selected sampling rate; a CMRR of -105 dB; an input margin of ±2.4 V; a resolution of 286 nV; and a current consumption of 50 mA for an average battery life of 84 h. The ambulatory ECG monitor was evaluated with the commercial data-acquisition system BIOPAC MP36 and its module for ECG LABEL SS2LB, simultaneously comparing the morphologies of two ECG records and obtaining a correlation of 91.78%. For the QRS detection in real time, the implemented algorithm had an error less than 5%. The developed ambulatory ECG monitor can be used for the analysis of the dynamics of the heart rate variability in long-term ECG records and for the development of one’s own databases of ECG recordings of normal subjects and patients with cardiovascular and noncardiovascular diseases., This work has been funded by a scholarship from the CONAHCYT (México) to Frank Martínez Suárez (No. CVU = 736915), José Alberto García Limón (No. CVU = 924566), Jorge Enrique Baños-Bautista (No. CVU = 1003644) and the Spanish Agencia Estatal de Investigación under grant PID2020-116011RB-C21 (MCIN/AEI/10.13039/501100011033)., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Low-power wireless system for continuous measurement of cardiovascular parameters on a single limb

  • Gascón Roche, Alberto
  • Serrano Finetti, Roberto Ernesto
  • Marco Marco, Álvaro
  • Casanella Alonso, Ramón
  • López Lapeña, Oscar
  • Hornero Ocaña, Gemma
  • Casas Nebra, Roberto
  • Casas Piedrafita, Óscar
A novel low-power sensor wireless system for continuous and simultaneous measurement of the electrocardiogram (ECG) and the impedance plethysmogram (IPG) from a single limb has been designed and tested. This system is made up of an analog subsystem composed of two signal-conditioning channels, one for the ECG and one for the IPG that share the same voltage pickup electrodes, and a digital subsystem based on the BGM220PC22WGA microcontroller that is responsible for digitizing the signals and sending their data via Bluetooth Low Energy (BLE) to a processing unit. The consumption of the system has been analyzed using different settings, obtaining values that would allow a battery duration of up to 131 h, by performing four 30-s measurements every hour. The system was tested in one arm and one leg in a group of healthy volunteers to verify the functionality and to identify the best electrode positions to get high quality signals. Non-standard ECG leads are obtained in both one arm and one leg with an SNR of more than 30 dB. In the worst case, for measurements on the legs, the mean error of the RR intervals from each recording was 1.7 ms and the 95% confidence interval (±SD) was ±7.3 ms versus a reference system. This has made it possible to accurately obtain the Pulse Arrival Time (PAT) between the ECG and the simultaneously measured IPG signal, which allows more cardiovascular information to be obtained from the patient than with systems that acquire only the ECG signal., This work was supported in part by Spanish Agencia Estatal de Investigacion (MCIN/AEI/10.13039/501100011033) under Grant PID2020-116011RB-C21 and Grant PID2020-116011RB-C22; in part by Universidad de Zaragoza, Fundación Bancaria Ibercaja and Fundación Caja Inmaculada de Aragón under Grant IT 10/22; and in part by Aragon Regional Government through the Program for Research Groups under Grant T27_23R., Peer Reviewed, Postprint (published version)