DEEPENING KNOWLEDGE AND IMPROVING THE QUALITY OF LIFE IN PARKINSON DISEASE THROUGH SMART INSOLES (MYGAIT_SENSORS)

PID2020-116011RB-C22

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2020
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDAD DE ZARAGOZA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 8
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Enhanced power-point tracking for high-hysteresis perovskite solar cells with a galvanostatic approach

  • Juárez-Pérez, Emilio J.
  • Momblona, Cristina
  • Casas, Roberto
  • Haro, Marta
Harnessing the untapped potential of solar energy sources is crucial for achieving a sustainable future, and accurate maximum-power-point tracking of solar cells is vital to maximizing their power generation. This article introduces a power-tracking algorithm and cost-effective hardware for long-term operational stability measurements in perovskite solar cells. Existing algorithms for photovoltaic technology lead to suboptimal performance when applied to the most stable perovskite devices (for example, triple-mesoscopic hole-transport-material-free metal halide perovskite solar cells). To address this challenge, we developed a low-cost hardware solution for research purposes that enables concurrent long-term stability measurements in parallel with a galvanostatic-type power-tracking algorithm, ensuring superior operational performance for high-hysteresis perovskite solar cells. The suggested enhancements bear significant implications for the extensive integration of perovskite solar-cell technologies, particularly those dependent on power-optimizer devices., Authors acknowledge the funding support from MCIN/AEI/10.13039/501100011033 and European Union NextGenerationEU/PRTR for project grants PID2022-140516OB-I00 (E.J.J.-P. and M.H.), PID2019-107893RB-I00 (E.J.J.-P.), PID2020-116011RB-C22 (R.C.), EIN2020-112315 (E.J.J.-P.), and PID2019-108247RA-I00 (M.H.) and fellowships from Ramón y Cajal (RYC-2018-025222-I; M.H.) and Juan de la Cierva Incorporación (IJC-2020-044684-I; C.M.) Also, authors acknowledge the funding support from the Aragon Regional Government for the Program for Research Groups under grant: T57_23R (E.J.J.-P. and C.M.), E31_20R (M.H.), and T27_23R (R.C.)., Peer reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Artículo científico (JournalArticle)

Low-power wireless system for continuous measurement of cardiovascular parameters on a single limb

  • Gascón Roche, Alberto
  • Serrano Finetti, Roberto Ernesto|||0000-0002-5628-5426
  • Marco Marco, Álvaro
  • Casanella Alonso, Ramón|||0000-0003-2995-7132
  • López Lapeña, Oscar|||0000-0002-6024-0722
  • Hornero Ocaña, Gemma|||0000-0002-2998-3173
  • Casas Nebra, Roberto
  • Casas Piedrafita, Óscar|||0000-0002-0077-0561
A novel low-power sensor wireless system for continuous and simultaneous measurement of the electrocardiogram (ECG) and the impedance plethysmogram (IPG) from a single limb has been designed and tested. This system is made up of an analog subsystem composed of two signal-conditioning channels, one for the ECG and one for the IPG that share the same voltage pickup electrodes, and a digital subsystem based on the BGM220PC22WGA microcontroller that is responsible for digitizing the signals and sending their data via Bluetooth Low Energy (BLE) to a processing unit. The consumption of the system has been analyzed using different settings, obtaining values that would allow a battery duration of up to 131 h, by performing four 30-s measurements every hour. The system was tested in one arm and one leg in a group of healthy volunteers to verify the functionality and to identify the best electrode positions to get high quality signals. Non-standard ECG leads are obtained in both one arm and one leg with an SNR of more than 30 dB. In the worst case, for measurements on the legs, the mean error of the RR intervals from each recording was 1.7 ms and the 95% confidence interval (±SD) was ±7.3 ms versus a reference system. This has made it possible to accurately obtain the Pulse Arrival Time (PAT) between the ECG and the simultaneously measured IPG signal, which allows more cardiovascular information to be obtained from the patient than with systems that acquire only the ECG signal., This work was supported in part by Spanish Agencia Estatal de Investigacion (MCIN/AEI/10.13039/501100011033) under Grant PID2020-116011RB-C21 and Grant PID2020-116011RB-C22; in part by Universidad de Zaragoza, Fundación Bancaria Ibercaja and Fundación Caja Inmaculada de Aragón under Grant IT 10/22; and in part by Aragon Regional Government through the Program for Research Groups under Grant T27_23R., Peer Reviewed
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Wireless standard-compliant e-health solution for elderly people with multiuser identification

  • Martínez, Ignacio
  • González, Francisco
Objective: One of the main problems in e-health environments for developing an accurate multiuser identification is in the large number of patients, especially with itinerant medical devices and elderly people. This paper aims to contribute with two approaches to be included in ISO/IEEE 11073 family of standards as a standardized procedure for multiuser identification that can be used for a large variety of medical devices, regardless of their brand or model. From this contribution and to validate it, this work proposes a standardized e-health solution, including multiuser identification, implementing it in real health environments for elderly people, and evaluating their usability, interoperability, and adoption in daily living. Materials and methods: This works implements the internationally recommended Personal Health Devices ISO/IEEE 11073 standards as a multiplatform environment (Windows/Linux/Mac OS) and fulfils the paradigms of scalability, modularity, portability, maintainability, and robustness. The standard e-health solution has been implemented in 26 health environments in several cities in Spain (Madrid, Barcelona, Sevilla, Zaragoza, etc.), consisting of 118 health professionals, 319 senior patients, and 18 technical professionals. Results: The proposed multiuser identification reduces the human error rate (from 13.3% to less than 5%) with positive evaluation: almost 70% of users are satisfied, with usability and time savings that are more than 50% in all the groups (nursing, medicine, and caregiving) and environments (residences, health centres, and hospitals). Discussion: The use of e-health solutions within multiuser identification, as it is proposed through two standard-compliant approaches, permits advanced services and data analysis for a large variety of medical devices, regardless of their brand or model. Conclusion: This paper contributes an open interoperable e-health solution as alternative to the closed and commercial solutions and enables third-party developers to work collaboratively and extend the already implemented features, owing to the design based on plugins, value-added services, and multiple transport technologies and protocols.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Low-power wireless system for Continuous measurement of cardiovascular parameters on a single limc

  • Gascón, Alberto
  • Serrano-Finetti, Ernesto
  • Marco, Álvaro
  • Casanella, Ramón
  • López-Lapeña, Óscar
  • Hornero, Gemma
  • Casas, Roberto
  • Casas, Óscar
A novel low-power sensor wireless system for continuous and simultaneous measurement of the electrocardiogram (ECG) and the impedance plethysmogram (IPG) from a single limb has been designed and tested. This system is made up of an analog subsystem composed of two signal-conditioning channels, one for the ECG and one for the IPG that share the same voltage pickup electrodes, and a digital subsystem based on the BGM220PC22WGA microcontroller that is responsible for digitizing the signals and sending their data via Bluetooth Low Energy (BLE) to a processing unit. The consumption of the system has been analyzed using different settings, obtaining values that would allow a battery duration of up to 131 h, by performing four 30-s measurements every hour. The system was tested in one arm and one leg in a group of healthy volunteers to verify the functionality and to identify the best electrode positions to get high quality signals. Non-standard ECG leads are obtained in both one arm and one leg with an SNR of more than 30 dB. In the worst case, for measurements on the legs, the mean error of the RR intervals from each recording was 1.7 ms and the 95% confidence interval (±SD) was ±7.3 ms versus a reference system. This has made it possible to accurately obtain the Pulse Arrival Time (PAT) between the ECG and the simultaneously measured IPG signal, which allows more cardiovascular information to be obtained from the patient than with systems that acquire only the ECG signal.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Enhanced power-point tracking for high-hysteresis perovskite solar cells with a galvanostatic approach

  • Juarez-Perez, Emilio J.
  • Momblona, Cristina
  • Casas, Roberto
  • Haro, Marta
Harnessing the untapped potential of solar energy sources is crucial for achieving a sustainable future, and accurate maximum-power-point tracking of solar cells is vital to maximizing their power generation. This article introduces a power-tracking algorithm and cost-effective hardware for long-term operational stability measurements in perovskite solar cells. Existing algorithms for photovoltaic technology lead to suboptimal performance when applied to the most stable perovskite devices (for example, triple-mesoscopic hole-transport-material-free metal halide perovskite solar cells). To address this challenge, we developed a low-cost hardware solution for research purposes that enables concurrent long-term stability measurements in parallel with a galvanostatic-type power-tracking algorithm, ensuring superior operational performance for high-hysteresis perovskite solar cells. The suggested enhancements bear significant implications for the extensive integration of perovskite solar-cell technologies, particularly those dependent on power-optimizer devices.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

A diagnostic and performance system for soccer: technical design and development

  • Gascón, Alberto
  • Marco, Álvaro
  • Buldain, David
  • Alfaro-Santafé, Javier
  • Alfaro-Santafé, José Víctor
  • Gómez-Bernal, Antonio
  • Casas, Roberto
This study presents a novel system for diagnosing and evaluating soccer performance using wearable inertial sensors integrated into players’ insoles. Designed to meet the needs of professional podiatrists and sports practitioners, the system focuses on three key soccer-related movements: passing, shooting, and changes of direction (CoDs). The system leverages low-power IMU sensors, Bluetooth Low Energy (BLE) communication, and a cloud-based architecture to enable real-time data analysis and performance feedback. Data were collected from nine professional players from the SD Huesca women’s team during controlled tests, and bespoke algorithms were developed to process kinematic data for precise event detection. Results indicate high accuracy rates for detecting ball-striking events and CoDs, with improvements in algorithm performance achieved through adaptive thresholds and ensemble neural network models. Compared to existing systems, this approach significantly reduces costs and enhances practicality by minimizing the number of sensors required while ensuring real-time evaluation capabilities. However, the study is limited by a small sample size, which restricts generalizability. Future research will aim to expand the dataset, include diverse sports, and integrate additional sensors for broader applications. This system offers a valuable tool for injury prevention, player rehabilitation, and performance optimization in professional soccer, bridging technical advancements with practical applications in sports science.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

A smart container for real-time load occupancy estimation using embedded neural inference

  • Remón, Diego
  • Gascón, Alberto
  • Marco, Álvaro
  • Blanco, Teresa
  • Casas, Roberto
The increasing demand for sustainable urban delivery solutions has driven the adoption of cargo bikes due to their environmental benefits and adaptability to congested urban environments. These operations benefit from monitoring systems capable of estimating load occupancy (volume) to support logistical decision-making. This study presents a smart-container approach for real-time occupancy estimation using two Time-of-Flight (TOF) sensors and a compact neural model deployed on an ESP32-S3 microcontroller. TOF sensors generate distance matrices of the internal cargo space, which are processed to estimate occupied volume via the normalized FreeSpace target. In two inference stress tests, the system achieves 2 = 0.929 and 0.923, with mean absolute error (MAE) = 0.044 on the normalized FreeSpace scale (0–1), equivalent to 8.1 dm3 (4.4% of container capacity). The results support the feasibility of low-cost embedded inference for operational capacity checks in cargo-bike logistics.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Low-power wireless system for continuous measurement of cardiovascular parameters on a single limb

  • Gascón Roche, Alberto
  • Serrano Finetti, Roberto Ernesto
  • Marco Marco, Álvaro
  • Casanella Alonso, Ramón
  • López Lapeña, Oscar
  • Hornero Ocaña, Gemma
  • Casas Nebra, Roberto
  • Casas Piedrafita, Óscar
A novel low-power sensor wireless system for continuous and simultaneous measurement of the electrocardiogram (ECG) and the impedance plethysmogram (IPG) from a single limb has been designed and tested. This system is made up of an analog subsystem composed of two signal-conditioning channels, one for the ECG and one for the IPG that share the same voltage pickup electrodes, and a digital subsystem based on the BGM220PC22WGA microcontroller that is responsible for digitizing the signals and sending their data via Bluetooth Low Energy (BLE) to a processing unit. The consumption of the system has been analyzed using different settings, obtaining values that would allow a battery duration of up to 131 h, by performing four 30-s measurements every hour. The system was tested in one arm and one leg in a group of healthy volunteers to verify the functionality and to identify the best electrode positions to get high quality signals. Non-standard ECG leads are obtained in both one arm and one leg with an SNR of more than 30 dB. In the worst case, for measurements on the legs, the mean error of the RR intervals from each recording was 1.7 ms and the 95% confidence interval (±SD) was ±7.3 ms versus a reference system. This has made it possible to accurately obtain the Pulse Arrival Time (PAT) between the ECG and the simultaneously measured IPG signal, which allows more cardiovascular information to be obtained from the patient than with systems that acquire only the ECG signal., This work was supported in part by Spanish Agencia Estatal de Investigacion (MCIN/AEI/10.13039/501100011033) under Grant PID2020-116011RB-C21 and Grant PID2020-116011RB-C22; in part by Universidad de Zaragoza, Fundación Bancaria Ibercaja and Fundación Caja Inmaculada de Aragón under Grant IT 10/22; and in part by Aragon Regional Government through the Program for Research Groups under Grant T27_23R., Peer Reviewed, Postprint (published version)