Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 7
Encontrada(s) 1 página(s)

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Low-power wireless system for Continuous measurement of cardiovascular parameters on a single limc

  • Gascón, Alberto
  • Serrano-Finetti, Ernesto
  • Marco, Álvaro
  • Casanella, Ramón
  • López-Lapeña, Óscar
  • Hornero, Gemma
  • Casas, Roberto
  • Casas, Óscar
A novel low-power sensor wireless system for continuous and simultaneous measurement of the electrocardiogram (ECG) and the impedance plethysmogram (IPG) from a single limb has been designed and tested. This system is made up of an analog subsystem composed of two signal-conditioning channels, one for the ECG and one for the IPG that share the same voltage pickup electrodes, and a digital subsystem based on the BGM220PC22WGA microcontroller that is responsible for digitizing the signals and sending their data via Bluetooth Low Energy (BLE) to a processing unit. The consumption of the system has been analyzed using different settings, obtaining values that would allow a battery duration of up to 131 h, by performing four 30-s measurements every hour. The system was tested in one arm and one leg in a group of healthy volunteers to verify the functionality and to identify the best electrode positions to get high quality signals. Non-standard ECG leads are obtained in both one arm and one leg with an SNR of more than 30 dB. In the worst case, for measurements on the legs, the mean error of the RR intervals from each recording was 1.7 ms and the 95% confidence interval (±SD) was ±7.3 ms versus a reference system. This has made it possible to accurately obtain the Pulse Arrival Time (PAT) between the ECG and the simultaneously measured IPG signal, which allows more cardiovascular information to be obtained from the patient than with systems that acquire only the ECG signal.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Enhanced power-point tracking for high-hysteresis perovskite solar cells with a galvanostatic approach

  • Juarez-Perez, Emilio J.
  • Momblona, Cristina
  • Casas, Roberto
  • Haro, Marta
Harnessing the untapped potential of solar energy sources is crucial for achieving a sustainable future, and accurate maximum-power-point tracking of solar cells is vital to maximizing their power generation. This article introduces a power-tracking algorithm and cost-effective hardware for long-term operational stability measurements in perovskite solar cells. Existing algorithms for photovoltaic technology lead to suboptimal performance when applied to the most stable perovskite devices (for example, triple-mesoscopic hole-transport-material-free metal halide perovskite solar cells). To address this challenge, we developed a low-cost hardware solution for research purposes that enables concurrent long-term stability measurements in parallel with a galvanostatic-type power-tracking algorithm, ensuring superior operational performance for high-hysteresis perovskite solar cells. The suggested enhancements bear significant implications for the extensive integration of perovskite solar-cell technologies, particularly those dependent on power-optimizer devices.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

A diagnostic and performance system for soccer: technical design and development

  • Gascón, Alberto
  • Marco, Álvaro
  • Buldain, David
  • Alfaro-Santafé, Javier
  • Alfaro-Santafé, José Víctor
  • Gómez-Bernal, Antonio
  • Casas, Roberto
This study presents a novel system for diagnosing and evaluating soccer performance using wearable inertial sensors integrated into players’ insoles. Designed to meet the needs of professional podiatrists and sports practitioners, the system focuses on three key soccer-related movements: passing, shooting, and changes of direction (CoDs). The system leverages low-power IMU sensors, Bluetooth Low Energy (BLE) communication, and a cloud-based architecture to enable real-time data analysis and performance feedback. Data were collected from nine professional players from the SD Huesca women’s team during controlled tests, and bespoke algorithms were developed to process kinematic data for precise event detection. Results indicate high accuracy rates for detecting ball-striking events and CoDs, with improvements in algorithm performance achieved through adaptive thresholds and ensemble neural network models. Compared to existing systems, this approach significantly reduces costs and enhances practicality by minimizing the number of sensors required while ensuring real-time evaluation capabilities. However, the study is limited by a small sample size, which restricts generalizability. Future research will aim to expand the dataset, include diverse sports, and integrate additional sensors for broader applications. This system offers a valuable tool for injury prevention, player rehabilitation, and performance optimization in professional soccer, bridging technical advancements with practical applications in sports science.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Towards Effective Wearable Design: 20 Key Factors for Monitoring Physiological Health in Animals

  • Siguín, Marta
  • Casas, Roberto
  • Casas, Oscar
  • Blanco, Teresa
Robust physiological biosensing in animals is valuable for improving health monitoring and advancing animal welfare. However, the design of wearable devices for this purpose faces significant challenges affecting measurement accuracy and user acceptance. These include insufficient adaptation to the specific characteristics of the animal user, limitations in measurement methods, and a lack of standardised documentation regarding usage conditions. This study presents the 20-Factors Framework, a comprehensive framework based on 20 critical factors for designing and evaluating biosensing wearables for continuous physiological monitoring in animals, with a focus on dogs and cats. Developed through a systematic literature review and real-world project participation, the framework is structured using the 5Ws+1H Method (Who, Why, What, When, Where, How), enabling the identification of design gaps and the analysis of interactions between key factors shaping both the physical and functional aspects of these systems. To validate its applicability, a case study on thermal stress monitoring in cats illustrates how these factors can be practically integrated, reinforcing the framework’s relevance for research and industry applications. The findings underscore the importance of considering Animal-Computer Interaction (ACI) through Animal-Centred Design (ACD) to ensure that biosensing technologies are aligned with the needs of the animal user—maximising precision, functionality, and acceptability. This work establishes a solid foundation for future research and innovation in biosensing wearables, offering opportunities for implementation across different species and environments while promoting stricter standards in engineering applications.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Assessment of Myofascial Trigger Points with ultrasound: a methodology combining external vibration with Power Doppler Imaging and B-mode

  • Herrero, Pablo
  • Lapuente-Hernández, Diego
  • Blanco, Teresa
  • Casas, Roberto
  • Valera-Garrido, Fermín
  • Minaya-Muñoz, Francisco
  • Gomes Monres, Jose
  • Gómez-Trullén, Eva María
Introduction: This case series explores a novel methodology for identifying myofascial trigger points (MTrPs) by integrating Doppler and B-mode ultrasound with externally applied vibratory stimulation. The study aims to address the current lack of accessible and objective tools for MTrP assessment in clinical settings. Case presentation: Five participants were included: four healthy individuals and one post-stroke patient. A custom-designed vibration device was developed to apply mechanical stimulation to the gastrocnemius medialis muscle, while ultrasound imaging was collected using a standardized setup. To optimize vibration signal detection within muscle tissue, different configurations of the electrodes transmitting the vibration and the Doppler modes (Color Doppler and Power Doppler Imaging (PDI)) were tested. Results: PDI demonstrated superior sensitivity to vibration-induced muscle responses compared to conventional Color Doppler. A consistent pattern was identified among healthy participants. This pattern consisted of well-defined, non-vibratory zones surrounded by vibratory regions, corresponding to hypoechoic areas on B-mode ultrasound. These findings are suggestive of MTrPs and distinct from other stiff anatomical structures, such as fascia, tendons, or fibrotic tissue, which appear hyperechoic. In the stroke patient, pathological muscle adaptations reduced the consistency and visibility of vibratory stimulus propagation; however, MTrP-compatible areas were still identified. Notably, dry needling altered the Doppler signal in this case, attenuating the previously observed pattern. Conclusions: This proof-of-concept study demonstrates the feasibility and reproducibility of a cost-effective assessment protocol that uses conventional ultrasound modes. Combining PDI, B-mode, and vibration may improve the objective identification of MTrPs and expand capabilities in musculoskeletal practice.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

A smart container for real-time load occupancy estimation using embedded neural inference

  • Remón, Diego
  • Gascón, Alberto
  • Marco, Álvaro
  • Blanco, Teresa
  • Casas, Roberto
The increasing demand for sustainable urban delivery solutions has driven the adoption of cargo bikes due to their environmental benefits and adaptability to congested urban environments. These operations benefit from monitoring systems capable of estimating load occupancy (volume) to support logistical decision-making. This study presents a smart-container approach for real-time occupancy estimation using two Time-of-Flight (TOF) sensors and a compact neural model deployed on an ESP32-S3 microcontroller. TOF sensors generate distance matrices of the internal cargo space, which are processed to estimate occupied volume via the normalized FreeSpace target. In two inference stress tests, the system achieves 2 = 0.929 and 0.923, with mean absolute error (MAE) = 0.044 on the normalized FreeSpace scale (0–1), equivalent to 8.1 dm3 (4.4% of container capacity). The results support the feasibility of low-cost embedded inference for operational capacity checks in cargo-bike logistics.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

IoT‐Based Real‐Time Monitoring Ecosystem on Smart Campus: Contributions for Infrastructure Deployment, CO <sub>2</sub> ‐Based Ventilation, and Data‐Driven Decisions

  • Martínez, Ignacio
  • Cano, Enrique
  • Marco, Álvaro
  • Fernández, Ángel
This paper addresses three indoor air quality (IAQ) challenges in large‐scale infrastructures under real operational conditions. First, methodological procedures for CO2. This paper addresses three indoor air quality (IAQ) challenges in large-scale infrastructures under real operational conditions. First, methodological procedures for CO2 monitors: selection according to their key features, strategic placement to guarantee data quality, and calibration to ensure long-term consistency and second, real-time monitoring through a campus-scale Internet of Things (IoT) ecosystem, yielding the following contributions. A monitoring map is used to comprehensively classify spaces by fulfilling international recommendations. An IAQ study highlights the combined influence of occupancy, size, and contextual factors. And an analysis of CO2 performance understands interactions between building operation and human behavior. Finally, for each contribution this paper proposes extrapolatable and replicable strategies to move toward data-driven decisions for efficient IAQ management in tertiary buildings.