Pasar al contenido principal

DESARROLLO DE ARQUITECTURAS Y TECNOLOGIAS FUTURAS HACIA LA RED 5G

TEC2014-60258-C2-1-R

•
Nombre agencia financiadora Ministerio de Economía y Competitividad
Acrónimo agencia financiadora MINECO
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos I+D+i Retos de Investigación
Año convocatoria 2014
Plan Estatal 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Unidad de gestión Secretaría de Estado de Educación, Formación Profesional y Universidades
Centro beneficiario UNIVERSITAT POLITÈCNICA DE VALÈNCIA
Identificador persistente http://dx.doi.org/10.13039/501100003329

Resultados relacionados

Resultados totales (Incluyendo duplicados): 14
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Dielectric characterization of healthy and malignant colon tissues in the 0.5 18 GHz frequency band

  • Fornés Leal, Alejandro|||0000-0001-5914-6045
  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
  • Cardona Marcet, Narciso|||0000-0001-5697-1453
  • Frasson, M.
  • Pons Beltrán, Vicente
Several reports over the last few decades have shown that the dielectric properties of healthy and malignant tissues of the same body organ usually show different values. However, no intensive dielectric studies of human colon tissue have been performed, despite colon cancer's being one of the most common types of cancer in the world. In order to provide information regarding this matter, a dielectric characterization of healthy and malignant colon tissues is presented. Measurements are performed on ex vivo surgery samples obtained from 20 patients, using an open-ended coaxial probe in the 0.5 18 GHz frequency band. Results show that the dielectric constant of colon cancerous tissue is 8.8% higher than that of healthy tissues (p = 0.002). Besides, conductivity is about 10.6% higher, but in this case measurements do not have statistical significance (p = 0.038). Performing an analysis per patient, the differences in dielectric constant between healthy and malignant tissues appear systematically. Particularized results for specific frequencies (500 MHz, 900 MHz, 2.45 GHz, 5 GHz, 8.5 GHz and 15 GHz) are also reported. The findings have potential application in early-stage cancer detection and diagnosis, and can be useful in developing new tools for hyperthermia treatments as well as creating electromagnetic models of healthy and cancerous tissues., The authors would like to thank the medical staff of the endoscopy unit of Hospital Universitari i Politecnic La Fe for their assistance in the gathering of tissue samples. This work was supported by Ministerio de Economia y Competitividad, Spain (ref. TEC2014-60258-C2-1-R, TEC2014-56469-REDT), by FEDER funds, and by a UPV-IISLaFe action (CEI-2G, 2014).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Frequency Dependence of UWB In-Body Radio Channel Characteristics

  • Andreu-Estellés, Carlos
  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
  • Castelló-Palacios, Sergio|||0000-0003-4689-652X
  • Vallés Lluch, Ana|||0000-0002-7896-8666
  • Cardona Marcet, Narciso|||0000-0001-5697-1453
[EN] In this letter, a research of ultra-wideband in-body channel by using a high accurate phantom is performed in order to evaluate the impact of frequency dependence of human tissues on the channel characteristics. Hence, a phantom-based measurement campaign from 3.1 to 5.1 GHz has been conducted. From postprocessing data, the path loss is assessed considering subbands of 500 MHz as well as the entire frequency range under test. In addition, the correlation in transmission is computed and discussed., This work was supported in part by the Ministerio de Economia y Competitividad, Spain, under Grant TEC2014-60258-C2-1-R, and in part by the European FEDER funds. (Corresponding author: Carlos Andreu.)
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Non-Coherent Open-Loop MIMO Communications Over Temporally-Correlated Channels

  • Cabrejas Peñuelas, Jorge
  • Roger Varea, Sandra
  • Fouad, Yaser M. M.
  • Gohary, Ramy H.
  • Yanikomeroglu, Halim
  • Calabuig Soler, Daniel|||0000-0003-0611-9902
  • Monserrat del Río, Jose Francisco|||0000-0001-8664-6408
[EN] This paper investigates the use of non-coherent communication techniques for open-loop transmission over temporally-correlated Rayleigh-fading MIMO channels. These techniques perform data detection without knowing the instantaneous channel coefficients. Three non-coherent Multiple Input Multiple Output (MIMO) schemes, namely, differential unitary space-time modulation, differential space-time block code, and Grassmannian signaling, are compared with several state-of-the-art training-based coherent schemes. This paper shows that the non-coherent schemes are meaningful alternatives to training-based communication, specially as the number of transmit antennas increases. In particular, for more than two transmit antennas, non-coherent communication provides a clear advantage in medium to high mobility scenarios., This work was supported in part by the Ministerio de Economia y Competitividad, Spain, under Grant TEC2014-60258-C2-1-R, in part by the European Regional Development Fund, in part by the European Union through the H2020 Project METIS-II under Grant 671680, in part by Huawei Canada Company, Ltd., and in part by the Ontario Ministry of Economic Development and Innovation's through the Ontario Research Fund-Research Excellence Program.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Spectrum Sharing for LTE-A and DTT: Field Trials of an Indoor LTE-A Femtocell in DVB-T2 Service Area

  • Martínez Pinzón, Gerardo
  • Ribadeneira-Ramírez, Jefferson Alexander
  • Cardona Marcet, Narciso|||0000-0001-5697-1453
  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
  • Fornés Leal, Alejandro|||0000-0001-5914-6045
In this paper, we study a particular case which goes a step beyond the previous ones, as it aims at sharing the same frequency band in the same area between long term evolution-advance (LTE-A) and digital video broadcasting-terrestrial second generation (DVB-T2) technologies. Those geographical areas that are not covered because the useful DTT signal is obstructed by the environment or it has a limited coverage by the network design can be called micro-TVWS. We assume that a DVB-T2 transmitter provides coverage for fixed rooftop reception as a primary service, to a building in which a LTE-A femtocell is installed indoors for local coverage, as a secondary service. The results have been obtained by laboratory emulation and validated through field measurements using professional equipment. Our results provide the technical restrictions of the LTE-A femtocell, mainly on the maximum allowable effective isotropic radiated power that could transmit on the DTT band in terms of carrier separation, from co-channel to adjacent band. These results meet the need of spectrum for IMT-Advanced technologies, so spectrum sharing is proposed in this paper as a new solution to make an efficient use of this resource., This work was supported in part by the Ministerio de Educacion y Ciencia, Spain, under Grant "DEFINE5G" TEC2014-60258-C2-1-R and Grant "ARCO5G" TEC2014-56469-REDT, and in part by the European FEDER Funds.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Tailor-Made Tissue Phantoms Based on Acetonitrile Solutions for Microwave Applications up to 18 GHz

  • Castelló-Palacios, Sergio|||0000-0003-4689-652X
  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
  • Fornés Leal, Alejandro|||0000-0001-5914-6045
  • Cardona Marcet, Narciso|||0000-0001-5697-1453
  • Vallés Lluch, Ana|||0000-0002-7896-8666
Tissue-equivalent phantoms play a key role in the development of new wireless communication devices that are tested on such phantoms prior to their commercialization. However, existing phantoms cover a small number of tissues and do not reproduce them accurately within wide frequency bands. This paper aims at enlarging the number of mimicked tissues as well as their working frequency band. Thus, a variety of potential compounds are scanned according to their relative permittivity from 0.5 to 18 GHz. Next, a combination of these compounds is characterized so the relation between their dielectric properties and composition is provided. Finally, taking advantage of the previous analysis, tailor-made phantoms are developed for different human tissues up to 18 GHz and particularized for the main current body area network (BAN) operating bands. The tailor-made phantoms presented here exhibit such a high accuracy as would allow researchers and manufacturers to test microwave devices at high frequencies for large bandwidths as well as the use of heterogeneous phantoms in the near future. The key to these phantoms lies in the incorporation of acetonitrile to aqueous solutions. Such compounds have a suitable behavior to achieve the relative permittivity values of body tissues within the studied frequency band., This work was supported by the Ministerio de Economia y Competitividad, Spain (TEC2014-60258-C2-1-R) and by the European FEDER Funds.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Multicarrier Waveform Harmonization and Complexity Analysis for an Efficient 5G Air Interface Implementation

  • Garcia-Roger, David
  • Roger Varea, Sandra
  • Flores De Valgas, Josue
  • Monserrat del Río, Jose Francisco|||0000-0001-8664-6408
[EN] The coexistence of multiple air interface variants in the upcoming fifth generation (5G) wireless technology remains a matter of ongoing discussion. This paper focuses on the physical layer of the 5G air interface and provides a harmonization solution for the joint implementation of several multicarrier waveform candidates. Waveforms based either on cyclic prefix-orthogonal frequency division multiplexing (CP-OFDM) or on filter bank multicarrier (FBMC) are first presented through a harmonized system model. Complexity comparisons among five different waveforms are provided. Then, the complexity of a proposed configurable hardware implementation setup for waveform transmission and reception is evaluated. As a result, the harmonized transmitter and receiver exhibit 25¿40% and 15¿25% less complexity in floating-point operations, respectively, in comparison to two standalone implementations of the most complex waveform instances of the CP-OFDM and FBMC families. This highlights the similarities between both families and illustrates the component reuse advantages associated with the proposed harmonized solution., This work was performed in the framework of the H2020 Project METIS-II with reference 671680, which is partly funded by the European Union. The authors would like to acknowledge the contributions of their colleagues in METIS-II. This work was also supported in part by the Ministerio de Economia y Competitividad, under Grant TEC2014-60258-C2-1-R.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Doppler Characterization in Ultra Wideband BAN Channels During Breathing

  • García-Serna, Rubén Gregorio
  • Molina-García-Pardo, José María
  • JUAN LLACER, LEANDRO
  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
  • Cardona Marcet, Narciso|||0000-0001-5697-1453
[EN] Monitoring the physical parameters from devices inside the body, using ultra wideband (UWB) technology, enables the development of high bandwidth demanding applications in real time. The relative movement of the nodes deployed in the body, due to breathing, can give rise to a frequency shifting effect, increasing the fading level in the propagation channel during transmissions. In this article, therefore, we present a study of the frequency effects on the propagation channel derived from the relative movement between two nodes of a wireless body area network (WBAN), at least one of them placed inside the human body, caused by breathing. The study is performed on the basis of the Doppler spectrum characterization in terms of the shape fitting and frequency spread parameter derivation. Continuous wave (CW) signals have been used to cover the UWB range at four selected frequencies: 3.1, 4.8, 6, and 8.5 GHz, and a liquid phantom has been employed for emulating the dielectric properties of the high water content tissues at the considered UWB frequencies., This work was supported in part by the Ministerio de Economia y Competitividad (MINECO), Spain, under Grant TEC2016-78028-C3-2-P, in part by the European Union's H2020-MSCA-ITN Program by the "mmWave Communications in the Built Environments-WaveComBE" Project, under Grant 766231, and in part by the European FEDER funds.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Performance evaluation of analog beamforming with hardware impairments for mmW massive MIMO communication in an urban scenario

  • Giménez Colás, Sonia
  • Roger Varea, Sandra
  • Baracca, Paolo
  • Braun, Volker
  • Halbauer, Hardy
  • Martín-Sacristán, David|||0000-0002-7781-557X
  • Monserrat del Río, Jose Francisco|||0000-0001-8664-6408
[EN] The use of massive multiple-input multiple-output (MIMO) techniques for communication at millimeter-Wave (mmW) frequency bands has become a key enabler to meet the data rate demands of the upcoming fifth generation (5G) cellular systems. In particular, analog and hybrid beamforming solutions are receiving increasing attention as less expensive and more power efficient alternatives to fully digital precoding schemes. Despite their proven good performance in simple setups, their suitability for realistic cellular systems with many interfering base stations and users is still unclear. Furthermore, the performance of massive MIMO beamforming and precoding methods are in practice also affected by practical limitations and hardware constraints. In this sense, this paper assesses the performance of digital precoding and analog beamforming in an urban cellular system with an accurate mmW channel model under both ideal and realistic assumptions. The results show that analog beamforming can reach the performance of fully digital maximum ratio transmission under line of sight conditions and with a sufficient number of parallel radio-frequency (RF) chains, especially when the practical limitations of outdated channel information and per antenna power constraints are considered. This work also shows the impact of the phase shifter errors and combiner losses introduced by real phase shifter and combiner implementations over analog beamforming, where the former ones have minor impact on the performance, while the latter ones determine the optimum number of RF chains to be used in practice., The research done by P. Baracca, V. Braun, and H. Halbauer leading to these results received funding from the European Commission H2020 programme under grant agreement number 671650 (mmMAGIC project). The work carried out at the Universitat Politècnica de València was supported by the Ministerio de Economia y Competitividad, Spain (TEC2014-60258-C2-1-R) by the European FEDER funds.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

UWB Path Loss Models for Ingestible Devices

  • Pérez-Simbor, Sofia
  • Andreu-Estellés, Carlos
  • Frasson, Matteo
  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
  • Cardona Marcet, Narciso|||0000-0001-5697-1453
[EN] Currently, some medical devices such as the Wireless Capsule Endoscopy (WCE) are used for data transmission from inside to outside the body. Nevertheless, for certain applications such as WCE, the data rates offered by current medical frequency bands can result insufficient. Ultra Wideband (UWB) frequency band has become an interesting solution for this. However, to date, there is not a formal channel path loss model for the UWB frequency band in the gastrointestinal (GI) scenario due to the huge differences between the proposed studies. There are three main methodologies to characterize the propagation channel, software simulations and experimental measurements either in phantom or in in vivo animals. Previous works do not compare all the methodologies or present some disagreements with the literature. In this paper, a dedicated study of the path loss using the three methodologies aforementioned (simulations, phantoms and in vivo measurements) and a comparison with previous researches in the literature is performed. Moreover, numerical values for a path loss model which agrees with the three methodologies and the literature are proposed. This paper aims at being the starting point for a formal path loss model in the UWB frequency band for WBANs in the GI scenario, This work was supported in part by the European Union's H2020-MSCA-ITN Program for the "Wireless In-body Environment Communication" Project under Grant 675353, in part by the Programa de Ayudas de Investigacion y Desarrollo (PAID-01-16) from Universitat Politecnica de Valencia, and in part by the Ministerio de Economia y Competitividad, Spain under Grant TEC2014-60258-C2-1-R through the European FEDER Funds.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Spatial In-Body Channel Characterization Using an Accurate UWB Phantom

  • Andreu Estellés, Carlos
  • Castelló-Palacios, Sergio|||0000-0003-4689-652X
  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
  • Fornés Leal, Alejandro|||0000-0001-5914-6045
  • Vallés Lluch, Ana|||0000-0002-7896-8666
  • Cardona Marcet, Narciso|||0000-0001-5697-1453
Ultra-wideband (UWB) systems have emerged as a possible solution for future wireless in-body communications. However, in-body channel characterization is complex. Animal experimentation is usually restricted. Furthermore, software simulations can be expensive and imply a high computational cost. Synthetic chemical solutions, known as phantoms, can be used to solve this issue. However, achieving a reliable UWB phantom can be challenging since UWB systems use a large bandwidth and the relative permittivity of human tissues are frequency dependent. In this paper, a measurement campaign within 3.1-8.5 GHz using a new UWB phantom is performed. Currently, this phantom achieves the best known approximation to the permittivity of human muscle in the whole UWB band. Measurements were performed in different spatial positions, in order to also investigate the diversity of the in-body channel in the spatial domain. Two experimental in-body to in-body (IB2IB) and in-body to on-body (IB2OB) scenarios are considered. From the measurements, new path loss models are obtained. Besides, the correlation in transmission and reception is computed for both scenarios. Our results show a highly uncorrelated channel in transmission for the IB2IB scenario at all locations. Nevertheless, for the IB2OB scenario, the correlation varies depending on the position of the receiver and transmitter., This work was supported by the Ministerio de Economia y Competitividad, Spain, under Grant TEC2014-60258-C2-1-R and Grant TEC2014-56469-REDT and by the European FEDER Funds.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Experimental Assessment of Time Reversal for In-Body to In-Body UWB Communications

  • Andreu-Estellés, Carlos
  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
  • Castelló-Palacios, Sergio|||0000-0003-4689-652X
  • Cardona Marcet, Narciso|||0000-0001-5697-1453
[EN] The standard of in-body communications is limited to the use of narrowband systems. These systems are far from the high data rate connections achieved by other wireless telecommunication services today in force. The UWB frequency band has been proposed as a possible candidate for future in-body networks. However, the attenuation of body tissues at gigahertz frequencies could be a serious drawback. Experimental measurements for channel modeling are not easy to carry out, while the use of humans is practically forbidden. Sophisticated simulation tools could provide inaccurate results since they are not able to reproduce all the in-body channel conditions. Chemical solutions known as phantoms could provide a fair approximation of body tissues¿ behavior. In this work, the Time Reversal technique is assessed to increase the channel performance of in-body communications. For this task, a large volume of experimental measurements is performed at the low part of UWB spectrum (3.1-5.1 GHz) by using a highly accurate phantom-based measurement setup. This experimental setup emulates an in-body to in-body scenario, where all the nodes are implanted inside the body. Moreover, the in-body channel characteristics such as the path loss, the correlation in transmission and reception, and the reciprocity of the channel are assessed and discussed., This work was supported by the Programa de Ayudas de Investigacion y Desarrollo (PAID-01-16) from Universitat Politecnica de Valencia and by the Ministerio de Economia y Competitividad, Spain (TEC2014-60258-C2-1-R), by the European FEDER funds.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Ultrawideband Technology for Medical In-Body Sensor Networks: An Overview of the Human Body as a Propagation Medium, Phantoms, and Approaches for Propagation Analysis

  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
  • Fornés Leal, Alejandro|||0000-0001-5914-6045
  • Castelló-Palacios, Sergio|||0000-0003-4689-652X
  • Vallés Lluch, Ana|||0000-0002-7896-8666
  • Cardona Marcet, Narciso|||0000-0001-5697-1453
  • Andreu-Estellés, Carlos
  • Pérez-Simbor, Sofia
  • Barbi, Martina
[EN] An in-body sensor network is that in which at least one of the sensors is located inside the human body. Such wireless in-body sensors are used mainly in medical applications, collecting and monitoring important parameters for health and disease treatment. IEEE Standard 802.15.6-2012 for wireless body area networks (WBANs) considers in-body communications in the Medical Implant Communications Service (MICS) band. Nevertheless, high-data-rate communications are not feasible at the MICS band because of its narrow occupied bandwidth. In this framework, ultrawideband (UWB) systems have emerged as a potential solution for in-body highdata-rate communications because of their miniaturization capabilities and low power consumption., This work was supported by the Programa de Ayudas de Investigación y Desarrollo (PAID-01-16) at the Universitat Politècnica de València, Spain; by the Ministerio de Economía y Competitividad, Spain (TEC2014-60258-C2-1-R); and by the European FEDER funds. It was also funded by the European Union’s H2020:MSCA:ITN program for the Wireless In-Body Environ-ment Communication–WiBEC project under grant 675353.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Distributed Hybrid Precoding for Indoor Deployments Using Millimeter Wave Band

  • Giménez Colás, Sonia
  • Roger Varea, Sandra
  • Calabuig Soler, Daniel|||0000-0003-0611-9902
  • Monserrat del Río, Jose Francisco|||0000-0001-8664-6408
  • Cardona Marcet, Narciso|||0000-0001-5697-1453
[EN] DistributedAntenna Systems (DAS) are an alternative of network deployment that allows reducing the distance between transmitter and receiver by distributing the antennas throughout the coverage area. Moreover, the performance of the millimeter wave (mmWave) band can be significantly high within short transmitter-receiver distances. In this paper, the potential benefits of DAS deployments in the mmWave band are studied. To this aim, a distributed hybrid precoding (DHP) solution with remote antenna unit (RAU) selection capabilities is proposed and analyzed in an indoor DAS working in mmWaves and compared to two other indoor deployment strategies: a conventional cellular system with colocated antenna arrays and a small cell deployment. Theresults show that, using DHP, DAS not only brings huge gains to cell-edge users rate but also increases system capacity, becoming the best overall deployment. Further simulations including practical limitations have revealed that DAS using DHP is quite robust to combiner losses, although its performance is significantly degraded by outdated channel reports., This work has been supported by Ministerio de Economia y Competitividad, Spain (BES-2012-055975 and TEC2014-60258-C2-1-R), and by the European FEDER funds.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

UWB RSS-based Localization for Capsule Endoscopy using a Multilayer Phantom and In Vivo Measurements

  • Barbi, Martina
  • Nevárez, Andrea
  • Pons Beltrán, Vicente
  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
  • Cardona Marcet, Narciso|||0000-0001-5697-1453
[EN] In recent years, the localization for capsule endoscopy applications using ultrawideband (UWB) technology has become an attractive field of investigation due to its potential benefits for patients. The literature concerning performance analysis of radio frequency-based localization techniques for in-body applications at UWB frequencies is very limited. Available studies mainly rely on finite-difference time-domain simulations, using digital human models and on experimental measurements by means of homogeneous phantoms. Nevertheless, no realistic analysis based on multilayer phantom measurements or through in vivo experiment has been reported yet. This paper investigates the performance of the received signal strength-based approach for 2-D and 3-D localizations in the UWB frequency band. For 2-D localization, experimental laboratory measurements using a two-layer phantom-based setup have been conducted. For 3-D localization, data from a recently conducted in vivo experiment have been used. Localization accuracy using path loss models, under ideal and non-ideal channel estimation assumptions, is compared. Results show that, under nonideal channel assumption, the relative localization error slightly increases for the 2-D case but not for the in vivo 3-D case. Impact of receivers selection on the localization accuracy has also been investigated for both 2-D and 3-D cases., This work was supported in part by the European Union's H2020 through the MSCA: ITN Program "Wireless in-Body Environment Communication-WiBEC" under Grant 675353, in part by the Programa de Ayudas de Investigacion y Desarrollo, Universitat Politecnica de Valencia under Grant PAID-01-16, and in part by the Ministerio de Economia y Competitividad, Spain, through the European FEDER Funds under Grant TEC2014-60258-C2-1-R.