RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Initial UWB in-body channel characterization using a novel multilayer phantom measurement setup

  • Pérez-Simbor, Sofia
  • Barbi, Martina
  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
  • Castelló-Palacios, Sergio|||0000-0003-4689-652X
  • Cardona Marcet, Narciso|||0000-0001-5697-1453
[EN] Wireless Body Area Networks (WBANs) are a promising technology for medical purposes. Currently the WBAN are classified into: implanted (in-), surface (on-) or outside (off-) body communications regarding the location of the devices with reference to the human body. The Ultra Wide-Band (UWB) frequency band is growing as a band of interest for implanted communications because of its high data rate and low power consumption among other benefits. Software simulations, in-vivo measurements and experimental phantom measurements are common methods to properly characterize the propagation channel. Nevertheless, up to now, experimental phantoms measurements presented in the literature show some inconveniences, i.e., the accuracy of the phantoms compared with the real human tissues or the testbed used for the measurements. This paper aims at overcoming these issues using accurate phantoms designed for the purpose of implanted communications in the UWB frequency band. In addition, a multilayer phantom container was developed. This container has capacity for two different phantoms, emulating a heterogeneous propagation medium for in-body measurements. Moreover, a novel setup was built for in-body phantom measurements. As a result, an experimental path loss model is presented from the measurements obtained with phantoms. Besides, software simulations mimicking the experimental setup are performed in order to validate the previous results obtained, This work was supported by the European Union's H2020:MSCA:ITN program for the "Wireless In-body Environment Communication-WiBEC" project under the grant agreement no. 675353. this work was also funded by the Programa de Ayudas de Investigación y Desarrollo 8PAID-01-16) from Univeristat Politècnica de València and by the Ministerio de Economía y Competitividad, Spain (TEC2014-60258-C2-1-R), by the European FEDER funds.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Localization for capsule endoscopy at UWB frequencies using an experimental multilayer phantom

  • Barbi, Martina
  • Pérez Simbor, Sofía
  • Andreu Estellés, Carlos
  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
  • Cardona Marcet, Narciso|||0000-0001-5697-1453
[EN] Localization inside the human body using ultrawideband (UWB) wireless technology is gaining importance in several medical applications such as capsule endoscopy. Performance analysis of RF based localization techniques are mainly conducted through simulations using numerical human models or through experimental measurements using homogeneous phantoms. One of the most common implemented RF localization approaches uses the received signal strength (RSS). However, to the best of our knowledge, no experimental measurements employing multilayer phantoms are currently available in literature. This paper investigates the performance of RSS-based technique for two-dimensional (2D) localization by employing a two-layer experimental phantom-based setup. Preliminary results on the estimation of the in-body antenna coordinates show that RSS-based method can achieve a location accuracy on average of 0.5-1 cm within a certain range of distances between in-body and on-body antenna., This work was supported by the European Union’s H2020:MSCA:ITN program for the ”Wireless In-body Environment Communication- WiBEC” project under the grant agreement no. 675353. This work was also funded by the Programa de Ayudas de Investigación y Desarrollo (PAID-01-16) from Universitat Politècnica de València and by the Ministerio de Economía y Competitividad, Spain (TEC2014-60258-C2-1-R), by the European FEDER funds.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Experimental Phantom-Based Security Analysis for Next-Generation Leadless Cardiac Pacemakers

  • Awan, Muhammad Faheem
  • Perez-Simbor, Sofia
  • Kansanen, Kimmo
  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
  • Cardona Marcet, Narciso|||0000-0001-5697-1453
[EN] With technological advancement, implanted medical devices can treat a wide range of chronic diseases such as cardiac arrhythmia, deafness, diabetes, etc. Cardiac pacemakers are used to maintain normal heart rhythms. The next generation of these pacemakers is expected to be completely wireless, providing new security threats. Thus, it is critical to secure pacemaker transmissions between legitimate nodes from a third party or an eavesdropper. This work estimates the eavesdropping risk and explores the potential of securing transmissions between leadless capsules inside the heart and the subcutaneous implant under the skin against external eavesdroppers by using physical-layer security methods. In this work, we perform phantom experiments to replicate the dielectric properties of the human heart, blood, and fat for channel modeling between in-body-to-in-body devices and from in-body-to-off-body scenario. These scenarios reflect the channel between legitimate nodes and that between a legitimate node and an eavesdropper. In our case, a legitimate node is a leadless cardiac pacemaker implanted in the right ventricle of a human heart transmitting to a legitimate receiver, which is a subcutaneous implant beneath the collar bone under the skin. In addition, a third party outside the body is trying to eavesdrop the communication. The measurements are performed for ultrawide band (UWB) and industrial, scientific, and medical (ISM) frequency bands. By using these channel models, we analyzed the risk of using the concept of outage probability and determine the eavesdropping range in the case of using UWB and ISM frequency bands. Furthermore, the probability of positive secrecy capacity is also determined, along with outage probability of a secrecy rate, which are the fundamental parameters in depicting the physical-layer security methods. Here, we show that path loss follows a log-normal distribution. In addition, for the ISM frequency band, the probability of successful eavesdropping for a data rate of 600 kbps (Electromyogram (EMG)) is about 97.68% at an eavesdropper distance of 1.3 m and approaches 28.13% at an eavesdropper distance of 4.2 m, whereas for UWB frequency band the eavesdropping risk approaches 0.2847% at an eavesdropper distance of 0.22 m. Furthermore, the probability of positive secrecy capacity is about 44.88% at eavesdropper distance of 0.12 m and approaches approximately 97% at an eavesdropper distance of 0.4 m for ISM frequency band, whereas for UWB, the same statistics are 96.84% at 0.12 m and 100% at 0.4 m. Moreover, the outage probability of secrecy capacity is also determined by using a fixed secrecy rate., This work was supported by the Marie Curie Research Grants Scheme, with project grant no 675353, EU Horizon 2020-WIBEC ITN 00 (Wireless In-Body Environment). Details can be found at a source https://cordis.europa.eu/project/rcn/198286_en.html.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Impact of Receivers Location on the Accuracy of Capsule Endoscope Localization

  • Barbi, Martina
  • Andrea Nevárez
  • Vicente Pons Beltrán
  • Frasson, Matteo
  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
  • Cardona Marcet, Narciso|||0000-0001-5697-1453
[EN] In recent years, localization for capsule endoscopy applications using Ultra-Wideband (UWB) technology has become an attractive field of study due to its potential benefits for patients. Performance analysis of RF-based localization techniques are very limited in literature. Most of the available studies rely on software simulations using digital human models. Nonetheless, no realistic studies based on in-vivo measurements has been reported yet. This paper investigates the performance of RSS-based technique for three-dimensional (3D) localization in the UWB frequency band. Impact of receivers selection as well as of the evaluated path loss model on the localization accuracy is investigated. Results obtained through CST-based simulations and from recently conducted in-vivo measurements are presented and compared., This work was supported by the European Union's H2020:MSCA:ITN program for the "Wireless In-body Environment Communication- WiBEC" project under the grant agreement no. 675353. This work was also funded by the Ministerio de Economia y Competitividad, Spain (TEC2014-60258-C2-1-R), by the European FEDER funds.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Capítulo o parte de un libro (BookPart)

Initial Delay Domain UWB Channel Characterization for In-body Area Networks

  • Pérez-Simbor, Sofia
  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
  • Cardona Marcet, Narciso|||0000-0001-5697-1453
Wireless Body Area Networks (WBANs) have increased the attention of the research community for the next generation wireless medical devices. Among others, Wireless Capsule Endoscopy (WCE) aims to transmit better quality images. For this, the Ultra Wideband (UWB) frequency band is becoming a good alternative to currently allocated frequencies for in-body networks, allowing higher data rate and having a low power transmission. Common channel characterization in WBANs are performed in frequency domain, i.e., analyzing the received power as a function of frequency. Nevertheless, indepth studies in delay domain analyzing the impulse response of the channel are barely considered in current literature. In this paper, an initial study in delay domain, i.e., the Power Delay Profile (PDP) characteristics, is performed. Moreover, a comparison between the channel response in frequency and delay domain is performed. This work gives an insightful view of the impulse response of the channel for in-body to on-body communications. For that, an extensive campaign of phantom measurements and software simulations are conducted., This work was supported by the European Union’s H2020:MSCA:ITN program for the ”Wireless In-body Environment Communication- WiBEC” project under the grant agreement no. 675353. This work was also funded by by the European Union’s H2020: MSCA: ITN program for the ”mmWave Communications in the Built Environments - WaveComBE” project under the grant agreement no. 766231.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Capítulo o parte de un libro (BookPart)

Automatic Detection of Intestinal Content to Evaluate Visibility in Capsule Endoscopy

  • Noorda, Reinier
  • Nevárez, Andrea
  • Colomer, Adrián
  • Naranjo, Valery
  • Pons Beltrán, Vicente
In capsule endoscopy (CE), preparation of the small bowel before the procedure is believed to increase visibility of the mucosa for analysis. However, there is no consensus on the best method of preparation, while comparison is difficult due to the absence of an objective automated evaluation method. The method presented here aims to fill this gap by automatically detecting regions in frames of CE videos where the mucosa is covered by bile, bubbles and remainders of food. We implemented two different machine learning techniques for supervised classification of patches: one based on hand-crafted feature extraction and Support Vector Machine classification and the other based on fine-tuning different convolutional neural network (CNN) architectures, concretely VGG-16 and VGG-19. Using a data set of approximately 40,000 image patches obtained from 35 different patients, our best model achieved an average detection accuracy of 95.15% on our test patches, which is similar to significantly more complex detection methods used for similar purposes. We then estimate the probabilities at a pixel level by interpolating the patch probabilities and extract statistics from these, both on per-frame and per-video basis, intended for comparison of different videos., This work was funded by the European Union’s H2020: MSCA: ITN program for the “Wireless In-body Environment Communication – WiBEC” project under the grant agreement no. 675353.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Capítulo o parte de un libro (BookPart)

Analysis of the Localization Error for Capsule Endoscopy Applications at UWB Frequencies

  • Barbi, Martina
  • Pérez-Simbor, Sofia
  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
  • Cardona Marcet, Narciso|||0000-0001-5697-1453
Localization for Wireless Capsule Endoscopy (WCE) in the Ultra-Wideband frequency band is a very active field of investigation due to its potential advantages in future endoscopy applications. Received Signal Strength (RSS) based localization is commonly preferred due to its simplicity. Previous studies on Ultra-Wideband (UWB) RSS-based localization showed that the localization accuracy depends on the average ranging error related to the selected combination of receivers, which not always is the one experiencing the highest level of received power. In this paper the tendency of the localization error is further investigated through supplementary software simulations and previously conducted laboratory measurements. Two-dimensional (2D) and three-dimensional (3D) positioning are performed and the trend of the localization error compared in both cases. Results shows that the distribution of the selected path loss values, corresponding to the receivers used for localization, around the in-body position to estimate also affects the localization accuracy., This work was supported by the H2020:MSCA:ITN program for the “Wireless In-body Environment Communication- WiBEC” project under the grant agreement no. 675353. This work was also supported by the European Union’s H2020:MSCA:ITN program for the ”mmWave Communications in the Built Environments - WaveComBE” project under the grant agreement no. 766231.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

UWB Path Loss Models for Ingestible Devices

  • Pérez-Simbor, Sofia
  • Andreu-Estellés, Carlos
  • Frasson, Matteo
  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
  • Cardona Marcet, Narciso|||0000-0001-5697-1453
[EN] Currently, some medical devices such as the Wireless Capsule Endoscopy (WCE) are used for data transmission from inside to outside the body. Nevertheless, for certain applications such as WCE, the data rates offered by current medical frequency bands can result insufficient. Ultra Wideband (UWB) frequency band has become an interesting solution for this. However, to date, there is not a formal channel path loss model for the UWB frequency band in the gastrointestinal (GI) scenario due to the huge differences between the proposed studies. There are three main methodologies to characterize the propagation channel, software simulations and experimental measurements either in phantom or in in vivo animals. Previous works do not compare all the methodologies or present some disagreements with the literature. In this paper, a dedicated study of the path loss using the three methodologies aforementioned (simulations, phantoms and in vivo measurements) and a comparison with previous researches in the literature is performed. Moreover, numerical values for a path loss model which agrees with the three methodologies and the literature are proposed. This paper aims at being the starting point for a formal path loss model in the UWB frequency band for WBANs in the GI scenario, This work was supported in part by the European Union's H2020-MSCA-ITN Program for the "Wireless In-body Environment Communication" Project under Grant 675353, in part by the Programa de Ayudas de Investigacion y Desarrollo (PAID-01-16) from Universitat Politecnica de Valencia, and in part by the Ministerio de Economia y Competitividad, Spain under Grant TEC2014-60258-C2-1-R through the European FEDER Funds.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Automatic evaluation of degree of cleanliness in capsule endoscopy based on a novel CNN architecture

  • Noorda, Reinier
  • Nevárez, Andrea
  • Pons Beltrán, Vicente
  • Colomer, Adrián|||0000-0002-7616-6029
  • Naranjo Ornedo, Valeriana|||0000-0002-0181-3412
[EN] Capsule endoscopy (CE) is a widely used, minimally invasive alternative to traditional endoscopy that allows visualisation of the entire small intestine. Patient preparation can help to obtain a cleaner intestine and thus better visibility in the resulting videos. However, studies on the most effective preparation method are conflicting due to the absence of objective, automatic cleanliness evaluation methods. In this work, we aim to provide such a method capable of presenting results on an intuitive scale, with a relatively light-weight novel convolutional neural network architecture at its core. We trained our model using 5-fold cross-validation on an extensive data set of over 50,000 image patches, collected from 35 different CE procedures, and compared it with state-of-the-art classification methods. From the patch classification results, we developed a method to automatically estimate pixel-level probabilities and deduce cleanliness evaluation scores through automatically learnt thresholds. We then validated our method in a clinical setting on 30 newly collected CE videos, comparing the resulting scores to those independently assigned by human specialists. We obtained the highest classification accuracy for the proposed method (95.23%), with significantly lower average prediction times than for the second-best method. In the validation of our method, we found acceptable agreement with two human specialists compared to interhuman agreement, showing its validity as an objective evaluation method., This work was funded by the European Union's H2020: MSCA: ITN program for the "Wireless In-body Environment Communication - WiBEC" project under the grant agreement no. 675353. Additionally, we gratefully acknowledge the support of NVIDIA Corporation with the donation of the Titan V GPU used for this research. Figures 2 and 3 were drawn by the authors.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Ultrawideband Technology for Medical In-Body Sensor Networks: An Overview of the Human Body as a Propagation Medium, Phantoms, and Approaches for Propagation Analysis

  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
  • Fornés Leal, Alejandro|||0000-0001-5914-6045
  • Castelló-Palacios, Sergio|||0000-0003-4689-652X
  • Vallés Lluch, Ana|||0000-0002-7896-8666
  • Cardona Marcet, Narciso|||0000-0001-5697-1453
  • Andreu-Estellés, Carlos
  • Pérez-Simbor, Sofia
  • Barbi, Martina
[EN] An in-body sensor network is that in which at least one of the sensors is located inside the human body. Such wireless in-body sensors are used mainly in medical applications, collecting and monitoring important parameters for health and disease treatment. IEEE Standard 802.15.6-2012 for wireless body area networks (WBANs) considers in-body communications in the Medical Implant Communications Service (MICS) band. Nevertheless, high-data-rate communications are not feasible at the MICS band because of its narrow occupied bandwidth. In this framework, ultrawideband (UWB) systems have emerged as a potential solution for in-body highdata-rate communications because of their miniaturization capabilities and low power consumption., This work was supported by the Programa de Ayudas de Investigación y Desarrollo (PAID-01-16) at the Universitat Politècnica de València, Spain; by the Ministerio de Economía y Competitividad, Spain (TEC2014-60258-C2-1-R); and by the European FEDER funds. It was also funded by the European Union’s H2020:MSCA:ITN program for the Wireless In-Body Environ-ment Communication–WiBEC project under grant 675353.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Dielectric Characterization of In Vivo Abdominal and Thoracic Tissues in the 0.5 26.5 GHz Frequency Band for Wireless Body Area Networks

  • Fornés Leal, Alejandro|||0000-0001-5914-6045
  • Cardona Marcet, Narciso|||0000-0001-5697-1453
  • Castelló-Palacios, Sergio|||0000-0003-4689-652X
  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
  • Frasson, Matteo
  • Nevárez, Andrea
  • PONS BELTRÁN, VICENTE
[EN] The dielectric properties of biological tissues are of utmost importance in the development of wireless body area networks (WBANs), especially for implanted devices. The early design stages of medical devices like capsule endoscopy, pacemakers, or physiological sensors rely on precise knowledge of the dielectric properties of the tissues present in their surrounding medium. Many of these applications make use of electromagnetic phantoms, which are software or physical models that imitate the shape and the electromagnetic properties of the tissues. They are used for designing devices in software simulations and for testing them in laboratory trials, aiding in both the development of WBAN antennas or in communication link evaluations. The existing reports about dielectric in vivo properties are limited and have drawbacks like: low variety of characterized tissues, lacking some relevant ones, and limitations and inhomogeneity in the measured frequency range. This paper aims at filling that gap by providing a new database of dielectric properties of biological tissues measured in vivo . In particular, it is focused on the tissues of the thoracic and the abdominal regions, measured at the same wide frequency band, on the same animal specimen, and under the same conditions. The properties have been obtained by measuring porcine tissues in the 0.5¿26.5 GHz band with the open-ended coaxial technique. In this paper, we focus on those tissues that have been scarcely characterized so far in the literature, like heart, esophagus, stomach, and pancreas. The Cole¿Cole fitting parameters of the measured tissues and their uncertainties are provided., This work was supported in part by UPV-IIS LaFe Program (STuDER, 2016, and EMOTE, 2018), in part by the Programa de Ayudas de Investigacion y Desarrollo (PAID-01-16) from the Universitat Politecnica de Valencia, in part by the European Union's H2020: MSCA: ITN Programs for the "Wireless In-Body Environment Communication-WiBEC'' Project, under Grant 675353, and in part by the "mmWave Communications in the Built Environments-WaveComBE'' Project, under Grant 766231.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

UWB RSS-based Localization for Capsule Endoscopy using a Multilayer Phantom and In Vivo Measurements

  • Barbi, Martina
  • Nevárez, Andrea
  • Pons Beltrán, Vicente
  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
  • Cardona Marcet, Narciso|||0000-0001-5697-1453
[EN] In recent years, the localization for capsule endoscopy applications using ultrawideband (UWB) technology has become an attractive field of investigation due to its potential benefits for patients. The literature concerning performance analysis of radio frequency-based localization techniques for in-body applications at UWB frequencies is very limited. Available studies mainly rely on finite-difference time-domain simulations, using digital human models and on experimental measurements by means of homogeneous phantoms. Nevertheless, no realistic analysis based on multilayer phantom measurements or through in vivo experiment has been reported yet. This paper investigates the performance of the received signal strength-based approach for 2-D and 3-D localizations in the UWB frequency band. For 2-D localization, experimental laboratory measurements using a two-layer phantom-based setup have been conducted. For 3-D localization, data from a recently conducted in vivo experiment have been used. Localization accuracy using path loss models, under ideal and non-ideal channel estimation assumptions, is compared. Results show that, under nonideal channel assumption, the relative localization error slightly increases for the 2-D case but not for the in vivo 3-D case. Impact of receivers selection on the localization accuracy has also been investigated for both 2-D and 3-D cases., This work was supported in part by the European Union's H2020 through the MSCA: ITN Program "Wireless in-Body Environment Communication-WiBEC" under Grant 675353, in part by the Programa de Ayudas de Investigacion y Desarrollo, Universitat Politecnica de Valencia under Grant PAID-01-16, and in part by the Ministerio de Economia y Competitividad, Spain, through the European FEDER Funds under Grant TEC2014-60258-C2-1-R.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Capítulo o parte de un libro (BookPart)

Design and Development of an Automatic Blood Detection System for Capsule Endoscopy Images

  • Pons Suñer, Pedro
  • Noorda, Reinier
  • Nevárez, Andrea
  • Colomer, Adrián
  • Pons Beltrán, Vicente
  • Naranjo, Valery
Wireless Capsule Endoscopy is a technique that allows for observation of the entire gastrointestinal tract in an easy and non-invasive way. However, its greatest limitation lies in the time required to analyze the large number of images generated in each examination for diagnosis, which is about 2 hours. This causes not only a high cost, but also a high probability of a wrong diagnosis due to the physician’s fatigue, while the variable appearance of abnormalities requires continuous concentration. In this work, we designed and developed a system capable of automatically detecting blood based on classification of extracted regions, following two different classification approaches. The first method consisted in extraction of hand-crafted features that were used to train machine learning algorithms, specifically Support Vector Machines and Random Forest, to create models for classifying images as healthy tissue or blood. The second method consisted in applying deep learning techniques, concretely convolutional neural networks, capable of extracting the relevant features of the image by themselves. The best results (95.7% sensitivity and 92.3% specificity) were obtained for a Random Forest model trained with features extracted from the histograms of the three HSV color space channels. For both methods we extracted square patches of several sizes using a sliding window, while for the first approach we also implemented the waterpixels technique in order to improve the classification results, This work was funded by the European Unions H2020: MSCA: ITN program for the “Wireless In-body Environment Communication WiBEC” project under the grant agreement no. 675353. Additionally, we gratefully acknowledge the support of NVIDIA Corporation with the donation of the Titan V GPU used for this research.