Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 17
Encontrada(s) 1 página(s)

Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

50-km remote electronic-sensor integration in fiber optic networks using power over fiber and microelectromechanical modulators

  • Rodríguez Rodríguez, Armando
  • López-Amo Sáinz, Manuel
  • Bravo Acha, Mikel
This work presents a power-efficient solution that combines and enables the use of electronic devices in fiber optic networks for environmental monitoring. The system is based on a frequency encoding scheme of the sensor data, which modulates the optical carrier via a microelectromechanical (MEMS) variable optical attenuator (VOA). We demonstrate a remote battery-less sensor node, powered exclusively by power-over-fiber (PoF), over a 50-km standard telecom link, using energy harvesting techniques. As a proof-of-concept, a low-power microcontroller encodes the data from electronic sensors of temperature, eCO2, and pressure in a frequency pattern, which are used as modulating signals. A Frequency Shift Keying (FSK) modulation was implemented, resulting in data rates of up to 1.5 kbps at the maximum corner frequency value of the modulator. The retrieved and decoded data were transmitted via a second optical fiber segment, extending 50 km., This work was supported in part by projects PID2022-137269OB-C21, funded by MCIN/AEI/10.13039/501100011033 and FEDER \u201CA way to make Europe\u201D, and TED2021-130378B-C22, funded by MCIN/AEI/10.13039/501100011033 and European Union \u201CNext generation EU\u201D/PRTR. and the Beatriz Galindo BEAGAL18/00116 grant funded by MICINN.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Optical fiber sensor for water velocity measurement in rivers and channels

  • Rodríguez Rodríguez, Armando
  • Diéguez Elizondo, Pedro
  • Urroz Unzueta, José Carlos
  • Bravo Acha, Mikel
  • López Rodríguez, José Javier
  • López-Amo Sáinz, Manuel
In this work, optical fiber Bragg grating sensors were used to measure water velocity and examine how it was distributed in open channels. Several types of coatings were incorporated into the design of the sensors to examine their effects on the strain that the fibers experienced as a result of the water flow. Due to their low elastic coefficient, which reduced the hysteresis, the results indicated that the aluminum- and acrylate-coated fibers had the best performance. ANSYS-CFX V2020 R2 software was used to model the strain encountered by the fibers under various flow rates to assess the performance of the FBG sensors. The calculations and actual data exhibited good convergence, demonstrating the accuracy of the FBG sensors in determining water velocity. The study illustrated the usability of the proposal in both scenarios by contrasting its application in rivers and channels., This work was supported in part by projects PID2022-137269OB-C21, funded by MCIN/AEI/https://doi.org/10.13039/501100011033 and FEDER 'A way to make Europe', and TED2021-130378B-C22 funded by MCIN/AEI/https://doi.org/10.13039/501100011033 and European Union 'Next generation EU'/PTR
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

High resolution liquid level measurement using a multisection interferometer based on capillary fibers

  • Vanegas Tenezaca, Evelyn Dayanara
  • Galarza Galarza, Marko
  • Dauliat, Romain
  • Jamier, Raphael
  • Roy, Philippe
  • López-Amo Sáinz, Manuel
This paper presents a novel capillary structure for liquid level measurement. The multifiber interferometric structure, which employs two capillary sections, is well-suited to the measurement of liquid levels in both short distances and with high resolution. The measurement range extends up to 60 mm with a resolution of 0.70 mm., This work was supported in part by the MCIN/AEI/10.13039/501100011033 and FEDER "A way to make Europe" under Grant PID2022-137269OB-C21 and in part by the MCIN/AEI/10.13039/501100011033 and European Union "Next generation EU"/PRTR under Grant TED2021-130378B-C22. Open access funding provided by Universidad Pública de Navarra.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Multidirectional bending sensor using capillary fibers and machine learning for real-time applications

  • Vanegas Tenezaca, Evelyn Dayanara
  • Galarza Galarza, Marko
  • Dauliat, Romain
  • Jamier, Raphael
  • Roy, Philippe
  • López-Amo Sáinz, Manuel
In this article, the design and implementation of a bidirectional curvature sensor based on a fiber-optic interferometer are presented. The sensor structure was fabricated by fusing a capillary fiber fragment between single-mode fibers (SMFs), with the addition of a long end capillary to promote a long interferometric section, forming a Fabry-Perot (FP) cavity. Detailed analysis of the curvature data was carried out using machine learning techniques, allowing accurate classification of curvature in both directions of rotation. The experimental results showed excellent agreement (R2: 0.9998) with the predicted values. The sensor exhibits a maximum error of 1.9485°. This approach presents significant potential for applications requiring accurate real-time curvature measurements., This work was supported in part by CIN/AEI/10.13039/501100011033 and FEDER "AWay to Make Europe" under Project PID2022-137269OB and in part by MCIN/AEI/10.13039/501100011033 and European Union "Next Generation EU"/PRTR under Project TED2021-130378B. Open access funding provided by Universidad Publica de Navarra.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Low-cost system for vital signs monitoring based on long-period fiber grating

  • Molinos Rodríguez, Ariana
  • Martínez Ortiz, Francisco
  • Erro Betrán, María José
  • Tainta Ausejo, Santiago
  • Pérez Herrera, Rosa Ana
Accurate and continuous respiratory and heart rate monitoring is essential during medical procedures to ensure patient safety. This work explores the feasibility of using LPGs for monitoring in clinical environments where immunity to electromagnetic interference is crucial. Preliminary analysis and results suggest the validity of the proposal. Future research will focus on experimental validation and signal processing techniques to enhance performance., This research was supported by the Public University of Navarre Collaboration grants. This work was supported in part by projects PID2022-137269OB, funded by CIN/AEI/10.13039/501100011033 and FEDER ¿A way to make Europe¿, and TED2021-130378B funded by MCIN/AEI/10.13039/501100011033 and European Union "Next generation EU"/PRTR.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Optical test set for microwave vector network analyzers based on homodyne detection

  • Vallifuoco, Raffaele
  • Sagüés García, Mikel
  • Zeni, Luigi
  • Minardo, Aldo
  • Loayssa Lara, Alayn
We present an optical test set for a microwave vector network analyzer that transforms the instrument into a full vector optical analyzer (OVA), enabling measurements of the optical field transfer function of components and systems with Hz-level frequency resolution. The setup is simple, consisting of a laser source, a standard Mach-Zehnder electro-optic modulator, and a self-homodyne receiver based on a 90° optical hybrid and balanced detectors. Unlike other OVA methods that use RF-modulated optical signals, our technique avoids complex setups and multi-step procedures. It is also immune to errors caused by beating between unwanted modulation sidebands. We provide a detailed theoretical derivation of the mathematical framework underlying the method. In addition, we introduce a calibration technique that compensates for all optical and electrical non-idealities in the setup, including those introduced by the optical hybrid. We demonstrate the system's operation through proof-of-concept experiments, measuring both the magnitude and phase of the optical field transfer function of narrowband optical components., This work was supported in part by MCIN/AEI/10.13039/501100011033 under Grant PID2022-137269OB-C21, in part by ERDF ¿A way to make Europe¿, in part by MCIN/AEI/10.13039/501100011033 under Grant TED2021-130378B-C22, in part by European Union "Next generationEU"/PRTR, and in part by Universidad Pública de Navarra.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Optical fiber pH sensors based on PAni-coated microstructured optical fibers

  • Rodríguez Rodríguez, Armando
  • Lopes, Guilherme
  • Nedoma, Jan
  • Pereira, Sónia O.
  • Fernandes, Antonio J. S.
  • Jamier, Raphael
  • Roy, Philippe
  • Bravo Acha, Mikel
  • López-Amo Sáinz, Manuel
  • Marques, Carlos
In this article, we report the analysis of a novel optical fiber pH sensor based in polyaniline (PAni) coating applied on a trenched core-free (only-bridge) silica fiber. The results are compared to another pH sensor based on side-polished silica fiber. The pH-sensitive polymer is synthesized over the fiber sample by means of oxidative polymerization, keeping records of the time where the reaction occurs to improve the sensitivity. The response to pH is enhanced in the case of the trenched core-free bridge fiber due to the higher interaction of the evanescent field with the PAni film and, thus, the surrounding media. The sensitivity in the linear zone of operation is 1.1 mW/pH, and a total transmittance of 55% in the pH range is 4.2-8.1. The repeatability of both sensors was checked, showing a high capability to perform studies in liquid samples due to its temperature independence, good sensitivity, and long-term stability., This work was supported in part by MCIN/AEI/10.13039/501100011033 under Project PID2022-137269OBC21 and Project TED2021-130378B-C22; in part by the Fondo Europeo de Desarrollo Regional (FEDER) “A way to make Europe;” in part by the European Union “Next Generation EU”/PRTR; in part by Beatriz Galindo in MICINN under Grant BEAGAL18/00116; in part by the CICECO–Aveiro Institute of Materials under Project LA/P/0006/2020, Project UIDB/50011/2020, and Project UIDP/50011/2020; in part by i3N under Project UIDB/50025/2020, Project UIDP/50025/2020, and Project LA/P/0037/2020; in part by DigiAqua under Project PTDC/EEIEEE/0415/2021; in part by the National Funds through the Portuguese Science and Technology Foundation/MCTES (FCT I.P., Portugal); in part by the European Union through the Research Excellence For Region Sustainability and High-Tech Industries (REFRESH) under Project CZ.10.03.01/00/22_003/0000048 via the Operational Program Just Transition; and in part by the Ministry of Education, Youth, and Sports of the Czech Republic through the VSB–Technical University of Ostrava under Grant SP2024/081 and Grant SP2024/059. Open access funding provided by Universidad Pública de Navarra.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Design of optical fiber Bragg grating-based sensors for flow measurement in pipes

  • Diéguez Elizondo, Pedro
  • Rodríguez Rodríguez, Armando
  • Urroz Unzueta, José Carlos
  • López Rodríguez, José Javier
  • López-Amo Sáinz, Manuel
In this work, optical Fiber Bragg grating (FBG) sensors were used to measure water flow in pipes. Several types of coatings were incorporated into the design of the sensors to examine their effects on the elastic strain that the fiber underwent as a result of the water flow. ANSYS-CFX V2020 R2 software was used to model the elastic strain encountered by the fiber under various flow rates in order to assess the performance of the FBG sensors. The calculations and experimental data exhibited good convergence, demonstrating the accuracy of the FBG sensors in determining water flow. These calculations and procedures can be extrapolated to any other fluid., This work was supported in part by projects PID2019-107270RB-C02, funded by MCIN/AEI/10.13039/501100011033 and FEDER “A way to make Europe”, and TED2021-130378B-C22 funded by MCIN/AEI/10.13039/501100011033 and European Union “Next generation EU”/PTR.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Ring cavity erbium-doped fiber for refractive index measurements

  • Pérez Herrera, Rosa Ana
  • Soares, Liliana
  • Silva, Susana
  • Frazão, Orlando
In this study, an interrogation system based on an erbium-doped fiber ring cavity for refractive index measurements is presented and experimentally demonstrated. This cavity ring includes a 1 × 3 coupler wherein one of the fiber output ports is used to increase the optical power of the system by means of an FBG used as a reflector. The other two output ports are used as a refractive index sensing head and reference port, respectively. An experimental demonstration of this proposed sensor system for the measurement of a distinct refractive index is presented., This work is financed by the program “José Castillejo para estancias de movilidad en el extranjero de jóvenes doctores”, funded by the Ministerio de Universidades of Spain (reference CAS21/00351); project PID2019-107270RB-C22, funded by MCIN/AEI/10.13039/501100011033 and FEDER “A way to make Europe”; projects PDC2021-121172-C21 and TED2021-130378B-C22 funded by MCIN/AEI/10.13039/501100011033 and European Union “Next generation EU”/PTR; and National Funds through the Portuguese funding agency, FCT—Fundação para a Ciência e a Tecnologia, within project UIDB/50014/2020. Liliana Soares acknowledges the support of FCT, Portugal through the Grant 2020.05297.BD.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

High frequency vibration sensor using a fiber laser with a multicore fiber interferometer

  • Correa Serrano, Ángel Ignacio
  • Galarza Galarza, Marko
  • Dauliat, Romain
  • Jamier, Raphael
  • Roy, Philippe
  • López-Amo Sáinz, Manuel
  • Pérez Herrera, Rosa Ana
We present an interferometric vibration sensor that uses three-core fibers. The transducer is constructed by splicing a segment 20 mm long of a multicore optical fiber (MCF) to a single-mode optical fiber (SMF). The end of the MCF segment is cut off and painted using silver metallic paint. The sensor head is operated in reflection mode. The structure is placed on a polyvinyl chloride (PVC) plate, which is excited with a wide range of frequency signals. The vibrations induce cyclic bending in the MCF segment, resulting in periodic oscillations of the reflected interference spectrum. This device is demonstrated to be suitable to measure vibrations in a frequency range of the order of 300 kHz detecting deformations as small as 0.40μm ., This work was supported in part by projects PID2019-107270RB-C02 and PID2022- 137269OB-C21, funded by MCIN/AEI/10.13039/501100011033 and FEDER “A way to make Europe,” and TED2021-130378B-C22 funded by MCIN/AEI/10.13039/501100011033 and European Union “Next generation EU”/PRTR.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Study of in-line capillary fiber sensor for uniaxial transverse deformation

  • Sánchez González, Arturo
  • Leandro González, Daniel
  • Dauliat, Romain
  • Jamier, Raphael
  • Roy, Philippe
  • Pérez Herrera, Rosa Ana
This research explores the impact of cyclic uniaxial transverse deformation on an in-line hollow-core fiber etalon. The structure consists of a 6 mm long section of capillary fiber spliced between two standard single-mode fibers. The optical response of the structure is theoretically analyzed in spectral and transformed domains, evidencing Fabry-Perot and antiresonant interferometric mechanisms. A validation of the theoretical behavior is carried out both through simulation and experimentation. The performance of the structure for uniaxial transverse deformation is subsequently evaluated by tracking the phase of the main component in the transformed domain. The relevance of measuring in the time domain is discussed, demonstrating improved accuracy over wavelength shift and inverse spatial domain methods. Several sensors with different internal diameters underwent cycles of transverse deformation, revealing robust linear trends in every case. On average, the structure demonstrated elastic behavior under deformations up to 42 μm, with a mean sensitivity of 0.174 rad/μm, and mechanical breakage taking place at 58 μm. The results confirmed the suitability of the sensor to withstand uniaxial micro-displacements or pressures, with smaller inner diameter capillary fibers showing the best performance., This work was supported in part by MCIN/AEI/10.13039/501100011033 and FEDER "A way to make Europe" under Project PID2019-107270RB-C22 and Project PID2022-137269OB-C21, in part by MCIN/AEI/10.13039/501100011033 and European Union "Next generation EU"/PRTR under Project PDC2021-121172-C21 and Project TED2021- 130378B-C22, and in part by the Public University of Navarre under Project PJUPNA06-2022. Open access funding provided by Public University of Navarre.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Power over fiber system for heterogeneous sensors multiplexing

  • Rodríguez Rodríguez, Armando
  • Vanegas Tenezaca, Evelyn Dayanara
  • Vento Álvarez, José Raúl
  • López-Amo Sáinz, Manuel
  • Bravo Acha, Mikel
This paper presents a Power-over-Fiber based remote electronic and optical fiber sensors multiplexing scheme. The system architecture consists of a 50-km linear cavity Raman-fiber laser that is used for interrogation of FBG optical fiber sensors. Simultaneously, electronic sensors information is modulated in amplitude while the optical sensors' data are encoded in the spectral information. In order to bias the electronic sensors, the residual power of the Raman pump laser is collected in an energy harvesting unit. This electric power is used for biasing an ATTiny85 control unit and two electro-optical modulators. A proof-of-concept is presented where a couple of optical fiber-Bragg-gratings sensors collect strain information that is self-compensated in temperature according to the digital data achieved from the electronic sensors. A 9.6 kbit/s data rate was achieved using Mach-Zehnder amplitude modulators and a maximum 35 ksample/s was retrieved using a high-speed C-band spectrometer and performing spectral analysis via a software developed in Python. Authors, This work was supported in part by MCIN/AEI/10.13039/501100011033 and FEDER "A way to make Europe", under Project PID2022-137269OB-C21, in part by MCIN/AEI/10.13039/501100011033 and European Union "Next generation EU"/PRTR under Project TED2021-130378B-C22, and in part by MICINN under the Beatriz Galindo BEAGAL18/00116 Grant. Open access funding provided by Universidad Publica de Navarra.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Paracetamol concentration-sensing scheme based on a linear cavity fiber laser configuration

  • Soares, Liliana
  • Pérez Herrera, Rosa Ana
  • Novais, Susana
  • Ferreira, António
  • Frazão, Orlando
  • Silva, Susana
A paracetamol concentration-sensing scheme based on a linear cavity fiber laser configuration is demonstrated experimentally. The laser cavity has a fiber sensor at one end, that allows refractive index measurements. The refractometer consists of a cleaved fiber tip combined with an FBG functioning as a reflecting mirror. The combination of a fiber loop mirror at the other end allows to reflect all the light from the FBG and refractometer, forming a linear cavity. By measuring the intensity variation of the Fresnel reflection at the fiber-to-liquid interface, the measured concentration is linear and have a concentration sensitivity of -8.74±0.34×10-5 µW/(g/kg), over a range of 52.61 to 219.25 g/kg, and with a resolution of 2.77 g/kg. The results obtained present high stability and prove the potential of the fiber laser system to performed real-time measurements of concentration, in a non-invasive way., This research was funded by: National Funds through the Portuguese funding agency, FCT - Fundação para a Ciência e a Tecnologia, within project UIDB/50014/2020; National Funds through FCT/MCTES (PIDDAC), within projects LA/P/0045/2020 (ALiCE), UIDB/00511/2020 and UIDP/00511/2020 (LEPABE); Program “José Castillejo para estancias de movilidad en el extranjero de jóvenes doctores”, funded by the Ministerio de Univesidades of Spain (reference CAS21/00351); project PID2019-107270RB-C22, funded by MCIN/AEI/https://doi.org/10.13039/501100011033 and FEDER “A way to make Europe”; projects PDC2021-121172-C21 and TED2021-130378B-C22 funded by MCIN/ AEI/https://doi.org/10.13039/501100011033 and European Union “Next generation EU”/PTR. Liliana Soares acknowledges the support of FCT, Portugal, through the Grant 2020.05297.BD.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Urban water leakage detection system over dark fiber networks based on distributed acoustic sensing and sparse autoencoders

  • Sharif, Vahid
  • Yao, Yuanyuan
  • Loayssa Lara, Alayn
  • Sagüés García, Mikel
We propose and experimentally validate an automatic urban water leakage detection architecture that leverages dark fiber links already deployed in telecommunication networks in underground conduits in the vicinity of water pipelines. The sensing stage relies on a differential-phase coherent optical time-domain reflectometry interrogator enhanced with optical pulse compression to improve sensitivity. Building on this vibration acquisition stage, automatic leakage detection algorithms are implemented by searching for leak-induced activity in the frequency domain, which is well suited to revealing leakage-related features. After acquiring a baseline calibration to characterize normal-condition vibrations at each sensing position, leakage candidates are identified by comparing distribution-based metrics computed over multiple measurements against the corresponding baseline statistics. Two automatic leakage detection strategies are developed. First, low-complexity feature-based metrics are implemented, enabling continuous monitoring with minimal computational requirements. Second, an autoencoder-based anomaly detection technique is introduced, which also relies on location-specific normal-condition calibration but reduces the dependence on prior knowledge of the expected leakage vibration signatures. A real-world field trial on an urban network demonstrates reliable detection and localization using controlled leak events generated in the field, with measurements performed over a 17 km sensing fiber and an effective spatial resolution of 2.6 m. Benchmarking against a commercial punctual electro-acoustic leak detector yields consistent trends. Overall, the proposed system could complement existing technologies by enabling automated, continuous city-scale monitoring over already deployed dark fiber infrastructure., This work was supported in part by grant PID2022-137269OB-C21 funded by MCIN/AEI/10.13039/501100011033, ERDF “A way to make Europe”, and by grant TED2021-130378B-C22 funded by MCIN/AEI/10.13039/501100011033 and European Union “Next generationEU”/PRTR, and the China Scholarship Council (CSC). Open accessfunding was provided by Universidad Pública de Navarra.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

General method for Rayleigh signature interrogation in distributed acoustic sensors based on optical time-domain reflectometry

  • Sharif, Vahid
  • Sagüés García, Mikel
  • Loayssa Lara, Alayn
We introduce a method to measure the Rayleigh signature of an optical fiber, which is defined as the frequency dependence of the backscattering from each position along its length. The method uses the Short-Frequency Fourier transform to extract frequency-dependent time-resolved information from the spectrum of the detected pulse response in an optical time-domain reflectometry (OTDR) setup. The Rayleigh signature obtained can be used to implement broadband high-sensitivity high-linearity distributed acoustic sensors (DAS) that are immune to signal fading problems commonly affecting other OTDR-based systems. Rayleigh signature interrogation has been widely applied in optical frequency-domain reflectometry sensors and some specialized OTDR configurations. However, to our knowledge, this is the first technique that enables its general use in conventional single-pulse coherent OTDR setups, as well as in other time-domain systems that measure the impulse response of a fiber, such as those that utilize pulse compression. We experimentally demonstrate the method in a conventional heterodyne-detection OTDR DAS and also in a enhanced-performance pulse compression setup employing phasecoded waveforms. Measurements in a 50 km fiber with spatial resolution 2 m and a sensitivity of 113 p/√Hz demonstrate the capabilities of the technique., publication 15 July 2025; date of current version 16 September 2025. This work was supported in part by Grant PID2022-137269OBC21 funded by MCIN/AEI/10.13039/501100011033 and by ERDF “A way to make Europe”, in part by Grant TED2021-130378B-C22 funded by MCIN/AEI/10.13039/501100011033 and European Union “Next generationEU”/PRTR. Open access funding provided by Universidad Pública de Navarra.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Quasi-distributed 3-cm vibration and strain monitoring using OFDR and in-line interferometers

  • Sánchez González, Arturo
  • Leandro González, Daniel
  • Shi, Muyu
  • Zhu, Mengshi
  • Murayama, Hideaki
Fecha de publicación: 2024-06-21, This study presents a new quasi-distributed vibration sensing approach with a 3-cm spatial resolution, capable of performing multiparameter measurements. In-line interferometers are employed simultaneously as strain point sensors and reflectors for vibration monitoring due to the Doppler effect. The interferometers consist of capillary fiber segments spliced between single-mode fibers, forming a sensing etalon. A study of the characteristics required for the fiber array fabrication is carried out. A 60 cm array comprising 20 sensing sections is used for the proof-of-concept of the technique for strain and vibration sensing. An analysis of the behavior for static strain and vibrations is performed, both individually and simultaneously, using a free-end cantilever experiment., This work was supported in part by MCIN/AEI/10.13039/501100011033 and FEDER "A way to make Europe", under Project PID2022-137269OB-C21, in part by MCIN/AEI/10.13039/501100011033 and European Union "Next generation EU"/PRTR, under Project TED2021-130378B-C22, and in part by the Science and Technology Commission of Shanghai Municipality, China under Grant 23002400300. Open access funding provided by Public University of Navarre.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Measurement of paracetamol concentration using an erbium-doped fiber ring cavity

  • Soares, Liliana
  • Pérez Herrera, Rosa Ana
  • Novais, Susana
  • Ferreira, António
  • Silva, Susana
  • Frazão, Orlando
Process Analytical Technology (PAT) has been increasingly used in the pharmaceutical industry to monitor essential parameters in real-time during pharmaceutical processes. The concentration of Active Pharmaceutical Ingredients (APIs), such as paracetamol, is one of these parameters, and controlling its variations allows for optimization of the production process. In this study, a refractometric sensor, implemented by an interrogation system based on an Erbium-Doped Fiber Ring Cavity (EDFRC), was presented and experimentally demonstrated. The Cavity Ring proposed included a 1 × 3 coupler. One port of the coupler was used to increase the optical power of the system through a Fiber Bragg Grating (FBG), and the other two ports were used as sensing head and reference. The sensor detected variations of paracetamol concentration with a sensitivity of [(−1.00 ± 0.05) × 10−3] nW/(g/kg) and a resolution of 5.53 g/kg. The results demonstrate the potential of this technology as a possible non-invasive PAT tool., and European Union “Next generation EU”/PTR. Liliana Soares acknowledges the support of FCT, Portugal, through the Grant 2020.05297.BD.This research was funded by: National Funds through the Portuguese funding agency, FCT—Fundação para a Ciência e a Tecnologia, within project UIDB/50014/2020; National Funds through FCT/MCTES (PIDDAC), within projects LA/P/0045/2020 (ALiCE), UIDB/00511/2020, and UIDP/00511/2020 (LEPABE); Program “José Castillejo para estancias de movilidad en el extranjero de jóvenes doctores”, funded by the Ministerio de Univesidades of Spain (reference CAS21/00351); project PID2019-107270RB-C22, funded by MCIN/AEI/10.13039/501100011033 and FEDER “A way to make Europe”; projects PDC2021-121172-C21 and TED2021-130378B-C22, funded by MCIN/AEI/10.13039/501100011033