Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 1
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo de revisión (ReviewArticle)

Measurement of energy resolution with the NEXT-White silicon photomultipliers

  • Contreras, T.
  • Palmeiro, B.
  • Almazán, H.
  • Para, A.
  • Martinez-Lema, G.
  • Guenette, R.
  • Adams, C.
  • Aparicio, B.
  • Aranburu, A. I.
  • Arazi, L.
  • Arnquist, I.J.
  • Auria-Luna, F.
  • Ayet, S.
  • Azevedo, C.D.R.
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] The NEXT-White detector, a high-pressure gaseous xenon time projection chamber, demonstrated the excellence of this technology for future neutrinoless double beta decay searches using photomultiplier tubes (PMTs) to measure energy and silicon photomultipliers (SiPMs) to extract topology information. This analysis uses 83mKr data from the NEXT-White detector to measure and understand the energy resolution that can be obtained with the SiPMs, rather than with PMTs. The energy resolution obtained of (10.9±0.6)%, full-width half-maximum, is slightly larger than predicted based on the photon statistics resulting from very low light detection coverage of the SiPM plane in the NEXT-White detector. The difference in the predicted and measured resolution is attributed to poor corrections, which are expected to be improved with larger statistics. Furthermore, the JHEP09(2024)112 noise of the SiPMs is shown to not be a dominant factor in the energy resolution and may be negligible when noise subtraction is applied appropriately, for high-energy events or larger SiPM coverage detectors. These results, which are extrapolated to estimate the response of large coverage SiPM planes, are promising for the development of future, SiPM-only, readout planes that can offer imaging and achieve similar energy resolution to that previously demonstrated with PMTs., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under Grant Agreement No. 951281-BOLD; the European Union’s Framework Programme for Research and Innovation, Horizon 2020 (2014–2020), under Grant Agreement No. 957202-HIDDEN; Spain’s MCIN/AEI and the ERDF (“A way of making Europe”) under grants PID2021-125475NB and the Severo Ochoa Programme grant CEX2018-000867-S; the Generalitat Valenciana (Spain) under grants PROMETEO/2021/087 and CIDEGENT/2019/049; the Department of Education of the Basque Government (Spain) under the predoctoral training programme for non-doctoral research personnel; the “la Caixa” Foundation (ID 100010434) under fellowship code LCF/BQ/PI22/11910019; the Portuguese Foundation for Science and Technology (FCT) under project UID/FIS/04559/2020 supporting the activities of LIBPhys-UC; the Israel Science Foundation (ISF) under grant 1223/21; the Pazy Foundation (Israel) under grants 310/22, 315/19, and 465; the U.S. Department of Energy under contract numbers DE-AC02-06CH11357 (Argonne National Laboratory), DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M), DE-SC0019054 (The University of Texas at Arlington), and DE-SC0019223 (The University of Texas at Arlington); the U.S. National Science Foundation under award NSF CHE-2004111; and the Robert A. Welch Foundation under award Y-2031-20200401. Finally, we are grateful to the Laboratorio Subterráneo de Canfranc for hosting and supporting the NEXT experiment.