Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Capítulo o parte de un libro (BookPart)

Applicability Limits of Simplified Human Blockage Models at 5G mm-Wave Frequencies

  • Romero-Peña, Jhoan Samuel
  • Cardona Marcet, Narciso|||0000-0001-5697-1453
This paper analyzes the feasibility of using a simple diffraction model to compute the blocking of the human body to millimeter wave radio frequencies in indoor environments. The model makes a set of approximations that are evaluated to determine the applicability limits of such simplified approach, in particular for the human body blockage case. The work presented here: (1) describes briefly the mathematical support that is used to model the concealment using the Knife-Edge model, (2) identifies the potential simplifications applicable to the mathematical model implementation that allow a 3D geometric human body to be modelled with simple 2D shapes, (3) characterizes the polarization influence on the mm-wave blocking for such simplified human body models., This work was supported by the H2020 Marie Curie program, with project grant no: 766231 WAVECOMBEITN-2017
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Capítulo o parte de un libro (BookPart)

Initial Delay Domain UWB Channel Characterization for In-body Area Networks

  • Pérez-Simbor, Sofia
  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
  • Cardona Marcet, Narciso|||0000-0001-5697-1453
Wireless Body Area Networks (WBANs) have increased the attention of the research community for the next generation wireless medical devices. Among others, Wireless Capsule Endoscopy (WCE) aims to transmit better quality images. For this, the Ultra Wideband (UWB) frequency band is becoming a good alternative to currently allocated frequencies for in-body networks, allowing higher data rate and having a low power transmission. Common channel characterization in WBANs are performed in frequency domain, i.e., analyzing the received power as a function of frequency. Nevertheless, indepth studies in delay domain analyzing the impulse response of the channel are barely considered in current literature. In this paper, an initial study in delay domain, i.e., the Power Delay Profile (PDP) characteristics, is performed. Moreover, a comparison between the channel response in frequency and delay domain is performed. This work gives an insightful view of the impulse response of the channel for in-body to on-body communications. For that, an extensive campaign of phantom measurements and software simulations are conducted., This work was supported by the European Union’s H2020:MSCA:ITN program for the ”Wireless In-body Environment Communication- WiBEC” project under the grant agreement no. 675353. This work was also funded by by the European Union’s H2020: MSCA: ITN program for the ”mmWave Communications in the Built Environments - WaveComBE” project under the grant agreement no. 766231.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Capítulo o parte de un libro (BookPart)

Analysis of the Localization Error for Capsule Endoscopy Applications at UWB Frequencies

  • Barbi, Martina
  • Pérez-Simbor, Sofia
  • Garcia-Pardo, Concepcion|||0000-0002-2774-980X
  • Cardona Marcet, Narciso|||0000-0001-5697-1453
Localization for Wireless Capsule Endoscopy (WCE) in the Ultra-Wideband frequency band is a very active field of investigation due to its potential advantages in future endoscopy applications. Received Signal Strength (RSS) based localization is commonly preferred due to its simplicity. Previous studies on Ultra-Wideband (UWB) RSS-based localization showed that the localization accuracy depends on the average ranging error related to the selected combination of receivers, which not always is the one experiencing the highest level of received power. In this paper the tendency of the localization error is further investigated through supplementary software simulations and previously conducted laboratory measurements. Two-dimensional (2D) and three-dimensional (3D) positioning are performed and the trend of the localization error compared in both cases. Results shows that the distribution of the selected path loss values, corresponding to the receivers used for localization, around the in-body position to estimate also affects the localization accuracy., This work was supported by the H2020:MSCA:ITN program for the “Wireless In-body Environment Communication- WiBEC” project under the grant agreement no. 675353. This work was also supported by the European Union’s H2020:MSCA:ITN program for the ”mmWave Communications in the Built Environments - WaveComBE” project under the grant agreement no. 766231.