Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Control of PMSG-based wind turbines in weak grids during unbalanced faults

  • Blasco-Gimenez, Ramon|||0000-0003-3427-1581
  • Añó Villalba, Salvador Conrado|||0000-0002-8435-5225
  • Peña, R.S.
[EN] This paper includes the study of a control strategy for the connection of PMSG-based wind turbines during unbalanced faults in weak grids. The wind turbine front-end converter is controlled in the stationary frame by the direct calculation of current references. In this way, it is possible to keep a reasonably smooth generated power during the fault, in order to reduce the fault impact on the wind turbine mechanical components. The effects on the mechanical parts of the wind turbine have been studied by using the NREL 5 MW reference wind turbine, modeled with the NREL FAST code., The present work was supported by the Spanish Ministry of Science and Technology funds under Grant DPI2010- 16714, and by the Generalitat Valenciana funds under Grant ACOMP/2013/116. The financial support of Fondecyt Chile under Contract 1121104 and CONICYT/FONDAP/15110019 is also kindly acknowledged.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Model aggregation of large wind farms for dynamic studies

  • Martínez-Turégano, Jaime|||0000-0002-3483-8253
  • Añó Villalba, Salvador Conrado|||0000-0002-8435-5225
  • Bernal-Perez, Soledad|||0000-0002-5431-9792
  • Blasco-Gimenez, Ramon|||0000-0003-3427-1581
  • Chaqués-Herráiz, G.
[EN] A large number of nodes is required for the detailed simulation of large off-shore wind farms. Therefore, the corresponding electromagnetic transient simulations require large simulation times. This paper compares a detailed model of an off-shore wind farm with three clusters of 50 wind turbines each one (i.e. a total of 150 wind turbines), with a simplified model consisting of three aggregated wind farms. The paper includes the aggregation criteria so equal power flows and voltages are obtained at the wind farms points of common coupling. The control is carried out using a centralized PI controller to control total active power, and a distributed droop control for active and reactive power control of each wind turbine. The proposed aggregation method leads to significant savings on computational times, with the aggregated models being more than three hundred and fifty times faster than the detailed ones. The results have been validated by means of detailed PSCAD/EMTDC simulations.v, The authors would like to thank the support of the Spanish Ministry of Economy and EU FEDER funds under grant DPI2014-53245-R. The support of CONICYT/FONDAP/15110019 and Fondecyt 1151325 is also kindly acknowledged. This project has received funding from the European Union's Horizon 2020 research and innovation program under grant agreement No. 691714.