Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 103
Encontrada(s) 2 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

A multiobjective-based switching topology for hierarchical model predictive control applied to a hydro-power valley

  • Núñez, Alfredo
  • Ocampo-Martínez, Carlos
  • Schutter, Bart de
  • Valencia, Felipe
  • López, José David
  • Espinosa, Jairo
Trabajo presentado al 3rd IFAC International Conference on Intelligent Control and Automation Science (2013)., In a Hierarchical Model Predictive Control (H-MPC) framework, this paper explores suitable time-variant structures for the hierarchies of different local MPC controllers. The idea is to adapt to different operational conditions by changing the importance of the local controllers. This is done by defining the level of the hierarchy they belong to, and solving within each level the local MPC problem using the information provided by the higher levels at the current time step and the predicted information from the lower levels obtained in the previous time step. As selecting a hierarchy results in a combinatorial optimization problem, it is explicitly solved for a limited number of relevant topologies only and then the switching between topologies is defined with a multiobjective optimizer, so as to decide the best H-MPC scheme according to the expected performance. A comparison with fixed-topology H-MPC controllers is done, showing the effectiveness of the proposed approach for the power control of a hydro-power valley., Research supported by the European 7th Framework Net-work of Excellence Highly complex and networked control systems (HYCON2), the European COST Action TU1102 and COLCIENCIAS through Fondo Nacional de Financiamiento Para la Ciencia la Tecnología y la Innovación, Francisco Jose de Caldas, project Modelamiento y control de tráfico urbano en la ciudad de Medellín contract number 0941-2012. The work of C. Ocampo-Martinez has been supported by Secretaria d’Universitats i Recerca i del Departament d’Economia i Coneixement - Generalitat de Catalunya and the the EU Project EFFINET (FP7-ICT-2011-8-31855), Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Multi-layer model predictive control of regional water networks: Application to the Catalunya case study

  • Sun, Congcong
  • Puig, Vicenç
  • Cembrano, Gabriela
Trabajo presentado al 52nd CDC celebrado en Florencia del 10 al 13 de diciembre de 2013., A multi-layer model predictive control (MPC) scheme with temporal multi-level coordination for regional water networks is proposed. First, a multi-layer control structure resulting from a functional decomposition of water network is briefly presented. Inside each layer, a MPC based controller is used. Between related layers, a temporal multi-level coordination mechanism is used to generate control strategies which consider objectives and time scales of both layers. The proposed approach will be applied to the Catalunya Regional Water Network. The paper presents the results based on an aggregate model of this network., This work has been funded by the Spanish Ministry of Science and Technology through the project CYCYT WATMAN DPI2009-13744 and by EFFINET grant FP7-ICT-012-318556 of the European Commission., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Receding horizon control of hybrid linear delayed systems: Application to sewer networks

  • Joseph-Duran, Bernat
  • Ocampo-Martínez, Carlos
  • Cembrano, Gabriela
Trabajo presentado al 52nd CDC celebrado en Florencia del 10 al 13 de diciembre de 2013., A control-oriented hybrid linear model for water transport in sewer networks is proposed as a suitable framework for the computation of real-time controllers for the minimization of flooding in presence of heavy-rain events. The model is based on individual network elements (sewers, gates, weirs and tanks) and does not rely on topological simplifications, thus providing a better description of the hydrological and hydraulic phenomena than in similar works. Using a generic form of a hybrid linear model, a simple matrix-based procedure for the formulation and solution of an optimal control problem is also presented. This procedure is applied to the sewer network model for the case study of a part of the Barcelona sewer network in a receding horizon control strategy, showing the effectiveness of the proposed control approach., This work has been partially funded by the Spanish project WATMAN (DPI2009-13744), the EU Project EFFINET (FP7-ICT-2011-8-318556), and the JAE-PreDoc program of the Spanish National Research Council (CSIC)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Linear parameter varying modeling and identification for real-time control of open-flow irrigation canals

  • Bolea, Yolanda
  • Puig, Vicenç
  • Blesa, Joaquim
Irrigation canals are open-flow water hydraulic systems, whose objective is mainly to convey water from its source down to its final users. They are large distributed systems characterized by non-linearity and dynamic behavior that depends on the operating point. Moreover, in canals with multiple reaches dynamic behavior is highly affected by the coupling among them. The physical model for those systems leads to a distributed-parameter model whose description usually requires partial differential equations (PDEs). However, the solution and parameter estimation of those PDE equations can only be obtained numerically and imply quite time-consuming computations that make them not suitable for real-time control purposes. Alternatively, in this paper, it will be shown that open-flow canal systems can be suitably represented for control purposes by using linear parameter-varying (LPV) models. The advantage of this approach compared to the use of PDE equation is that allows simpler models which are suitable for control design and whose parameters can be easily identified from input-output data by means of classical identification techniques. In this paper, the well-known control-oriented, model named integral delay zero (IDZ), that is able to represent the canal dynamics around a given operating point by means of a linear time-invariant (LTI) model is extended to multiple operating points by means of an LPV model. The derivation of this LPV model for single-reach open-flow canal systems as well as its extension to multiple-reach open-flow canals is proposed. In particular, the proposed methodology allows deriving the model structure and estimating model parameters using data by means of identification techniques. Thus, a gray-box control model is obtained whose validation is carried out using single-pool and two-pool test canals obtaining satisfactory results. © 2013 Elsevier Ltd., This work has been partially grant-funded by CICYT SHERECS DPI- 2011-26243 and CICYT WATMAN DPI- of the Spanish Ministry of Education, by EFFINET grant FP7-ICT-2012-318556 of the European Commission., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

A decision support system for on-line leakage localization

  • Meseguer, Jordi
  • Mirats-Tur, Josep M.
  • Cembrano, Gabriela
  • Puig, Vicenç
  • Quevedo, Joseba
  • Pérez, Ramon
  • Sanz, Gerard
  • Ibarra, David
This paper describes a model-driven decision-support system (software tool) implementing a model-based methodology for on-line leakage detection and localization which is useful for a large class of water distribution networks. Since these methods present a certain degree of complexity which limits their use to experts, the proposed software tool focuses on the integration of a method emphasizing its use by water network managers as a decision support system. The proposed software tool integrates a model-based leakage localization methodology based on the use of on-line telemetry information, as well as a water network calibrated hydraulic model. The application of the resulting decision support software tool in a district metered area (DMA) of the Barcelona distribution network is provided and discussed. The obtained results show that the leakage detection and localization may be performed efficiently reducing the required time. © 2014 Elsevier Ltd., The authors wish to thank the support received by the AM0901 project funded by R+i Alliance (Suez Environnement) and by the EFFINET grant FP7-ICT-2012-318556 of the European Commission., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Combining CSP and MPC for the operational control of water networks: Application to the Richmond case study

  • Sun, Congcong
  • Puig, Vicenç
  • Cembrano, Gabriela
Trabajo presentado al 19th IFAC World Congress celebrado del 24 al 29 de agosto de 2014 en Cape Town (Sudafrica)., This paper presents the combination of Linear Model Predictive Control (MPC) with Constraints Satisfaction Problem (CSP) for the operational control of drinking water networks. The methodology has been divided into two functional layers: First, a CSP algorithm is used to transfer nonlinear pressure equations of drinking water networks (DWNs) into linear constraints, which can enclose feasible solution of the hydraulic non-linear problem during the optimizing process. Then, a linear MPC with added linear constraints is solved. Finally, the proposed approach is simulated using Epanet to represent the real DWNs. PLIO, which is a generic operational tool for controlling water network that uses non-linear MPC, is used for validation. The classical Richmond water system is used as a case study., This research has been partially funded by the DGR of Generalitat de Catalunya (SAC group Ref. 2009/SGR/1491), Doctorat Industrial 2013-DI-041 and by EFFINET., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Constrained distributed optimization based on population dynamics

  • Barreiro-Gómez, Julian
  • Quijano, Nicanor
  • Ocampo-Martínez, Carlos
Trabajo presentado a la 53rd IEEE Conference on Decision and Control (CDC 2014), celebrada del 15 al 17 de diciembre en Los Angeles, California (US)., This paper proposes a novel methodology for solving constrained optimization problems in a distributed way, inspired by population dynamics and adding dynamics to the population masses. The proposed methodology divides the problem into smaller problems, whose feasible regions vary over time achieving an agreement to solve the global problem. The methodology also guarantees attraction to the feasible region and allows to have few changes in the decision-making design, when the network suffers the addition or removal of nodes. Simulation results are presented in order to illustrate several cases., J. Barreiro-Gomez is supported by COLCIENCIAS and by the Agència de Gestió d’Ajust Universitaris i de Recerca AGAUR. This work has been supported by the projects COLCIENCIAS 548/2012, and the EU project EFFINET (Ref. FP7-ICT-2011-8-31855), Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Distributed control of drinking water networks using population dynamics: Barcelona case study

  • Barreiro-Gómez, Julian
  • Quijano, Nicanor
  • Ocampo-Martínez, Carlos
  • Ocampo-Martínez, Carlos
Trabajo presentado a la 53rd IEEE Conference on Decision and Control (CDC 2014), celebrada del 15 al 17 de diciembre en Los Angeles, California (US)., Large-scale network systems involve a large number of variables, making the design of real-time controllers challenging. A distributed controller design allows to reduce computational requirements since tasks may be divided into different subsystems, making possible to guarantee real-time processing. This paper proposes a constrained optimization based distributed control design by applying a novel population and masses dynamics approach. The distributed controller design is applied to the Barcelona Drinking Water Network (DWN) in order to illustrate its effectiveness in the control performance., This work has been partially supported by the projects COLCIENCIAS 548/2012, ECOCIS (Ref. DPI2013-48243-C2-1-R) and EFFINET (Ref. FP7-ICT-2011-8-31855). J. Barreiro-Gómez is supported by COLCIENCIAS and by the Agència de Gestió d’Ajust Universitaris i de Recerca AGAUR., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Gaussian-process-based demand forecasting for predictive control of drinking water networks

  • Wang, Ye
  • Ocampo-Martínez, Carlos
  • Puig, Vicenç
  • Quevedo, Joseba
Trabajo presentado a la 9th International Conference on Critical Information Infrastructures Security, celebrada en Limassol (Chipre) del 13 al 15 de octubre de 2014., This paper focuses on short-term water demand forecasting for predictive control of DrinkingWater Networks (DWN) by using Gaussian Process (GP). For the predictive control strategy, system state prediction in a nite horizon are generated by a DWN model and demands are regarded as system disturbances. The goal is to provide a demand estimation within a given condence interval. For the sake of obtaining a desired forecasting performance, the forecasting process is carried out in two parts: the expected part is forecasted by Double-Seasonal Holt-Winters (DSHW) method and the stochastic part is forecasted by GP method. The mean value of water demand is rstly estimated by DSHW while GP provides estimations within a condence interval. GP is applied with random inputs to propagate uncertainty at each step. Results of the application of the proposed approach to a real case study based on the Barcelona DWN have shown that the general goal has been successfully reached., This work is partially supported by the research projects SHERECS DPI-2011-26243 and ECOCIS DPI-2013-48243-C2-1-R, both of the Spanish Ministry of Education, by EFFINET grant FP7-ICT-2012-318556 of the European Commission and by AGAUR Doctorat Industrial 2013-DI-041. Ye Wang also thanks China Scholarship Council for providing postgraduate scholarship., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

On the assessment of tree-based and chance-constrained predictive control approaches applied to drinking water networks

  • Grosso, J. M.
  • Maestre, Jose Maria
  • Ocampo-Martínez, Carlos
  • Puig, Vicenç
Trabajo presentado al 19th IFAC World Congress celebrado del 24 al 29 de agosto de 2014 en Cape Town (Sudafrica)., Water systems are a challenging problem because of their size and exposure to uncertain influences such as the unknown demands or the meteorological phenomena. In this paper, two different stochastic programming approaches are assessed when controlling a drinking water network: chance-constrained model predictive control (CC-MPC) and tree-based model predictive control (TB-MPC). Under the former approach, the disturbances are modeled as stochastic variables with non-stationary uncertainty description, unbounded support and quasi concave probabilistic distribution. A deterministic equivalent of the related stochastic problem is formulated using Boole¿s inequality and a uniform allocation of risk. In the later approach, water demand is modelled as a disturbance rooted tree where branches are formed by the most probable evolutions of the demand. In both approaches, a model predictive controller is used to optimise the expectation of the operational cost of the disturbed system., This research has been supported by the EU Project EFFINET (FP7-ICT-2011-8-31855), the EU Network of Excellence Highly Complex and Networked Control Systems (HYCON2) under grant agreement no. 257462, and the DGR of Generalitat de Catalunya (SAC group Ref. 2009/SGR/1491)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

On the comparison of predictive control and command governor approaches for operational control of drinking water networks: A case study

  • Tedesco, Francesco
  • Ocampo-Martínez, Carlos
  • Cassavola, Alessandro
  • Puig, Vicenç
Trabajo presentado al 19th IFAC World Congress celebrado del 24 al 29 de agosto de 2014 en Cape Town (Sudafrica)., This paper evaluates the application of command governor (CG) strategy for the operational control of drinking water networks (DWN) given their large-scale and complex nature, the permanent and relevant effect of the disturbances (water demands) and their marginal stability feature. Moreover, the performance improvement offered by CG is compared with the application of model predictive control for the same management purposes and in the same context. The paper also discusses the effectiveness of both strategies and highlights the advantages of each approach. The Barcelona DWN is considered as case study for the undertaken assessment analysis., This work has been partially supported by the EU Project EFFINET (FP7-ICT-2011-8-31855) and the DGR of Generalitat de Catalunya (SAC group Ref. 2009/SGR/1491)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

A distributed command governor strategy for the operational control of drinking water networks

  • Tedesco, Francesco
  • Ocampo-Martínez, Carlos
  • Cassavola, Alessandro
  • Puig, Vicenç
Trabajo presentado a la IEEE Conference on Control Applications (CCA) celebrada en Juan-les-Pins, Antibes (Francia) del 8 al 10 de octubre de 2014., This paper proposes the application of a distributed command governor (DCG) strategy for the operational control of drinking water networks (DWN). This approach is very suitable to this kind of management problems given the large-scale and complex nature of DWNs, the relevant effect of persistent disturbances (water demands) over the network evolutions and their marginal stability feature. The performance improvement offered by DCG is compared with the consideration of two non-centralized model predictive control (MPC) approaches already proposed for the same management purposes and within the same context. The paper also discusses the effectiveness of all strategies and highlights the advantages of each approach. The Barcelona DWN is considered as the case study for the assessment analysis., This work has been partially supported by the European Commission (FP7-ICT-2011-8-318556), the European Social Fund and the Calabria Region., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Two-layer scheduling scheme for pump stations

  • Sun, Congcong
  • Puig, Vicenç
  • Cembrano, Gabriela
Trabajo presentado a la IEEE Conference on Control Applications (CCA) celebrada en Juan-les-Pins, Antibes (Francia) del 8 al 10 de octubre de 2014., In this paper, a two-layer scheduling scheme for pump stations in a water distribution network has been proposed. The upper layer, which works in one-hour sampling time, uses Model Predictive Control (MPC) to produce continuous flow set-points for the lower layer. While in the lower layer, a scheduling algorithm has been used to translate the continuous flow set-points to a discrete (ON-OFF) control operation sequence of the pump stations with the constraints that pump stations should draw the same amount of water as the continuous flow set-points provided by the upper layer. The tuning parameters of such algorithm are the lower layer control sampling period and the number of parallel pumps in the pump station. The proposed method has been tested in the Richmond case study., This work has been funded by the Spanish Ministry of Science and Technology through the project CYCYT WATMAN DPI2009-13744 and also funded by EFFINET grant FP7-ICT-2012-318556 of the European Commission., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Coordinating multi-layer MPC for complex water systems

  • Sun, Congcong
  • Puig, Vicenç
  • Cembrano, Gabriela
Trabajo presentado a la 26th Chinese Control and Decision Conference (2014 CCDC) celebrada del 31 de mayo al 2 de junio en Changsha (China)., In this paper, coordinating technique for the multi-layer model predictive control (MPC) of complex water network is proposed. A multi-layer topology structure resulting from a functional decomposition of water network is briefly presented. Inside each layer, a MPC based controller is used. Between the related two layers, a multi-layer coordinating mechanism is provided to generate control strategies which consider objectives and time scales of both layers. Optimal Path Method (OPM) is used to estimate aggregated water price for the whole layer. The case study is the Catalunya Regional Water Network. Simulation results based on an aggregate model of this network are provided., This research has been partially funded by CDTI (MCyT) project HIDROPTIM IDI-20100722, the DGR of Generalitat de Catalunya (SAC group Ref. 2009/SGR/1491), the AGAUR by an FI grant and by EFFINET grant FP7-ICT-2012-318556 of the European Commission., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Economic MPC for the management of drinking water networks

  • Grosso, J. M.
  • Ocampo-Martínez, Carlos
  • Puig, Vicenç
  • Limon, D.
  • Pereira, M.
Trabajo presentado a la European Control Conference (ECC) celebrada en Estrasburgo (Francia) del 24 al 27 de junio de 2014., This paper addresses the management of drinking water networks (DWNs) regarding a multi-objective cost function by means of economically-oriented model predictive control (EMPC) strategies. Specifically, assuming the water demand and the energy price as periodically time-varying signals, this paper shows that the EMPC framework is flexible to enhance the control of DWNs without relying on hierarchical control schemes that require the use of real-time optimisers (RTO) or steady-state target optimisers (SSTO) in an upper layer. Four different MPC strategies are discussed in this paper: a hierarchical two-layer approach, a standard EMPC where the multi-objective cost function is optimised directly, and two different modifications of the latter, which are meant to overcome possible feasibility losses in the presence of changing operating patterns. The discussed schemes are tested andcompared by means of a case study taken from a part of the Barcelona DWN., This work has been partially funded by the EU Project EFFINET (FP7-ICT-2011-8-31855) and the DGR of Generalitat de Catalunya (SAC group Ref. 2009/SGR/1491)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

On the modeling and real-time control of urban drainage systems: A survey

  • García Gutiérrez, Luis Antonio
  • Escobar, Eduardo
  • Barreiro-Gómez, Julian
  • Quijano, Nicanor
  • Ocampo-Martínez, Carlos
  • Téllez, Duván
Trabajo presentado a la 11th International Conference on Hydroinformatics celebrada en New York (US) del 17 al 21 de agosto de 2014., Drainage networks are complex systems composed by several processes including recollection, transport, storing, treatment, and releasing the water to a receiving environment. The way Urban Drainage Systems (UDS) manage wastewater is through the convenient handling of active elements such as gates (redirection and/or retention), storing tanks, and pumping stations, when needed. Therefore, modeling and control of UDS basically consists in knowing and representing the (dynamical) behavior of these elements and managing them properly in order to achieve a given set of control objectives, such as minimization of flooding in streets or maximization of treated wastewater in the system. Given the large number of elements composing an UDS and the interaction between them, management and control strategies may depend on highly complex system models, which implies the explicit difficulty for designing real-time control (RTC) strategies. This paper makes a review of the models used to describe, simulate, and control UDS, proposes a revision of the techniques and strategies commonly used for the control UDS, and finally compares several control strategies based on a case study., This work has been partially supported by project N°548-2012 “Drenaje Urbano y Cambio Climático: Hacia los Sistemas de Alcantarillado del Futuro.”, Mexichem Colombia S.A, the scholarships of Colciencias N°567-2012 and 647-2013, and the EU Project EFFINET (FP7-ICT-2011-8-31855) and the DGR of Generalitat de Catalunya (SAC group Ref. 2009/SGR/1491)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Real-time monitoring and control for efficient management of drinking water networks: Barcelona case study

  • Cembrano, Gabriela
  • Puig, Vicenç
  • Ocampo-Martínez, Carlos
  • Quevedo, Joseba
  • Mirats-Tur, Josep M.
  • Meseguer, Jordi
  • Ariño, Ramon
  • López, Silvia
Trabajo presentado a la 11th International Conference on Hydroinformatics celebrada en New York (US) del 17 al 21 de agosto de 2014., This research has been partially funded by the DGR of Generalitat de Catalunya (SAC group Ref. 2009/SGR/1491), Doctorat Industrial AGAUR-2013-DI-041 and by EFFINET: Efficient Integrated Real-time Monitoring and Control of Drinking Water Networks (FP7-ICT2011-8-318556)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Model-free control for wind farms using a gradient estimation-based algorithm

  • Barreiro-Gómez, Julian
  • Ocampo-Martínez, Carlos
  • Bianchi, Fernando D.
  • Quijano, Nicanor
Trabajo presentado a la European Control Conference celebrada en Linz (Alemania) del 15 al 17 de julio de 2015., Wind turbines working close to other turbines experience interactions that affect the power production. These interactions arise as a consequence of wakes caused by upstream wind turbines. In order to achieve a more effective and precise control of the power generated by wind farms, the control strategy must consider these interactions. However, the phenomena involved in wake effects are complex especially in cases of large number of turbines. This paper presents the implementation of a gradient estimation-based algorithm as a model-free control for two different control schemes aimed to maximize the energy capture of a wind farm. One control is centralized, leaving to a supervisor the task of command computation and the other topology is decentralized, distributing the performing generation among wind turbines. This latter scheme aims to increase the reliability of the wind farm operation by reducing the communications needed to fulfill the objective of maximizing energy capture. Both control schemes are evaluated by simulation in the case of three-turbine wind farm., J. Barreiro-Gomez is supported by Colciencias and by Agència de Gestió d’Ajust Universitaris i de Recerca AGAUR. This work has been partially supported by the projects ECOCIS (Ref. DPI2013-48243-C2-1-R), EFFINET (Ref.FP7-ICT-2011-8-31855), and ALTERNAR, Acuerdo 005, 07/19/13, CTeI-SGR-Narino, Colombia., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Decentralized control for urban drainage systems via population dynamics: Bogotá case study

  • Barreiro-Gómez, Julian
  • Obando, Germán
  • Riaño-Briceño, G.
  • Quijano, Nicanor
  • Ocampo-Martínez, Carlos
Trabajo presentado a la European Control Conference celebrada en Linz (Alemania) del 15 al 17 de julio de 2015., Control of Urban Drainage Systems (UDS) is studied for cases in which the distribution of run–off through the channels of a system is inefficient, i.e. when the capacity of some structures is not used optimally. In this paper, a decentralized population-dynamics-based control for UDS is presented, particularly using the replicator and projection dynamics. For the design, a methodology to make a partitioning of the system is introduced, and the design of a population–dynamics–based control per each partition is proposed. Moreover, a stability analysis of the closed–loop system is made by using passivity theory. Finally, simulation results show the proposed approach performance in a segment of the Bogota stormwater UDS case study., COLCIENCIAS supports J. Barreiro-Gómez and G. Obando. Agència de Gestió d’Ajust Universitaris i de Recerca AGAUR supports J. Barreiro-Gómez. This work has been partially supported by the projects “Drenaje urbano y cambio climático: Hacia los sistemas de alcantarillados del futuro. Fase II. COLCIENCIAS 633/2013”, ECOCIS (Ref. DPI2013-48243-C2-1-R), and EFFINET (Ref. FP7-ICT-2011-8-31855)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Robust model predictive control based on Gaussian processes: Application to drinking water networks

  • Wang, Ye
  • Ocampo-Martínez, Carlos
  • Puig, Vicenç
Trabajo presentado a la European Control Conference celebrada en Linz (Alemania) del 15 al 17 de julio de 2015., In this paper, a controller design based on robust Model Predictive Control (MPC) and Gaussian Processes (GP) for incorporating the disturbance forecasting has been proposed. Using a probabilistic system representation, the state trajectories considering the influence of disturbances can be obtained through the uncertainty propagation by using GP. Therefore, the worst-case state trajectories evolution over the MPC prediction horizon can be determined, which are potentially used by including them into the MPC cost function and constraints. For the purpose of inspecting the performance of proposed controller, it has been compared with a certain equivalent MPC and a chance-constrained MPC. Results of the application the proposed approach to Barcelona Drinking Water Network (DWN) have shown the effectiveness of the approach and comparison results with the other considered MPC approaches have shown the advantages and drawbacks of each approach., This work has been partially supported by the projects ECOCIS (DPI-2013-48243-C2-1-R) and EFFINET (FP7-ICT-2012-318556)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Combining model predictive control with constraint-satisfaction formulation for the operative pumping control in water networks

  • Sun, Congcong
  • Morley, Mark
  • Savic, Dragan
  • Puig, Vicenç
  • Cembrano, Gabriela
  • Zhang, Zheng
Under a Creative Commons license.-- Trabajo presentado a la 13th Computing and Control for the Water Industry (CCWI2015): "Sharing the best practice in water management", celebrada en De Montfort University (UK) del 2 al 4 de septiembre de 2015., This paper proposes a method to combine linear Model Predictive Control (MPC), a Constraint Satisfaction Problem (CSP)formulation and a Network Aggregation Method (NAM) for the predictive operational control of water pumping in DWNs. The proposed method can produce optimal pumping strategies for complex DWNs in short computation times, while avoiding the need for non-linear programming techniques to cater for non-linear flow-head equations. The proposed approach is simulated using Epanet to represent the hydraulic DWNs. The D-Town benchmark water network is used as a case study., This research has been funded by DGR of Generalitat de Catalunya (SAC group Ref. 2009/SGR/1491), ECOCIS (DPI2013-48243-C2-1-R), EFFINET (FP7-ICT-2011-8-31855) and an FI grant by AGAUR., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Decentralised fault diagnosis of large-scale systems: Application to water transport networks

  • Puig, Vicenç
  • Ocampo-Martínez, Carlos
Trabajo presentado al 26th International Workshop on Principles of Diagnosis celebrado en Paris (Francia) del 31 de agosto al 3 de septiembre de 2015., In this paper, a decentralised fault diagnosis approach for large-scale systems is proposed. This approach is based on obtaining a set of local diagnosers using the analytical redundancy relation (ARRs) approach. The proposed approach starts with obtaining the set of ARRs of the system yielding into an equivalent graph. From that graph, the graph partitioning problem is solved obtaining a set of ARRs for each local diagnoser. Finally, a decentralised fault diagnosis strategy is proposed and applied over the resultant set of partitions and ARRs. In order to illustrate the application of the proposed approach, a case study based on the Barcelona drinking water network (DWN) is used., This work has been partially supported by the EFFINET grant FP7-ICT-2012-318556 of the European Commission and the Spanish project ECOCIS (Ref. DPI2013-48243-C2-1-R)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Making non-centralized a model predictive control scheme by using distributed Smith dynamics

  • Barreiro-Gómez, Julian
  • Obando, Germán
  • Ocampo-Martínez, Carlos
  • Quijano, Nicanor
Trabajo presentado al 5th IFAC Conference on Nonlinear Model Predictive Control (NMPC) celebrado en Sevilla (España) del 17 al 20 de septiembre de 2015., This paper proposes a non--centralized Model Predictive Control (MPC) scheme for a system comprised by several sub-systems. Operational constraints for each subsystem are considered as well as a single coupled constraint on the control inputs that models a limitation of the emph{resource} supplied by the controller. If the underlying optimization problem is of large-scale nature, traditional MPC suffers from computational burden issues. A cause of this problem is the requirement of having centralized information to guarantee that the computed control actions satisfy the coupled constraint. In this work, a traditional MPC is made non--centralized by means of a strategy based on distributed population dynamics. The proposed methodology divides the problem into several local MPC controllers that coordinate their decisions by using a communication network without the need of a centralized scheme. It is proved that this methodology provides an optimal solution that satisfies both the operational constraints of each sub--system, and the coupled constraint of the control signals. Finally, the proposed method is compared with a traditional centralized MPC in an industrial problem that involves several continuously stirred tank reactors., This work has been partially supported by the projects ECOCIS (Ref. DPI2013-48243-C2-1-R), EFFINET (Ref. FP7-ICT-2011-8-31855), and “Drenaje urbano y cambio climático: Hacia los sistemas de alcantarillados del futuro. Fase II. COLCIENCIAS 633/2013”. J. Barreiro-Gomez and G. Obando are partially supported by Colciencias-Colfuturo. J. Barreiro-Gomez is also partially supported by Agencia de Gestio d’Ajust Universitaris i de Recerca AGAUR., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Optimal pressure sensor placement in water distribution networks minimizing leak location uncertainty

  • Nejjari, Fatiha
  • Sarrate, Ramon
  • Blesa, Joaquim
Trabajo presentado a: Computing and Control for the Water Industry (CCWI2015) Sharing the best practice in water management., Under a Creative Commons license, In this paper an optimal sensor placement strategy based on pressure sensitivity matrix analysis and an exhaustive search strategy that maximizes some diagnosis specifications for a water distribution network is presented. An average worst leak expansion distance as a new leak location performance measure has been proposed. This metric is later used to assess the leak location uncertainty provided by a sensor configuration. The method is combined with a clustering technique in order to reduce the size and the complexity of the sensor placement problem. The strategy is successfully applied to determine the location of a set of pressure sensors in a district metered area in the Barcelona water distribution network., This work has been funded by the Spanish Ministry of Economy and Competitiveness through the CICYT projects ECOCIS (ref. DPI2013-48243- C2-1-R) and HARCRICS (ref. DPI2014-58104-R), and by the European Commission through contract EFFINET (ref. FP7-ICT2011-8-318556)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Leak localization in water distribution networks using pressure residuals and classifiers

  • Ferrandez-Gamot, Lise
  • Busson, Pierre
  • Blesa, Joaquim
  • Tornil-Sin, Sebastian
  • Puig, Vicenç
  • Duviella, Eric
  • Soldevila, Adrià
Trabajo presentado al 9th IFAC Symposium on Fault Detection, Supervision and Safety for Technical Processes (SAFEPROCESS) celebrado en Paris (Francia) del 2 al 4 de septiembre de 2015., In order to take into account the scarcity of the water resource and the increasing of the population, the management of drinking water networks has to be improved with the use of new tools and actions that allows fighting against wasting water. The monitoring of drinking water networks is based on the use of sensors to locate malfunctions (leaks, quality/contamination events, etc.). Practical implementation has to be carried out by optimizing the placement of the number of sensors and improving the detection and localization of malfunctions. Techniques for the detection and localization of leaks have been proposed in the last years based on the evaluation of residuals obtained by means of the comparison between the measurements obtained by the sensors and the values obtained by simulating the water network in a leak free scenario. In this paper, a data-driven approach based on the use of statistical classifiers working in the residual space is proposed for leak localization. The classifiers are trained using leak data scenarios in all the nodes of the network considering uncertainty in demand distribution, additive noise in sensors and leak magnitude. Finally, the proposed approach is tested using the well-known Hanoi network benchmark., This work has been partially funded by the Spanish Ministry of Science and Technology through the Project ECOCIS (Ref. DPI2013-48243-C2-1-R) and Project HARCRICS (Ref. DPI2014-58104-R), and by EFFINET grant FP7-ICT-2012-318556 of the European Commission., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Model-based monitoring techniques for leakage localization in distribution water networks

  • Meseguer, Jordi
  • Mirats-Tur, Josep M.
  • Cembrano, Gabriela
  • Puig, Vicenç
Trabajo presentado a: Computing and Control for the Water Industry (CCWI2015) Sharing the best practice in water management.-- Under a Creative Commons license, This paper describes an integrated model-based monitoring framework for leakage localization in district-metered areas (DMA) of water distribution networks, which takes advantage of the availability of a hydraulic model of the network. The leakage localization methodology is based on the use of flow and pressure sensors at the DMA inlets and a limited number of pressure sensors deployed inside the DMA. The placement of these sensors has been computed using an optimal sensor placement method based on a Genetic Algorithm optimization, which integrates the direct modelling approach (simulation) used to identify the location of leaks. The application of the resulting monitoring framework in a certain DMA of the Barcelona distribution network is provided and discussed using simulated leakage scenarios. The obtained results show that leakage detection and localisation may be performed efficiently, reducing the required time for detection/localization, by following a simple procedure., The authors wish to thank the support received by the EFFINET grant FP7-ICT-2012-318556 of the European Commission and the Spanish Research Grant of project ECOCIS (MINECO) DPI2013-48243-C2-1-R., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Optimal sensor placement for classifier-based leak localization in drinking water networks

  • Soldevila, Adrià
  • Tornil-Sin, Sebastian
  • Fernández Cantí, Rosa M.
  • Blesa, Joaquim
  • Puig, Vicenç
  • Puig, Vicenç
Trabajo presentado a la 3rd Conference on Control and Fault Tolerant Systems, celebrada en Barcelona (España) del 7 al 9 de septiembre de 2016., This paper presents a sensor placement method for classifier-based leak localization in Water Distribution Networks. The proposed approach consists in applying a Genetic Algorithm to decide the sensors to be used by a classifier (based on the k-Nearest Neighbor approach). The sensors are placed in an optimal way maximizing the accuracy of the leak localization. The results are illustrated by means of the application to the Hanoi District Metered Area and they are compared to the ones obtained by the Exhaustive Search Algorithm. A comparison with the results of a previous optimal sensor placement method is provided as well., This work has been partially funded by the Spanish Government (MINECO) through the project CICYT ECOCIS (ref. DPI2013-48243-C2-1-R), by MINECO and FEDER through the project CICYT HARCRICS (ref. DPI2014-58104-R), by MINECO through the grant IJCI-2014-2081, by EFFINET grant FP7-ICT-2012-318556 of the European Commission, by the DGR of Generalitat de Catalunya (SAC group Ref. 2014/SGR/374) and by the AGAUR of Generalitat de Catalunya through the grants FI-DGR 2015 (ref. 2015 FI B 00591) and 2014PDJ00102., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Sensor placement for leak monitoring in drinking water networks combining clustering techniques and a semi-exhaustive search

  • Sarrate, Ramon
  • Blesa, Joaquim
  • Nejjari, Fatiha
Trabajo presentado a la 3rd Conference on Control and Fault Tolerant Systems, celebrada en Barcelona (España) del 7 al 9 de septiembre de 2016., This paper presents an optimal sensor placement strategy based on pressure sensitivity matrix analysis and a semi-exhaustive search strategy that maximizes some diagnosis specifications for water distribution networks. A mean average worst leak expansion distance has been proposed as a new leak location performance measure. The approach is combined with a clustering technique in order to reduce the size and the complexity of the sensor placement problem. The strategy is successfully applied to determine the location of a set of pressure sensors in a district metered area (DMA) in the Barcelona water distribution network (WDN)., This work has been funded by the Spanish Government (MINECO) through the project CICYT ECOCIS (ref. DPI2013-48243-C2-1-R), by MINECO and FEDER through the project CICYT HARCRICS (ref. DPI2014-58104-R), by MINECO through the grant IJCI-2014-2081, by the DGR of Generalitat de Catalunya (SAC group Ref. 2014/SGR/374), by the AGAUR of Generalitat de Catalunya through the grant 2014PDJ00102 and by EFFINET grant FP7-ICT-2012-318556 of the European Commission., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Uncertainty effect on leak localisation in a DMA

  • Pérez, Ramon
  • Cugueró, Josep
  • Blesa, Joaquim
  • Cugueró-Escofet, Miquel Àngel
  • Sanz, Gerard
Trabajo presentado a la 3rd Conference on Control and Fault Tolerant Systems, celebrada en Barcelona (España) del 7 al 9 de septiembre de 2016., The leak localisation methodologies based on data and models are affected by both uncertainties in the model and in the measurements. This uncertainty should be quantified so that its effect on the localisation methods performance can be estimated. In this paper, a model-based leak localisation methodology is applied to a real District Metered Area using synthetic data. In the generation process of the data, uncertainty in demands is taken into account. This uncertainty was estimated so that it can justify the uncertainty observed in the real measurements. The leak localisation methodology consists, first, in generating the set of possible measurements, obtained by Monte Carlo Simulation under a certain leak assumption and considering uncertainty, and second, in falsifying sets of nodes using the correlation with a leak residual model in order to signal a set of possible leaky nodes. The assessment is done by means of generating the confusion matrix with a Monte Carlo approach., This work was partially supported by Spanish Government (MINISTERIO ECNONOMIA Y COMPETITIVIDAD) and FEDER under projects DPI2014-58104-R (HARCRICS), DPI-2013-48243-C2-1-R (ECOCIS), the grant IJCI-2014-2081, the Polytechnic University of Catalunya (UPC), EFFINET grant FP7-ICT-2012-318556 of the European Commission and by the Catalan Agency for Management of University and Research Grants (AGAUR) through the grant 2014PDJ00102., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Optimal management of barcelona water distribution network using non-linear model predictive control

  • Wang, Ye
  • Cembrano, Gabriela
  • Puig, Vicenç
  • Urrea, Maite
  • Romera, Juli
  • Saporta, David
  • Valero, J. G.
  • Quevedo, Joseba
Trabajo presentado al 20th IFAC (International Federation of Automatic Control) World Congress, celebrado en Toulouse (Francia) del 9 al 14 de julio de 2017., This paper presents a non-linear optimal control strategy for the operational management of water distribution networks (WDNs) including both flow and hydraulic head/pressure constraints. The optimal operation of WDNs should guarantee water supply with suitable pressures at all the demand nodes in the network. The challenge for non-linear model predictive control in this context is to compute control strategies for the pumps and valves in a WDN to supply the required demand while optimizing performance goals related to cost and safety. A two-layer scheme is used in order to produce set-points that can be directly sent to the actuators: on-off schedules for pumps and pressure set-points for pressures reducing valves. Finally, the results of applying the proposed control strategy to a portion of the Barcelona real WDN are provided., This work has been partially funded by the European Union through the project EFFINET (ref. FP7-ICT-2011-8-318556), by the Spanish Government and FEDER through the projects CICYT ECOCIS (ref. DPI2013-48243-C2-1-R), CICYT DEOCS (ref. DPI2016-76493-C3-3-R) and CICYT HARCRICS (ref. DPI2014-58104-R)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Leak localization in water distribution networks using model-based Bayesian reasoning

  • Soldevila, Adrià
  • Fernández Cantí, Rosa M.
  • Blesa, Joaquim
  • Tornil-Sin, Sebastian
  • Puig, Vicenç
Trabajo presentado a la 15th European Control Conference (ECC) celebrada en Aalborg (Dinamarca) del 29 de junio al 1 de julio de 2016., This paper presents a new method for leak localization in Water Distribution Networks that uses a model-based approach combined with Bayesian reasoning. Probability density functions in model-based pressure residuals are calibrated off-line for all the possible leak scenarios by using a hydraulic simulator, being leak size uncertainty, demand uncertainty and sensor noise considered. A Bayesian reasoning is applied online to the available residuals to determine the location of leaks present in the Water Distribution Network. A time horizon method combined with the Bayesian reasoning is also proposed to improve the accuracy of the leak localization method. The Hanoi District Metered Area case study is used to illustrate the performance of the proposed approach., This work has been partially funded by Spanish Government (Ministerio de Economia y Competitividad) and FEDER through the Project ECOCIS (Ref. DPI2013-48243-C2-1-R) and Project HARCRICS (Ref. DPI2014-58104-R), and by EFFINET grant FP7-ICT-2012-318556 of the European Commission., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

On the assessment of tree-based and chance-constrained predictive control approaches applied to drinking water networks

  • Grosso Pérez, Juan Manuel|||0000-0002-4300-1500
  • Maestre Torreblanca, José María
  • Ocampo-Martínez, Carlos|||0000-0001-9251-6044
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
Water systems are a challenging problem because of their size and exposure to uncertain influences such as the unknown demands or the meteorological phenomena. In this paper, two different stochastic programming approaches are assessed when controlling a drinking water network: chance-constrained model predictive control (CC-MPC) and tree-based model predictive control (TB-MPC). Under the former approach, the disturbances are modeled as stochastic variables with non-stationary uncertainty description, unbounded support and quasi concave probabilistic distribution. A deterministic equivalent of the related stochastic problem is formulated using Boole’s inequality and a uniform allocation of risk. In the later approach, water demand is modelled as a disturbance rooted tree where branches are formed by the most probable evolutions of the demand. In both approaches, a model predictive controller is used to optimise the expectation of the operational cost of the disturbed system.
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Combining model predictive control with constraint-satisfaction formulation for the operative pumping control in water networks

  • Sun, Congcong
  • Morley, Mark
  • Savic, Dragan
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Cembrano Gennari, Gabriela|||0000-0003-1436-6022
  • Zhang, Zheng
This paper proposes a method to combine linear Model Predictive Control (MPC), a Constraint Satisfaction Problem (CSP) formulation and a Network Aggregation Method (NAM) for the predictive operational control of water pumping in DWNs. The proposed method can produce optimal pumping strategies for complex DWNs in short computation times, while avoiding the need for nonlinear programming techniques to cater for non-linear flow-head equations. The proposed approach is simulated using Epanet to represent the hydraulic DWNs. The D-Town benchmark water network is used as a case study., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Optimal pressure sensor placement in water distribution networks minimizing leak location uncertainty

  • Nejjari Akhi-Elarab, Fatiha|||0000-0001-9118-632X
  • Sarrate Estruch, Ramon|||0000-0002-9979-5899
  • Blesa Izquierdo, Joaquim|||0000-0002-5626-3753
In this paper an optimal sensor placement strategy based on pressure sensitivity matrix analysis and an exhaustive search strategy that maximizes some diagnosis specifications for a water distribution network is presented. An average worst leak expansion distance as a new leak location performance measure has been proposed. This metric is later used to assess the leak location uncertainty provided by a sensor configuration. The method is combined with a clustering technique in order to reduce the size and the complexity of the sensor placement problem. The strategy is successfully applied to determine the location of a set of pressure sensors in a district metered area in the Barcelona water distribution network., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Predictive fault tolerant control for LPV systems using model reference

  • Acevedo Valle, Juan Manuel|||0000-0002-4005-2441
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Tornil Sin, Sebastián|||0000-0003-1799-2192
  • Witczak, Marcin
  • Rotondo, Damiano|||0000-0002-8855-5582
The present work proposes a Fault Tolerant Control (FTC) methodology for non-linear discrete-time systems that can be modeled as Linear Parameter Varying (LPV) systems. The proposed approach relies on the modeling of faults as additional scheduling parameters of the LPV model for the controlled system and it uses a triple loop architecture. The inner control loop is designed by means of the standard H2/H1 control methodologies based on Linear Matrix Inequalities (LMIs). The design takes into account a prespecified set of faults and the ranges of their magnitudes that are wanted to be tolerated and it assumes the availability of on-line fault estimations provided by a Fault Detection and Isolation (FDI) module. The resulting controller tries to compensate the system faults in order to maintain a satisfactory closed-loop dynamic performance, but it does not take into account possible system input and state constraints associated to actuator saturation and other physical limitations. Thus, an intermediate control loop determines the actual compensation feasibility using set invariance theory. And, when it is needed, it applies suitable additive predictive control actions that enlarge the invariant set, trying to assure that the current state remains inside the enlarged invariant set. Finally, an outer loop implements a model reference control that allows reference tracking. The use of the proposed FTC methodology is illustrated through its application to the well-known quadruple tank system benchmark., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

A distributed command governor strategy for the operational control of drinking water networks

  • Tedesco, Francesco
  • Ocampo-Martínez, Carlos|||0000-0001-9251-6044
  • Casavola, Alessandro
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
This paper proposes the application of a distributed command governor (DCG) strategy for the operational control of drinking water networks (DWN). This approach is very suitable to this kind of management problems given the large-scale and complex nature of DWNs, the relevant effect of persistent disturbances (water demands) over the network evolutions and their marginal stability feature. The performance improvement offered by DCG is compared with the consideration of two non-centralized model predictive control (MPC) approaches already proposed for the same management purposes and within the same context. The paper also discusses the effectiveness of all strategies and highlights the advantages of each approach. The Barcelona DWN is considered as the case study for the assessment analysis., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Multi-layer model predictive control of regional water networks: application to the Catalunya case study

  • Sun, Congcong
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Cembrano Gennari, Gabriela|||0000-0003-1436-6022
A multi-layer model predictive control (MPC) scheme with temporal multi-level coordination for regional water networks is proposed. First, a multi-layer control structure resulting from a functional decomposition of water network is briefly presented. Inside each layer, a MPC based controller is used. Between related layers, a temporal multi-level coordination mechanism is used to generate control strategies which consider objectives and time scales of both layers. The proposed approach will be applied to the Catalunya Regional Water Network. The paper presents the results based on an aggregate model of this network., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Model-based monitoring techniques for leakage localization in distribution water networks

  • Meseguer Amela, Jordi
  • Mirats Tur, Josep Maria
  • Cembrano Gennari, Gabriela|||0000-0003-1436-6022
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
This is an open access article under the CC BY-NC-ND license, This paper describes an integrated model-based monitoring framework for leakage localization in district-metered areas (DMA) of water distribution networks, which takes advantage of the availability of a hydraulic model of the network. The leakage localization methodology is based on the use of flow and pressure sensors at the DMA inlets and a limited number of pressure sensors deployed inside the DMA. The placement of these sensors has been computed using an optimal sensor placement method based on a Genetic Algorithm optimization, which integrates the direct modelling approach (simulation) used to identify the location of leaks. The application of the resulting monitoring framework in a certain DMA of the Barcelona distribution network is provided and discussed using simulated leakage scenarios. The obtained results show that leakage detection and localisation may be performed efficiently, reducing the required time for detection/localization, by following a simple procedure., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Sensor placement for leak monitoring in drinking water networks combining clustering techniques and a semi-exhaustive search

  • Sarrate Estruch, Ramon|||0000-0002-9979-5899
  • Blesa Izquierdo, Joaquim|||0000-0002-5626-3753
  • Nejjari Akhi-Elarab, Fatiha|||0000-0001-9118-632X
This paper presents an optimal sensor placement strategy based on pressure sensitivity matrix analysis and a semi-exhaustive search strategy that maximizes some diagnosis specifications for water distribution networks. A mean average worst leak expansion distance has been proposed as a new leak location performance measure. The approach is combined with a clustering technique in order to reduce the size and the complexity of the sensor placement problem. The strategy is successfully applied to determine the location of a set of pressure sensors in a district metered area (DMA) in the Barcelona water distribution network (WDN)., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Coordinating multi-layer MPC for complex water systems

  • Sun, Congcong
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Cembrano Gennari, Gabriela|||0000-0003-1436-6022
In this paper, coordinating technique for the multi-layer model predictive control (MPC) of complex water network is proposed. A multi-layer topology structure resulting from a functional decomposition of water network is briefly presented. Inside each layer, a MPC based controller is used. Between the related two layers, a multi-layer coordinating mechanism is provided to generate control strategies which consider objectives and time scales of both layers. Optimal Path Method (OPM) is used to estimate aggregated water price for the whole layer. The case study is the Catalunya Regional Water Network. Simulation results based on an aggregate model of this network are provided., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Distributed control of drinking water networks using population dynamics: Barcelona case study

  • Barreiro Gómez, Julián
  • Quijano Silva, Nicanor
  • Ocampo-Martínez, Carlos|||0000-0001-9251-6044
Large-scale network systems involve a large number of variables, making the design of real-time controllers challenging. A distributed controller design allows to reduce computational requirements since tasks may be divided into different subsystems, making possible to guarantee real-time processing. This paper proposes a constrained optimization based distributed control design by applying a novel population and masses dynamics approach. The distributed controller design is applied to the Barcelona Drinking Water Network (DWN) in order to illustrate its effectiveness in the control performance., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Economic MPC for the management of drinking water networks

  • Grosso Pérez, Juan Manuel|||0000-0002-4300-1500
  • Ocampo-Martínez, Carlos|||0000-0001-9251-6044
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Limón Marruedo, Daniel
  • Pereira, Mario
This paper addresses the management of drinking water networks (DWNs) regarding a multi-objective cost function by means of economically-oriented model predictive control (EMPC) strategies. Specifically, assuming the water demand and the energy price as periodically time-varying signals, this paper shows that the EMPC framework is flexible to enhance the control of DWNs without relying on hierarchical control schemes that require the use of real-time optimisers (RTO) or steady-state target optimisers (SSTO) in an upper layer. Four different MPC strategies are discussed in this paper: a hierarchical two-layer approach, a standard EMPC where the multi-objective cost function is optimised directly, and two different modifications of the latter, which are meant to overcome possible feasibility losses in the presence of changing operating patterns. The discussed schemes are tested andcompared by means of a case study taken from a part of the Barcelona DWN., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Receding horizon control of hybrid linear delayed systems: application to sewer networks

  • Joseph Duran, Bernat
  • Ocampo-Martínez, Carlos|||0000-0001-9251-6044
  • Cembrano Gennari, Gabriela|||0000-0003-1436-6022
A control-oriented hybrid linear model for water transport in sewer networks is proposed as a suitable framework for the computation of real-time controllers for the minimization of flooding in presence of heavy-rain events. The model is based on individual network elements (sewers, gates, weirs and tanks) and does not rely on topological simplifications, thus providing a better description of the hydrological and hydraulic phenomena than in similar works. Using a generic form of a hybrid linear model, a simple matrix-based procedure for the formulation and solution of an optimal control problem is also presented. This procedure is applied to the sewer network model for the case study of a part of the Barcelona sewer network in a receding horizon control strategy, showing the effectiveness of the proposed control approach., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

On the comparison of predictive control and command governor approaches for operational management of drinking water networks: a case study

  • Tedesco, Francesco
  • Ocampo-Martínez, Carlos|||0000-0001-9251-6044
  • Cassavola, Alessandro
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
This paper evaluates the application of command governor (CG) strategy for the operational control of drinking water networks (DWN) given their large-scale and complex nature, the permanent and relevant effect of the disturbances (water demands) and their marginal stability feature. Moreover, the performance improvement offered by CG is compared with the application of model predictive control for the same management purposes and in the same context. The paper also discusses the effectiveness of both strategies and highlights the advantages of each approach. The Barcelona DWN is considered as case study for the undertaken assessment analysis., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Making non-centralized a model predictive control scheme by using distributed Smith dynamics

  • Barreiro Gómez, Julián
  • Obando, Germán
  • Ocampo-Martínez, Carlos|||0000-0001-9251-6044
  • Quijano Silva, Nicanor
This paper proposes a non--centralized Model Predictive Control (MPC) scheme for a system comprised by several sub-systems. Operational constraints for each subsystem are considered as well as a single coupled constraint on the control inputs that models a limitation of the emph{resource} supplied by the controller. If the underlying optimization problem is of large-scale nature, traditional MPC suffers from computational burden issues. A cause of this problem is the requirement of having centralized information to guarantee that the computed control actions satisfy the coupled constraint. In this work, a traditional MPC is made non--centralized by means of a strategy based on distributed population dynamics. The proposed methodology divides the problem into several local MPC controllers that coordinate their decisions by using a communication network without the need of a centralized scheme. It is proved that this methodology provides an optimal solution that satisfies both the operational constraints of each sub--system, and the coupled constraint of the control signals. Finally, the proposed method is compared with a traditional centralized MPC in an industrial problem that involves several continuously stirred tank reactors., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Accuracy assessment of leak localisation method depending on available measurements

  • Pérez Magrané, Ramon|||0000-0002-9216-4234
  • Cugueró Escofet, Miquel Àngel|||0000-0001-9525-1790
  • Cugueró Escofet, Josep|||0000-0002-7724-7808
  • Sanz Estapé, Gerard|||0000-0003-2821-9912
Model-based leak localization methods are currently developed and applied to real cases. The performance and success of such methods depend highly both on models [Pérez et al. (2011a)] and the measurements available. The optimal distribution of sensors is a good approach [Pérez et al. (2009)]. Nevertheless, in a huge network with hundreds of District Metered Area (DMA) the question of how the methodology can help with the sensors already installed in the network arises. This paper presents a sequence of steps to assess the performance of a given leakage localization methodology [Quevedo et al. (2011)]. Initially, flow sensors at the control points are used, and inner pressure sensors are added sequentially, since flows are often measured in the network control points and pressure sensors are a common choice for new installed sensors. Using the available sensors information, an investment-precision relationship indicator is proposed. The assessment is applied to a real network situated in Barcelona., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Model-free control for wind farms using a gradient estimation-based algorithm

  • Barreiro Gómez, Julián
  • Ocampo-Martínez, Carlos|||0000-0001-9251-6044
  • Bianchi, Fernando Daniel|||0000-0001-7332-6501
  • Quijano Silva, Nicanor
Wind turbines working close to other turbines experience interactions that affect the power production. These interactions arise as a consequence of wakes caused by upstream wind turbines. In order to achieve a more effective and precise control of the power generated by wind farms, the control strategy must consider these interactions. However, the phenomena involved in wake effects are complex especially in cases of large number of turbines. This paper presents the implementation of a gradient estimation-based algorithm as a model-free control for two different control schemes aimed to maximize the energy capture of a wind farm. One control is centralized, leaving to a supervisor the task of command computation and the other topology is decentralized, distributing the performing generation among wind turbines. This latter scheme aims to increase the reliability of the wind farm operation by reducing the communications needed to fulfill the objective of maximizing energy capture. Both control schemes are evaluated by simulation in the case of three-turbine wind farm., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

MPC design based on a DBN reliability model: Application to drinking water networks

  • Salazar Cortés, Jean Carlo|||0000-0003-3271-6647
  • Weber, Philipe
  • Sarrate Estruch, Ramon|||0000-0002-9979-5899
  • Theilliol, Didier
  • Nejjari Akhi-Elarab, Fatiha|||0000-0001-9118-632X
This paper presents a Model Predictive Control (MPC) strategy taking into account system and component reliability for drinking water networks. The objective is to deal from an availability point of view with a closed-loop system combining a deterministic part related to the system dynamics and a stochastic part related to the actuators and system reliability. The main contribution of this work consists in integrating the reliability assessment computed on-line using a Dynamic Bayesian Network (DBN) into the MPC algorithm., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Actuator-fault detection and isolation based on interval observers and invariant sets

  • Xu, Feng
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Ocampo-Martínez, Carlos|||0000-0001-9251-6044
  • Stoican, Florin
  • Olaru, Sorin
This paper proposes an interval observer-based actuator fault detection and isolation (FDI) approach. An interval observer matching the healthy system mode is designed to monitor the system. When the system is in different modes, state or output interval vectors predicted by the interval observer manifest different dynamical behaviors. To guarantee reliable FDI, a collection of invariant set-based FDI conditions are established. Under these conditions, actuator faults can be accurately detected and isolated during the transition between different modes. At the end, the effectiveness of this proposed approach is presented by using a numerical example.
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Optimal pressure sensor placement for leak localisation using a relaxed isolation index : application to the Barcelona water network

  • Cugueró Escofet, Miquel Àngel|||0000-0001-9525-1790
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Quevedo Casín, Joseba Jokin|||0000-0002-7827-2896
  • Blesa Izquierdo, Joaquim|||0000-0002-5626-3753
Water distribution networks are large complex systems that are affected by leaks, which often entail high costs and may severely jeopardize the overall water distribution performance. Successful leak localisation is paramount in order to minimize the impact of these leaks when occurring. Sensor placement is a key issue in the leak localisation process, since the overall performance and success of the leak isolation method highly depends on the choice of the sensors gathering data from the network. Common problems when leak isolating in large scale highly-gridded real water distribution networks include leak mislabelling and large isolation areas obtention due to similarity of the measurements, which may be caused by topological issues and led to incomplete coverage of the whole network. The sensor placement strategy may minimize these undesired effects by setting the sensor placement optimisation problem with the appropriate assumptions e.g. geographically cluster alike leak behaviors, taking into account real aspects of the practical application such as the acceptable isolation distance. Here, a sensor placement methodology considering these assets and a general sensor distribution assessment method for leak diagnosis in water distribution systems is presented for a real District Metered Area (DMA) located within the Barcelona water distribution network., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Decentralized control for urban drainage systems via population dynamics : Bogota case study

  • Barreiro Gómez, Julián
  • Obando, Germán
  • Riaño Briceño, Gerardo
  • Quijano Silva, Nicanor
  • Ocampo-Martínez, Carlos|||0000-0001-9251-6044
Control of Urban Drainage Systems (UDS) is studied for cases in which the distribution of run–off through the channels of a system is inefficient, i.e. when the capacity of some structures is not used optimally. In this paper, a decentralized population-dynamics-based control for UDS is presented, particularly using the replicator and projection dynamics. For the design, a methodology to make a partitioning of the system is introduced, and the design of a population–dynamics–based control per each partition is proposed. Moreover, a stability analysis of the closed–loop system is made by using passivity theory. Finally, simulation results show the proposed approach performance in a segment of the Bogota stormwater UDS case study., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

On the modeling and real-time control of urban drainage systems: A survey

  • García Gutiérrez, Luis Antonio
  • Escobar, Eduardo
  • Barreiro Gómez, Julián
  • Quijano Silva, Nicanor
  • Ocampo-Martínez, Carlos|||0000-0001-9251-6044
  • Téllez, Duván
Drainage networks are complex systems composed by several processes including recollection, transport, storing, treatment, and releasing the water to a receiving environment. The way Urban Drainage Systems (UDS) manage wastewater is through the convenient handling of active elements such as gates (redirection and/or retention), storing tanks, and pumping stations, when needed. Therefore, modeling and control of UDS basically consists in knowing and representing the (dynamical) behavior of these elements and managing them properly in order to achieve a given set of control objectives, such as minimization of flooding in streets or maximization of treated wastewater in the system. Given the large number of elements composing an UDS and the interaction between them, management and control strategies may depend on highly complex system models, which implies the explicit difficulty for designing real-time control (RTC) strategies. This paper makes a review of the models used to describe, simulate, and control UDS, proposes a revision of the techniques and strategies commonly used for the control UDS, and finally compares several control strategies based on a case study., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

A multiobjective-based switching topology for hierarchical model predictive control applied to a hydro-power valley

  • Nuñez Vicencio, Alfredo
  • Ocampo-Martínez, Carlos|||0000-0001-9251-6044
  • De Schutter, Bart
  • Valencia, Felipe
  • López, José D.
  • Espinosa, Jairo
In a Hierarchical Model Predictive Control (H-MPC) framework, this paper explores suitable time-variant structures for the hierarchies of different local MPC controllers. The idea is to adapt to different operational conditions by changing the importance of the local controllers. This is done by defining the level of the hierarchy they belong to, and solving within each level the local MPC problem using the information provided by the higher levels at the current time step and the predicted information from the lower levels obtained in the previous time step. As selecting a hierarchy results in a combinatorial optimization problem, it is explicitly solved for a limited number of relevant topologies only and then the switching between topologies is defined with a multiobjective optimizer, so as to decide the best H-MPC scheme according to the expected performance. A comparison with fixed-topology H-MPC controllers is done, showing the effectiveness of the proposed approach for the power control of a hydro-power valley., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Two-layer scheduling scheme for pump stations

  • Sun, Congcong
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Cembrano Gennari, Gabriela|||0000-0003-1436-6022
In this paper, a two-layer scheduling scheme for pump stations in a water distribution network has been proposed. The upper layer, which works in one-hour sampling time, uses Model Predictive Control (MPC) to produce continuous flow set-points for the lower layer. While in the lower layer, a scheduling algorithm has been used to translate the continuous flow set-points to a discrete (ON-OFF) control operation sequence of the pump stations with the constraints that pump stations should draw the same amount of water as the continuous flow set-points provided by the upper layer. The tuning parameters of such algorithm are the lower layer control sampling period and the number of parallel pumps in the pump station. The proposed method has been tested in the Richmond case study., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Constrained distributed optimization based on population dynamics

  • Barreiro Gómez, Julián
  • Quijano Silva, Nicanor
  • Ocampo-Martínez, Carlos|||0000-0001-9251-6044
This paper proposes a novel methodology for solving constrained optimization problems in a distributed way, inspired by population dynamics and adding dynamics to the population masses. The proposed methodology divides the problem into smaller problems, whose feasible regions vary over time achieving an agreement to solve the global problem. The methodology also guarantees attraction to the feasible region and allows to have few changes in the decision-making design, when the network suffers the addition or removal of nodes. Simulation results are presented in order to illustrate several cases., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Combining CSP and MPC for the operational control of water networks: Application to the Richmond case study

  • Sun, Congcong
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Cembrano Gennari, Gabriela|||0000-0003-1436-6022
This paper presents the combination of linear Model Predictive Control (MPC) with Constraint Satisfaction Problem (CSP) for the operational control of drinking water networks. The methodology has been divided into two functional layers: First, a CSP algorithm is used to transfer non-linear pressure equations of drinking water networks (DWNs) into linear constraints, which can enclose feasible solution of the hydraulic non-linear problem during the optimizing process. Then, a linear MPC with added linear constraints is solved to generate control strategies which consider control objectives. Finally, the proposed approach is simulated using Epanet to represent the real DWNs. PLIO, which is a generic operational tool for controlling water networks that uses non-linear MPC, is used for validation. The Richmond water system is used as a case study., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Sensor placement for leak location in water distribution networks using the leak signature space

  • Casillas Ponce, Myrna Violeta
  • Garza Castañón, Luís Eduardo
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
In this paper, a sensor placement approach to improve the leak location in water distribution networks is proposed. The sensor placement problem is formulated as an integer optimization problem where the criterion to minimize is the number of overlapping signature domains computed from the leak signature space (LSS) representation. A stochastic optimization process is proposed to solve this problem, based on either a Genetic Algorithms (GA) or a Particle Swarm Optimization (PSO) approach. Experiments on two different DMAs are used to evaluate the performance of the resolution methods as well as the effciency achieved in the leak location when using the sensor placement results.
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Assessment of a leak localization algorithm in water networks under demand uncertainty

  • Cugueró Escofet, Josep|||0000-0002-7724-7808
  • Blesa Izquierdo, Joaquim|||0000-0002-5626-3753
  • Pérez Magrané, Ramon|||0000-0002-9216-4234
  • Cugueró Escofet, Miquel Àngel|||0000-0001-9525-1790
  • Sanz Estapé, Gerard|||0000-0003-2821-9912
The performance and success of model-based leak localization methods applied to water networks highly depends on the uncertainty of the system considered. One of the main sources of uncertainty in these networks are the demands in the network nodes. This work developes a methodology to evaluate the ability of an existing algorithm to locate leaks in the presence of bounded uncertainty in the node demands. Zonotopic sets are found to be specially suited to bound nodal demand uncertainty. Two consistent approaches to evaluate the effect of demand uncertainty on the decision result are shown: a Montecarlo approach and a Montecarlo combined with zonotope analysis approach. The methodology is presented using a simplified version of an existing leak location algorithm applied to an illustrative network to stress comprehension., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Optimal sensor placement for leak location in water distribution networks using genetic algorithms

  • Casillas, Myrna V.
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Garza Castañón, Luís Eduardo
  • Rosich, Albert
In this paper, a new approach for sensor placement in water distribution networks (WDN) is proposed. The sensor placement problem is formulated as an integer optimization problem. The optimization criterion consists in minimizing the number of non-isolable leaks according to the isolability criteria introduced. Because of the non-linear integer and largescale nature of the resulting optimization problem, genetic algorithms (GA) are used as solution approach. To validate the results obtained, they are compared with exhaustive search methods with higher computational cost proving that GA allow to find near-optimal solutions with less computational load. The proposed sensor placement algorithm is combined with a projection-based isolation scheme. However, the proposed methodology does not depend on the isolation method chosen by the user and it could be easily adapted to any other isolation scheme. Experiments on a real network allow to evaluate the performance of such approach.
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Real-time monitoring and control for efficient management of drinking water networks: Barcelona case study

  • Cembrano Gennari, Gabriela|||0000-0003-1436-6022
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Ocampo-Martínez, Carlos|||0000-0001-9251-6044
  • Quevedo Casín, Joseba Jokin|||0000-0002-7827-2896
  • Mirats Tur, Josep Maria
  • Meseguer Amela, Jordi
  • Ariño Tarrago, Ramon
  • López Martínez, Silvia
Drinking water utilities in urban areas are facing new challenges in their real-time operation: limited water resources, intensive energy requirements, a growing population, a costly and ageing infrastructure, increasingly stringent regulations, and increased attention towards the environmental impact of water use. The efficient use of resources is becoming a priority for water managers and the recent advances in ICT technologies can provide solutions to this end. Real-time management in water networks may be considered as a process comprising two different levels: (i) Monitoring, which is concerned with the observation and estimation of the current state of a system and the detection/diagnosis of abnormal situations. It is achieved through sensors and communications technology, together with mathematical models; and (ii) Control, related to computing and applying the best admissible control strategies for network actuators. Optimal control seeks to optimize a given set of operational goals related to the network performance, such as efficiency in resource use, environmental impact, etc. Real-time monitoring and control techniques can significantly improve the use of water and energy resources in water networks. This paper addresses the developments of the European project EFFINET, which proposes a novel integrated water resource management system based on advanced ICT technologies of automation and telecommunications for improving the efficiency of drinking water networks in terms of water use, energy consumption, water loss minimization, and water quality guarantees by addressing the real-time monitoring and control levels., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Sensor placement for leak detection and location in water distribution networks

  • Sarrate Estruch, Ramon|||0000-0002-9979-5899
  • Blesa Izquierdo, Joaquim|||0000-0002-5626-3753
  • Nejjari Akhi-Elarab, Fatiha|||0000-0001-9118-632X
  • Quevedo Casín, Joseba Jokin|||0000-0002-7827-2896
The performance of a leak detection and location algorithm depends on the set of measurements that are available in the network. This works presents and optimization strategy that maximizes the leak diagnosability performance of the network. The goal is to characterize and determine a sensor configuration that guarantees a maximum degree of disnosability while the sensor configuration cost satifies a budgetary constraint. To efficiently handle the complexity of the distribuion networl an efficient branch and bound search strategy based on a strucutrual model is used. However, in order to reduce even more the size and the complexity of the problem the present work proposes to combine this methodology with clustering techniques. The strategy developed in this work is successfully applied to determine the optimal set of pressure sensors that should be installed to a District Metered Area in the Baarcelona Water Distribution Network., Peer Reviewed, Award-winning
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Uncertainty effect on leak localisation in a DMA

  • Pérez Magrané, Ramon|||0000-0002-9216-4234
  • Cugueró Escofet, Josep|||0000-0002-7724-7808
  • Blesa Izquierdo, Joaquim|||0000-0002-5626-3753
  • Cugueró Escofet, Miquel Àngel|||0000-0001-9525-1790
  • Sanz, Gerard
The leak localisation methodologies based on data and models are affected by both uncertainties in the model and in the measurements. This uncertainty should be quantified so that its effect on the localisation methods performance can be estimated. In this paper, a model-based leak localisation methodology is applied to a real District Metered Area using synthetic data. In the generation process of the data, uncertainty in demands is taken into account. This uncertainty was estimated so that it can justify the uncertainty observed in the real measurements. The leak localisation methodology consists, first, in generating the set of possible measurements, obtained by Monte Carlo Simulation under a certain leak assumption and considering uncertainty, and second, in falsifying sets of nodes using the correlation with a leak residual model in order to signal a set of possible leaky nodes. The assessment is done by means of generating the confusion matrix with a Monte Carlo approach., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Gaussian-process-based demand forecasting for predictive control of drinking water networks

  • Wang, Ye|||0000-0003-1395-1676
  • Ocampo-Martínez, Carlos|||0000-0001-9251-6044
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Quevedo Casín, Joseba Jokin|||0000-0002-7827-2896
This paper focuses on water demand forecasting for predictive control of Drinking Water Networks (DWN) in the short term by using Gaussian Process (GP). For the predictive control strategy, system states in a finite horizon are generated by a DWN model and demands are regarded as system disturbances. The goal is to provide a demand estimation within a given confidence interval. For the sake of obtaining a desired forecasting performance, the forecasting process is carried out in two parts: the expected part is forecasted by Double-Seasonal Holt-Winters (DSHW) method and the stochastic part is forecasted by GP method. The mean value of water demand is firstly estimated by DSHW while GP provides estimations within a confidence interval. GP is applied with random inputs to propagate uncertainty at each step. Results of the application of the proposed approach to a real case study based on the Barcelona DWN have shown that the general goal has been successfully reached., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Decentralised fault diagnosis of large-scale systems: application to water transport networks

  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Ocampo-Martínez, Carlos|||0000-0001-9251-6044
In this paper, a decentralised fault diagnosis approach for large-scale systems is proposed. This approach is based on obtaining a set of local diagnosers using the analytical redundancy relation (ARRs) approach. The proposed approach starts with obtaining the set of ARRs of the system yielding into an equivalent graph. From that graph, the graph partitioning problem is solved obtaining a set of ARRs for each local diagnoser. Finally, a decentralised fault diagnosis strategy is proposed and applied over the resultant set of partitions and ARRs. In order to illustrate the application of the proposed approach, a case study based on the Barcelona drinking water network (DWN) is used.
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Robustness analysis of sensor placement for leak detection and location under uncertain operating conditions

  • Blesa Izquierdo, Joaquim|||0000-0002-5626-3753
  • Nejjari Akhi-Elarab, Fatiha|||0000-0001-9118-632X
  • Sarrate Estruch, Ramon|||0000-0002-9979-5899
Some pressure sensor placement methods for leak detection and location in water distribution networks are based on the pressure sensitivity matrix analysis. This matrix depends on the network demands, which are nondeterministic, and the leak magnitudes, which are unknown. In this paper, the robustness of a sensor placement methodology against the fault sensitivity matrix uncertainty is studied. The robustness study is illustrated by means of a small academic network as well as a district metered area in the Barcelona water distribution network. Results reveal that this uncertainty should be taken into account in the sensor placement methodology., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Robust model predictive control based on Gaussian processes: application to drinking water networks

  • Wang, Ye|||0000-0003-1395-1676
  • Ocampo-Martínez, Carlos|||0000-0001-9251-6044
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
In this paper, a controller design based on robust Model Predictive Control (MPC) and Gaussian Processes (GP) for incorporating the disturbance forecasting has been proposed. Using a probabilistic system representation, the state trajectories considering the influence of disturbances can be obtained through the uncertainty propagation by using GP. Therefore, the worst-case state trajectories evolution over the MPC prediction horizon can be determined, which are potentially used by including them into the MPC cost function and constraints. For the purpose of inspecting the performance of proposed controller, it has been compared with a certainequivalent MPC and a chance-constrained MPC. Results of the application the proposed approach to Barcelona Drinking Water Network (DWN) have shown the effectiveness of the approach and comparison results with the other considered MPC approaches have shown the advantages and drawbacks of each approach., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Leak localization in water distribution networks using pressure residuals and classifiers

  • Ferrandez-Gamot, Lise
  • Bousson, Pierre
  • Blesa Izquierdo, Joaquim|||0000-0002-5626-3753
  • Tornil Sin, Sebastián|||0000-0003-1799-2192
  • Puig Cayuela, Vicenç|||0000-0002-6364-6429
  • Douviella, Eric
  • Soldevila Coma, Adrià
In order to take into account the scarcity of the water resource and the increasing of the population, the management of drinking water networks has to be improved with the use of new tools and actions that allows fighting against wasting water. The monitoring of drinking water networks is based on the use of sensors to locate malfunctions (leaks, quality/contamination events, etc.). Practical implementation has to be carried out by optimizing the placement of the number of sensors and improving the detection and localization of malfunctions. Techniques for the detection and localization of leaks have been proposed in the last years based on the evaluation of residuals obtained by means of the comparison between the measurements obtained by the sensors and the values obtained by simulating the water network in a leak free scenario. In this paper, a data-driven approach based on the use of statistical classifiers working in the residual space is proposed for leak localization. The classifiers are trained using leak data scenarios in all the nodes of the network considering uncertainty in demand distribution, additive noise in sensors and leak magnitude. Finally, the proposed approach is tested using the well-known Hanoi network benchmark., In order to take into account the scarcity of the water resource and the increasing of the population, the management of drinking water networks has to be improved with the use of new tools and actions that allows fighting against wasting water. The monitoring of drinking water networks is based on the use of sensors to locate malfunctions (leaks, quality/contamination events, etc.). Practical implementation has to be carried out by optimizing the placement of the number of sensors and improving the detection and localization of malfunctions. Techniques for the detection and localization of leaks have been proposed in the last years based on the evaluation of residuals obtained by means of the comparison between the measurements obtained by the sensors and the values obtained by simulating the water network in a leak free scenario. In this paper, a data-driven approach based on the use of statistical classifiers working in the residual space is proposed for leak localization. The classifiers are trained using leak data scenarios in all the nodes of the network considering uncertainty in demand distribution, additive noise in sensors and leak magnitude. Finally, the proposed approach is tested using the well-known Hanoi network benchmark.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Robust model predictive control based on Gaussian processes: application to drinking water networks

  • Wang, Ye
  • Ocampo-Martínez, Carlos
  • Puig Cayuela, Vicenç
In this paper, a controller design based on robust Model Predictive Control (MPC) and Gaussian Processes (GP) for incorporating the disturbance forecasting has been proposed. Using a probabilistic system representation, the state trajectories considering the influence of disturbances can be obtained through the uncertainty propagation by using GP. Therefore, the worst-case state trajectories evolution over the MPC prediction horizon can be determined, which are potentially used by including them into the MPC cost function and constraints. For the purpose of inspecting the performance of proposed controller, it has been compared with a certainequivalent MPC and a chance-constrained MPC. Results of the application the proposed approach to Barcelona Drinking Water Network (DWN) have shown the effectiveness of the approach and comparison results with the other considered MPC approaches have shown the advantages and drawbacks of each approach., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Sensor placement for leak detection and location in water distribution networks

  • Sarrate Estruch, Ramon
  • Blesa Izquierdo, Joaquim
  • Nejjari Akhi-Elarab, Fatiha
  • Quevedo Casín, Joseba Jokin
The performance of a leak detection and location algorithm depends on the set of measurements that are available in the network. This works presents and optimization strategy that maximizes the leak diagnosability performance of the network. The goal is to characterize and determine a sensor configuration that guarantees a maximum degree of disnosability while the sensor configuration cost satifies a budgetary constraint. To efficiently handle the complexity of the distribuion networl an efficient branch and bound search strategy based on a strucutrual model is used. However, in order to reduce even more the size and the complexity of the problem the present work proposes to combine this methodology with clustering techniques. The strategy developed in this work is successfully applied to determine the optimal set of pressure sensors that should be installed to a District Metered Area in the Baarcelona Water Distribution Network., Peer Reviewed, Award-winning, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Constrained distributed optimization based on population dynamics

  • Barreiro Gómez, Julián
  • Quijano Silva, Nicanor
  • Ocampo-Martínez, Carlos
This paper proposes a novel methodology for solving constrained optimization problems in a distributed way, inspired by population dynamics and adding dynamics to the population masses. The proposed methodology divides the problem into smaller problems, whose feasible regions vary over time achieving an agreement to solve the global problem. The methodology also guarantees attraction to the feasible region and allows to have few changes in the decision-making design, when the network suffers the addition or removal of nodes. Simulation results are presented in order to illustrate several cases., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Model-based monitoring techniques for leakage localization in distribution water networks

  • Meseguer Amela, Jordi
  • Mirats Tur, Josep Maria
  • Cembrano Gennari, Gabriela
  • Puig Cayuela, Vicenç
This is an open access article under the CC BY-NC-ND license, This paper describes an integrated model-based monitoring framework for leakage localization in district-metered areas (DMA) of water distribution networks, which takes advantage of the availability of a hydraulic model of the network. The leakage localization methodology is based on the use of flow and pressure sensors at the DMA inlets and a limited number of pressure sensors deployed inside the DMA. The placement of these sensors has been computed using an optimal sensor placement method based on a Genetic Algorithm optimization, which integrates the direct modelling approach (simulation) used to identify the location of leaks. The application of the resulting monitoring framework in a certain DMA of the Barcelona distribution network is provided and discussed using simulated leakage scenarios. The obtained results show that leakage detection and localisation may be performed efficiently, reducing the required time for detection/localization, by following a simple procedure., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

A multiobjective-based switching topology for hierarchical model predictive control applied to a hydro-power valley

  • Nuñez Vicencio, Alfredo
  • Ocampo-Martínez, Carlos
  • De Schutter, Bart
  • Valencia, Felipe
  • López, José D.
  • Espinosa, Jairo
In a Hierarchical Model Predictive Control (H-MPC) framework, this paper explores suitable time-variant structures for the hierarchies of different local MPC controllers. The idea is to adapt to different operational conditions by changing the importance of the local controllers. This is done by defining the level of the hierarchy they belong to, and solving within each level the local MPC problem using the information provided by the higher levels at the current time step and the predicted information from the lower levels obtained in the previous time step. As selecting a hierarchy results in a combinatorial optimization problem, it is explicitly solved for a limited number of relevant topologies only and then the switching between topologies is defined with a multiobjective optimizer, so as to decide the best H-MPC scheme according to the expected performance. A comparison with fixed-topology H-MPC controllers is done, showing the effectiveness of the proposed approach for the power control of a hydro-power valley., Peer Reviewed, Postprint (author’s final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

A distributed command governor strategy for the operational control of drinking water networks

  • Tedesco, Francesco
  • Ocampo-Martínez, Carlos
  • Casavola, Alessandro
  • Puig Cayuela, Vicenç
This paper proposes the application of a distributed command governor (DCG) strategy for the operational control of drinking water networks (DWN). This approach is very suitable to this kind of management problems given the large-scale and complex nature of DWNs, the relevant effect of persistent disturbances (water demands) over the network evolutions and their marginal stability feature. The performance improvement offered by DCG is compared with the consideration of two non-centralized model predictive control (MPC) approaches already proposed for the same management purposes and within the same context. The paper also discusses the effectiveness of all strategies and highlights the advantages of each approach. The Barcelona DWN is considered as the case study for the assessment analysis., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Sensor placement for leak location in water distribution networks using the leak signature space

  • Casillas Ponce, Myrna Violeta
  • Garza Castañón, Luís Eduardo
  • Puig Cayuela, Vicenç
In this paper, a sensor placement approach to improve the leak location in water distribution networks is proposed. The sensor placement problem is formulated as an integer optimization problem where the criterion to minimize is the number of overlapping signature domains computed from the leak signature space (LSS) representation. A stochastic optimization process is proposed to solve this problem, based on either a Genetic Algorithms (GA) or a Particle Swarm Optimization (PSO) approach. Experiments on two different DMAs are used to evaluate the performance of the resolution methods as well as the effciency achieved in the leak location when using the sensor placement results., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Predictive fault tolerant control for LPV systems using model reference

  • Acevedo Valle, Juan Manuel
  • Puig Cayuela, Vicenç
  • Tornil Sin, Sebastián
  • Witczak, Marcin
  • Rotondo, Damiano
The present work proposes a Fault Tolerant Control (FTC) methodology for non-linear discrete-time systems that can be modeled as Linear Parameter Varying (LPV) systems. The proposed approach relies on the modeling of faults as additional scheduling parameters of the LPV model for the controlled system and it uses a triple loop architecture. The inner control loop is designed by means of the standard H2/H1 control methodologies based on Linear Matrix Inequalities (LMIs). The design takes into account a prespecified set of faults and the ranges of their magnitudes that are wanted to be tolerated and it assumes the availability of on-line fault estimations provided by a Fault Detection and Isolation (FDI) module. The resulting controller tries to compensate the system faults in order to maintain a satisfactory closed-loop dynamic performance, but it does not take into account possible system input and state constraints associated to actuator saturation and other physical limitations. Thus, an intermediate control loop determines the actual compensation feasibility using set invariance theory. And, when it is needed, it applies suitable additive predictive control actions that enlarge the invariant set, trying to assure that the current state remains inside the enlarged invariant set. Finally, an outer loop implements a model reference control that allows reference tracking. The use of the proposed FTC methodology is illustrated through its application to the well-known quadruple tank system benchmark., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Combining CSP and MPC for the operational control of water networks: Application to the Richmond case study

  • Sun, Congcong
  • Puig Cayuela, Vicenç
  • Cembrano Gennari, Gabriela
This paper presents the combination of linear Model Predictive Control (MPC) with Constraint Satisfaction Problem (CSP) for the operational control of drinking water networks. The methodology has been divided into two functional layers: First, a CSP algorithm is used to transfer non-linear pressure equations of drinking water networks (DWNs) into linear constraints, which can enclose feasible solution of the hydraulic non-linear problem during the optimizing process. Then, a linear MPC with added linear constraints is solved to generate control strategies which consider control objectives. Finally, the proposed approach is simulated using Epanet to represent the real DWNs. PLIO, which is a generic operational tool for controlling water networks that uses non-linear MPC, is used for validation. The Richmond water system is used as a case study., Peer Reviewed, Postprint (author’s final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Optimal pressure sensor placement in water distribution networks minimizing leak location uncertainty

  • Nejjari Akhi-Elarab, Fatiha
  • Sarrate Estruch, Ramon
  • Blesa Izquierdo, Joaquim
In this paper an optimal sensor placement strategy based on pressure sensitivity matrix analysis and an exhaustive search strategy that maximizes some diagnosis specifications for a water distribution network is presented. An average worst leak expansion distance as a new leak location performance measure has been proposed. This metric is later used to assess the leak location uncertainty provided by a sensor configuration. The method is combined with a clustering technique in order to reduce the size and the complexity of the sensor placement problem. The strategy is successfully applied to determine the location of a set of pressure sensors in a district metered area in the Barcelona water distribution network., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

On the comparison of predictive control and command governor approaches for operational management of drinking water networks: a case study

  • Tedesco, Francesco
  • Ocampo-Martínez, Carlos
  • Cassavola, Alessandro
  • Puig Cayuela, Vicenç
This paper evaluates the application of command governor (CG) strategy for the operational control of drinking water networks (DWN) given their large-scale and complex nature, the permanent and relevant effect of the disturbances (water demands) and their marginal stability feature. Moreover, the performance improvement offered by CG is compared with the application of model predictive control for the same management purposes and in the same context. The paper also discusses the effectiveness of both strategies and highlights the advantages of each approach. The Barcelona DWN is considered as case study for the undertaken assessment analysis., Peer Reviewed, Postprint (author’s final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

On the modeling and real-time control of urban drainage systems: A survey

  • García Gutiérrez, Luis Antonio
  • Escobar, Eduardo
  • Barreiro Gómez, Julián
  • Quijano Silva, Nicanor
  • Ocampo-Martínez, Carlos
  • Téllez, Duván
Drainage networks are complex systems composed by several processes including recollection, transport, storing, treatment, and releasing the water to a receiving environment. The way Urban Drainage Systems (UDS) manage wastewater is through the convenient handling of active elements such as gates (redirection and/or retention), storing tanks, and pumping stations, when needed. Therefore, modeling and control of UDS basically consists in knowing and representing the (dynamical) behavior of these elements and managing them properly in order to achieve a given set of control objectives, such as minimization of flooding in streets or maximization of treated wastewater in the system. Given the large number of elements composing an UDS and the interaction between them, management and control strategies may depend on highly complex system models, which implies the explicit difficulty for designing real-time control (RTC) strategies. This paper makes a review of the models used to describe, simulate, and control UDS, proposes a revision of the techniques and strategies commonly used for the control UDS, and finally compares several control strategies based on a case study., Peer Reviewed, Postprint (author’s final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Decentralized control for urban drainage systems via population dynamics : Bogota case study

  • Barreiro Gómez, Julián
  • Obando, Germán
  • Riaño Briceño, Gerardo
  • Quijano Silva, Nicanor
  • Ocampo-Martínez, Carlos
Control of Urban Drainage Systems (UDS) is studied for cases in which the distribution of run–off through the channels of a system is inefficient, i.e. when the capacity of some structures is not used optimally. In this paper, a decentralized population-dynamics-based control for UDS is presented, particularly using the replicator and projection dynamics. For the design, a methodology to make a partitioning of the system is introduced, and the design of a population–dynamics–based control per each partition is proposed. Moreover, a stability analysis of the closed–loop system is made by using passivity theory. Finally, simulation results show the proposed approach performance in a segment of the Bogota stormwater UDS case study., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Optimal sensor placement for leak location in water distribution networks using genetic algorithms

  • Casillas, Myrna V.
  • Puig Cayuela, Vicenç
  • Garza Castañón, Luís Eduardo
  • Rosich, Albert
In this paper, a new approach for sensor placement in water distribution networks (WDN) is proposed. The sensor placement problem is formulated as an integer optimization problem. The optimization criterion consists in minimizing the number of non-isolable leaks according to the isolability criteria introduced. Because of the non-linear integer and largescale nature of the resulting optimization problem, genetic algorithms (GA) are used as solution approach. To validate the results obtained, they are compared with exhaustive search methods with higher computational cost proving that GA allow to find near-optimal solutions with less computational load. The proposed sensor placement algorithm is combined with a projection-based isolation scheme. However, the proposed methodology does not depend on the isolation method chosen by the user and it could be easily adapted to any other isolation scheme. Experiments on a real network allow to evaluate the performance of such approach., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Accuracy assessment of leak localisation method depending on available measurements

  • Pérez Magrané, Ramon
  • Cugueró Escofet, Miquel Àngel
  • Cugueró Escofet, Josep
  • Sanz Estapé, Gerard
Model-based leak localization methods are currently developed and applied to real cases. The performance and success of such methods depend highly both on models [Pérez et al. (2011a)] and the measurements available. The optimal distribution of sensors is a good approach [Pérez et al. (2009)]. Nevertheless, in a huge network with hundreds of District Metered Area (DMA) the question of how the methodology can help with the sensors already installed in the network arises. This paper presents a sequence of steps to assess the performance of a given leakage localization methodology [Quevedo et al. (2011)]. Initially, flow sensors at the control points are used, and inner pressure sensors are added sequentially, since flows are often measured in the network control points and pressure sensors are a common choice for new installed sensors. Using the available sensors information, an investment-precision relationship indicator is proposed. The assessment is applied to a real network situated in Barcelona., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

MPC design based on a DBN reliability model: Application to drinking water networks

  • Salazar Cortés, Jean Carlo
  • Weber, Philipe
  • Sarrate Estruch, Ramon
  • Theilliol, Didier
  • Nejjari Akhi-Elarab, Fatiha
This paper presents a Model Predictive Control (MPC) strategy taking into account system and component reliability for drinking water networks. The objective is to deal from an availability point of view with a closed-loop system combining a deterministic part related to the system dynamics and a stochastic part related to the actuators and system reliability. The main contribution of this work consists in integrating the reliability assessment computed on-line using a Dynamic Bayesian Network (DBN) into the MPC algorithm., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Making non-centralized a model predictive control scheme by using distributed Smith dynamics

  • Barreiro Gómez, Julián
  • Obando, Germán
  • Ocampo-Martínez, Carlos
  • Quijano Silva, Nicanor
This paper proposes a non--centralized Model Predictive Control (MPC) scheme for a system comprised by several sub-systems. Operational constraints for each subsystem are considered as well as a single coupled constraint on the control inputs that models a limitation of the emph{resource} supplied by the controller. If the underlying optimization problem is of large-scale nature, traditional MPC suffers from computational burden issues. A cause of this problem is the requirement of having centralized information to guarantee that the computed control actions satisfy the coupled constraint. In this work, a traditional MPC is made non--centralized by means of a strategy based on distributed population dynamics. The proposed methodology divides the problem into several local MPC controllers that coordinate their decisions by using a communication network without the need of a centralized scheme. It is proved that this methodology provides an optimal solution that satisfies both the operational constraints of each sub--system, and the coupled constraint of the control signals. Finally, the proposed method is compared with a traditional centralized MPC in an industrial problem that involves several continuously stirred tank reactors., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Two-layer scheduling scheme for pump stations

  • Sun, Congcong
  • Puig Cayuela, Vicenç
  • Cembrano Gennari, Gabriela
In this paper, a two-layer scheduling scheme for pump stations in a water distribution network has been proposed. The upper layer, which works in one-hour sampling time, uses Model Predictive Control (MPC) to produce continuous flow set-points for the lower layer. While in the lower layer, a scheduling algorithm has been used to translate the continuous flow set-points to a discrete (ON-OFF) control operation sequence of the pump stations with the constraints that pump stations should draw the same amount of water as the continuous flow set-points provided by the upper layer. The tuning parameters of such algorithm are the lower layer control sampling period and the number of parallel pumps in the pump station. The proposed method has been tested in the Richmond case study., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Gaussian-process-based demand forecasting for predictive control of drinking water networks

  • Wang, Ye
  • Ocampo-Martínez, Carlos
  • Puig Cayuela, Vicenç
  • Quevedo Casín, Joseba Jokin
This paper focuses on water demand forecasting for predictive control of Drinking Water Networks (DWN) in the short term by using Gaussian Process (GP). For the predictive control strategy, system states in a finite horizon are generated by a DWN model and demands are regarded as system disturbances. The goal is to provide a demand estimation within a given confidence interval. For the sake of obtaining a desired forecasting performance, the forecasting process is carried out in two parts: the expected part is forecasted by Double-Seasonal Holt-Winters (DSHW) method and the stochastic part is forecasted by GP method. The mean value of water demand is firstly estimated by DSHW while GP provides estimations within a confidence interval. GP is applied with random inputs to propagate uncertainty at each step. Results of the application of the proposed approach to a real case study based on the Barcelona DWN have shown that the general goal has been successfully reached., Peer Reviewed, Postprint (author’s final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Receding horizon control of hybrid linear delayed systems: application to sewer networks

  • Joseph Duran, Bernat
  • Ocampo-Martínez, Carlos
  • Cembrano Gennari, Gabriela
A control-oriented hybrid linear model for water transport in sewer networks is proposed as a suitable framework for the computation of real-time controllers for the minimization of flooding in presence of heavy-rain events. The model is based on individual network elements (sewers, gates, weirs and tanks) and does not rely on topological simplifications, thus providing a better description of the hydrological and hydraulic phenomena than in similar works. Using a generic form of a hybrid linear model, a simple matrix-based procedure for the formulation and solution of an optimal control problem is also presented. This procedure is applied to the sewer network model for the case study of a part of the Barcelona sewer network in a receding horizon control strategy, showing the effectiveness of the proposed control approach., Peer Reviewed, Postprint (author’s final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Assessment of a leak localization algorithm in water networks under demand uncertainty

  • Cugueró Escofet, Josep
  • Blesa Izquierdo, Joaquim
  • Pérez Magrané, Ramon
  • Cugueró Escofet, Miquel Àngel
  • Sanz Estapé, Gerard
The performance and success of model-based leak localization methods applied to water networks highly depends on the uncertainty of the system considered. One of the main sources of uncertainty in these networks are the demands in the network nodes. This work developes a methodology to evaluate the ability of an existing algorithm to locate leaks in the presence of bounded uncertainty in the node demands. Zonotopic sets are found to be specially suited to bound nodal demand uncertainty. Two consistent approaches to evaluate the effect of demand uncertainty on the decision result are shown: a Montecarlo approach and a Montecarlo combined with zonotope analysis approach. The methodology is presented using a simplified version of an existing leak location algorithm applied to an illustrative network to stress comprehension., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Sensor placement for leak monitoring in drinking water networks combining clustering techniques and a semi-exhaustive search

  • Sarrate Estruch, Ramon
  • Blesa Izquierdo, Joaquim
  • Nejjari Akhi-Elarab, Fatiha
This paper presents an optimal sensor placement strategy based on pressure sensitivity matrix analysis and a semi-exhaustive search strategy that maximizes some diagnosis specifications for water distribution networks. A mean average worst leak expansion distance has been proposed as a new leak location performance measure. The approach is combined with a clustering technique in order to reduce the size and the complexity of the sensor placement problem. The strategy is successfully applied to determine the location of a set of pressure sensors in a district metered area (DMA) in the Barcelona water distribution network (WDN)., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Coordinating multi-layer MPC for complex water systems

  • Sun, Congcong
  • Puig Cayuela, Vicenç
  • Cembrano Gennari, Gabriela
In this paper, coordinating technique for the multi-layer model predictive control (MPC) of complex water network is proposed. A multi-layer topology structure resulting from a functional decomposition of water network is briefly presented. Inside each layer, a MPC based controller is used. Between the related two layers, a multi-layer coordinating mechanism is provided to generate control strategies which consider objectives and time scales of both layers. Optimal Path Method (OPM) is used to estimate aggregated water price for the whole layer. The case study is the Catalunya Regional Water Network. Simulation results based on an aggregate model of this network are provided., Peer Reviewed, Postprint (author’s final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Economic MPC for the management of drinking water networks

  • Grosso Pérez, Juan Manuel
  • Ocampo-Martínez, Carlos
  • Puig Cayuela, Vicenç
  • Limón Marruedo, Daniel
  • Pereira, Mario
This paper addresses the management of drinking water networks (DWNs) regarding a multi-objective cost function by means of economically-oriented model predictive control (EMPC) strategies. Specifically, assuming the water demand and the energy price as periodically time-varying signals, this paper shows that the EMPC framework is flexible to enhance the control of DWNs without relying on hierarchical control schemes that require the use of real-time optimisers (RTO) or steady-state target optimisers (SSTO) in an upper layer. Four different MPC strategies are discussed in this paper: a hierarchical two-layer approach, a standard EMPC where the multi-objective cost function is optimised directly, and two different modifications of the latter, which are meant to overcome possible feasibility losses in the presence of changing operating patterns. The discussed schemes are tested andcompared by means of a case study taken from a part of the Barcelona DWN., Peer Reviewed, Postprint (author’s final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Real-time monitoring and control for efficient management of drinking water networks: Barcelona case study

  • Cembrano Gennari, Gabriela
  • Puig Cayuela, Vicenç
  • Ocampo-Martínez, Carlos
  • Quevedo Casín, Joseba Jokin
  • Mirats Tur, Josep Maria
  • Meseguer Amela, Jordi
  • Ariño Tarrago, Ramon
  • López Martínez, Silvia
Drinking water utilities in urban areas are facing new challenges in their real-time operation: limited water resources, intensive energy requirements, a growing population, a costly and ageing infrastructure, increasingly stringent regulations, and increased attention towards the environmental impact of water use. The efficient use of resources is becoming a priority for water managers and the recent advances in ICT technologies can provide solutions to this end. Real-time management in water networks may be considered as a process comprising two different levels: (i) Monitoring, which is concerned with the observation and estimation of the current state of a system and the detection/diagnosis of abnormal situations. It is achieved through sensors and communications technology, together with mathematical models; and (ii) Control, related to computing and applying the best admissible control strategies for network actuators. Optimal control seeks to optimize a given set of operational goals related to the network performance, such as efficiency in resource use, environmental impact, etc. Real-time monitoring and control techniques can significantly improve the use of water and energy resources in water networks. This paper addresses the developments of the European project EFFINET, which proposes a novel integrated water resource management system based on advanced ICT technologies of automation and telecommunications for improving the efficiency of drinking water networks in terms of water use, energy consumption, water loss minimization, and water quality guarantees by addressing the real-time monitoring and control levels., Peer Reviewed, Postprint (author’s final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

On the assessment of tree-based and chance-constrained predictive control approaches applied to drinking water networks

  • Grosso Pérez, Juan Manuel
  • Maestre Torreblanca, José María
  • Ocampo-Martínez, Carlos
  • Puig Cayuela, Vicenç
Water systems are a challenging problem because of their size and exposure to uncertain influences such as the unknown demands or the meteorological phenomena. In this paper, two different stochastic programming approaches are assessed when controlling a drinking water network: chance-constrained model predictive control (CC-MPC) and tree-based model predictive control (TB-MPC). Under the former approach, the disturbances are modeled as stochastic variables with non-stationary uncertainty description, unbounded support and quasi concave probabilistic distribution. A deterministic equivalent of the related stochastic problem is formulated using Boole’s inequality and a uniform allocation of risk. In the later approach, water demand is modelled as a disturbance rooted tree where branches are formed by the most probable evolutions of the demand. In both approaches, a model predictive controller is used to optimise the expectation of the operational cost of the disturbed system., Postprint (author’s final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Robustness analysis of sensor placement for leak detection and location under uncertain operating conditions

  • Blesa Izquierdo, Joaquim
  • Nejjari Akhi-Elarab, Fatiha
  • Sarrate Estruch, Ramon
Some pressure sensor placement methods for leak detection and location in water distribution networks are based on the pressure sensitivity matrix analysis. This matrix depends on the network demands, which are nondeterministic, and the leak magnitudes, which are unknown. In this paper, the robustness of a sensor placement methodology against the fault sensitivity matrix uncertainty is studied. The robustness study is illustrated by means of a small academic network as well as a district metered area in the Barcelona water distribution network. Results reveal that this uncertainty should be taken into account in the sensor placement methodology., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Leak localization in water distribution networks using pressure residuals and classifiers

  • Ferrandez-Gamot, Lise
  • Bousson, Pierre
  • Blesa Izquierdo, Joaquim
  • Tornil Sin, Sebastián
  • Puig Cayuela, Vicenç
  • Douviella, Eric
  • Soldevila Coma, Adrià
In order to take into account the scarcity of the water resource and the increasing of the population, the management of drinking water networks has to be improved with the use of new tools and actions that allows fighting against wasting water. The monitoring of drinking water networks is based on the use of sensors to locate malfunctions (leaks, quality/contamination events, etc.). Practical implementation has to be carried out by optimizing the placement of the number of sensors and improving the detection and localization of malfunctions. Techniques for the detection and localization of leaks have been proposed in the last years based on the evaluation of residuals obtained by means of the comparison between the measurements obtained by the sensors and the values obtained by simulating the water network in a leak free scenario. In this paper, a data-driven approach based on the use of statistical classifiers working in the residual space is proposed for leak localization. The classifiers are trained using leak data scenarios in all the nodes of the network considering uncertainty in demand distribution, additive noise in sensors and leak magnitude. Finally, the proposed approach is tested using the well-known Hanoi network benchmark., In order to take into account the scarcity of the water resource and the increasing of the population, the management of drinking water networks has to be improved with the use of new tools and actions that allows fighting against wasting water. The monitoring of drinking water networks is based on the use of sensors to locate malfunctions (leaks, quality/contamination events, etc.). Practical implementation has to be carried out by optimizing the placement of the number of sensors and improving the detection and localization of malfunctions. Techniques for the detection and localization of leaks have been proposed in the last years based on the evaluation of residuals obtained by means of the comparison between the measurements obtained by the sensors and the values obtained by simulating the water network in a leak free scenario. In this paper, a data-driven approach based on the use of statistical classifiers working in the residual space is proposed for leak localization. The classifiers are trained using leak data scenarios in all the nodes of the network considering uncertainty in demand distribution, additive noise in sensors and leak magnitude. Finally, the proposed approach is tested using the well-known Hanoi network benchmark., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Multi-layer model predictive control of regional water networks: application to the Catalunya case study

  • Sun, Congcong
  • Puig Cayuela, Vicenç
  • Cembrano Gennari, Gabriela
A multi-layer model predictive control (MPC) scheme with temporal multi-level coordination for regional water networks is proposed. First, a multi-layer control structure resulting from a functional decomposition of water network is briefly presented. Inside each layer, a MPC based controller is used. Between related layers, a temporal multi-level coordination mechanism is used to generate control strategies which consider objectives and time scales of both layers. The proposed approach will be applied to the Catalunya Regional Water Network. The paper presents the results based on an aggregate model of this network., Peer Reviewed, Postprint (author’s final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Model-free control for wind farms using a gradient estimation-based algorithm

  • Barreiro Gómez, Julián
  • Ocampo-Martínez, Carlos
  • Bianchi, Fernando Daniel
  • Quijano Silva, Nicanor
Wind turbines working close to other turbines experience interactions that affect the power production. These interactions arise as a consequence of wakes caused by upstream wind turbines. In order to achieve a more effective and precise control of the power generated by wind farms, the control strategy must consider these interactions. However, the phenomena involved in wake effects are complex especially in cases of large number of turbines. This paper presents the implementation of a gradient estimation-based algorithm as a model-free control for two different control schemes aimed to maximize the energy capture of a wind farm. One control is centralized, leaving to a supervisor the task of command computation and the other topology is decentralized, distributing the performing generation among wind turbines. This latter scheme aims to increase the reliability of the wind farm operation by reducing the communications needed to fulfill the objective of maximizing energy capture. Both control schemes are evaluated by simulation in the case of three-turbine wind farm., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Decentralised fault diagnosis of large-scale systems: application to water transport networks

  • Puig Cayuela, Vicenç
  • Ocampo-Martínez, Carlos
In this paper, a decentralised fault diagnosis approach for large-scale systems is proposed. This approach is based on obtaining a set of local diagnosers using the analytical redundancy relation (ARRs) approach. The proposed approach starts with obtaining the set of ARRs of the system yielding into an equivalent graph. From that graph, the graph partitioning problem is solved obtaining a set of ARRs for each local diagnoser. Finally, a decentralised fault diagnosis strategy is proposed and applied over the resultant set of partitions and ARRs. In order to illustrate the application of the proposed approach, a case study based on the Barcelona drinking water network (DWN) is used., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Actuator-fault detection and isolation based on interval observers and invariant sets

  • Xu, Feng
  • Puig Cayuela, Vicenç
  • Ocampo-Martínez, Carlos
  • Stoican, Florin
  • Olaru, Sorin
This paper proposes an interval observer-based actuator fault detection and isolation (FDI) approach. An interval observer matching the healthy system mode is designed to monitor the system. When the system is in different modes, state or output interval vectors predicted by the interval observer manifest different dynamical behaviors. To guarantee reliable FDI, a collection of invariant set-based FDI conditions are established. Under these conditions, actuator faults can be accurately detected and isolated during the transition between different modes. At the end, the effectiveness of this proposed approach is presented by using a numerical example., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Uncertainty effect on leak localisation in a DMA

  • Pérez Magrané, Ramon
  • Cugueró Escofet, Josep
  • Blesa Izquierdo, Joaquim
  • Cugueró Escofet, Miquel Àngel
  • Sanz, Gerard
The leak localisation methodologies based on data and models are affected by both uncertainties in the model and in the measurements. This uncertainty should be quantified so that its effect on the localisation methods performance can be estimated. In this paper, a model-based leak localisation methodology is applied to a real District Metered Area using synthetic data. In the generation process of the data, uncertainty in demands is taken into account. This uncertainty was estimated so that it can justify the uncertainty observed in the real measurements. The leak localisation methodology consists, first, in generating the set of possible measurements, obtained by Monte Carlo Simulation under a certain leak assumption and considering uncertainty, and second, in falsifying sets of nodes using the correlation with a leak residual model in order to signal a set of possible leaky nodes. The assessment is done by means of generating the confusion matrix with a Monte Carlo approach., Peer Reviewed, Postprint (author's final draft)