Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Behaviour of retrofited precast UHPC and Ni-Ti SMA column-to-foundation connection with CFRP wrapping layers

  • Pereiro-Barceló, Javier
  • Bonet, José L.
  • Rueda-García, Lisbel
  • Ciurana-Tatay, Álvaro
  • Pereiro-Barceló, Javier|||/items/6dce1875-46f5-4715-9229-958f7be7228d
Four precast column-to-foundation connection specimens, previously tested under lateral reversed cyclic loading and constant axial load (first-stage tests), were repaired with Carbon Fibre Reinforced Polymer (CFRP) layers in the areas where plastic hinges had formed and were retested under the same loads (second-stage tests). The columns were originally manufactured with ultrahigh-performance concrete (UHPC) with high stee-fibre content (volumetric steel/fibre ratio 1.9%). The steel bars in the connection were replaced with superelastic Ni-Ti SMA bars that crossed the column/foundation interface. Two types of connection between the precast column and the foundation were analysed: protruding bars and smooth pocket bars (SP). The specimens were subjected to the same constant level of relative axial load in both the first and second-stage tests. The objective was to determine whether the initial performance of precast UHPC and SMA reinforced column-to-foundation connections against lateral cyclic loads can be restored after a seismic event by means of simple and economic retrofitting. The effectiveness of the number of strengthening CFRP layers was also studied (two or three CFRP wrapping layers) for each column-to-foundation connection type. The main results for PB and SP connection specimens with respect to the original specimens were respectively: an average strength capacity loss of 8% and 19%, displacement ductility increase of 8% and 42%, dissipated energy 48% and 53% higher and initial stiffness 9.5% and 21% lower. No significant differences were observed in the repairs done with two or three CFRP wrapping layers.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Design Recommendations for Columns Made of Ultra-High-Performance Concrete and NiTi SMA Bars

  • Pereiro-Barceló, Javier
  • Bonet, José L.
  • Martínez-Jaén, Begoña
  • Cabañero-Escudero, Beatriz
  • Pereiro-Barceló, Javier|||/items/6dce1875-46f5-4715-9229-958f7be7228d
The use of new materials in construction endows structures with better mechanical characteristics. The combination of ultra-high-performance concrete (UHPC) and nickel and titanium (NiTi) shape memory alloy (SMA) improves the behavior of building structures by increasing both their ductility and dissipation energy due to the low-damage and self-centering properties of NiTi SMA. Since UHPC and NiTi SMA are expensive materials and still scarce in distribution channels, this article tries to offer design recommendations to reduce the length of the column-beam connection in which these new materials should be introduced, leaving the rest of the column with conventional materials. To achieve this, a nonlinear static pushover analysis of columns using finite element software, SeismoStruct, was performed. This model was calibrated using experimental results. Next, a parametric analysis was carried out to propose the design recommendations. Results indicated that an adequate design for the column–beam connection, considering both economy and performance, should include a main zone with UHPC and SMA reinforcements, a transition zone with UHPC and steel reinforcements, and another zone with conventional reinforced concrete. The transition zone improved the hybrid column’s performance without excessively raising the cost. The main zone length, the transition zone length, and the strength of the concrete in the rest of the column must be determined to ensure that the critical section of the column was in the main zone to develop the maximum strength and ductility. The length of the main zone depended on the compressive strength of the conventional concrete, the relative axial load of the column, and the required ductility.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Cyclic response of precast column-to-foundation connection using uhpc and Ni–Ti SMA reinforcements in columns

  • Pereiro-Barceló, Javier
  • Bonet, José L.
  • Rueda-García, Lisbel
  • Albiol-Ibáñez, José Ramón
  • Pereiro-Barceló, Javier|||/items/6dce1875-46f5-4715-9229-958f7be7228d
Earthquakes are catastrophic natural events with a special impact on reinforced concrete structures due to the horizontal loads that they introduce into structures. To adequately resist an earthquake, a precast structure must have a high deformation capacity, dissipate energy in each earthquake cycle, undergo less damage and fewer residual deformations. To achieve all this, the behaviour of precast columns made with UPHC was herein experimentally analysed. Steel rebars were replaced with Nisingle bondTi shape memory alloy (SMA) bars with superelasticity (SE) in the critical zone of the column-to-foundation connection. The Nisingle bondTi SMA bars crossed the interface between the column and foundation. Two types of connection with the foundation were studied: smooth pocket type and protruding bar type. Columns were subjected to constant compression and a cyclic lateral load. Rocking behaviour was observed at the connection critical section. The use of advanced materials allowed a moment-rotation behaviour of the connection to be developed without any significant damage. Low residual deformations were observed while testing because of both the damage in UHPC was low and the superelasticity of the Nisingle bondTi SMA bars.