Pasar al contenido principal

ESTRATEGIAS DE MEJORA DE LA DUCTILIDAD FRENTE A ACCIONES SISMICAS DE UNIONES DE ELEMENTOS PREFABRICADOS MEDIANTE EL EMPLEO DE NUEVOS MATERIALES

BIA2012-32645

•
Nombre agencia financiadora Ministerio de Economía y Competitividad
Acrónimo agencia financiadora MINECO
Programa Programa Nacional de Proyectos de Investigación Fundamental
Subprograma Subprograma de Proyectos de Investigación Fundamental no Orientada
Convocatoria Proyectos I+D
Año convocatoria 2012
Plan Estatal 2008-2011 Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica
Unidad de gestión Secretaría de Estado de Investigación, Desarrollo e Innovación
Centro beneficiario UNIVERSITAT POLITÈCNICA DE VALÈNCIA
Identificador persistente http://dx.doi.org/10.13039/501100003329

Resultados relacionados

Resultados totales (Incluyendo duplicados): 14
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Ni-Ti SMA bars behaviour under compression

  • Pereiro Barceló, Javier
  • Bonet Senach, José Luís|||0000-0002-6687-5307
[EN] SMA (Shape Memory Alloys) is a type of material suitable for using in civil engineering as concrete reinforcement because of their shape memory effect or superelasticity and their high ductility and damping capacity. However, Ni-Ti alloys Young modulus could be 3 or 4 times lower than steel (200 GPa) depending on the composition and thermal treatment, which can cause the instability of compressed bars. The main objective of this work is to provide a modified constitutive model of SMA bars, particularized for Ni-Ti bars, that considers instability in compression. The inclusion of this effect in the constitutive equation allows for simulating Ni-Ti bars under compression in a simple way as if they were perfectly straight bars. To achieve this, six 12-mm diameter SMA bars made of Ni-Ti were tested under compression. The mechanical slendernesses of the six Ni-Ti samples were: 28.33, 38, 48, 66, 82 and 108.33. Thirty steel specimens were tested beforehand to validate the experimental setup and to calibrate the subsequent Abaqus finite element model. This model aims to conduct a parametric study to validate the proposed constitutive model of Ni-Ti bars, including instability in compression., The model presented here is part of a research strand that is being undertaken within the Concrete Science and Technology Institute (ICITECH) at the Universitat Politècnica de València (UPV). The authors are sincerely grateful to the Spanish Ministry of Economy and Competitiveness for the help it has provided through Project BIA2012-32645 and to the European Union for financial support obtained from FEDER funds. Besides, authors wish to thank Alberto Navarro Gómez and Oscar Sahuquillo Navarro for helping with material characterization.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Cyclic behavior of hybrid RC columns using High-Performance Fiber-Reinforced Concrete and Ni-Ti SMA bars in critical regions

  • Pereiro-Barceló, Javier
  • Cabañero-Escudero, Beatriz
  • Martínez-Jaén, Begoña
  • Bonet Senach, José Luís|||0000-0002-6687-5307
[EN] Thanks to their excellent deformation capacity and ductility, smart materials are now being increasingly used in the construction industry, one example being superelastic Shape Memory Alloys (SMA)such as Ni-Ti, which can recover from large strains without generating significant residual strains. The purpose of this work was to study the behavior under cyclic loading of hybrid-reinforced concrete columns containing super-elastic Ni-Ti bars and High-Performance Fiber-Reinforced Concrete (HPFRC) in their critical end regions, where plastic hinges may form (column ends). This critical region is a dissipative zone of the column where the most adverse combination of actions occurs. An experimental study was carried out to simulate inter-story columns in which the effects of the axial level and continuous or discontinuous beam-column joints were analyzed. The specimens with continuous joints were found to display greater lateral strength, ductility and energy dissipation, while those with discontinuous joints underwent smaller residual displacements and less damage in the critical regions of the columns., The study described here forms part of the research undertaken at the Concrete Science and Technology Institute (ICITECH) of the Universitat Politecnica de Valencia (UPV). This work was supported by the Spanish Ministry of Economy and Competitiveness through Project BIA2012-32645, and by the European Union through European Regional Development Funds (ERDF). The authors wish to thank the Spanish Ministry of Education, Culture and Sport for Grant FPU12/01451.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Improving the seismic behaviour of Reinforced Concrete Moment Resisting Frames by means of SMA bars and Ultra-High Performance Concrete

  • Navarro-Gómez, Alberto
  • Bonet Senach, José Luís|||0000-0002-6687-5307
[EN] In the design of concrete buildings in seismic zones, ductility is normally used to reduce design efforts and as a form of energy dissipation. This implies structural damage to buildings in the form of interstorey drifts that need to be subsequently repaired or demolished. Twelve moment resisting frames (MRF) were designed with different geometrical configurations and new materials, and shape memory alloy bars and ultra-high performance concrete were used in the critical zones of the structure to improve their seismic behaviour. MRFs were subjected to a non-linear static pushover analysis and an incremental dynamic analysis to assess their behaviour. To do so, six real accelerograms were selected to study the response of the 12 MRFs, scaled at increasing peak ground acceletation (PGA). The base shear, the building¿s overall plastic mechanism and the seismic response factors for the different geometrical and material combinations were analysed. The obtained values were compared with ASCE 7-05 and EC-8 proposals. It was concluded that the combination of shape memory alloys and ultra-high performance concrete allowed the behaviour factor to increase and residual drifts to decrease, which are advantages for both design and seismic behaviour., This article forms part of the research conducted at the Concrete Science and Technology Institute (ICITECH) of the Universitat Politecnica de Valencia (UPV). This work has been supported by the Spanish Ministry of Economy and Competitiveness through Project BIA2012-32645, and by the European Union through FEDER funds. The authors thank the Spanish Ministry of Education, Culture and Sport for Grant FPU13/06337.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Cm-factor for RC slender columns under unequal eccentricities and skew angle loads at the ends

  • Da Costa Lino Leite, Luiz Carlos
  • Bonet Senach, José Luís|||0000-0002-6687-5307
  • Pallarés Rubio, Luis|||0000-0003-2126-2387
  • Miguel Sosa, Pedro|||0000-0001-5395-8149
Reinforced concrete slender columns, in general, are subjected to a non-uniform bending moment law, due to the occurrence of unequal eccentricities and skew angles at the ends. Design codes suggest calculating an equivalent moment factor Cm in each bending direction with the aim of reducing the analysis of the column to another equivalent one with equal eccentricities and angles at the ends. This paper presents a new equation to compute the equivalent moment factor Cm derived from the numerical model. This model has been calibrated and checked with 255 experimental tests from the literature. The experiments correspond to RC slender columns, pinned pinned and subjected to short-term ultimate loads and unequal eccentricities at the ends, for both uniaxial bending and biaxial bending. In HSC slender columns, a factor k3 is proposed to be applied along the concrete cover region in order to take into account the concrete cover spalling off. From the comparison with the current formula of the design codes (ACI-318 and Eurocode 2), the proposed Cm increases the safety factor for low and medium slenderness of the column (&#955;g < 20), low levels of axial load (N/Ncr < 0.50), high-strength concrete (50 < fc < 100 MPa) and double curvature bending (&#946; < 0). The proposed formula allows reinforced concrete slender columns to be both checked and designed with enough accuracy for practice engineering, and is simple to apply., The content of this article is part of a research work carried out by the Universitat Politecnica de Valencia and the Institute of Concrete Science and Technology (ICITECH). The authors of this work wish to thank the Research Bureau of the Spanish Ministry of Economy and Competitivenes, the Plan E and the European Regional Development Fund for the co-funding of the research projects BIA2006-06429 and BIA BIA-2012-32645.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Design Recommendations for Columns Made of Ultra-High-Performance Concrete and NiTi SMA Bars

  • Pereiro-Barceló, Javier
  • Martínez-Jaén, Begoña
  • Cabañero-Escudero, Beatriz
  • Bonet Senach, José Luís|||0000-0002-6687-5307
[EN] The use of new materials in construction endows structures with better mechanical characteristics. The combination of ultra-high-performance concrete (UHPC) and nickel and titanium (NiTi) shape memory alloy (SMA) improves the behavior of building structures by increasing both their ductility and dissipation energy due to the low-damage and self-centering properties of NiTi SMA. Since UHPC and NiTi SMA are expensive materials and still scarce in distribution channels, this article tries to offer design recommendations to reduce the length of the column-beam connection in which these new materials should be introduced, leaving the rest of the column with conventional materials. To achieve this, a nonlinear static pushover analysis of columns using finite element software, SeismoStruct, was performed. This model was calibrated using experimental results. Next, a parametric analysis was carried out to propose the design recommendations. Results indicated that an adequate design for the column-beam connection, considering both economy and performance, should include a main zone with UHPC and SMA reinforcements, a transition zone with UHPC and steel reinforcements, and another zone with conventional reinforced concrete. The transition zone improved the hybrid column's performance without excessively raising the cost. The main zone length, the transition zone length, and the strength of the concrete in the rest of the column must be determined to ensure that the critical section of the column was in the main zone to develop the maximum strength and ductility. The length of the main zone depended on the compressive strength of the conventional concrete, the relative axial load of the column, and the required ductility., This work was supported by the Spanish Ministry of Economy and Competitiveness through Project BIA2012-32645 and by the European Union through European Regional Development Funds (ERDF). The project was executed at the Concrete Science and Technology Institute (ICITECH) of the Universitat Politècnica de València (UPV). The article processing charge was paid by the University of Alicante (UA). The authors wish to thank the Spanish Ministry of Education, Culture and Sport for Grant FPU12/01451.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Mixed model for the analytical determination of critical buckling load of passive reinforcement in compressed RC and FRC elements under monotonic loading

  • Pereiro Barceló, Javier
  • Bonet Senach, José Luís|||0000-0002-6687-5307
[EN] Compressed reinforcements on reinforced concrete (RC) and steel fibre reinforced concrete (SFRC) columns are generally submitted to cyclic and monotonic loading, which can buckle. This phenomenon can cause the reduction of both ductility and peak loads, which is why design standards propose constructive details to avoid this. Although the bibliography mentions that steel fibres in concrete can delay buckling of reinforcements, design codes do not distinguish between concrete types (with and without fibres) in these constructive details. Analytical models that determine the length and critical buckling stress of reinforcements may consider this effect. Nowadays, analytical models can be classified as discrete and distributed depending on whether they consider transverse reinforcement stiffness and the stiffness of the concrete cover that concentrates on transverse reinforcements, or if they are distributed along the element, respectively. Both discrete and distributed models are valid for small transverse reinforcement separations, while distributed models that only consider the concrete cover effect are valid for large transverse reinforcement separations. This paper proposes a mixed model to determine critical buckling loads of compressed reinforcements subjected to monotonic loading to use the stress-strain relationships of reinforcing bars, including buckling, that are found in the scientific-technical literature. This model considers transverse reinforcements discretely and concrete cover distributedly. The model can be applied to any transverse reinforcement configuration, and to any concrete type (with or without fibres). An analytical equation is also proposed to determine critical compressed reinforcement loads, whose result is presented as abaci. Finally, to calibrate the model in normal-strength concrete columns under eccentric loading, with or without fibres, a programme is presented in which the critical load of longitudinal reinforcements is experimentally determined. The proposed analytical model is calibrated and a procedure to determine critical buckling loads of compressed reinforcements under monotonic loading is proposed., The model presented herein forms part of a research line that is being undertaken at the Concrete Science and Technology Institute (ICITECH) of the Universitat Politècnica de València (UPV). The authors are sincerely grateful to the Spanish Ministry of Economy and Competitiveness for the help it has provided through Project BIA2012-32645 and to the European Union for financial support obtained from FEDER funds
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Behaviour of retrofited precast UHPC and Ni-Ti SMA column-to-foundation connection with CFRP wrapping layers

  • Pereiro-Barceló, Javier
  • Ciurana-Tatay, Álvaro
  • Bonet Senach, José Luís|||0000-0002-6687-5307
  • Rueda-García, Lisbel|||0000-0002-2061-1656
[EN] Four precast column-to-foundation connection specimens, previously tested under lateral reversed cyclic loading and constant axial load (first-stage tests), were repaired with Carbon Fibre Reinforced Polymer (CFRP) layers in the areas where plastic hinges had formed and were retested under the same loads (second-stage tests). The columns were originally manufactured with ultrahigh-performance concrete (UHPC) with high stee-fibre content (volumetric steel/fibre ratio 1.9%). The steel bars in the connection were replaced with superelastic Ni-Ti SMA bars that crossed the column/foundation interface. Two types of connection between the precast column and the foundation were analysed: protruding bars and smooth pocket bars (SP). The specimens were subjected to the same constant level of relative axial load in both the first and second-stage tests. The objective was to determine whether the initial performance of precast UHPC and SMA reinforced column-to-foundation connections against lateral cyclic loads can be restored after a seismic event by means of simple and economic retrofitting. The effectiveness of the number of strengthening CFRP layers was also studied (two or three CFRP wrapping layers) for each column-to-foundation connection type. The main results for PB and SP connection specimens with respect to the original specimens were respectively: an average strength capacity loss of 8% and 19%, displacement ductility increase of 8% and 42%, dissipated energy 48% and 53% higher and initial stiffness 9.5% and 21% lower. No significant differences were observed in the repairs done with two or three CFRP wrapping layers., This paper forms part of a line of research carried out at the University Institute of Concrete Science and Technology (ICITECH) of the Universitat Politecnica de Valencia. The authors wish to thank the Spanish Ministry of Science and Innovation for the support provided through Projects BIA2012-32645 and RTI2018-099091-B-C21-AR, and Grant BES-2016-078010 from the European Union for the financial support with FEDER funds, and the Spanish Ministry of Education, Culture and Sport for Grant FPU12/01451.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Ductility of high-performance concrete and very-high-performance concrete elements with Ni-Ti reinforcements

  • Pereiro-Barceló, Javier
  • Goméz-Portillo, Salvador
  • Bonet Senach, José Luís|||0000-0002-6687-5307
  • Castro-Bugallo, M Carmen|||0000-0001-9201-6162
[EN] This article presents an experimental study on the behavior of high performance concrete (HPC) and very high performance concrete (VHPC) concrete columns with Nickel-Titanium (Ni-Ti) shape memory alloy (SMA) reinforcements in critical regions subjected to constant axial and lateral cyclic load combinations. These materials make the cast-in-place of concrete easier by reducing the amount of transverse reinforcement, improving performance, attenuating damage in critical regions, minimizing residual deformations and reducing repair costs in structures located in seismic areas. Seven experimental tests were carried out to analyze the behavior of this element type. A nonlinear static cyclic pushover analysis was performed with finite element software (OpenSees), whose results were compared with the experimental results. This analysis allowed a parametric analysis to be run to extrapolate the experimental results. Strength capacity was approximately 41.8% greater in absolute terms in the specimens manufactured with VHPC and 6.2% greater in a dimensional terms in those manufactured with HPC. Displacement ductility was 34.0% higher in the HPC specimens, and lowered with relative normal force and with transverse reinforcement separation. A residual drift ratio below 0.70% was generally observed when specimens reached 20% strength capacity loss. The residual drift ratio increased as a result of progressive concrete cover degradation, especially in the specimens manufactured with HPC. (C) 2018 Elsevier Ltd. All rights reserved., This article forms part of the research carried out at the Concrete Science and Technology Institute (ICITECH) of the Universitat Politecnica de Valencia (UPV). This work has been supported by the Spanish Ministry of Economy and Competitiveness through Project BIA2012-32645, and by the European Union through ERDF funds. The authors thank the Spanish Ministry of Education, Culture and Sport for Grant FPU12/01451.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Required tie spacing to prevent inelastic local buckling of longitudinal reinforcements in RC and FRC elements

  • Pereiro-Barceló, Javier
  • Bonet Senach, José Luís|||0000-0002-6687-5307
  • Albiol Ibáñez, José Ramón|||0000-0003-3049-9693
[EN] Compressed reinforcement buckling in concrete columns can reduce ductility in structural elements. In order to avoid this, design codes propose maximum required tie spacing. Nonetheless, they do not incorporate the positive effect of concrete fibers in their formulation, whose capability of delaying buckling has been proved. For this reason, recommendations for maximum required tie spacing for elements made with concrete, with or without steel fibers, and with normal or high strength, are proposed in this article. In order to achieve this, the mixed model proposed by Pereiro-Barceló and Bonet was extended to consider elements made of HSC with and without steel fibers thanks to the results of an experimental campaign of HSC columns with and without fibers, under monotonic loading. In these tests, the buckling critical load in compressed reinforcement was experimentally determined in all the columns. In addition, a comparison of the proposed transverse concrete separation with respect to the recommendations proposed by the main existing codes was made., The research presented herein forms part of a research undertaken at the Concrete Science and Technology Institute (ICITECH) of the Universitat Politecnica de Valencia (UPV). The authors are sincerely grateful to the Spanish Ministry of Economy and Competitiveness for the help provided through Project BIA2012-32645, and to the European Union for the financial support obtained from FEDER funds. The authors wish to thank the Spanish Ministry of Education, Culture and Sport for Grant FPU12/01451.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Buckling of steel and Ni-Ti reinforcements in very high performance concrete (VHPC) elements

  • Pereiro-Barceló, Javier
  • Bonet Senach, José Luís|||0000-0002-6687-5307
  • Albiol Ibáñez, José Ramón|||0000-0003-3049-9693
[EN] Nowadays, the use of new materials is becoming increasingly common in the construction world due to their improved properties. High or Very High Performance Concrete (HPC or VHPC) and Shape Memory Alloys (SMA), specifically those composed of nickel and titanium (Ni-Ti), are some of these new materials. The low austenitic modulus of Ni-Ti as regards the elasticity modulus of steel (40-65 GPa instead of 200 GPa) can cause local buckling. In order to replace steel bars with Ni-Ti bars in reinforced concrete elements, it is convenient to use concrete with a high steel fibre content to delay local bar buckling. Hence employing either High Performance Concrete or VHPC may be appropriate, due to its composition with a high steel fibre content. For all these reasons, VHPC elements with Ni-Ti reinforcements were studied. The results of an experimental campaign of VHPC columns are shown in this article. The VHPC columns were subjected to monotonic loading where the main goal was to study compressed steel reinforcement buckling. The results of these tests were also used to extend the mixed model proposed by Pereiro-Barceló and Bonet (2017), which determines the buckling critical stress for any transverse reinforcement separation and considers the effect of the concrete cover (with and without steel fibres). This model was recalibrated to consider elements made of VHPC. Besides, specimens made of either High Performance Concrete (HPC) or VHPC, and with Ni-Ti reinforcements, were also tested to study the behaviour of compressed Ni-Ti reinforcements in elements made of high strength fibre-reinforced concrete., The research presented herein forms part of a research undertaken at the Concrete Science and Technology Institute (ICITECH) of the Universitat Politecnica de Valencia (UPV). The authors are sincerely grateful to the Spanish Ministry of Economy and Competitiveness for the help provided through Project BIA2012-32645, and to the European Union for the financial support obtained from FEDER funds. The authors wish to thank the Spanish Ministry of Education, Culture and Sport for Grant FPU12/01451.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Cyclic response of precast column-to-foundation connection using UHPC and Ni-Ti SMA reinforcements in columns

  • Pereiro-Barceló, Javier
  • Bonet Senach, José Luís|||0000-0002-6687-5307
  • Rueda-García, Lisbel|||0000-0002-2061-1656
  • Albiol Ibáñez, José Ramón|||0000-0003-3049-9693
[EN] Earthquakes are catastrophic natural events with a special impact on reinforced concrete structures due to the horizontal loads that they introduce into structures. To adequately resist an earthquake, a precast structure must have a high deformation capacity, dissipate energy in each earthquake cycle, undergo less damage and fewer residual deformations. To achieve all this, the behaviour of precast columns made with UPHC was herein experimentally analysed. Steel rebars were replaced with Ni-Ti shape memory alloy (SMA) bars with super elasticity (SE) in the critical zone of the column-to-foundation connection. The Ni-Ti SMA bars crossed the interface between the column and foundation. Two types of connection with the foundation were studied: smooth pocket type and protruding bar type. Columns were subjected to constant compression and a cyclic lateral load. Rocking behaviour was observed at the connection critical section. The use of advanced materials allowed a moment-rotation behaviour of the connection to be developed without any significant damage. Low residual deformations were observed while testing because of both the damage in UHPC was low and the superelasticity of the Ni-Ti SMA bars., This paper forms part of a research line carried out at the Institute of Concrete Science and Technology (ICITECH) of the Universitat Politecnica de Valencia. The authors wish to thank to the Government of Spain Ministry of Economy and Competitiveness for the support it pro-vided through Project BIA2012-32645, to the Government of Spain Ministry of Science and Innovation for the project RTI2018-099091-B-C21-AR, and the grant BES-2016-078010, to the European Union for the financial support with FEDER funds and to the Government of Spain Ministry of Education, Culture and Sports for grant FPU12/01451.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Behaviour of retrofited precast UHPC and Ni-Ti SMA column-to-foundation connection with CFRP wrapping layers

  • Pereiro-Barceló, Javier
  • Bonet, José L.
  • Rueda-García, Lisbel
  • Ciurana-Tatay, Álvaro
  • Pereiro-Barceló, Javier|||/items/6dce1875-46f5-4715-9229-958f7be7228d
Four precast column-to-foundation connection specimens, previously tested under lateral reversed cyclic loading and constant axial load (first-stage tests), were repaired with Carbon Fibre Reinforced Polymer (CFRP) layers in the areas where plastic hinges had formed and were retested under the same loads (second-stage tests). The columns were originally manufactured with ultrahigh-performance concrete (UHPC) with high stee-fibre content (volumetric steel/fibre ratio 1.9%). The steel bars in the connection were replaced with superelastic Ni-Ti SMA bars that crossed the column/foundation interface. Two types of connection between the precast column and the foundation were analysed: protruding bars and smooth pocket bars (SP). The specimens were subjected to the same constant level of relative axial load in both the first and second-stage tests. The objective was to determine whether the initial performance of precast UHPC and SMA reinforced column-to-foundation connections against lateral cyclic loads can be restored after a seismic event by means of simple and economic retrofitting. The effectiveness of the number of strengthening CFRP layers was also studied (two or three CFRP wrapping layers) for each column-to-foundation connection type. The main results for PB and SP connection specimens with respect to the original specimens were respectively: an average strength capacity loss of 8% and 19%, displacement ductility increase of 8% and 42%, dissipated energy 48% and 53% higher and initial stiffness 9.5% and 21% lower. No significant differences were observed in the repairs done with two or three CFRP wrapping layers.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Design Recommendations for Columns Made of Ultra-High-Performance Concrete and NiTi SMA Bars

  • Pereiro-Barceló, Javier
  • Bonet, José L.
  • Martínez-Jaén, Begoña
  • Cabañero-Escudero, Beatriz
  • Pereiro-Barceló, Javier|||/items/6dce1875-46f5-4715-9229-958f7be7228d
The use of new materials in construction endows structures with better mechanical characteristics. The combination of ultra-high-performance concrete (UHPC) and nickel and titanium (NiTi) shape memory alloy (SMA) improves the behavior of building structures by increasing both their ductility and dissipation energy due to the low-damage and self-centering properties of NiTi SMA. Since UHPC and NiTi SMA are expensive materials and still scarce in distribution channels, this article tries to offer design recommendations to reduce the length of the column-beam connection in which these new materials should be introduced, leaving the rest of the column with conventional materials. To achieve this, a nonlinear static pushover analysis of columns using finite element software, SeismoStruct, was performed. This model was calibrated using experimental results. Next, a parametric analysis was carried out to propose the design recommendations. Results indicated that an adequate design for the column–beam connection, considering both economy and performance, should include a main zone with UHPC and SMA reinforcements, a transition zone with UHPC and steel reinforcements, and another zone with conventional reinforced concrete. The transition zone improved the hybrid column’s performance without excessively raising the cost. The main zone length, the transition zone length, and the strength of the concrete in the rest of the column must be determined to ensure that the critical section of the column was in the main zone to develop the maximum strength and ductility. The length of the main zone depended on the compressive strength of the conventional concrete, the relative axial load of the column, and the required ductility.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Cyclic response of precast column-to-foundation connection using uhpc and Ni–Ti SMA reinforcements in columns

  • Pereiro-Barceló, Javier
  • Bonet, José L.
  • Rueda-García, Lisbel
  • Albiol-Ibáñez, José Ramón
  • Pereiro-Barceló, Javier|||/items/6dce1875-46f5-4715-9229-958f7be7228d
Earthquakes are catastrophic natural events with a special impact on reinforced concrete structures due to the horizontal loads that they introduce into structures. To adequately resist an earthquake, a precast structure must have a high deformation capacity, dissipate energy in each earthquake cycle, undergo less damage and fewer residual deformations. To achieve all this, the behaviour of precast columns made with UPHC was herein experimentally analysed. Steel rebars were replaced with Nisingle bondTi shape memory alloy (SMA) bars with superelasticity (SE) in the critical zone of the column-to-foundation connection. The Nisingle bondTi SMA bars crossed the interface between the column and foundation. Two types of connection with the foundation were studied: smooth pocket type and protruding bar type. Columns were subjected to constant compression and a cyclic lateral load. Rocking behaviour was observed at the connection critical section. The use of advanced materials allowed a moment-rotation behaviour of the connection to be developed without any significant damage. Low residual deformations were observed while testing because of both the damage in UHPC was low and the superelasticity of the Nisingle bondTi SMA bars.