Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 6
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Cyclic behavior of hybrid RC columns using High-Performance Fiber-Reinforced Concrete and Ni-Ti SMA bars in critical regions

  • Pereiro-Barceló, Javier
  • Cabañero-Escudero, Beatriz
  • Martínez-Jaén, Begoña
  • Bonet Senach, José Luís|||0000-0002-6687-5307
[EN] Thanks to their excellent deformation capacity and ductility, smart materials are now being increasingly used in the construction industry, one example being superelastic Shape Memory Alloys (SMA)such as Ni-Ti, which can recover from large strains without generating significant residual strains. The purpose of this work was to study the behavior under cyclic loading of hybrid-reinforced concrete columns containing super-elastic Ni-Ti bars and High-Performance Fiber-Reinforced Concrete (HPFRC) in their critical end regions, where plastic hinges may form (column ends). This critical region is a dissipative zone of the column where the most adverse combination of actions occurs. An experimental study was carried out to simulate inter-story columns in which the effects of the axial level and continuous or discontinuous beam-column joints were analyzed. The specimens with continuous joints were found to display greater lateral strength, ductility and energy dissipation, while those with discontinuous joints underwent smaller residual displacements and less damage in the critical regions of the columns., The study described here forms part of the research undertaken at the Concrete Science and Technology Institute (ICITECH) of the Universitat Politecnica de Valencia (UPV). This work was supported by the Spanish Ministry of Economy and Competitiveness through Project BIA2012-32645, and by the European Union through European Regional Development Funds (ERDF). The authors wish to thank the Spanish Ministry of Education, Culture and Sport for Grant FPU12/01451.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Behaviour of retrofited precast UHPC and Ni-Ti SMA column-to-foundation connection with CFRP wrapping layers

  • Pereiro-Barceló, Javier
  • Ciurana-Tatay, Álvaro
  • Bonet Senach, José Luís|||0000-0002-6687-5307
  • Rueda-García, Lisbel|||0000-0002-2061-1656
[EN] Four precast column-to-foundation connection specimens, previously tested under lateral reversed cyclic loading and constant axial load (first-stage tests), were repaired with Carbon Fibre Reinforced Polymer (CFRP) layers in the areas where plastic hinges had formed and were retested under the same loads (second-stage tests). The columns were originally manufactured with ultrahigh-performance concrete (UHPC) with high stee-fibre content (volumetric steel/fibre ratio 1.9%). The steel bars in the connection were replaced with superelastic Ni-Ti SMA bars that crossed the column/foundation interface. Two types of connection between the precast column and the foundation were analysed: protruding bars and smooth pocket bars (SP). The specimens were subjected to the same constant level of relative axial load in both the first and second-stage tests. The objective was to determine whether the initial performance of precast UHPC and SMA reinforced column-to-foundation connections against lateral cyclic loads can be restored after a seismic event by means of simple and economic retrofitting. The effectiveness of the number of strengthening CFRP layers was also studied (two or three CFRP wrapping layers) for each column-to-foundation connection type. The main results for PB and SP connection specimens with respect to the original specimens were respectively: an average strength capacity loss of 8% and 19%, displacement ductility increase of 8% and 42%, dissipated energy 48% and 53% higher and initial stiffness 9.5% and 21% lower. No significant differences were observed in the repairs done with two or three CFRP wrapping layers., This paper forms part of a line of research carried out at the University Institute of Concrete Science and Technology (ICITECH) of the Universitat Politecnica de Valencia. The authors wish to thank the Spanish Ministry of Science and Innovation for the support provided through Projects BIA2012-32645 and RTI2018-099091-B-C21-AR, and Grant BES-2016-078010 from the European Union for the financial support with FEDER funds, and the Spanish Ministry of Education, Culture and Sport for Grant FPU12/01451.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Ductility of high-performance concrete and very-high-performance concrete elements with Ni-Ti reinforcements

  • Pereiro-Barceló, Javier
  • Goméz-Portillo, Salvador
  • Bonet Senach, José Luís|||0000-0002-6687-5307
  • Castro-Bugallo, M Carmen|||0000-0001-9201-6162
[EN] This article presents an experimental study on the behavior of high performance concrete (HPC) and very high performance concrete (VHPC) concrete columns with Nickel-Titanium (Ni-Ti) shape memory alloy (SMA) reinforcements in critical regions subjected to constant axial and lateral cyclic load combinations. These materials make the cast-in-place of concrete easier by reducing the amount of transverse reinforcement, improving performance, attenuating damage in critical regions, minimizing residual deformations and reducing repair costs in structures located in seismic areas. Seven experimental tests were carried out to analyze the behavior of this element type. A nonlinear static cyclic pushover analysis was performed with finite element software (OpenSees), whose results were compared with the experimental results. This analysis allowed a parametric analysis to be run to extrapolate the experimental results. Strength capacity was approximately 41.8% greater in absolute terms in the specimens manufactured with VHPC and 6.2% greater in a dimensional terms in those manufactured with HPC. Displacement ductility was 34.0% higher in the HPC specimens, and lowered with relative normal force and with transverse reinforcement separation. A residual drift ratio below 0.70% was generally observed when specimens reached 20% strength capacity loss. The residual drift ratio increased as a result of progressive concrete cover degradation, especially in the specimens manufactured with HPC. (C) 2018 Elsevier Ltd. All rights reserved., This article forms part of the research carried out at the Concrete Science and Technology Institute (ICITECH) of the Universitat Politecnica de Valencia (UPV). This work has been supported by the Spanish Ministry of Economy and Competitiveness through Project BIA2012-32645, and by the European Union through ERDF funds. The authors thank the Spanish Ministry of Education, Culture and Sport for Grant FPU12/01451.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Required tie spacing to prevent inelastic local buckling of longitudinal reinforcements in RC and FRC elements

  • Pereiro-Barceló, Javier
  • Bonet Senach, José Luís|||0000-0002-6687-5307
  • Albiol Ibáñez, José Ramón|||0000-0003-3049-9693
[EN] Compressed reinforcement buckling in concrete columns can reduce ductility in structural elements. In order to avoid this, design codes propose maximum required tie spacing. Nonetheless, they do not incorporate the positive effect of concrete fibers in their formulation, whose capability of delaying buckling has been proved. For this reason, recommendations for maximum required tie spacing for elements made with concrete, with or without steel fibers, and with normal or high strength, are proposed in this article. In order to achieve this, the mixed model proposed by Pereiro-Barceló and Bonet was extended to consider elements made of HSC with and without steel fibers thanks to the results of an experimental campaign of HSC columns with and without fibers, under monotonic loading. In these tests, the buckling critical load in compressed reinforcement was experimentally determined in all the columns. In addition, a comparison of the proposed transverse concrete separation with respect to the recommendations proposed by the main existing codes was made., The research presented herein forms part of a research undertaken at the Concrete Science and Technology Institute (ICITECH) of the Universitat Politecnica de Valencia (UPV). The authors are sincerely grateful to the Spanish Ministry of Economy and Competitiveness for the help provided through Project BIA2012-32645, and to the European Union for the financial support obtained from FEDER funds. The authors wish to thank the Spanish Ministry of Education, Culture and Sport for Grant FPU12/01451.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Buckling of steel and Ni-Ti reinforcements in very high performance concrete (VHPC) elements

  • Pereiro-Barceló, Javier
  • Bonet Senach, José Luís|||0000-0002-6687-5307
  • Albiol Ibáñez, José Ramón|||0000-0003-3049-9693
[EN] Nowadays, the use of new materials is becoming increasingly common in the construction world due to their improved properties. High or Very High Performance Concrete (HPC or VHPC) and Shape Memory Alloys (SMA), specifically those composed of nickel and titanium (Ni-Ti), are some of these new materials. The low austenitic modulus of Ni-Ti as regards the elasticity modulus of steel (40-65 GPa instead of 200 GPa) can cause local buckling. In order to replace steel bars with Ni-Ti bars in reinforced concrete elements, it is convenient to use concrete with a high steel fibre content to delay local bar buckling. Hence employing either High Performance Concrete or VHPC may be appropriate, due to its composition with a high steel fibre content. For all these reasons, VHPC elements with Ni-Ti reinforcements were studied. The results of an experimental campaign of VHPC columns are shown in this article. The VHPC columns were subjected to monotonic loading where the main goal was to study compressed steel reinforcement buckling. The results of these tests were also used to extend the mixed model proposed by Pereiro-Barceló and Bonet (2017), which determines the buckling critical stress for any transverse reinforcement separation and considers the effect of the concrete cover (with and without steel fibres). This model was recalibrated to consider elements made of VHPC. Besides, specimens made of either High Performance Concrete (HPC) or VHPC, and with Ni-Ti reinforcements, were also tested to study the behaviour of compressed Ni-Ti reinforcements in elements made of high strength fibre-reinforced concrete., The research presented herein forms part of a research undertaken at the Concrete Science and Technology Institute (ICITECH) of the Universitat Politecnica de Valencia (UPV). The authors are sincerely grateful to the Spanish Ministry of Economy and Competitiveness for the help provided through Project BIA2012-32645, and to the European Union for the financial support obtained from FEDER funds. The authors wish to thank the Spanish Ministry of Education, Culture and Sport for Grant FPU12/01451.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Cyclic response of precast column-to-foundation connection using UHPC and Ni-Ti SMA reinforcements in columns

  • Pereiro-Barceló, Javier
  • Bonet Senach, José Luís|||0000-0002-6687-5307
  • Rueda-García, Lisbel|||0000-0002-2061-1656
  • Albiol Ibáñez, José Ramón|||0000-0003-3049-9693
[EN] Earthquakes are catastrophic natural events with a special impact on reinforced concrete structures due to the horizontal loads that they introduce into structures. To adequately resist an earthquake, a precast structure must have a high deformation capacity, dissipate energy in each earthquake cycle, undergo less damage and fewer residual deformations. To achieve all this, the behaviour of precast columns made with UPHC was herein experimentally analysed. Steel rebars were replaced with Ni-Ti shape memory alloy (SMA) bars with super elasticity (SE) in the critical zone of the column-to-foundation connection. The Ni-Ti SMA bars crossed the interface between the column and foundation. Two types of connection with the foundation were studied: smooth pocket type and protruding bar type. Columns were subjected to constant compression and a cyclic lateral load. Rocking behaviour was observed at the connection critical section. The use of advanced materials allowed a moment-rotation behaviour of the connection to be developed without any significant damage. Low residual deformations were observed while testing because of both the damage in UHPC was low and the superelasticity of the Ni-Ti SMA bars., This paper forms part of a research line carried out at the Institute of Concrete Science and Technology (ICITECH) of the Universitat Politecnica de Valencia. The authors wish to thank to the Government of Spain Ministry of Economy and Competitiveness for the support it pro-vided through Project BIA2012-32645, to the Government of Spain Ministry of Science and Innovation for the project RTI2018-099091-B-C21-AR, and the grant BES-2016-078010, to the European Union for the financial support with FEDER funds and to the Government of Spain Ministry of Education, Culture and Sports for grant FPU12/01451.