Pasar al contenido principal

LASERES PARA LA CONSERVACION DEL PATRIMONIO

PID2022-137017OB-I00

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal para Impulsar la Investigación Científico-Técnica y su Transferencia
Subprograma Subprograma Estatal de Generación de Conocimiento
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2022
Plan Estatal 2021-2023 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario AGENCIA ESTATAL CONSEJO SUPERIOR DE INVESTIGACIONES CIENTIFICAS (CSIC)

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

SERS activity of silver-based calcium silicate hydrate upon laser irradiation

  • Maestro-Guijarro, Laura
  • Martínez-Ramírez, S.
  • Sánchez-Cortés, Santiago
  • Marco, J.F.
  • de la Figuera, Juan
  • Castillejo, Marta
  • Oujja, Mohamed
  • Carmona-Quiroga, Paula
C-S-H and C-S-Ag-H gel solutions were analysed by UV/Vis/NIR spectroscopy with a Shimadzu 3600 UV/Vis/NIR spectrometer equipped with 2H and Wlamps, a photomultiplier (UV/Vis), and a InGaAs and a PbS (NIR) detectors. The baseline reference sample was prepared with 1000 µL of MilliQ water. The samples were diluted 1:19 (50 μL of gel solution to 950 μL of of MilliQ water) and the measurements were recorded in the range of 190–850 nm, with slow scan speed. The sampling interval and the slit width were 0.5 nm and 1 nm, respectively. For the 29Si NMR analysis of dried C-S-H and C-S-Ag-H, a Bruker AV-400 (9.4 T and νR of 4 kHz) (Bruker, Germany) NMR spectrometer was used in the following conditions: pulse width of 7 μs and relaxation delay of 60 s with typically 3000 scans. The 29Si chemical shifts were determined relative to tetramethylsilane. The spectra were treated for band deconvolution into Gaussian peaks and fitted using Origin 2022 software. The micro-Raman spectra were carried out on pressed pellets of the samples with a Raman microscope Renishaw RM1000 (Renishaw, Wotton-under-Endge, UK) equipped with a Leica microscope and an electrically refrigerated CCD camera. Laser excitation line was provided by a He:Ne (633 nm wavelength, 25 mW output power with approximately 2 mW at the sample). The spectra were obtained using a 50× magnification objective, a spectral resolution of 4 cm−1, a 10 s exposure time, 5 accumulations, and 2mW laser power per spectra in the range of 2000–100 cm−1 in order to increase signal/noise ratio. The frequencies were calibrated with silicon at 520 cm−1. X-ray photoelectron (XP) and SERS spectra were taken on pressed C-S-Ag-H pellets before and after irradiation at 355 nm, and 532 nm (and of the reference C-S-H pellet). For the former technique, the analysis was performed under a base pressure lower than 7.5 · 10−9 Torr using a PHOIBOS-150 (Specs) electron analyzer, Mg Kα radiation and a constant pass energy of 100 eV and 20 eV for the wide and narrow scans, respectively. The pellets were fixed to the sample holder using double-sided conductive carbon tape to ensure a good conductivity and the X-ray gun was used at 100 W power in order to avoid any possible sample degradation induced by the X-ray irradiation. The binding energy scale was referenced to the main C 1s signal of the adventitious carbon contamination layer which was set at 284.8 eV. All the spectra were fitted using pseudo-Voigt lines (30 % Gaussian/70 % Lorentzian) and a Shirley-type background. For the SERS analysis, the same experimental conditions were used as for obtaining the Raman spectra using Rhodamine B as a probe molecule (an aliquot of 2 µl of a 5 × 10−6 M aqueous solution was dropped on the irradiated and on the non-irradiated silver-containing pellets). Additionally, different reference RhB spectra were acquired on hydroxylamine-reduced silver nanoparticles (NPs), 2 µl dropped on top of both C-S-H and C-S-Ag-H pellets for the comparison of the SERS activities. More details about samples preparation and irradiation conditions are available in Materials folder., Data life: 2024- (unlimited validity), This is the experimental dataset used in the paper Applied Surface Science, 662: 160107 (2024) (https://doi.org/10.1016/j.apsusc.2024.160107) in which a novel Surface-Enhanced Raman Spectroscopy (SERS) sensor based on a nanostructured substrate, calcium silicate hydrate (C-S-H), the main hydration product of Portland cement, was synthetized. The procedure involves first the incorporation of silver within the nanostructure of the gel (C-S-Ag-H) and second the modification of the surface of pellets of the newly synthesized material by laser irradiation at 532 nm or 355 nm. This data set includes the results of the effect of silver on the gel structure via visible UV spectroscopy, micro-Raman and 29Si Magic Angle Spinning Nuclear Magnetic Resonance (MAS NMR). It also includes the characterization analyses of the C-S-Ag-H pellets by X-ray Photoelectron Spectroscopy (XPS) to determine the silver oxidation state and the assessment of their SERS activity before and after laser irradiation using for the latter Rhodamine B (RhB) as a probe., We acknowledge financial support from the Spanish State Research Agency (AEI) through projects PID2019-104124RB-I00/AEI/10.13039/501100011033; PID2020-113900RB-I00/AEI/10.13039/ 501100011033; and PID2022-137017OB-I00/AEI/10.13039/501100011033; from European Union’s Horizon 2020 through IPERION HS (Integrated Platform for the European Research Infrastructure ON Heritage Science, GA 871034) project; and from the Community of Madrid through Maestro-Guijarro’s Youth Guarantee contract (CAM20_IQFR_AI_06)., Materials folder: “Sample_synthesis”; “Laser_irradiation_conditions” NMR folder: "NMR_readme"; "NMR_C-S-H"; "NMR_C-S-Ag-H" Raman folder: “Raman_readme"; "Raman_C-S-H"; "Raman_C-S-Ag-H"; "Raman_C-S-H_RhB"; "Raman_C-S-Ag-H_RhB" SERS folder: "SERS_readme"; "SERS_RhB_C-S-Ag-H_355"; "SERS_RhB_C-S-Ag-H_355_NPs"; "SERS_RhB_C-S-Ag-H_532"; "SERS_RhB_C-S-Ag-H_532_NPs"; "SERS_RhB_C-S-Ag-H_NPs"; "SERS_RhB_C-S-H_NPs" XPS folder: "XPS_readme"; "XPS_AgAuger_C-S-Ag-H_532"; "XPS_AgAuger_C-S-Ag-H_355"; "XPS_Ag3d_C-S-Ag-H_532"; "XPS_Ag3d_C-S-Ag-H_355"; "XPS_Ag3d_C-S-Ag-H"; "XPS_Ag3d_C-S-H"; "XPS_Ca2p_C-S-Ag-H_532"; "XPS_C1s_C-S-Ag-H_532"; "XPS_wide_C-S-Ag-H_532"; "XPS_wide_C-S-Ag-H_355"; "XPS_wide_C-S-Ag-H"; "XPS_wide_C-S-H" UV-Vis folder: "UV-VIS_readme"; "UV-VIS_C-S-H"; "UV-VIS_C-S-Ag-H", Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Determination of Boron Content in Enamel and Grisaille Paintings from Stained-Glass Windows [Dataset]

  • Maestro-Guijarro, Laura
  • Sedano, Mercedes
  • Schibille, Nadine
  • Pradell, Trinitat
  • Castillejo, Marta
  • Oujja, Mohamed
  • Palomar Sanz, Teresa
All samples (reference glasses, replica enamels, and historical grisailles and enamels) were analyzed by LA-ICP-MS. These analyses were carried out at IRAMAT-CEB in Orléans (France). The analyses were done using a Resonetics M50E excimer laser (ArF, 193 nm) equipped with a S155 ablation cell and a Thermo Fisher Scientific ELEMENT XR mass spectrometer system. The ablations were typically carried out with a 5 mJ energy at 10 Hz pulse frequency in spot-mode and a beam diameter of 100 microns for the base glass. The enamels were typically analysed on the surface due to insufficient thickness with a beam diameter of 50 microns that was occasionally reduced down to 25 microns when saturation of the signal caused by high concentrations of transition metals occurred. A pre-ablation time of either 10 s or 20 s depending on the thickness of the sample was followed by 30 s signal acquisition, resulting in 10 mass scans. The ablated material is transported to the plasma torch by an argon/helium flow at an approximate rate of 1 L/ min for Ar and 0.65 L/min for He. The ion signals in counts-persecond are recorded for 58 isotopes (from Li to U). Standard Reference Material (NIST SRM610), as well as Corning glasses B, C, and D and APL1 (in-house standard glass), were used for external calibration, while 28Si was used as internal standard. Quantitative concentrations were calculated based on the procedures described by Gratuze, B., Blet-Lemarquand, M. & Barrandon, JN. J. Radioanal. Nucl. Chem. 247, 645–656 (2001). https://doi.org/10.1023/A:1010623703423. Precision and accuracy are reflected in the repeated measurements of reference glasses Corning A and NIST SRM612. LIBS analyses of all samples including reference glasses, replica enamels, and historical grisailles and enamels were carried out, at ambient atmospheric conditions, on the surface and in-depth (stratigraphic study) of the considered glass samples using laser excitation at 266 nm (4th harmonic of a Q-switched Nd: YAG laser (Lotis TII, LS-2147), 15 ns pulses, 1 Hz repetition rate). LIB spectra were recorded using a 0.2 m Czerny-Turner spectrograph (Andor, Shamrock Kymera-193i-A) equipped with a grating of 1800 grooves/mm (blazed at 265 nm) and coupled to a time-gated intensified charge-coupled device (ICCD) camera (Andor Technology, iStar CCD 334, 1024x1024 active pixels, 13 µm x 13 µm pixel). The ICCD detector is synchronized with the Q-Switch output electrical signal that triggers the laser pulse. The laser beam was directed to the surface of the samples by the use of mirrors at an incidence angle of 45°. Focusing with a 10 cm focal length lens allowed fluences in the range of 5–9 J/cm2 to be achieved. The shot-to-shot laser energy fluctuation was less than 10%. LIB spectra were recorded in the 240–600 nm wavelength range using a step and glow mode at intervals of 30 nm. For the stratigraphic analysis, the spectra were recorded by applying several laser pulses in the same area of the samples at 30 nm wavelength intervals centered at 285, 325, 360, 400 and 500 nm. The spectra were acquired at a 0.17 nm resolution with a gate delay and width of 200 nanoseconds and 3 microseconds, respectively. For higher wavelengths, a cut-off filter at 300 nm was placed in front of the entrance window of the spectrograph to reduce the scattered laser light and to avoid second-order diffractions. Each LIB spectrum resulted from a single signal acquisition as it provides good signal/noise ratios. An optical profilometer model Zeta-20 True color 3D from Zeta Instruments was used to perform the optical profiles on the pits produced by LIBS analyses in replica and historical samples. For profiling measurements, an x20 objective was used. The data were processed with Zeta View software during the acquisition and Gwyddion 2.67 software to select, and represent the final data., This is the experimental dataset used in the paper Chemistry-Methods, e202400057 (2025) (https://doi.org/10.1002/cmtd.202400057) in which quantitative information on historical Spanish enamels and grisailles was obtained from calibration curves generated from the model glass samples with known boron content. The procedure involves the compositional analyses of model glass samples (with well-known boron content), replica and historical materials using Laser Ablation Inductively Coupled Plasma Mass Spectrometry (LA-ICP-MS) and Laser Induced Breakdown Spectroscopy (LIBS). Two methods for calibration curves were established based on LIBS and LA-ICP-MS analyses. In the first, the ratio of the corresponding relative intensities of boron and silicon with lead determined by LIBS measurements was represented as a function of the boron content (in wt %) measured by LA-ICP-MS. On the other hand, in the second approach, the ratio of the relative intensities of boron and silicon with lead obtained by LIBS was represented as a function of the ratio between the amount of boron and silicon with lead obtained by LA-ICP-MS. This data set includes the compositional results provided by LIBS and LA-ICP-MS, the in-depth LIBS analyses useful for studying boron degradation profiling, and the calibration curves. It also includes the images and optical profiles of the imprint left on the analyzed samples after laser irradiation observed using optical profilometry., We acknowledge financial support from: Fundação de Ciência e Tecnologia from Portugal (project ref. UIDB/EAT/00729/2020, UIDP/00729/2020, 2023.05135.RESTART, and researcher grant CEECIND/02249/2021); the Spanish State Research Agency (AEI) through projects PID2022-137017OB-I00/AEI/1013039/501100011033 and PID2022-137783OB-I00; the Regional Government of Madrid through the project TEC Heritage-CM (TEC-2024/TEC-39); and the Generalitat de Catalunya through the Consolidated Group 2021 SGR 00343. Support from CSIC Platform' Open Heritage: Research and Society’ (PTI-PAIS) and the CSIC Open Access Publication Support Initiative through its Unit of Information Resources for Research (URICI) are also acknowledged. T. Palomar thanks MICIU for Ramón y Cajal contract (RYC2023-045699-I)., Samples folder: “Sample_description”; “Reference_mock-up_samples_preparation”OM and Profilometry folder: "OM_and_profilometry_readme"; "BC3B-blue"; "BC3B-purple"; "E3-yellow"; "E131-blue”; “Profilometry_BC3B-blue"; "Profilometry_BC3B-purple"; "Profilometry_E3-yellow"; "Profilometry_E131-blue"LIBS folder: “LIBS_readme"; "LIBS_reference"; "LIBS_BC3B-purple_A"; "LIBS_BC3B-purple_B"; "LIBS_E107-purple_A"; "LIBS_E107-purple_B"; "LIBS_stratigraphic_E131-blue_A"; "LIBS_stratigraphic_E131-blue_C"; "LIBS_stratigraphic_EN1 C-yellow_B"; "LIBS_stratigraphic_EN1 C-yellow_D" LA-ICP-MS folder: "LA-ICP-MS_readme"; "LA-ICP-MS_Reference"; "LA-ICP-MS_Replica"; "LA-ICP-MS_Historical"Calibration curves folder: "Calibration_curves_readme"; "Calibration curves_First approach"; "Calibration curves_Second approach", Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Analysis of glass beads from Cultural Heritage for authentication purposes [Dataset]

  • Maestro-Guijarro, Laura
  • Pinilla Gisbert, Alejandro
  • Carmona-Quiroga, Paula
  • Agua Martínez, Fernando
  • Castillejo, Marta
  • García Heras, Manuel
  • Oujja, Mohamed
  • Villegas Broncano, María Ángeles
The considered glass beads were compositionally characterized using a multi-analytical approach. FESEM examinations were accomplished on polished surfaces and fractures, as well as on cross-sections inlayed into cold-setting epoxy resin and later mirror-polished using an aqueous suspension of cerium oxide. The FESEM employed was a Hitachi S-4800 cold cathode equipment, working with acceleration voltages of 7 and 15 kV. A 20 mm2 Oxford X-Max system coupled to the electron microscope with a resolution of 125 eV (Mn Kα) was used for EDS microanalyses. Samples were previously sputter-coated with graphite on a JEOL JEE4b vaporizer to make them conductive. Laser-induced Breakdown Spectrocopy (LIBS) analyses were performed using laser excitation at 266 nm (4th harmonic of a Q-switched Nd: YAG laser (Lotis TII, LS-2147), 15 ns pulses, 1 Hz repetition rate). LIB spectra were recorded using a 0.2 m Czerny-Turner spectrograph (Andor, Shamrock Kymera-193i-A) equipped with a grating of 1800 grooves/mm (blazed at 265 nm) and coupled to a time-gated intensified charge-coupled device (ICCD) camera (Andor Technology, iStar CCD 334, 1024x1024 active pixels, 13 µm x 13 µm pixel). The ICCD detector is synchronized with the Q-Switch output electrical signal that triggers the laser pulse. The laser beam was directed to the surface of the samples by the use of mirrors at an incidence angle of 45°. Focusing with a 10 cm focal length lens allowed fluences in the range of 9–15 J/cm2. LIB spectra were recorded in the 240–600 nm wavelength range using a step and glow mode at intervals of 30 nm. The spectra were acquired at a 0.17 nm resolution with a gate delay and width of 200 nanoseconds and 3 microseconds, respectively. For higher wavelengths, a cut-off filter at 300 nm was placed in front of the entrance window of the spectrograph to reduce the scattered laser light and to avoid second-order diffractions. An Ocean Optics HR 4000 CG equipment was used for UV–Vis spectrophotometry. Spectra were acquired by absorption or reflection and recorded in the 200–1000 nm wavelength range. XRF analysis was recorded with a PANalytical instrument, model Magi-X, of wavelength dispersion provided with an X-ray tube of rhodium anode (2.4 kW). Analytical recordings were accomplished using the IQ + software (PANalytical) based on fundamental patterns of synthetic oxides and natural minerals. Samples were prepared in a Perl’X3 Philips instrument starting from the powdered glasses and compacting them as pearls by melting at 1100 ºC (homogeneous mixture of 0.3 g of powdered glass with 5.5 g Li2B4O7). Data life: 2025- (unlimited validity), This is the experimental dataset used in the paper Talanta, 286: 127510 (2025) (http://hdl.handle.net/10261/380008) in which through a multi-analytical approach modern and historic glass beads are analysed to provide markers that allows unmasking imitations, counterfeiting, and forgerie. In total 9 historical glass beads (H-01 to H-09) from archaeological excavations in Spain and Mozambique (Late iron age, 7th and 12th century AD) and 12 modern glass beads (M-01 to M-12) of similar colour and transparency than the historical one were analysed via X-ray Fluorescence (XRF), Field Emission Scanning Electron Microscopy-Energy Dispersive X-ray Spectroscopy (FESEM-EDS), UV-Vis spectrophotometry, X-ray diffraction (XRD), and Laser Induced Breakdown Spectroscopy (LIBS). This data set includes the results of their chemical characterization., This research has been funded by MCIN/AEI/10.13039/501100011033/FEDER, UE through the project PID2022-137017OBI00 and by the Regional Government of Madrid through the project TEC Heritage-CM (TEC-2024/TEC-39). A. Pinilla acknowledges a PhD contract from the Regional Government of Madrid (PIPF-2023/PH-HUM-29465)., GLASS BEADS: Glass_beads_readme.txt, H-01.jpg, H-02.jpg, H-03.jpg, H-04.jpg, H-05.jpg, H-06.jpg, H-07.jpg, H-08.jpg, H-09.jpg, M-01.jpg, M-02.jpg, M-03.jpg, M-04.jpg, M-05.jpg, M-06.jpg, M-07.jpg, M-08.jpg, M-09.jpg, M-10.jpg, M-11.jpg, M-12.jpg FESEM-EDS folder: FESEM-EDS_readme.txt, EDS_H.csv, EDS_Microzones.csv, FESEM_H-01.tif, FESEM_H-03.tif, FESEM_H-08.tif, FESEM_H-09.tif, FESEM_M-09.jpg, FESEM_M-10.jpg, FESEM_M-11-A.jpg, FESEM_M-11-B.jpg LIBS folder: LIBS_readme.txt, LIBS_H-01.csv, LIBS_H-02.csv, LIBS_H-03_black.csv, LIBS_H-03_white.csv LIBS_H-04.csv, LIBS_H-05.csv, LIBS_H-06.csv, LIBS_H-07.csv, LIBS_H-08.csv, LIBS_H-09.csv, LIBS_M-01.csv, LIBS_M-02.csv, LIBS_M-03.csv, LIBS_M-04.csv, LIBS_M-05.csv, LIBS_M-06.csv, LIBS_M-07.csv, LIBS_M-08.csv, LIBS_M-09.csv, LIBS_M-10_core.csv, LIBS_M-10_surface.csv, LIBS_M-11.csv, LIBS_M-12.csv UV-VIS folder: UV-VIS_readme.txt, UV-VIS_H-01.csv, UV-VIS_H-02.csv, UV-VIS_H-04.csv, UV-VIS_H-06.csv, UV-VIS_H-08.csv, UV-VIS_M-01.csv, UV-VIS_M-02.csv, UV-VIS_M-03.csv, UV-VIS_M-04.csv, UV-VIS_M-05.csv, UV-VIS_M-06.csv, UV-VIS_M-07.csv, UV-VIS_M-08.csv, UV-VIS_M-12.csv XRF folder: XRF_readme.txt, XRF_M.csv O, Peer reviewed