Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 8
Encontrada(s) 1 página(s)

Docta Complutense
Publicación Artículo científico (JournalArticle)

Classification of kinematic and electromyographic signals associated with pathological tremor using machine and deep learning

  • Pascual Valdunciel, Alejandro
  • Lopo Martinez, Victor
  • Beltran Carrero, Alberto J.
  • Sendra Arranz, Rafael
  • González Sánchez, Miguel
  • Perez Sanchez, Javier Ricardo
  • Grandas Pérez, Francisco Javier
  • Farina, Dario
  • Pons, José L.
  • Oliveira Barroso, Filipe
  • Gutierrez, Álvaro
Peripheral Electrical Stimulation (PES) of afferent pathways has received increased interest as a solution to reduce pathological tremors with minimal side effects. Closed-loop PES systems might present some advantages in reducing tremors, but further developments are required in order to reliably detect pathological tremors to accurately enable the stimulation only if a tremor is present. This study explores different machine learning (K-Nearest Neighbors, Random Forest and Support Vector Machines) and deep learning (Long Short-Term Memory neural networks) models in order to provide a binary (Tremor; No Tremor) classification of kinematic (angle displacement) and electromyography (EMG) signals recorded from patients diagnosed with essential tremors and healthy subjects. Three types of signal sequences without any feature extraction were used as inputs for the classifiers: kinematics (wrist flexion-extension angle), raw EMG and EMG envelopes from wrist flexor and extensor muscles. All the models showed high classification scores (Tremor vs. No Tremor) for the different input data modalities, ranging from 0.8 to 0.99 for the f(1) score. The LSTM models achieved 0.98 f(1) scores for the classification of raw EMG signals, showing high potential to detect tremors without any processed features or preliminary information. These models may be explored in real-time closed-loop PES strategies to detect tremors and enable stimulation with minimal signal processing steps.
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

First-in-human demonstration of floating EMG sensors and stimulators wirelessly powered and operated by volume conduction

  • Becerra Fajardo, Laura
  • Minguillon, Jesus
  • Krob, Marc Oliver
  • Rodrigues, Camila
  • González Sánchez, Miguel
  • Megía-García, Álvaro
  • Redondo Galán, Carolina
  • Gutiérrez Henares, Francisco
  • Comerma-Montells, Albert
  • Del-Alma, Antonio J.
  • Gil-Agudo, Ángel
  • Grandas, Francisco
  • Schneider-Ickert, Andreas
  • Barroso, Filipe O.
  • Ivorra Cano, Antoni, 1974-
Background: Recently we reported the design and evaluation of floating semi-implantable devices that receive power from and bidirectionally communicate with an external system using coupling by volume conduction. The approach, of which the semi-implantable devices are proof-of-concept prototypes, may overcome some limitations presented by existing neuroprostheses, especially those related to implant size and deployment, as the implants avoid bulky components and can be developed as threadlike devices. Here, it is reported the first-in-human acute demonstration of these devices for electromyography (EMG) sensing and electrical stimulation. Methods: A proof-of-concept device, consisting of implantable thin-film electrodes and a nonimplantable miniature electronic circuit connected to them, was deployed in the upper or lower limb of six healthy participants. Two external electrodes were strapped around the limb and were connected to the external system which delivered high frequency current bursts. Within these bursts, 13 commands were modulated to communicate with the implant. Results: Four devices were deployed in the biceps brachii and the gastrocnemius medialis muscles, and the external system was able to power and communicate with them. Limitations regarding insertion and communication speed are reported. Sensing and stimulation parameters were configured from the external system. In one participant, electrical stimulation and EMG acquisition assays were performed, demonstrating the feasibility of the approach to power and communicate with the floating device. Conclusions: This is the first-in-human demonstration of EMG sensors and electrical stimulators powered and operated by volume conduction. These proof-of-concept devices can be miniaturized using current microelectronic technologies, enabling fully implantable networked neuroprosthetics., This work has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No. 779982 (Project EXTEND - Bidirectional Hyper-Connected Neural System). CR has been also partially funded by CSIC Interdisciplinary Thematic Platform (PTI+) NEURO-AGINGl+ (PTI-NEURO-AGING+). FOB thanks the financial support from the Spanish MCIN/AEI/https://doi.org/10.13039/501100011033 and by the “European Union NextGenerationEU/PRTR” under Grant agreement IJC2020-044467-I. AI gratefully acknowledges the financial support by ICREA under the ICREA Academia programme.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Benchmarking the Effects on Human–Exoskeleton Interaction of Trajectory, Admittance and EMG-Triggered Exoskeleton Movement Control

  • Rodrigues-Carvalho, C.
  • Fernández-García,M.
  • Pinto-Fernández, David
  • Sanz-Morere, C.
  • Barroso, Filipe O.
  • Borromeo, S.
  • Rodríguez-Sánchez, C.
  • Moreno, Juan Camilo
  • Del-Ama, Antonio J.
Nowadays, robotic technology for gait training is becoming a common tool in rehabilitation hospitals. However, its effectiveness is still controversial. Traditional control strategies do not adequately integrate human intention and interaction and little is known regarding the impact of exoskeleton control strategies on muscle coordination, physical effort, and user acceptance. In this article, we benchmarked three types of exoskeleton control strategies in a sample of seven healthy volunteers: trajectory assistance (TC), compliant assistance (AC), and compliant assistance with EMG-Onset stepping control (OC), which allows the user to decide when to take a step during the walking cycle. This exploratory study was conducted within the EUROBENCH project facility. Experimental procedures and data analysis were conducted following EUROBENCH’s protocols. Specifically, exoskeleton kinematics, muscle activation, heart and breathing rates, skin conductance, as well as user-perceived effort were analyzed. Our results show that the OC controller showed robust performance in detecting stepping intention even using a corrupt EMG acquisition channel. The AC and OC controllers resulted in similar kinematic alterations compared to the TC controller. Muscle synergies remained similar to the synergies found in the literature, although some changes in muscle contribution were found, as well as an overall increase in agonist-antagonist co-contraction. The OC condition led to the decreased mean duration of activation of synergies. These differences were not reflected in the overall physiological impact of walking or subjective perception. We conclude that, although the AC and OC walking conditions allowed the users to modulate their walking pattern, the application of these two controllers did not translate into significant changes in the overall physiological cost of walking nor the perceived experience of use. Nonetheless, results suggest that both AC and OC controllers are potentially interesting approaches that can be explored as gait rehabilitation tools. Furthermore, the INTENTION project is, to our knowledge, the first study to benchmark the effects on human–exoskeleton interaction of three different exoskeleton controllers, including a new EMG-based controller designed by us and never tested in previous studies, which has made it possible to provide valuable third-party feedback on the use of the EUROBENCH facility and testbed, enriching the apprenticeship of the project consortium and contributing to the scientific community., The work presented here was supported by European Union’s Horizon 2020 research and innovation program under grant agreement No 779963, project EUROBENCH (European Robotic Framework for Bipedal Locomotion Benchmarking) through the FSTP-2 project INTENTION (Improving Human–Robot Interaction through EMG-Onset Controller for Lower Limb Exoskeletons). Camila Rodrigues-Carvalho has also been partially funded by CSIC Interdisciplinary Thematic Platform (PTI+) NEURO-AGINGl+ (PTI-NEURO-AGING+). This work was also partially funded by the Spanish MCIN/AEI/ 10.13039/501100011033 and by “European Union NextGenerationEU/PRTR”, under Grant agreement IJC2020-044467-I., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Modulation of spinal circuits following phase-dependent electrical stimulation of afferent pathways

  • Pascual-Valdunciel, Alejandro
  • Kurukuti, N.M.
  • Montero-Pardo, Cristina
  • Barroso, Filipe O.
  • Pons Rovira, José Luis
Objective. Peripheral electrical stimulation (PES) of afferent pathways is a tool commonly used to induce neural adaptations in some neural disorders such as pathological tremor or stroke. However, the neuromodulatory effects of stimulation interventions synchronized with physiological activity (closed-loop strategies) have been scarcely researched in the upper-limb. Here, the short-term spinal effects of a 20-minute stimulation protocol where afferent pathways were stimulated with a closed-loop strategy named selective and adaptive timely stimulation (SATS) were explored in 11 healthy subjects. Approach. SATS was applied to the radial nerve in-phase (INP) or out-of-phase (OOP) with respect to the muscle activity of the extensor carpi radialis (ECR). The neural adaptations at the spinal cord level were assessed for the flexor carpi radialis (FCR) by measuring disynaptic Group I inhibition, Ia presynaptic inhibition, Ib facilitation from the H-reflex and estimation of the neural drive before, immediately after, and 30 minutes after the intervention. Main results. SATS strategy delivered electrical stimulation synchronized with the real-time muscle activity measured, with an average delay of 17 ± 8 ms. SATS-INP induced increased disynaptic Group I inhibition (77 ± 23% of baseline conditioned FCR H-reflex), while SATS-OOP elicited the opposite effect (125 ± 46% of baseline conditioned FCR H-reflex). Some of the subjects maintained the changes after 30 minutes. No other significant changes were found for the rest of measurements. Significance. These results suggest that the short-term modulatory effects of phase-dependent PES occur at specific targeted spinal pathways for the wrist muscles in healthy individuals. Importantly, timely recruitment of afferent pathways synchronized with specific muscle activity is a fundamental principle that shall be considered when tailoring PES protocols to modulate specific neural circuits. (NCT number 04501133)., This study was funded by the European Union's Horizon 2020 research and innovation program (EXTEND—Bidirectional Hyper-Connected Neural System, Agreement No 779982). This work was partially funded by the Spanish MCIN/AEI/ 10.13039/501100011033 and by the European Union NextGenerationEU/PRTR, under Grant Agreement IJC2020-044467-I.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Muscle synergies analysis shows altered neural strategies in women with patellofemoral pain during walking

  • Ferreira, C.L.
  • Barroso, Filipe O.
  • Torricelli, Diego
  • Pons, José Luis
  • Politti, F.
  • Lucareli, P.R.G.
Several studies suggest that the central nervous system coordinates muscle activation by modulating neural commands directed to groups of muscles combined to form muscle synergies. Individuals with patellofemoral pain (PFP) move differently from asymptomatic individuals. Understanding the neural strategies involved in the execution of tasks such as walking can help comprehend how the movement is planned and better understand this clinical condition. The objective of this study was to compare muscle synergies between women with and without PFP during walking. Eleven women with PFP and thirteen asymptomatic women were assessed using three-dimensional kinematics and electromyography (EMG) while walking at self-selected speed. Kinematics of the trunk, pelvis and lower limbs were analyzed through the Movement Deviation Profile. Muscle synergies were extracted from the EMG signals of eight lower limb muscles collected throughout the whole gait cycle. Kinematic differences between the two groups (p<0.001, z-score = 3.06) were more evident during loading response, terminal stance, and pre-swing. PFP group presented a lower number of muscle synergies (p = 0.037), and greater variability accounted for (VAF) when using 3 (p = 0.017), 4 (p = 0.004), and 5 (p = 0.012) synergies to reconstruct all EMG signals. The PFP group also presented higher VAF for rectus femoris (p = 0.048) and gastrocnemius medialis (p = 0.019) when considering 4 synergies. Our results suggest that women with PFP show lower motor complexity and deficit in muscle coordination to execute gait, indicating that gait in PFP is the result of different neural commands compared to asymptomatic women., This work was supported by the European Union’s Horizon 2020 research and innovation programme (Project EXTEND—Bidirectional Hyper-Connected Neural System) under Grant 779982 and by the Spanish MCIN/AEI/10.13039/501100011033 and the “European Union NextGenerationEU/PRTR” under Grant agreement IJC2020-044467-I and by The National Council for Scientific and Technological Development – CNPq under Grant 310680/2022-0., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Dataset - Muscle synergies analysis shows altered neural strategies in women with patellofemoral pain during walking

  • Oliveira Barroso, F.
Several studies suggest that the central nervous system coordinates muscle activation by modulating neural commands directed to groups of muscles combined to form muscle synergies. Individuals with patellofemoral pain (PFP) move differently from asymptomatic individuals. Understanding the neural strategies involved in the execution of tasks such as walking can help comprehend how the movement is planned and better understand this clinical condition. The objective of this study was to compare muscle synergies between women with and without PFP during walking. Eleven women with PFP and thirteen asymptomatic women were assessed using three-dimensional kinematics and electromyography (EMG) while walking at self-selected speed. Kinematics of the trunk, pelvis and lower limbs were analyzed through the Movement Deviation Profile. Muscle synergies were extracted from the EMG signals of eight lower limb muscles collected throughout the whole gait cycle. Kinematic differences between the two groups (p<0.001, z-score = 3.06) were more evident during loading response, terminal stance, and pre-swing. PFP group presented a lower number of muscle synergies (p = 0.037), and greater variability accounted for (VAFtotal) when using 3 (p = 0.017), 4 (p = 0.004), and 5 (p = 0.012) synergies to reconstruct all EMG signals. The PFP group also presented higher VAFmuscle for rectus femoris (p = 0.048) and gastrocnemius medialis (p = 0.019) when considering 4 synergies. Our results suggest that women with PFP show lower motor complexity and deficit in muscle coordination to execute gait, indicating that gait in PFP is the result of different neural commands compared to asymptomatic women., This work was supported by the European Union’s Horizon 2020 research and innovation programme (Project EXTEND— Bidirectional Hyper-Connected Neural System) under Grant 779982 and by the Spanish MCIN/AEI/ 10.13039/501100011033 and the “European Union NextGenerationEU/PRTR” under Grant agreement IJC2020-044467-I and by The National Council for Scientific and Technological Development– CNPq under Grant 310680/2022-0.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

First-in-human demonstration of floating EMG sensors and stimulators wirelessly powered and operated by volume conduction

  • Becerra-Fajardo, L.
  • Minguillon, J.
  • Krob, M.O.
  • Rodrigues, C.
  • González-Sánchez, M.
  • Megía-García, Á.
  • Galán, C.R.
  • Henares, F.G.
  • Comerma, A.
  • Del-Ama, Antonio J.
  • Gil-Agudo, Á.
  • Grandas, Francisco
  • Barroso, Filipe O.
  • Ivorra, A.
Background: Recently we reported the design and evaluation of floating semi-implantable devices that receive power from and bidirectionally communicate with an external system using coupling by volume conduction. The approach, of which the semi-implantable devices are proof-of-concept prototypes, may overcome some limitations presented by existing neuroprostheses, especially those related to implant size and deployment, as the implants avoid bulky components and can be developed as threadlike devices. Here, it is reported the first-in-human acute demonstration of these devices for electromyography (EMG) sensing and electrical stimulation. Methods: A proof-of-concept device, consisting of implantable thin-film electrodes and a nonimplantable miniature electronic circuit connected to them, was deployed in the upper or lower limb of six healthy participants. Two external electrodes were strapped around the limb and were connected to the external system which delivered high frequency current bursts. Within these bursts, 13 commands were modulated to communicate with the implant. Results: Four devices were deployed in the biceps brachii and the gastrocnemius medialis muscles, and the external system was able to power and communicate with them. Limitations regarding insertion and communication speed are reported. Sensing and stimulation parameters were configured from the external system. In one participant, electrical stimulation and EMG acquisition assays were performed, demonstrating the feasibility of the approach to power and communicate with the floating device. Conclusions: This is the first-in-human demonstration of EMG sensors and electrical stimulators powered and operated by volume conduction. These proof-of-concept devices can be miniaturized using current microelectronic technologies, enabling fully implantable networked neuroprosthetics., This work has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No. 779982 (Project EXTEND - Bidirectional Hyper-Connected Neural System). CR has been also partially funded by CSIC Interdisciplinary Thematic Platform (PTI+) NEURO-AGINGl+ (PTI-NEURO-AGING+). FOB thanks the financial support from the Spanish MCIN/AEI/https://doi.org/10.13039/501100011033 and by the “European Union NextGeneration EU/PRTR” under Grant agreement IJC2020-044467-I. AI gratefully acknowledges the financial support by ICREA under the ICREA Academia programme.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

First-in-human demonstration of floating EMG sensors and stimulators wirelessly powered and operated by volume conduction

  • Becerra Fajardo, Laura
  • Minguillon, Jesus
  • Krob, Marc Oliver
  • Rodrigues, Camila
  • González Sánchez, Miguel
  • Megía-García, Álvaro
  • Redondo Galán, Carolina
  • Gutiérrez Henares, Francisco
  • Comerma-Montells, Albert
  • Del-Alma, Antonio J.
  • Gil-Agudo, Ángel
  • Grandas, Francisco
  • Schneider-Ickert, Andreas
  • Barroso, Filipe O.
  • Ivorra Cano, Antoni, 1974-
Background: Recently we reported the design and evaluation of floating semi-implantable devices that receive power from and bidirectionally communicate with an external system using coupling by volume conduction. The approach, of which the semi-implantable devices are proof-of-concept prototypes, may overcome some limitations presented by existing neuroprostheses, especially those related to implant size and deployment, as the implants avoid bulky components and can be developed as threadlike devices. Here, it is reported the first-in-human acute demonstration of these devices for electromyography (EMG) sensing and electrical stimulation. Methods: A proof-of-concept device, consisting of implantable thin-film electrodes and a nonimplantable miniature electronic circuit connected to them, was deployed in the upper or lower limb of six healthy participants. Two external electrodes were strapped around the limb and were connected to the external system which delivered high frequency current bursts. Within these bursts, 13 commands were modulated to communicate with the implant. Results: Four devices were deployed in the biceps brachii and the gastrocnemius medialis muscles, and the external system was able to power and communicate with them. Limitations regarding insertion and communication speed are reported. Sensing and stimulation parameters were configured from the external system. In one participant, electrical stimulation and EMG acquisition assays were performed, demonstrating the feasibility of the approach to power and communicate with the floating device. Conclusions: This is the first-in-human demonstration of EMG sensors and electrical stimulators powered and operated by volume conduction. These proof-of-concept devices can be miniaturized using current microelectronic technologies, enabling fully implantable networked neuroprosthetics., This work has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No. 779982 (Project EXTEND - Bidirectional Hyper-Connected Neural System). CR has been also partially funded by CSIC Interdisciplinary Thematic Platform (PTI+) NEURO-AGINGl+ (PTI-NEURO-AGING+). FOB thanks the financial support from the Spanish MCIN/AEI/https://doi.org/10.13039/501100011033 and by the “European Union NextGenerationEU/PRTR” under Grant agreement IJC2020-044467-I. AI gratefully acknowledges the financial support by ICREA under the ICREA Academia programme.