Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 43
Encontrada(s) 1 página(s)

Docta Complutense
Publicación Artículo científico (JournalArticle)

Classification of kinematic and electromyographic signals associated with pathological tremor using machine and deep learning

  • Pascual Valdunciel, Alejandro
  • Lopo Martinez, Victor
  • Beltran Carrero, Alberto J.
  • Sendra Arranz, Rafael
  • González Sánchez, Miguel
  • Perez Sanchez, Javier Ricardo
  • Grandas Pérez, Francisco Javier
  • Farina, Dario
  • Pons, José L.
  • Oliveira Barroso, Filipe
  • Gutierrez, Álvaro
Peripheral Electrical Stimulation (PES) of afferent pathways has received increased interest as a solution to reduce pathological tremors with minimal side effects. Closed-loop PES systems might present some advantages in reducing tremors, but further developments are required in order to reliably detect pathological tremors to accurately enable the stimulation only if a tremor is present. This study explores different machine learning (K-Nearest Neighbors, Random Forest and Support Vector Machines) and deep learning (Long Short-Term Memory neural networks) models in order to provide a binary (Tremor; No Tremor) classification of kinematic (angle displacement) and electromyography (EMG) signals recorded from patients diagnosed with essential tremors and healthy subjects. Three types of signal sequences without any feature extraction were used as inputs for the classifiers: kinematics (wrist flexion-extension angle), raw EMG and EMG envelopes from wrist flexor and extensor muscles. All the models showed high classification scores (Tremor vs. No Tremor) for the different input data modalities, ranging from 0.8 to 0.99 for the f(1) score. The LSTM models achieved 0.98 f(1) scores for the classification of raw EMG signals, showing high potential to detect tremors without any processed features or preliminary information. These models may be explored in real-time closed-loop PES strategies to detect tremors and enable stimulation with minimal signal processing steps.
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Powering electronic implants by high frequency volume conduction: in human validation

  • Minguillon, Jesus
  • Tudela Pi, Marc
  • Becerra Fajardo, Laura
  • Perera Bel, Enric
  • Ama, Antonio J. del
  • Gil-Agudo, Ángel
  • Megía-García, Álvaro
  • García-Moreno, Aracelys
  • Ivorra Cano, Antoni, 1974-
Objective: Wireless power transfer (WPT) is used as an alternative to batteries to accomplish miniaturization in electronic medical implants. However, established WPT methods require bulky parts within the implant or cumbersome external systems, hindering minimally invasive deployments and the development of networks of implants. As an alternative, we propose a WPT approach based on volume conduction of high frequency (HF) current bursts. These currents are applied through external electrodes and are collected by the implants through two electrodes at their opposite ends. This approach avoids bulky components, enabling the development of flexible threadlike implants. Methods: We study in humans if HF (6.78 MHz) current bursts complying with safety standards and applied through two textile electrodes strapped around a limb can provide substantial powers from pairs of implanted electrodes. Results: Time averaged electric powers obtained from needle electrodes (diameter = 0.4 mm, length = 3 mm, separation = 30 mm) inserted into arms and lower legs of five healthy participants were 5.9 ± 0.7 mW and 2.4 ± 0.3 mW respectively. We also characterize the coupling between the external system and the implants using personalized two-port impedance models generated from medical images. Conclusions: The results demonstrate that innocuous and imperceptible HF current bursts that flow through the tissues by volume conduction can be used to wirelessly power threadlike implants. Significance: This is the first time that WPT based on volume conduction is demonstrated in humans. This method overcomes the limitations of existing WPT methods in terms of minimal invasiveness and usability., This work has received funding from the European Union’s Horizon 2020 research and innovation programme under Grant 779982 (Project EXTEND—Bidirectional Hyper-Connected Neural System). A. Ivorra gratefully acknowledges the financial support by ICREA under the ICREA Academia programme.
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

First-in-human demonstration of floating EMG sensors and stimulators wirelessly powered and operated by volume conduction

  • Becerra Fajardo, Laura
  • Minguillon, Jesus
  • Krob, Marc Oliver
  • Rodrigues, Camila
  • González Sánchez, Miguel
  • Megía-García, Álvaro
  • Redondo Galán, Carolina
  • Gutiérrez Henares, Francisco
  • Comerma-Montells, Albert
  • Del-Alma, Antonio J.
  • Gil-Agudo, Ángel
  • Grandas, Francisco
  • Schneider-Ickert, Andreas
  • Barroso, Filipe O.
  • Ivorra Cano, Antoni, 1974-
Background: Recently we reported the design and evaluation of floating semi-implantable devices that receive power from and bidirectionally communicate with an external system using coupling by volume conduction. The approach, of which the semi-implantable devices are proof-of-concept prototypes, may overcome some limitations presented by existing neuroprostheses, especially those related to implant size and deployment, as the implants avoid bulky components and can be developed as threadlike devices. Here, it is reported the first-in-human acute demonstration of these devices for electromyography (EMG) sensing and electrical stimulation. Methods: A proof-of-concept device, consisting of implantable thin-film electrodes and a nonimplantable miniature electronic circuit connected to them, was deployed in the upper or lower limb of six healthy participants. Two external electrodes were strapped around the limb and were connected to the external system which delivered high frequency current bursts. Within these bursts, 13 commands were modulated to communicate with the implant. Results: Four devices were deployed in the biceps brachii and the gastrocnemius medialis muscles, and the external system was able to power and communicate with them. Limitations regarding insertion and communication speed are reported. Sensing and stimulation parameters were configured from the external system. In one participant, electrical stimulation and EMG acquisition assays were performed, demonstrating the feasibility of the approach to power and communicate with the floating device. Conclusions: This is the first-in-human demonstration of EMG sensors and electrical stimulators powered and operated by volume conduction. These proof-of-concept devices can be miniaturized using current microelectronic technologies, enabling fully implantable networked neuroprosthetics., This work has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No. 779982 (Project EXTEND - Bidirectional Hyper-Connected Neural System). CR has been also partially funded by CSIC Interdisciplinary Thematic Platform (PTI+) NEURO-AGINGl+ (PTI-NEURO-AGING+). FOB thanks the financial support from the Spanish MCIN/AEI/https://doi.org/10.13039/501100011033 and by the “European Union NextGenerationEU/PRTR” under Grant agreement IJC2020-044467-I. AI gratefully acknowledges the financial support by ICREA under the ICREA Academia programme.
Repositorio Digital de la UPF
Publicación Contribución de congreso (ConferenceOutput)

In vitro evaluation of a protocol and an architecture for bidirectional communications in networks of wireless implants powered by volume conduction

  • Becerra Fajardo, Laura
  • Minguillon, Jesus
  • Rodrigues, Camila
  • Barroso, Filipe O.
  • Pons, José L.
  • Ivorra Cano, Antoni, 1974-
Comunicació presentada a: International Conference on NeuroRehabilitation (ICNR) celebrat del 13 al 16 d'octubre de 2020 de manera virtual., Wireless active implantable medical devices (AIMDs) can be an alternative for overcoming the drawbacks faced with superficial and percutaneous technologies. However, current AIMDs require bulky and rigid components for powering, hampering their miniaturization. AIMDs based on power transfer by volume conduction do not need these voluminous parts, allowing the development of thread-like devices that could be used for distributed stimulation and sensing of the neuromuscular system. In this paper, we present an in vitro evaluation of a protocol and an architecture for bidirectional communications in networks of injectable wireless implants powered and controlled by volume conduction. The wireless prototypes were successfully addressed from the external systems, and end-to-end bidirectional communication was performed at 256 kbps with a success rate of 87%., This work was funded by the European Union’s Horizon 2020 Research and Innovation Programme (Project EXTEND—Bidirectional HyperConnected Neural System) under grant agreement No 779982. Antoni Ivorra gratefully acknowledges the financial support by ICREA under the ICREA Academia programme.
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Floating EMG sensors and stimulators wirelessly powered and operated by volume conduction for networked neuroprosthetics

  • Becerra Fajardo, Laura
  • Krob, Marc Oliver
  • Minguillon, Jesus
  • Rodrigues, Camila
  • Welsch, Christine
  • Tudela Pi, Marc
  • Comerma-Montells, Albert
  • Oliveira Barroso, Filipe
  • Schneider, Andreas
  • Ivorra Cano, Antoni, 1974-
Background: Implantable neuroprostheses consisting of a central electronic unit wired to electrodes benefit thousands of patients worldwide. However, they present limitations that restrict their use. Those limitations, which are more adverse in motor neuroprostheses, mostly arise from their bulkiness and the need to perform complex surgical implantation procedures. Alternatively, it has been proposed the development of distributed networks of intramuscular wireless microsensors and microstimulators that communicate with external systems for analyzing neuromuscular activity and performing stimulation or controlling external devices. This paradigm requires the development of miniaturized implants that can be wirelessly powered and operated by an external system. To accomplish this, we propose a wireless power transfer (WPT) and communications approach based on volume conduction of innocuous high frequency (HF) current bursts. The currents are applied through external textile electrodes and are collected by the wireless devices through two electrodes for powering and bidirectional digital communications. As these devices do not require bulky components for obtaining power, they may have a flexible threadlike conformation, facilitating deep implantation by injection. Methods: We report the design and evaluation of advanced prototypes based on the above approach. The system consists of an external unit, floating semi-implantable devices for sensing and stimulation, and a bidirectional communications protocol. The devices are intended for their future use in acute human trials to demonstrate the distributed paradigm. The technology is assayed in vitro using an agar phantom, and in vivo in hindlimbs of anesthetized rabbits. Results: The semi-implantable devices were able to power and bidirectionally communicate with the external unit. Using 13 commands modulated in innocuous 3 MHz HF current bursts, the external unit configured the sensing and stimulation parameters, and controlled their execution. Raw EMG was successfully acquired by the wireless devices at 1 ksps. Conclusions: The demonstrated approach overcomes key limitations of existing neuroprostheses, paving the way to the development of distributed flexible threadlike sensors and stimulators. To the best of our knowledge, these devices are the first based on WPT by volume conduction that can work as EMG sensors and as electrical stimulators in a network of wireless devices., This work has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No. 779982 (Project EXTEND—Bidirectional Hyper-Connected Neural System), and from the European Research Council (ERC)—European Union’s Horizon 2020 research and innovation programme under Grant agreement No. 724244 (eAXON). CR has been also partially funded by CSIC Interdisciplinary Thematic Platform (PTI+) NEURO-AGINGl+ (PTI-NEURO-AGING+). AI gratefully acknowledges the financial support by ICREA under the ICREA Academia programme.
Repositorio Digital de la UPF
Publicación Contribución de congreso (ConferenceOutput)

Networks of injectable microdevices powered and digitally linked by volume conduction for neuroprosthetics: a proof-of-concept

  • Becerra Fajardo, Laura
  • Minguillon, Jesus
  • Comerma-Montells, Albert
  • Ivorra Cano, Antoni, 1974-
Comunicació presentada a 11th International IEEE/EMBS Conference on Neural Engineering (NER 2023), celebrada del 24 al 27 d'abril de 2023 a Baltimore, Estats Units., Wireless power transfer (WPT) methods such as inductive coupling and ultrasounds are used as an alternative to electrochemical batteries to energize active implantable medical devices. However, existing WPT methods require the use of bulky components (e.g., coils) that hinder miniaturization. To avoid this, we proposed the use of volume conduction of high frequency (HF) current bursts to power and bidirectionally communicate with threadlike implants that can be used for electrical stimulation and sensing (e.g., electromyography acquisition). Here, we in vitro demonstrate that several wireless devices can be powered and digitally linked by volume conduction. Eleven devices were randomly placed in a saline medium and were enclosed by two electrodes connected to an external system. The system interrogated the devices, and the waveforms obtained by the external system's demodulator were digitally processed to decode the information sent by the devices through the same HF current bursts. Data was successfully decoded from the devices, independently of the power that each single device obtained. The WPT efficiency of volume conduction boosts when a massive number of devices are powered with a single external system, creating a network of microdevices for neuroprosthetics. This will allow to accomplish closed-loop control for neural interphases using highly miniaturized injectable devices., This work has received funding from the European Research Council (ERC) - European Union’s Horizon 2020 research and innovation programme under grant agreement No. 724244 (eAXON) and from the European Union’s Horizon 2020 research and innovation programme under grant agreement No. 779982 (Project EXTEND - Bidirectional Hyper-Connected Neural System). AI gratefully acknowledges the financial support by ICREA under the ICREA Academia programme.
Digibug. Repositorio Institucional de la Universidad de Granada
Publicación Artículo científico (JournalArticle)

Inteligencia Artificial para el bien común (AI4SG): IA y los objetivos de desarrollo sostenible, Artificial Intelligence for social good (AI4SG): AI and sustainable development goals

  • Monasterio Astobiza, Aníbal
Este trabajo se ha realizado, en parte, gracias al apoyo de los siguientes proyectos de investigación: EXTEND (H2020 Research Project, ref. 779982), INBOTS (H2020, Research Project, ref. 780073) y EthAI+3 (PID2019-104943RB-100)., Frente a una narrativa distópica presente en los medios de comunicación y cultura popular que caracteriza el avance y desarrollo de la inteligencia artificial como una amenaza o riesgo existencial (e.g. desempleo tecnológico, sistemas de armas autónomas letales, robots asesinos, propaganda política computacional etc.) quiero valorar de manera crítica y constructiva el rol de la inteligencia artificial para el bien común (AI4SG). La tecnología digital también se puede aplicar para la solución de grandes problemas de la humanidad, como los 17 Objetivos de Desarrollo Sostenible y sus 169 metas de la agenda 2030. En este artículo, comentaré distintos casos de uso y aplicación de la inteligencia artificial y la robótica encaminados a conseguir los 17 Objetivos de Desarrollo Sostenible y qué principios éticos deben guiar su aplicación para que la inteligencia artificial consiga la ambiciosa agenda 2030. También comentaré el plan de acción de España y la estrategia nacional para cumplir la agenda 2030 y de qué manera incorpora las TIC., Contrary to a dystopian narrative present in the mass media and popular culture that characterizes the advancement and development of Artificial Intelligence as an existential threat or risk (e.g. technological unemployment, lethal autonomous weapons systems, killer robots, computer- based political propaganda, etc.), I want to critically and constructively evaluate the role of Artificial Intelligence for social good (AI4SG). Digital technology can also be applied to solving humanity’s big problems, such as the 17 Sustainable Development Goals and their 169 targets for the 2030 agenda. In this article, I will comment on different cases of use and application of Artificial Intelligence and robotics aimed at achieving the 17 Sustainable Development Goals and what ethical principles must guide their application so that AI achieves the ambitious 2030 agenda. I will also comment on Spain’s action plan and national strategy to fulfil the 2030 agenda and how it incorporates ICT., H2020 Research Project, ref. 779982, H2020, Research Project, ref. 780073, PID2019-104943RB-100
Digibug. Repositorio Institucional de la Universidad de Granada
Publicación Artículo científico (JournalArticle)

Valoraciones éticas para una inteligencia artificial adecuada a la privacidad, Ethical assessments for a privacy-friendly artificial intelligence

  • Morte Ferrer, Ricardo
Este artículo ha sido elaborado en el marco de sendas colaboraciones con los proyectos INBOTS (European Union’s Horizon 2020 research and innovation programme under grant agreement No. 780073) y EXTEND (European Union’s Horizon 2020 research and innovation programme under grant agreement No. 779982)., Desde hace ya bastante tiempo existe una tendencia a afirmar que el derecho o las normas de diferente tipo no son adecuadas o aplicables para las diferentes nuevas tecnologías que van apareciendo de forma continua (computación en la nube, big data, Internet de las cosas, robots, inteligencia artificial...). Este trabajo intentará dar la vuelta a ese razonamiento y, centrándose en la inteligencia artificial, tratará de plantear criterios adecuados para que esa tecnología y muchas otras sean desarrolladas y aplicadas de forma adecuada a los derechos fundamentales en general y a la privacidad en particular. Dentro de esos criterios se analizará lo que debe aportar la explicabilidad de la tecnología mencionada (requisito introducido por diferentes grupos de expertos) y se profundizará en algunos conceptos adicionales como la posibilidad y la necesidad de controlar (hasta el punto de poder detener en cualquier momento un sistema de inteligencia artificial) y de auditar sistemas de inteligencia artificial. Para realizar la mencionada profundización se recurrirá a lo que se conoce como objetivos de protección (disponibilidad, confidencialidad, integridad, transparencia, no encadenabilidad y capacidad de intervenir) y a los principios de la ciberética, incluyendo una referencia especial a la sostenibilidad y a la resiliencia de este tipo de sistemas., For quite some time now, there has been a tendency to claim that the law or different types of standards are not adequate or applicable to the different new technologies that are continuously appearing (cloud computing, big data, the Internet of Things, robots, Artificial Intelligence, etc.). This paper will attempt to turn this reasoning on its head and, focusing on Artificial Intelligence, propose suitable criteria for this technology and many others to be developed and applied appropriately to fundamental rights, in general, and privacy in particular. Within these criteria, an analysis will be made of what the explainability of the aforementioned technology should provide (a requirement introduced by different groups of experts) and some additional concepts, such as the possibility/necessity of controlling (to the point of being able to stop an Artificial Intelligence system at any time) and auditing Artificial Intelligence systems, will be explored in greater depth. In order to carry out the aforementioned in-depth study, we will use what are known as protection goals (availability, confidentiality, integrity, transparency, unlinkability, and ability to intervene) and the principles of Cyberethics, including a special reference to the sustainability and resilience of these types of systems., European Union’s Horizon 2020 research and innovation programme under grant agreement No. 780073, European Union’s Horizon 2020 research and innovation programme under grant agreement No. 779982
Digibug. Repositorio Institucional de la Universidad de Granada
Publicación Artículo científico (JournalArticle)

Floating EMG sensors and stimulators wirelessly powered and operated by volume conduction for networked neuroprosthetics

  • Becerra Fajardo, Laura
  • Minguillón Campos, Jesús|||0000-0003-4682-6898
Background: Implantable neuroprostheses consisting of a central electronic unit wired to electrodes benefit thousands of patients worldwide. However, they present limitations that restrict their use. Those limitations, which are more adverse in motor neuroprostheses, mostly arise from their bulkiness and the need to perform complex surgical implantation procedures. Alternatively, it has been proposed the development of distributed networks of intramuscular wireless microsensors and microstimulators that communicate with external systems for analyzing neuromuscular activity and performing stimulation or controlling external devices. This paradigm requires the development of miniaturized implants that can be wirelessly powered and operated by an external system. To accomplish this, we propose a wireless power transfer (WPT) and communications approach based on volume conduction of innocuous high frequency (HF) current bursts. The currents are applied through external textile electrodes and are collected by the wireless devices through two electrodes for powering and bidirectional digital communications. As these devices do not require bulky components for obtaining power, they may have a flexible threadlike conformation, facilitating deep implantation by injection. Methods: We report the design and evaluation of advanced prototypes based on the above approach. The system consists of an external unit, floating semi-implantable devices for sensing and stimulation, and a bidirectional communications protocol. The devices are intended for their future use in acute human trials to demonstrate the distributed paradigm. The technology is assayed in vitro using an agar phantom, and in vivo in hindlimbs of anesthetized rabbits. Results: The semi-implantable devices were able to power and bidirectionally communicate with the external unit. Using 13 commands modulated in innocuous 3 MHz HF current bursts, the external unit configured the sensing and stimulation parameters, and controlled their execution. Raw EMG was successfully acquired by the wireless devices at 1 ksps. Conclusions: The demonstrated approach overcomes key limitations of existing neuroprostheses, paving the way to the development of distributed flexible threadlike sensors and stimulators. To the best of our knowledge, these devices are the first based on WPT by volume conduction that can work as EMG sensors and as electrical stimulators in a network of wireless devices., European Commission 779982, European Research Council (ERC) 724244, CSIC Interdisciplinary Thematic Platform (PTI+) NEURO-AGINGl+ (PTI-NEURO-AGING+), ICREA
Digibug. Repositorio Institucional de la Universidad de Granada
Publicación Artículo científico (JournalArticle)

Attitudes about Brain–Computer Interface (BCI) technology among Spanish rehabilitation professionals

  • Monasterio Astobiza, Aníbal
  • Rodríguez Arias Vailhen, David
Funding for open access charge: Universidad de Granada/CBUA. Intelligent Neuro-Technologies Restoring Functions of Action and Communication: An Evaluation Study (Interfaces) AC15/00085 (FEDER), EXTEND (H2020 Research Project, ref. 779982) and EthAI + 3 (PID2019-104943RB-100)., To assess—from a qualitative perspective—the perceptions and attitudes of Spanish rehabilitation professionals (e.g. rehabilitation doctors, speech therapists, physical therapists) about Brain–Computer Interface (BCI) technology. A qualitative, exploratory and descriptive study was carried out by means of interviews and analysis of textual content with mixed generation of categories and segmentation into frequency of topics. We present the results of three in-depth interviews that were conducted with Spanish speaking individuals who had previously completed a survey as part of a larger, 3-country/language, survey on BCI perceptions. 11 out of 15 of these Spanish respondents (survey) either strongly or somewhat accept the use of BCI in rehabilitation therapy. However, the results of our three in-depth interviews show how, due to a strong inertia of attitudes and perceptions about BCI technology, most professionals feel reluctant to use BCI technology in their daily practice (interview)., Universidad de Granada/CBUA AC15/00085 779982 PID2019-104943RB-100
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Entornos de funcionamientos robotizados. ¿Es posible una robótica inclusiva?, Robotized Functionings Environments. Is it Possible an Inclusive Robotics?

  • Toboso-Martín, Mario
  • Aparicio Payá, Manuel
[EN] The conceptual materials that serve as a basis for our reflec-tions in this contribution are, on the one hand, a “discursive” approach to the relationship between users and technologies, in which we take into consideration the respective sets of values, representations and social practices that make up the discourse of the users and the artefactual discourse materialized in technological devices. On the other hand, the capability approach of Sen and Nussbaum, as a widely accepted and in-fluential ethical-political paradigm. With such materials, we will try to define the profiles to which a robotics of interaction with human beings that can be defined as an inclusive robotics, in relation to people with dis-abilities and children, should fit. The responsible introduction of inclusive robotics, as a mediating factor in functionings environments, requires that the general obligations of protection, full rights and well-being un-derlying the discourse and normative framework of the Convention on the Rights of Persons with Disabilities, and the Convention on the Rights of the Child, be taken as a reference in order to ensure careful protection towards the vulnerability of these groups of people., [ES] Los materiales conceptuales que sirven de base a nuestras re-flexiones en este trabajo son, por un lado, un enfoque “discursivo” de la relación entre usuarios y tecnologías, en el que tomamos en considera-ción los respectivos conjuntos de valores, representaciones y prácticas sociales que configuran cada discurso, el de los usuarios y el discurso ar-tefactual materializado en los dispositivos tecnológicos. Por otro lado, el enfoque de capacidades de Sen y Nussbaum, en cuanto paradigma ético-político de amplia aceptación e influencia. Con tales materiales, trataremos de definir los perfiles de una robótica interactiva que pueda definirse como robótica inclusiva, en relación a las personas con discapaci-dad, personas mayores y niños. Su introducción responsable como factor de mediación en los entornos de funcionamientos requiere adoptar las obligaciones normativo-axiológicas subyacentes en la Convención sobre los Derechos de las Personas con Discapacidad, y en la Convención sobre los Derechos del Niño, con el fin de garantizar la protección cuidadosa frente a la vulnerabilidad propia de estos grupos sociales., Este trabajo se enmarca en los proyectos europeos INBOTS (780073) y EXTEND (779982), del Programa H2020, y en el proyecto Capacitismo (FFI2017-88787-R) del Programa Retos del Plan Estatal Español de I+D+i, del Ministerio de Economía, Industria y Competitividad., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Un marco ético-político para la robótica asistencial, An Ethical-Political Framework for Assistive Robotics

  • Aparicio Payá, Manuel
  • Toboso-Martín, Mario
  • Ausín, Txetxu
  • Monasterio Astobiza, Aníbal
  • Morte Ferrer, Ricardo
  • López Castro, Daniel
[EN] In this paper we consider the ethical-political basis of a new conception of human vulnerability in the Convention on the Rights of Persons with Disabilities (CRPD), proposing its incorporation in the development of emerging robotic technology. We reflect on the notion of assistance. The CRPD suggests a new conception based on the social recognition of personal autonomy through a set of human rights, grounded on the value of respect for the diversity of human functionings. The capability approach (Martha Nussbaum) provides important theoretical support for this new conception. From this new perspective of justice, focused on inclusive human development, we argue that the role of healthcare robotics should be reoriented towards an inclusive robotics: one that, in addition to contributing to care, enables support for what people can do in different life stages, facilitating their inclusion in diverse social environments (education, work environment, etc.)., [ES] En este trabajo consideramos las bases ético-políticas de una nueva concepción acerca de la vulnerabilidad humana recogida en la Convención sobre los Derechos de las Personas con discapacidad (CDPD), proponiendo su incorporación en los desarrollos de la tecnología emergente robótica. Reflexionamos sobre la noción de asistencia. En la CDPD se apunta una nueva concepción basada en el reconocimiento social de la autonomía personal mediante un conjunto de derechos humanos, sustentados en el valor de respeto a la diversidad de funcionamientos humanos. El enfoque de las capacidades (Martha Nussbaum) proporciona un importante apoyo teórico a esta nueva concepción. Desde esta nueva óptica de justicia, centrada en un desarrollo humano inclusivo, argumentamos que el papel de la robótica asistencial debe ser reorientado hacia una robótica inclusiva: aquella que, además de contribuir al cuidado, posibilita el apoyo a lo que las personas, en sus diferentes etapas vitales, son capaces de hacer, facilitando su inclusión en diversos entornos sociales (educación, entorno laboral, etc.), Este trabajo se enmarca en los proyectos europeos INBOTS (780073) y EXTEND (779982), del Programa H2020, y en el proyecto Capacitismo (FFI2017-88787-R) del Programa Retos del Plan Estatal Español de I+D+i, del Ministerio de Economía, Industria y Competitividad., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Traducir el pensamiento en acción: Interfaces cerebro-máquina y el problema ético de la agencia

  • Monasterio Astobiza, Aníbal
  • Ausín, Txetxu
  • Toboso-Martín, Mario
  • Morte, Ricardo
  • Aparicio Payá, Manuel
  • López Castro, Daniel
[EN] The aim of this article is twofold: Firstly, we intend to describe the classical theory of intentional agency and to analyze how the neuro-technology of brain-machine interfaces (BCI) challenges the demands of that classical theory of agency and body consciousness. BCI neuro-technology works by implanting electrodes directly into the motor brain cortex that controls movement and detect neuronal signals associated with the intention to move, what is decoded by an algorithm on a computer in real time. Thus, someone could simply think about moving a leg or an arm and the tool (a prosthesis or exoskeleton) would receive the information to translate thought into action. This is yet feasible and its applications could involve rehabilitation of motor function and the possibility of enhancing human abilities. Both applications give rise to various several ethical implications but mainly to one that we call “the ethical problem of agency”. Secondly, we briefly explore the ethics of algorithms in the context of BCI neuro-technology and the way autonomy, responsibility, and informational privacy are understood. Finally, we advocate the need for an ethical framework of principles governing neuro-technology, such as the new neuro-rights., [ES] En este artículo, nos proponemos dos objetivos: el primero, describir la teoría clásica de la agencia intencional y cómo la neurotecnología de las interfaces cerebro-máquina desafía los requisitos de la teoría clásica de la agencia y de la consciencia corporal. La neurotecnología de las interfaces cerebro-máquina funciona implantando electrodos directamente en el área de la corteza motora del cerebro que controla el movimiento, y está diseñada para detectar las señales neuronales asociadas con la intención de moverse, que son después decodificadas por un algoritmo en un computador en tiempo real. Así, una persona podría pensar en mover su pierna o su brazo y la máquina recibiría la información de su pensamiento para traducir el pensamiento en acción, mediante prótesis internas o exoesqueletos. Esto es posible y sus aplicaciones se proyectan tanto sobre la rehabilitación de la funcionalidad motora, como sobre la posibilidad de mejoramiento (enhancement) de las capacidades humanas. Ambas aplicaciones dan lugar a numerosas implicaciones éticas, pero destacamos principalmente una, que denominamos: el problema ético de la agencia. El segundo objetivo del artículo es explorar brevemente la ética algorítmica en el contexto de las interfaces cerebro-máquina y cómo se entienden en este ámbito la autonomía, la responsabilidad y la privacidad informacional. Finalmente, abogamos por la necesidad de un marco ético de principios que regule la neurotecnología, y en tal sentido apelamos a los nuevos neuroderechos, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Otros (Other)

Robotics as an Instrument for Social Mediation

  • Toboso-Martín, Mario
  • Morte, Ricardo
  • Monasterio Astobiza, Aníbal
  • Ausín, Txetxu
  • Aparicio Payá, Manuel
  • López Castro, Daniel
The relationship of a community with a robotic device happens by means of a social discourse comprised of social values, practices and representations of this device. But the robot that connects with the user community also brings with it values, practices and representations coming from the communities responsible for its idea, design, development and manufacturing, marketing, commercialization and distribution. This artefactual discourse, brought to life in the device, is present in the environments where it is used and might come to modify the discourse in the community. As devices that mediate actions, robots not only transforms the practices carried out in an environment, but also its characteristic values., This paper benefits from Grant Agreements 780073-INBOTS and 779982-EXTEND., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Otros (Other)

Discursive Frameworks for the Development of Inclusive Robotics

  • Aparicio Payá, Manuel
  • Toboso-Martín, Mario
  • Ausín, Txetxu
  • López Castro, Daniel
  • Morte, Ricardo
  • Monasterio Astobiza, Aníbal
Important ethical-political ideas are analysed in this contribution: autonomy, dependency, vulnerability, functioning, care and disability, within the relevant discursive frameworks for development of an inclusive robotics. This development will have to take into account the regulatory framework of the UN Convention on the Rights of Persons with Disabilities, and prospectively orient itself towards facilitating autonomy in the achievement of human functionings in inclusive environments, guaranteeing the conditions for good care. To this end, it will be important to also pay attention to theoretical frameworks such as the capability approach (Sen, Nussbaum) and ethical conceptions of care (Tronto, Kittay). Additionally, we feel another social group that should be considered regarding the consequences coming from the introduction of robotics is the group made up of children and adolescents. For the responsible integration of inclusive and interactive robotics, as a mediating factor in the socialisation process, it is necessary to maintain careful protections in regard to the inherent vulnerability of this group; this requires that the general regulatory obligations regarding protection, full development and wellbeing underlying the discourse in the Convention on the Rights of the Child be used as a reference in order to always safeguard the greater interests of the minor., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Otros (Other)

Cartography of the Values Involved in Robotics

  • López Castro, Daniel
  • Monasterio Astobiza, Aníbal
  • Toboso-Martín, Mario
  • Aparicio Payá, Manuel
  • Ausín, Txetxu
  • Morte, Ricardo
In this contribution, we analyse important questions related to the conceptual foundations of axiology, or the discipline concerned with the study of value, with regard to its repercussion in the field of inclusive robotics. We take a pluralistic position on the subject, with the goal of presenting a way for us to approach the complex system of values around which current scientific-technological practice takes place. Based on these considerations, we provide a set of ideas that can be useful as a bridge to move from the axiology of the technology towards the field of inclusive robotics within the paradigm of Responsible Research and Innovation (RRI)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Otros (Other)

Conceptual Analysis: Technology, Machine and Robot

  • Monasterio Astobiza, Aníbal
  • López Castro, Daniel
  • Aparicio Payá, Manuel
  • Morte, Ricardo
  • Ausín, Txetxu
  • Toboso-Martín, Mario
In contrast to the hegemonic conceptual analysis from philosophy, we explore an alternative psychology based on perception and people’s use of the words robot, machine and technology. To do this, we use computing tools to analyse information from Wikipedia and Google’s search engine, which lets us envisage a digital paradigm in the understanding of robotics., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

A thin-film multichannel electrode for muscle recording and stimulation in neuroprosthetics applications

  • Muceli, S.
  • Poppendieck, W.
  • Hoffmann, K.P.
  • Dosen, S.
  • Benito-León, Julián
  • Barroso, Filipe O.
  • Pons Rovira, José Luis
  • Farina, Dario
Objective. We propose, design and test a novel thin-film multichannel electrode that can be used for both recording from and stimulating a muscle in acute implants. Approach. The system is built on a substrate of polyimide and contains 12 recording and three stimulation sites made of platinum. The structure is 420 μm wide, 20 μm thick and embeds the recording and stimulation contacts on the two sides of the polyimide over an approximate length of 2 cm. We show representative applications in healthy individuals as well as tremor patients. The designed system was tested by a psychometric characterization of the stimulation contacts in six tremor patients and three healthy individuals determining the perception threshold and current limit as well as the success rate in discriminating elicited sensations (electrotactile feedback). Also, we investigated the possibility of using the intramuscular electrode for reducing tremor in one patient by electrical stimulation delivered with timing based on the electromyographic activity recorded with the same electrode. Main results. In the tremor patients, the current corresponding to the perception threshold and the current limit were 0.7 ± 0.2 and 1.4 ± 0.7 mA for the wrist flexor muscles and 0.4 ± 0.2 and 1.5 ± 0.7 mA for the extensors. In one patient, closed-loop stimulation resulted in a decrease of the tremor power >50%. In healthy individuals the perception threshold and current limits were 0.9 ± 0.6 and 2.1 ± 0.6 mA for the extensor carpi radialis muscle. The subjects could distinguish four or six stimulation patterns (two or three stimulation sites × two stimulation current amplitudes) with true positive rate >80% (two subjects) and >60% (one subject), respectively. Significance. The proposed electrode provides a compact multichannel interface for recording electromyogram and delivering electrical stimulation in applications such as neuroprostheses for tremor suppression and closed-loop myoelectric prostheses., This study was financed by the European Projects EXTEND (H2020-ICT-23-2017-779982) and NeuroTREMOR (FP7-ICT-2011-7-287739). The funding agency was not involved in the collection, analyses, and interpretation of data or writing and publication of this article.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Otros (Other)

Personal autonomy in elderly and disabled: How assistive technologies impact on it

  • Morte Ferrer, Ricardo
  • Toboso-Martín, Mario
  • Aparicio Payá, Manuel
  • Ausín, Txetxu
  • Monasterio Astobiza, Aníbal
  • López Castro, Daniel
Technological change has been notable in recent decades, including the field of assistive technologies aimed at promoting the autonomy of the elderly and disabled people. Personal autonomy is possible thanks to ethical-juridical protection through reciprocally recognized human rights (civil and political, economic, social and cultural, third generation). The current technological change could produce an alteration in the exercise of personal autonomy, putting at risk its normative protection, since some of these rights currently require technological mediations to be able to be carried out. Nowadays, the UN Convention on the Rights of Persons with Disabilities (CRPD) governs as the international normative framework that defines and protects the autonomy of people with disabilities, mostly elderly, and includes important references to technological developments. New assistive technologies, that can be used to record physiological variables or to monitor habitual patterns of life, are suggested as devices that promote personal autonomy. Health monitoring could impact privacy, identity, integrity, and the protection of personal data. Therefore, it is necessary to broaden the ethical reflection from the CRPD to the relevant regulations on privacy and data protection (General Data Protection Regulation [GDPR] and Draft Privacy Regulation ePrivacy) and the Data Protection Impact Assessment (DPIA) provided in Art. 35 GDPR, which is especially relevant for the realm of assistive technologies. In this contribution we show how technological change affects some aspects of personal autonomy, its normative protection, privacy, and care., This contribution benefits from the participation of the authors in the following research projects: EU H2020 Programme projects “Inclusive Robotics for a Better Society” (INBOTS, ref. 780073) and “Bidirectional Hyper-connected Neural Systems” (EXTEND, ref. 779982). Retos Programme of the Spanish State R + D + i Plan MINECO, “Capacitismo” project (ref. FFI2017-88787-R). Aníbal Monasterio has been assisted by the Basque Government., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Otros (Other)

Lower Limb Exoskeletons in Latin-America: Proceedings of the 4th International Symposium on Wearable Robotics, WeRob2018, October 16-20, 2018, Pisa, Italy

  • Ama, Antonio J. del
  • Azorín, J.
  • Pons Rovira, José Luis
  • Frizera Neto, Anselmo
  • Rodrigues, Thomaz
  • Gil-Agudo, Ángel
  • Roa, Javier O.
  • Moreno, Javier
This article surveys the main lower limb exoskeletons developed, or under development, in Latin-America, under the REASISTE Ibero American Network. There are several groups working in this field, which approaches and results are comparable to those reported by other groups in Europe or North America (ALLOR, CPWalker, BioMot, Kinesis and CHIEF exoskeletons), the overall activity in this field is comparatively limited. Moreover, we have noticed a lack of clinical experimentation, which further prevents the advancement of the filed in Latin-America. The specific conditions of the healthcare systems, as well as the differences among cultures may yield valuable information towards the rethinking of the design of the exoskeletons., This work is supported by H2020 R&I EXTEND project (Ref. 779982), REASISTE of CYTEDprogramm (Ref. 216RT0504) and Fondo de Investigaciones Sanitarias del Instituto Carlos III(Ref. PI15/01437).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Otros (Other)

Noninvasive Modalities Used in Spinal Cord Injury Rehabilitation

  • Barroso, Filipe O.
  • Pascual-Valdunciel, Alejandro
  • Torricelli, Diego
  • Moreno, Juan Camilo
  • Ama, Antonio J. del
  • Laczko, Jozsef
  • Pons Rovira, José Luis
In the past three decades, research on plasticity after spinal cord injury (SCI) has led to a gradual shift in SCI rehabilitation: the former focus on learning compensatory strategies changed to functional neurorecovery, that is, promoting restoration of function through the use of affected limbs. This paradigm shift contributed to the development of technology-based interventions aiming to promote neurorecovery through repetitive training. This chapter presents an overview of a range of noninvasive modalities that have been used in rehabilitation after SCI. Among others, we present repetitive transcranial magnetic stimulation (rTMS), transcranial direct current stimulation (tDCS), surface electrical stimulation tools such as transcutaneous electrical spinal cord stimulation (tcSCS), transcutaneous electrical nerve stimulation (TENS), and functional electrical stimulation (FES), as well as its integration with cycling training and assistive robotic devices. The most recent results attained and the potential relevance of these new techniques to strengthen the efficacy of the residual neuronal pathways and improve spasticity are also presented. Future efforts toward the widespread clinical application of these modalities include more advances in the technology, together with the knowledge obtained from basic research and clinical trials. This can ultimately lead to novel customized interventions that meet specific needs of SCI patients., This work was funded by the European Union’s Horizon 2020 research and innovation programme (Project EXTEND—Bidirectional Hyper-Connected Neural System) under grant agreement No 779982 and by the EFOP-3.6.1-16-2016-00004 grant.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Otros (Other)

The Public Dimension of Care: Towards a Public Ethics of Care

  • Ausín, Txetxu
As essentially social beings, we humans are fragile and dependent on what is outside ourselves—others, institutions and sustained and sustainable environments—. Vulnerability acquires for us a social role (not a mere contingency or a subjective disposition) and hence the positive social obligations arise to minimize instability and its differential distribution, to demand basic support (food, shelter, work, healthcare, education, mobility, expression) and to reduce avoidable damage. We are a social species, with reciprocal links (rights and duties), built on the interdependence; not a group of solitary individuals whose mutual obligations are limited to not invading other people’s space. Care-related obligations by the (social) state come into play here, as in the case of healthcare systems. These can be characterized as “due cares” (due actions) because the action is an expected event within a social context of values and guidelines. In that context, the omission that causes or enables harm, as in exclusion from healthcare, qualifies as an “undue inaction”. In the criminal legal sense, the idea of “nonfeasance” refers to bringing about a result by not avoiding it, by violating a special duty, which equates with its causation—the prototypical example is the crime of failing to assist. Here the question not only of intentional omission but of neglect and abandonment comes into play. One example is the exclusion from healthcare and drugs of wide sectors of the Spanish population, not only undocumented migrants but also poor and unemployed people. The State is shamelessly neglecting important segments of the population, and causing harm—especially to the most vulnerable—by an ethically reprehensible omission of care. This case illustrates the need for defining what we have called “a public ethics of care” combining public ethics obligations with the responsibilities of care—since the ethics of care shapes government., This work has been sponsored by the Spanish Ministry of Economy and Competitiveness through its research project KONTUZ! (FFI2014-53926-R): www.kontuz.weebly.com; INBOTS (EU-H2020 grant agreement 780073); and EXTEND (EU-H2020 grant agreement 779982)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Peripheral electrical stimulation to reduce pathological tremor: a review

  • Pascual-Valdunciel, Alejandro
  • Hoo, G.W.
  • Avrillon, S.
  • Barroso, Filipe O.
  • Goldman, J.G.
  • Hernandez-Pavon, J.C.
  • Pons Rovira, José Luis
Interventions to reduce tremor in essential tremor (ET) and Parkinson’s disease (PD) clinical populations often utilize pharmacological or surgical therapies. However, there can be significant side effects, decline in effectiveness over time, or clinical contraindications for these interventions. Therefore, alternative approaches must be considered and developed. Some non-pharmacological strategies include assistive devices, orthoses and mechanical loading of the tremorgenic limb, while others propose peripheral electrical stimulation. Specifically, peripheral electrical stimulation encompasses strategies that activate motor and sensory pathways to evoke muscle contractions and impact sensorimotor function. Numerous studies report the efficacy of peripheral electrical stimulation to alter tremor generation, thereby opening new perspectives for both short- and long-term tremor reduction. Therefore, it is timely to explore this promising modality in a comprehensive review. In this review, we analyzed 27 studies that reported the use of peripheral electrical stimulation to reduce tremor and discuss various considerations regarding peripheral electrical stimulation: the stimulation strategies and parameters, electrodes, experimental designs, results, and mechanisms hypothesized to reduce tremor. From our review, we identified a high degree of disparity across studies with regard to stimulation patterns, experimental designs and methods of assessing tremor. Having standardized experimental methodology is a critical step in the field and is needed in order to accurately compare results across studies. With this review, we explore peripheral electrical stimulation as an intervention for tremor reduction, identify the limitations and benefits of the current state-of-the-art studies, and provide ideas to guide the development of novel approaches based on the neural circuitries and mechanical properties implied in tremor generation., This work was funded by the European Union’s Horizon 2020 research and innovation program (Project EXTEND—Bidirectional Hyper‑Connected Neural System) under grant agreement No 779982). This work was also funded by the Shirley Ryan AbilityLab.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

¿Por qué ética para la Inteligencia Artificial? Lo viejo, lo nuevo y lo espurio

  • Ausín, Txetxu
[EN] Our reality, our life, is already configured as a socio-technical system in which we interact with people, devices, data, algorithms, robots. Artificial intelligence, data science and robotics are disruptive technologies that are reconfiguring life. And we already know that technological artifacts incorporate values and have politics. That is why an ethical analysis of these technologies is essential, identifying the hazards we want to avoid and introducing from the very design the values we wish to promote. Not as an end in itself, but to generate citizen trust in the technologies and in the institutions that promote them, to foster their social acceptance and appropriation. Ethics constitutes a powerful tool for the technological empowerment of citizens, preventing algorithmic injustices (discrimination, profiling, biases) and promoting a necessary new “techno-social” contract., [ES] Nuestra realidad y nuestra vida se configuran ya como un sistema sociotécnico en el que interactuamos personas, dispositivos, datos, algoritmos, robots. La inteligencia artificial, la ciencia de datos y la robótica constituyen tecnologías disruptivas que están reconfigurando la vida. Y ya sabemos que los artefactos tecnológicos incorporan valores y tienen política. Por ello se hace indispensable un análisis ético de dichas tecnologías, identificando los peligros que queremos evitar e introduciendo desde el diseño mismo los valores que queremos promover. No como un fin en sí mismo, sino para generar confianza ciudadana en las tecnologías y en las instituciones que las impulsan, para favorecer su aceptación y apropiación social. La ética constituye una poderosa herramienta para el empoderamiento tecnológico de la ciudadanía, previniendo las injusticias algorítmicas (discriminación, perfilamiento, sesgos) e impulsando un necesario nuevo contrato “tecno-social”., Este trabajo se ha realizado en el marco de los proyectos INBOTS CSA network: Inclusive Robotics for a better Society (EU H2020 G.A. 780073), EXTEND: Bidirectional Hyper-Connected Neural System (EU H2020 G.A. 779982) y BIODAT: Datos de salud: Claves ético-jurídicas para la transformación digital en el ámbito sanitario (Fundación Séneca-Agencia de Ciencia y Tecnología de la Región de Murcia – Ref. 20939/PI/18)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Vivir con robots. Reflexiones éticas, jurídicas, sociales y culturales

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Otros (Other)

Robot-Human Gaze Behaviour: The Role of Eye Contact and Eye-Gaze Patterns in Human-Robot Interaction (HRI)

  • Monasterio Astobiza, Aníbal
  • Toboso-Martín, Mario
We want to explore the idea that for our naturally evolved social cognition to be applied to artificial agents (e.g. social robots) a particular configuration of the physical characteristics of the robot (e.g. physical embodiment) is needed. For example, key social features or a topography of elements similar to a human face where the eyes are essential., The authors greatefully acknowledge the support of Cost-Action 780073-INBOTS, 779982-EXTEND, EthAI+3 (PID2019-104943RB-100), Capacitismo (FFI2017-88787-R), Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Otros (Other)

Technological Change and Regulatory Protection of the Autonomy of People with Disabilities

  • Toboso-Martín, Mario
  • Aparicio, Manuel
  • Morte, Ricardo
  • Monasterio Astobiza, Aníbal
  • Ausín, Txetxu
  • López Castro, Daniel
In recent years, technological change has been very significant, including the field of assistive technologies for disability, aimed at promoting the autonomy of people with disabilities. This technological change (in which we mainly consider interactive robotics devices incorporating artificial intelligence tools) may bring with it an equally notable change in the exercise of personal autonomy, putting at risk the regulatory protection that underpins it. We refer to the repercussions that emerging technologies may have on privacy, data integrity and data protection. In this paper we will address these issues, taking as a reference the normative framework of the UN Convention on the Rights of Persons with Disabilities., This contribution is presented within the projects INBOTS (Ref. 780073) and EXTEND (Ref. 779982) of the H2020 Programme, EthAI+3 (PID2019-104943RB-100), and the project "Capacitismo" (FFI2017-88787-R) of the Retos Programme of the Spanish State R+D+I Plan., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Otros (Other)

Interactive Robotics and Children’s Human Rights

  • Aparicio, Manuel
  • Toboso-Martín, Mario
  • Morte, Ricardo
  • Monasterio Astobiza, Aníbal
  • Ausín, Txetxu
  • López Castro, Daniel
Developments in AI and robotics in recent years have opened new possibilities for the introduction of these technological devices in areas such as care, education, and entertainment, with important implications for children. The rise of interactive robotics in these fields requires that technological designs involve the impact that such interaction may have on children, considering the special needs for the protection of dignity and the growth of autonomy that characterises this stage of life. In this paper we argue that this valuing perspective on childhood introduces the requirement that robotic designs and their uses must normatively conform to the human rights of children., This contribution is presented within the projects INBOTS (Ref. 780073) and EXTEND (Ref. 779982) of the H2020 Programme, EthAI+3 (PID2019-104943RB-100), and the project “Capacitismo” (FFI2017-88787-R) of the Retos Programme of the Spanish State R+D+I Plan., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Effects of gravity and kinematic constraints on muscle synergies in arm cycling

  • Botzheim, L.
  • Laczko, Jozsef
  • Torricelli, Diego
  • Mravcsik, M.
  • Pons Rovira, José Luis
  • Barroso, Filipe O.
Arm cycling is a bimanual motor task used in medical rehabilitation and in sports training. Understanding how muscle coordination changes across different biomechanical constraints in arm cycling is a step toward improved rehabilitation approaches. This exploratory study aims to get new insights on motor control during arm cycling. To achieve our main goal, we used the muscle synergies analysis to test three hypotheses: 1) body position with respect to gravity (sitting and supine) has an effect on muscle synergies; 2) the movement size (crank length) has an effect on the synergistic behavior; 3) the bimanual cranking mode (asynchronous and synchronous) requires different synergistic control. Thirteen able-bodied volunteers performed arm cranking on a custom-made device with unconnected cranks, which allowed testing three different conditions: body position (sitting vs. supine), crank length (10cm vs. 15cm), and cranking mode (synchronous vs. asynchronous). For each of the eight possible combinations, subjects cycled for 30s while electromyography of eight muscles (four from each arm) were recorded: biceps brachii, triceps brachii, anterior deltoid, and posterior deltoid. Muscle synergies in this eight-dimensional muscle space were extracted by nonnegative matrix factorization. Four synergies accounted for over 90% of muscle activation variances in all conditions. Results showed that synergies were affected by body position and cranking mode but practically unaffected by movement size. These results suggest that the central nervous system may employ different motor control strategies in response to external constraints such as cranking mode and body position during arm cycling. NEW & NOTEWORTHY Recent studies analyzed muscle synergies in lower limb cycling. Here, we examine upper limb cycling and specifically the effect of body position with respect to gravity, movement size, and cranking mode on muscle coordination during arm cranking tasks. We show that altered body position and cranking mode affects modular organization of muscle activities. To our knowledge, this is the first study assessing motor control through muscle synergies framework during upper limb cycling with different constraints., This work was funded by the National Research, Development andInnovation Office, Hungary, under Grant GINOP 2.3.2-15-2016-00022 and the 2020-4.1.1-TKP2020 program of the University of Pecs and the European Union’s Horizon 2020 research and innovation program (Project EXTEND—Bidirectional Hyper-Connected Neural System) under Grant 779982
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Novel strategies based on sensory electrical stimulation to manage tremor in Parkinson's disease. A pilot study

  • Montero-Pardo, Cristina
  • González Sánchez, M.
  • Pascual-Valdunciel, Alejandro
  • Sánchez Pérez, J.
  • Camilo Moreno, Juan
  • Barroso, Filipe O.
  • Grandas, Francisco
  • Pons Rovira, José Luis
Objective: Tremor can be a disabling motor symptom in patients with Parkinson¿s disease (PD) and in some patients is refractory to medication. Here we present a pilot study on the potential of peripheral electrical stimulation to reduce pathological tremor in two PD patients. Background: Recently, electrical stimulation of afferent pathways has been explored as a potential approach for tremor reduction [1] [2]. We have recently demonstrated the potential of selective and adaptive timely stimulation (SATS) in essential tremor patients, with some of these patients sustaining tremor reduction 24h after stimulation trials [3]. Method: Two PD patients with rest and postural tremor (one female and one male, 50 and 59 years old) were recruited from Gregorio Marañón Hospital (Madrid, Spain). All procedures were approved by the hospital ethics committee. Surface electromyography (sEMG) electrodes were placed over flexor carpi radialis and extensor carpi radialis of the side most affected by tremor. Surface stimulation electrodes were placed over the radial and the median nerves. An embedded control unit including an electrical stimulator and an EMG amplifier was used to record sEMG signals at 2 kHz and provide biphasic stimulation of 100 Hz and 400 µs of pulse width. Four inertial measurement units were placed in the chest, lateral side of the arm, forearm, and dorsal side of the hand to quantify changes in tremor amplitude. Each patient was asked to maintain the arms in a position that would elicit the greatest tremor amplitude. Several SATS out-of-phase (i.e., stimulation of the antagonist muscle to the one presenting tremor) trials were performed on each patient (30 seconds of stimulation; 7 and 6 trials for patients 1 and 2, respectively). Clinical evaluation was performed before and immediately after the stimulation. Results: Both patients experienced a significant tremor reduction in all joints after stimulation trials (see [figure1] and [figure2]). For patient 1, the reduction was greater in the shoulder joint. Patient 2 showed considerable tremor reduction in all joints. Moreover, both patients improved in the clinical assessment. Conclusion: These preliminary results suggest that SATS via peripheral electrical stimulation may induce an acute reduction of the postural component of PD tremor. This work was supported by the EU Horizon 2020 research and innovation programme (Project EXTEND, Grant 779982)., This work was supported by the EU Horizon 2020 research and innovation programme (Project EXTEND, Grant 779982).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Ethical Governance of AI in the Global South: A Human Rights Approach to Responsible Use of AI

  • Monasterio Astobiza, Aníbal
  • Ausín, Txetxu
  • Liedo Fernández, Belén
  • Toboso-Martín, Mario
  • Aparicio, Manuel
  • López Castro, Daniel
Este artículo está sujeto a una licencia CC BY 4.0, There is a growing debate on how to regulate and make responsible use of digital technologies, particularly artificial intelligence (AI). In an increasingly globalized scenario, power relations and inequalities between different countries and regions need to be addressed. While developed countries are leading the building of an ethical governance architecture for AI, in the so-called global south (e.g., countries with a post-colonial history, also called non-developing countries), their situation of vulnerability and dependence on northern domination leads them to import digital technology, capital and modes of organization from these developed countries. This imbalance, in the absence of an ethical reflection, can have a significantly negative impact on their already excluded, oppressed and discriminated populations. In this paper, we want to explore to what extent countries from the global south that import digital technology from developed countries may be affected if we do not take into account the need for multi-level and ethical global governance of AI from a human rights/democratic perspective. In particular, we want to address two problems that may arise: (a) Lack of governance capacity in southern populations resulting from their dependence from northern leadership on technological innovations and regulations, and (b) material and workforce extractivism inflicted by the northern countries on southern ones., The authors gratefully acknowledge the support by the project EXTEND: Bidirectional Hyper- Connected Neural System” (H2020 Research Project, ref. 779982), EthAI+3 (PID2019-104943RB-100) and INEDyTO II-Bioética y Final de la Vida-PID2020-118729RB-I00. Belén Liedo thanks the Spanish Ministry of Universities grant FPU19/06027., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Attitudes about Brain–Computer Interface (BCI) technology among Spanish rehabilitation professionals

  • Monasterio Astobiza, Aníbal
  • Rodriguez Arias‑Vailhen, David
  • Ausín, Txetxu
  • Toboso-Martín, Mario
  • Aparicio, Manuel
  • López, Daniel
Este artículo está sujeto a una licencia CC BY 4.0, To assess—from a qualitative perspective—the perceptions and attitudes of Spanish rehabilitation professionals (e.g. rehabilitation doctors, speech therapists, physical therapists) about Brain–Computer Interface (BCI) technology. A qualitative, exploratory and descriptive study was carried out by means of interviews and analysis of textual content with mixed generation of categories and segmentation into frequency of topics. We present the results of three in-depth interviews that were conducted with Spanish speaking individuals who had previously completed a survey as part of a larger, 3-country/language, survey on BCI perceptions. 11 out of 15 of these Spanish respondents (survey) either strongly or somewhat accept the use of BCI in rehabilitation therapy. However, the results of our three in-depth interviews show how, due to a strong inertia of attitudes and perceptions about BCI technology, most professionals feel reluctant to use BCI technology in their daily practice (interview)., Funding for open access charge: Universidad de Granada / CBUA. Intelligent Neuro-Technologies Restoring Functions of Action and Communication: An Evaluation Study (Interfaces) AC15/00085 (FEDER), EXTEND (H2020 Research Project, ref. 779982) and EthAI + 3 (PID2019-104943RB-100), Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Classification of Kinematic and Electromyographic Signals Associated with Pathological Tremor Using Machine and Deep Learning

  • Pascual-Valdunciel, Alejandro
  • Lopo-Martínez, V.
  • Beltrán-Carrero, A.J.
  • Sendra-Arranz, R.
  • González-Sánchez, Miguel
  • Pérez-Sánchez, J.R.
  • Grandas, Francisco
  • Pons Rovira, José Luis
  • Oliveira Barroso, F.
  • Gutiérrez, Á.
Peripheral Electrical Stimulation (PES) of afferent pathways has received increased interest as a solution to reduce pathological tremors with minimal side effects. Closed-loop PES systems might present some advantages in reducing tremors, but further developments are required in order to reliably detect pathological tremors to accurately enable the stimulation only if a tremor is present. This study explores different machine learning (K-Nearest Neighbors, Random Forest and Support Vector Machines) and deep learning (Long Short-Term Memory neural networks) models in order to provide a binary (Tremor; No Tremor) classification of kinematic (angle displacement) and electromyography (EMG) signals recorded from patients diagnosed with essential tremors and healthy subjects. Three types of signal sequences without any feature extraction were used as inputs for the classifiers: kinematics (wrist flexion–extension angle), raw EMG and EMG envelopes from wrist flexor and extensor muscles. All the models showed high classification scores (Tremor vs. No Tremor) for the different input data modalities, ranging from 0.8 to 0.99 for the f score. The LSTM models achieved 0.98 f scores for the classification of raw EMG signals, showing high potential to detect tremors without any processed features or preliminary information. These models may be explored in real-time closed-loop PES strategies to detect tremors and enable stimulation with minimal signal processing steps., This study was funded by the European Union’s Horizon2020 research and innovation program (Project EXTEND—Bidirectional Hyper-Connected Neural System) under grant agreement No 779982.This work was also funded by the Spanish Ministry of Science and Innovation (Project NETremor: Development of a digital platform for the remote data management of patients with movement disorders), Project TED2021-130174B-C32, funded by MCIN/AEI/10.13039/501100011033 and the European Union Next Generation EU/PRTR. This work was also partially funded by the Spanish MCIN/AEI/10.13039/501100011033 and by the “European Union Next Generation EU/PRTR” under Grant agreement IJC2020-044467-I., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Modulation of spinal circuits following phase-dependent electrical stimulation of afferent pathways

  • Pascual-Valdunciel, Alejandro
  • Kurukuti, N.M.
  • Montero-Pardo, Cristina
  • Barroso, Filipe O.
  • Pons Rovira, José Luis
Objective. Peripheral electrical stimulation (PES) of afferent pathways is a tool commonly used to induce neural adaptations in some neural disorders such as pathological tremor or stroke. However, the neuromodulatory effects of stimulation interventions synchronized with physiological activity (closed-loop strategies) have been scarcely researched in the upper-limb. Here, the short-term spinal effects of a 20-minute stimulation protocol where afferent pathways were stimulated with a closed-loop strategy named selective and adaptive timely stimulation (SATS) were explored in 11 healthy subjects. Approach. SATS was applied to the radial nerve in-phase (INP) or out-of-phase (OOP) with respect to the muscle activity of the extensor carpi radialis (ECR). The neural adaptations at the spinal cord level were assessed for the flexor carpi radialis (FCR) by measuring disynaptic Group I inhibition, Ia presynaptic inhibition, Ib facilitation from the H-reflex and estimation of the neural drive before, immediately after, and 30 minutes after the intervention. Main results. SATS strategy delivered electrical stimulation synchronized with the real-time muscle activity measured, with an average delay of 17 ± 8 ms. SATS-INP induced increased disynaptic Group I inhibition (77 ± 23% of baseline conditioned FCR H-reflex), while SATS-OOP elicited the opposite effect (125 ± 46% of baseline conditioned FCR H-reflex). Some of the subjects maintained the changes after 30 minutes. No other significant changes were found for the rest of measurements. Significance. These results suggest that the short-term modulatory effects of phase-dependent PES occur at specific targeted spinal pathways for the wrist muscles in healthy individuals. Importantly, timely recruitment of afferent pathways synchronized with specific muscle activity is a fundamental principle that shall be considered when tailoring PES protocols to modulate specific neural circuits. (NCT number 04501133)., This study was funded by the European Union's Horizon 2020 research and innovation program (EXTEND—Bidirectional Hyper-Connected Neural System, Agreement No 779982). This work was partially funded by the Spanish MCIN/AEI/ 10.13039/501100011033 and by the European Union NextGenerationEU/PRTR, under Grant Agreement IJC2020-044467-I.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Review of electromyography onset detection methods for real-time control of robotic exoskeletons

  • Carvalho, Camila R.
  • Fernández, J.M.
  • Del-Ama, Antonio J.
  • Oliveira Barroso, F.
  • Moreno, Juan Camilo
Background: Electromyography (EMG) is a classical technique used to record electrical activity associated with muscle contraction and is widely applied in Biomechanics, Biomedical Engineering, Neuroscience and Rehabilitation Robotics. Determining muscle activation onset timing, which can be used to infer movement intention and trigger prostheses and robotic exoskeletons, is still a big challenge. The main goal of this paper was to perform a review of the state-of-the-art of EMG onset detection methods. Moreover, we compared the performance of the most commonly used methods on experimental EMG data. Methods: A total of 156 papers published until March 2022 were included in the review. The papers were analyzed in terms of application domain, pre-processing method and EMG onset detection method. The three most commonly used methods [Single (ST), Double (DT) and Adaptive Threshold (AT)] were applied offline on experimental intramuscular and surface EMG signals obtained during contractions of ankle and knee joint muscles. Results: Threshold-based methods are still the most commonly used to detect EMG onset. Compared to ST and AT, DT required more processing time and, therefore, increased onset timing detection, when applied on experimental data. The accuracy of these three methods was high (maximum error detection rate of 7.3%), demonstrating their ability to automatically detect the onset of muscle activity. Recently, other studies have tested different methods (especially Machine Learning based) to determine muscle activation onset offline, reporting promising results. Conclusions: This study organized and classified the existing EMG onset detection methods to create consensus towards a possible standardized method for EMG onset detection, which would also allow more reproducibility across studies. The three most commonly used methods (ST, DT and AT) proved to be accurate, while ST and AT were faster in terms of EMG onset detection time, especially when applied on intramuscular EMG data. These are important features towards movement intention identification, especially in real-time applications. Machine Learning methods have received increased attention as an alternative to detect muscle activation onset. However, although several methods have shown their capability offline, more research is required to address their full potential towards real-time applications, namely to infer movement intention., Open Access funding provided thanks to the CRUE‑CSIC agreement with Springer Nature. This work was funded by the European Union’s Horizon 2020 research and innovation program (Project EXTEND ‑ Biidirectional Hyper‑Connected Neural System) under grant agreement No 779982. This work has been also partially funded by CSIC Interdisciplinary Thematic Platform (PTI+) NEURO‑AGING+ (PTI‑NEURO‑AGING+) and by the Spanish Ministry of Science, Innovation and Universities, with grant agreement IJC2020‑044467‑I, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Muscle synergies analysis shows altered neural strategies in women with patellofemoral pain during walking

  • Ferreira, C.L.
  • Barroso, Filipe O.
  • Torricelli, Diego
  • Pons, José Luis
  • Politti, F.
  • Lucareli, P.R.G.
Several studies suggest that the central nervous system coordinates muscle activation by modulating neural commands directed to groups of muscles combined to form muscle synergies. Individuals with patellofemoral pain (PFP) move differently from asymptomatic individuals. Understanding the neural strategies involved in the execution of tasks such as walking can help comprehend how the movement is planned and better understand this clinical condition. The objective of this study was to compare muscle synergies between women with and without PFP during walking. Eleven women with PFP and thirteen asymptomatic women were assessed using three-dimensional kinematics and electromyography (EMG) while walking at self-selected speed. Kinematics of the trunk, pelvis and lower limbs were analyzed through the Movement Deviation Profile. Muscle synergies were extracted from the EMG signals of eight lower limb muscles collected throughout the whole gait cycle. Kinematic differences between the two groups (p<0.001, z-score = 3.06) were more evident during loading response, terminal stance, and pre-swing. PFP group presented a lower number of muscle synergies (p = 0.037), and greater variability accounted for (VAF) when using 3 (p = 0.017), 4 (p = 0.004), and 5 (p = 0.012) synergies to reconstruct all EMG signals. The PFP group also presented higher VAF for rectus femoris (p = 0.048) and gastrocnemius medialis (p = 0.019) when considering 4 synergies. Our results suggest that women with PFP show lower motor complexity and deficit in muscle coordination to execute gait, indicating that gait in PFP is the result of different neural commands compared to asymptomatic women., This work was supported by the European Union’s Horizon 2020 research and innovation programme (Project EXTEND—Bidirectional Hyper-Connected Neural System) under Grant 779982 and by the Spanish MCIN/AEI/10.13039/501100011033 and the “European Union NextGenerationEU/PRTR” under Grant agreement IJC2020-044467-I and by The National Council for Scientific and Technological Development – CNPq under Grant 310680/2022-0., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Dataset - Muscle synergies analysis shows altered neural strategies in women with patellofemoral pain during walking

  • Oliveira Barroso, F.
Several studies suggest that the central nervous system coordinates muscle activation by modulating neural commands directed to groups of muscles combined to form muscle synergies. Individuals with patellofemoral pain (PFP) move differently from asymptomatic individuals. Understanding the neural strategies involved in the execution of tasks such as walking can help comprehend how the movement is planned and better understand this clinical condition. The objective of this study was to compare muscle synergies between women with and without PFP during walking. Eleven women with PFP and thirteen asymptomatic women were assessed using three-dimensional kinematics and electromyography (EMG) while walking at self-selected speed. Kinematics of the trunk, pelvis and lower limbs were analyzed through the Movement Deviation Profile. Muscle synergies were extracted from the EMG signals of eight lower limb muscles collected throughout the whole gait cycle. Kinematic differences between the two groups (p<0.001, z-score = 3.06) were more evident during loading response, terminal stance, and pre-swing. PFP group presented a lower number of muscle synergies (p = 0.037), and greater variability accounted for (VAFtotal) when using 3 (p = 0.017), 4 (p = 0.004), and 5 (p = 0.012) synergies to reconstruct all EMG signals. The PFP group also presented higher VAFmuscle for rectus femoris (p = 0.048) and gastrocnemius medialis (p = 0.019) when considering 4 synergies. Our results suggest that women with PFP show lower motor complexity and deficit in muscle coordination to execute gait, indicating that gait in PFP is the result of different neural commands compared to asymptomatic women., This work was supported by the European Union’s Horizon 2020 research and innovation programme (Project EXTEND— Bidirectional Hyper-Connected Neural System) under Grant 779982 and by the Spanish MCIN/AEI/ 10.13039/501100011033 and the “European Union NextGenerationEU/PRTR” under Grant agreement IJC2020-044467-I and by The National Council for Scientific and Technological Development– CNPq under Grant 310680/2022-0.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

First-in-human demonstration of floating EMG sensors and stimulators wirelessly powered and operated by volume conduction

  • Becerra Fajardo, Laura
  • Minguillon, Jesus
  • Krob, Marc Oliver
  • Rodrigues, Camila
  • González Sánchez, Miguel
  • Megía-García, Álvaro
  • Redondo Galán, Carolina
  • Gutiérrez Henares, Francisco
  • Comerma-Montells, Albert
  • Del-Alma, Antonio J.
  • Gil-Agudo, Ángel
  • Grandas, Francisco
  • Schneider-Ickert, Andreas
  • Barroso, Filipe O.
  • Ivorra Cano, Antoni, 1974-
Background: Recently we reported the design and evaluation of floating semi-implantable devices that receive power from and bidirectionally communicate with an external system using coupling by volume conduction. The approach, of which the semi-implantable devices are proof-of-concept prototypes, may overcome some limitations presented by existing neuroprostheses, especially those related to implant size and deployment, as the implants avoid bulky components and can be developed as threadlike devices. Here, it is reported the first-in-human acute demonstration of these devices for electromyography (EMG) sensing and electrical stimulation. Methods: A proof-of-concept device, consisting of implantable thin-film electrodes and a nonimplantable miniature electronic circuit connected to them, was deployed in the upper or lower limb of six healthy participants. Two external electrodes were strapped around the limb and were connected to the external system which delivered high frequency current bursts. Within these bursts, 13 commands were modulated to communicate with the implant. Results: Four devices were deployed in the biceps brachii and the gastrocnemius medialis muscles, and the external system was able to power and communicate with them. Limitations regarding insertion and communication speed are reported. Sensing and stimulation parameters were configured from the external system. In one participant, electrical stimulation and EMG acquisition assays were performed, demonstrating the feasibility of the approach to power and communicate with the floating device. Conclusions: This is the first-in-human demonstration of EMG sensors and electrical stimulators powered and operated by volume conduction. These proof-of-concept devices can be miniaturized using current microelectronic technologies, enabling fully implantable networked neuroprosthetics., This work has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No. 779982 (Project EXTEND - Bidirectional Hyper-Connected Neural System). CR has been also partially funded by CSIC Interdisciplinary Thematic Platform (PTI+) NEURO-AGINGl+ (PTI-NEURO-AGING+). FOB thanks the financial support from the Spanish MCIN/AEI/https://doi.org/10.13039/501100011033 and by the “European Union NextGenerationEU/PRTR” under Grant agreement IJC2020-044467-I. AI gratefully acknowledges the financial support by ICREA under the ICREA Academia programme.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

In vitro evaluation of a protocol and an architecture for bidirectional communications in networks of wireless implants powered by volume conduction

  • Becerra Fajardo, Laura
  • Minguillon, Jesus
  • Rodrigues, Camila
  • Barroso, Filipe O.
  • Pons, José L.
  • Ivorra Cano, Antoni, 1974-
Comunicació presentada a: International Conference on NeuroRehabilitation (ICNR) celebrat del 13 al 16 d'octubre de 2020 de manera virtual., Wireless active implantable medical devices (AIMDs) can be an alternative for overcoming the drawbacks faced with superficial and percutaneous technologies. However, current AIMDs require bulky and rigid components for powering, hampering their miniaturization. AIMDs based on power transfer by volume conduction do not need these voluminous parts, allowing the development of thread-like devices that could be used for distributed stimulation and sensing of the neuromuscular system. In this paper, we present an in vitro evaluation of a protocol and an architecture for bidirectional communications in networks of injectable wireless implants powered and controlled by volume conduction. The wireless prototypes were successfully addressed from the external systems, and end-to-end bidirectional communication was performed at 256 kbps with a success rate of 87%., This work was funded by the European Union’s Horizon 2020 Research and Innovation Programme (Project EXTEND—Bidirectional HyperConnected Neural System) under grant agreement No 779982. Antoni Ivorra gratefully acknowledges the financial support by ICREA under the ICREA Academia programme.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Floating EMG sensors and stimulators wirelessly powered and operated by volume conduction for networked neuroprosthetics

  • Becerra Fajardo, Laura
  • Krob, Marc Oliver
  • Minguillon, Jesus
  • Rodrigues, Camila
  • Welsch, Christine
  • Tudela Pi, Marc
  • Comerma-Montells, Albert
  • Oliveira Barroso, Filipe
  • Schneider, Andreas
  • Ivorra Cano, Antoni, 1974-
Background: Implantable neuroprostheses consisting of a central electronic unit wired to electrodes benefit thousands of patients worldwide. However, they present limitations that restrict their use. Those limitations, which are more adverse in motor neuroprostheses, mostly arise from their bulkiness and the need to perform complex surgical implantation procedures. Alternatively, it has been proposed the development of distributed networks of intramuscular wireless microsensors and microstimulators that communicate with external systems for analyzing neuromuscular activity and performing stimulation or controlling external devices. This paradigm requires the development of miniaturized implants that can be wirelessly powered and operated by an external system. To accomplish this, we propose a wireless power transfer (WPT) and communications approach based on volume conduction of innocuous high frequency (HF) current bursts. The currents are applied through external textile electrodes and are collected by the wireless devices through two electrodes for powering and bidirectional digital communications. As these devices do not require bulky components for obtaining power, they may have a flexible threadlike conformation, facilitating deep implantation by injection. Methods: We report the design and evaluation of advanced prototypes based on the above approach. The system consists of an external unit, floating semi-implantable devices for sensing and stimulation, and a bidirectional communications protocol. The devices are intended for their future use in acute human trials to demonstrate the distributed paradigm. The technology is assayed in vitro using an agar phantom, and in vivo in hindlimbs of anesthetized rabbits. Results: The semi-implantable devices were able to power and bidirectionally communicate with the external unit. Using 13 commands modulated in innocuous 3 MHz HF current bursts, the external unit configured the sensing and stimulation parameters, and controlled their execution. Raw EMG was successfully acquired by the wireless devices at 1 ksps. Conclusions: The demonstrated approach overcomes key limitations of existing neuroprostheses, paving the way to the development of distributed flexible threadlike sensors and stimulators. To the best of our knowledge, these devices are the first based on WPT by volume conduction that can work as EMG sensors and as electrical stimulators in a network of wireless devices., This work has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No. 779982 (Project EXTEND—Bidirectional Hyper-Connected Neural System), and from the European Research Council (ERC)—European Union’s Horizon 2020 research and innovation programme under Grant agreement No. 724244 (eAXON). CR has been also partially funded by CSIC Interdisciplinary Thematic Platform (PTI+) NEURO-AGINGl+ (PTI-NEURO-AGING+). AI gratefully acknowledges the financial support by ICREA under the ICREA Academia programme.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Networks of injectable microdevices powered and digitally linked by volume conduction for neuroprosthetics: a proof-of-concept

  • Becerra Fajardo, Laura
  • Minguillon, Jesus
  • Comerma-Montells, Albert
  • Ivorra Cano, Antoni, 1974-
Comunicació presentada a 11th International IEEE/EMBS Conference on Neural Engineering (NER 2023), celebrada del 24 al 27 d'abril de 2023 a Baltimore, Estats Units., Wireless power transfer (WPT) methods such as inductive coupling and ultrasounds are used as an alternative to electrochemical batteries to energize active implantable medical devices. However, existing WPT methods require the use of bulky components (e.g., coils) that hinder miniaturization. To avoid this, we proposed the use of volume conduction of high frequency (HF) current bursts to power and bidirectionally communicate with threadlike implants that can be used for electrical stimulation and sensing (e.g., electromyography acquisition). Here, we in vitro demonstrate that several wireless devices can be powered and digitally linked by volume conduction. Eleven devices were randomly placed in a saline medium and were enclosed by two electrodes connected to an external system. The system interrogated the devices, and the waveforms obtained by the external system's demodulator were digitally processed to decode the information sent by the devices through the same HF current bursts. Data was successfully decoded from the devices, independently of the power that each single device obtained. The WPT efficiency of volume conduction boosts when a massive number of devices are powered with a single external system, creating a network of microdevices for neuroprosthetics. This will allow to accomplish closed-loop control for neural interphases using highly miniaturized injectable devices., This work has received funding from the European Research Council (ERC) - European Union’s Horizon 2020 research and innovation programme under grant agreement No. 724244 (eAXON) and from the European Union’s Horizon 2020 research and innovation programme under grant agreement No. 779982 (Project EXTEND - Bidirectional Hyper-Connected Neural System). AI gratefully acknowledges the financial support by ICREA under the ICREA Academia programme.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Powering electronic implants by high frequency volume conduction: in human validation

  • Minguillon, Jesus
  • Tudela Pi, Marc
  • Becerra Fajardo, Laura
  • Perera Bel, Enric
  • Ama, Antonio J. del
  • Gil-Agudo, Ángel
  • Megía-García, Álvaro
  • García-Moreno, Aracelys
  • Ivorra Cano, Antoni, 1974-
Objective: Wireless power transfer (WPT) is used as an alternative to batteries to accomplish miniaturization in electronic medical implants. However, established WPT methods require bulky parts within the implant or cumbersome external systems, hindering minimally invasive deployments and the development of networks of implants. As an alternative, we propose a WPT approach based on volume conduction of high frequency (HF) current bursts. These currents are applied through external electrodes and are collected by the implants through two electrodes at their opposite ends. This approach avoids bulky components, enabling the development of flexible threadlike implants. Methods: We study in humans if HF (6.78 MHz) current bursts complying with safety standards and applied through two textile electrodes strapped around a limb can provide substantial powers from pairs of implanted electrodes. Results: Time averaged electric powers obtained from needle electrodes (diameter = 0.4 mm, length = 3 mm, separation = 30 mm) inserted into arms and lower legs of five healthy participants were 5.9 ± 0.7 mW and 2.4 ± 0.3 mW respectively. We also characterize the coupling between the external system and the implants using personalized two-port impedance models generated from medical images. Conclusions: The results demonstrate that innocuous and imperceptible HF current bursts that flow through the tissues by volume conduction can be used to wirelessly power threadlike implants. Significance: This is the first time that WPT based on volume conduction is demonstrated in humans. This method overcomes the limitations of existing WPT methods in terms of minimal invasiveness and usability., This work has received funding from the European Union’s Horizon 2020 research and innovation programme under Grant 779982 (Project EXTEND—Bidirectional Hyper-Connected Neural System). A. Ivorra gratefully acknowledges the financial support by ICREA under the ICREA Academia programme.
Archivo Digital UPM
Publicación Tesis doctoral (DoctoralThesis)

Reduction of Pathological Tremor in Essential Tremor Patients Through Peripheral Electrical Stimulation of Afferent Pathways