Interleaved intramuscular stimulation with minimally overlapping electrodes evokes smooth and fatigue resistant forces

  • Eladly, Ahmed Fayed
  • Del Valle, Jaume
  • Minguillon, Jesus
  • Mercadal, Borja
  • Becerra Fajardo, Laura
  • Navarro, Xavier
  • Ivorra Cano, Antoni, 1974-
Objective. It is known that multi-site interleaved stimulation generates less muscle fatigue compared to single-site synchronous stimulation. However, in the limited number of studies in which intramuscular electrodes were used, the fatigue reduction associated with interleaved stimulation could not consistently be achieved. We hypothesize that this could be due to the inability to place the intramuscular electrodes used in interleaved stimulation in locations that minimize overlap amongst the motor units activated by the electrodes. Our objective in the present study was to use independent intramuscular electrodes to compare fatigue induced by interleaved stimulation with that generated by synchronous stimulation at the same initial force and ripple. Approach. In the medial gastrocnemius muscle of an anesthetized rabbit (n = 3), ten intramuscular hook wire electrodes were inserted at different distances from the nerve entry. Overlap was measured using the refractory technique and only three electrodes were found to be highly independent. After ensuring that forces obtained by both stimulation modalities had the same ripple and magnitude, fatigue induced during interleaved stimulation across three independent distal electrodes was compared to that obtained by synchronously delivering pulses to a single proximal electrode. Main results. Contractions evoked by interleaved stimulation exhibited less fatigue than those evoked by synchronous stimulation. Twitch force recruitment curves collected from each of the ten intramuscular electrodes showed frequent intermediate plateaus and the force value at these plateaus decreased as the distance between the electrode and nerve entry increased. Significance. The results indicate that interleaved intramuscular stimulation is preferred over synchronous intramuscular stimulation when fatigue-resistant and smooth forces are desired. In addition, the results suggest that the large muscle compartments innervated by the primary intramuscular nerve branches give rise to progressively smaller independent compartments in subsequent nerve divisions., This project has received funding from the European Research Council (ERC) under the European Union's Horizon 2020 research and innovation programme (grant agreement No. 724244). AI gratefully acknowledges the financial support by ICREA under the ICREA Academia programme. JdV and XN were supported by project GRAFIN PCI2018-093029, funded by Ministerio de Ciencia, Innovación y Universidades and European Union ERDF/ESF.
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Injectable sensors based on passive rectification of volume-conducted currents

  • Malik, Shahid
  • Castellví Fernández, Quim
  • Becerra Fajardo, Laura
  • Tudela Pi, Marc
  • García Moreno, Aracelys
  • Shojaei Baghini, Maryam
  • Ivorra Cano, Antoni, 1974-
Sensing implants that can be deployed by catheterization or by injection are preferable over implants requiring invasive surgery. However, present powering methods for active implants and present interrogation methods for passive implants require bulky parts within the implants that hinder the development of such minimally invasive devices. In this article, we propose a novel approach that potentially enables the development of passive sensing systems overcoming the limitations of previous implantable sensing systems in terms of miniaturization. In this approach implants are shaped as thread-like devices suitable for implantation by injection. Their basic structure consists of a thin elongated body with two electrodes at opposite ends and a simple and small circuit made up of a diode, a capacitor and a resistor. The interrogation method to obtain measurements from the implants consists in applying innocuous bursts of high frequency (≥1 MHz) alternating current that reach the implants by volume conduction and in capturing and processing the voltage signals that the implants produce after the bursts. As proof-of-concept, and for illustrating how to put in practice this novel approach, here we describe the development and characterization of a system for measuring the conductivity of tissues surrounding the implant. We also describe the implementation and the in vitro validation of a 0.95 mm-thick, flexible injectable implant made of off-the-shelf components. For conductivities ranging from about 0.2 to 0.8 S/m, when compared to a commercial conductivity meter, the accuracy of the implemented system was about ±10%., This project has received funding from the European Research Council (ERC) under the European Union's Horizon 2020 research and innovation programme (grant agreement No 724244). Antoni Ivorra gratefully acknowledges the financial support by ICREA under the ICREA Academia programme. Shahid Malik would like to thank the Spanish Institute for Foreign Trade (ICEX) and the Spanish National Research Council (CSIC) for the ERASMUS (Alianza 4 Universidades) mobility grant.
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Power transfer by volume conduction: in vitro validated analytical models predict DC powers above 1 mw in injectable implants

  • Tudela Pi, Marc
  • Becerra Fajardo, Laura
  • García Moreno, Aracelys
  • Minguillon, Jesus
  • Ivorra Cano, Antoni, 1974-
Galvanic coupling, or more precisely volume conduction, has been recently studied by different research groups as a method for intrabody communications. However, only in a very few occasions its use for powering implants has been proposed and proper analyses of such capability are still lacking. We present the development and the in vitro validation of a set of analytical expressions able to estimate the maximum ac and dc powers attainable in elongated implants powered by volume conduction. In particular, the expressions do not describe the complete power transfer channel but the behavior of the implants when the presence of an electric field is assumed. The expressions and the in vitro models indicate that time-averaged powers above 1 mW can be readily obtained in very thin (diameter < 1 mm) and short (length < 15 mm) implants when ac fields that comply with safety standards are present in the tissues where the implants are located. The expressions and the in vitro models also indicate that the obtained dc power is maximized by delivering the ac field in the form of short bursts rather than continuously. The study results support the use of volume conduction as a safe option to power implants., This work was supported by the European Research Council (ERC) under the European Union’s Horizon 2020 Research and Innovation Programme under Grant 724244. The work of Antoni Ivorra was supported by the ICREA under the ICREA Academia Programme.
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Frequency-induced fatigue in electrically stimulated sheep hindlimb muscles

  • Mateu Yus, Berta
  • Garcia-Maestre, Ana
  • Garcia-Moreno, Aracelys
  • Ivorra Cano, Antoni, 1974-
Functional electrical stimulation (FES) is an effective technique for restoring motor function in patients with paralysis. The early onset of muscle fatigue remains a major drawback, limiting its widespread clinical adoption. It is hypothesized that the high frequencies used in FES may be the primary factor determining muscle fatigue onset. Yet few studies have assessed the dependence of muscle fatigue on stimulation frequency. In particular, there is a need for a systematic evaluation across a continuous range of frequencies. Muscle fatigue dependence on stimulation frequency was assessed in anesthetized sheep, with the aim of modeling human musculature with physiological fidelity in the absence of potentially interfering reflexes. Following surgical muscle exposure, symmetrical 250 + 250 & micro;s biphasic pulse trains were delivered via hook wire intramuscular monopolar electrodes to either the tibialis cranialis or the extensor digitorum lateralis muscle, and isometric contraction forces were recorded. Eleven frequencies were assayed from 5 Hz to 100 Hz, with rest periods of over 10 min between trials. The extracted parameters included peak force, time to peak force, time to fatigue (defined as a 25% force drop), and the slope of force decline at fatigue. Additionally, muscle contraction ripple was assessed. Both muscles exhibited increasing fatigue with frequency, revealing three distinct frequency ranges. Fatigue rate was very slow below 15-20 Hz, gradually increased between similar to 20-50 Hz, and raised sharply above 50-75 Hz reaching fatigue in a few seconds. Remarkably, fatigue rate only started to increase substantially at 10-20 Hz. Force fusion increased with stimulation frequency, with both muscles showing fused contractions from approximately 12 Hz. The minimal fatigue observed at frequencies corresponding to natural motor unit firing rates suggests that the high frequencies used in FES are a key driver of fatigue., This project has received funding from the European Research Council (ERC) under the European Union's Horizon 2020 research and innovation programme (Grant Agreement No. 724244).
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Irreversible electroporation for the treatment of cardiac arrhythmias

  • Sugrue, Alan
  • Maor, Elad
  • Ivorra Cano, Antoni, 1974-
  • Vaidya, Vaibhav
  • Witt, Chance
  • Kapa, Suraj
  • Asirvatham, Samuel
Cardiac ablation is an established treatment modality for the management of patients with cardiac arrhythmias. Current approaches to cardiac ablation employ thermal based energy to achieve lesions (damage) within the heart. There are many shortcomings and limitations of thermal based approaches. Electroporation (DC energy) is a non-thermal alternative approach to ablation has shown significant promise in animal studies.
Repositorio Digital de la UPF
Publicación Contribución de congreso (ConferenceOutput)

Two-port networks to model galvanic coupling for intrabody communications and power transfer to implants

  • Ivorra Cano, Antoni, 1974-
  • Becerra Fajardo, Laura
  • Tudela Pi, Marc
  • Ivorra Cano, Antoni, 1974-
Comunicació presentada a: BioCAS 2018, celebrada a Cleveland, Ohio, Estats Units d'Amèrica, del 17 al 19 d'octubre de 2018., Galvanic coupling, or more precisely, volume conduction, can be used to communicate with and to transfer power to electronic implants. Since no bulky components for power, such as coils or batteries, are required within the implants, this strategy can yield very thin devices suitable for implantation by injection. To design the circuitry of both the implants and the external systems, it is desirable to possess a model that encompasses the behavior of these circuits and also the volume conduction phenomenon. Here we propose to model volume conduction with a two-port network so that the whole system can be studied in circuit simulators. The two-port network consists only of three impedances whose values can be obtained through simple measurements or through numerical methods. We report a validation of this modeling approach in a geometrically simple in vitro setup that allowed us to determine the impedances of the two-port network not only by performing measurements or through a finite element method study but also through an analytical solution., Research Council (ERC) under the European Union’s Horizon 2020 research and innovation programme (grant agreement No 724244).
Repositorio Digital de la UPF
Publicación Contribución de congreso (ConferenceOutput)

Injectable temperature sensors based on passive rectification of volume-conducted currents

  • Becerra Fajardo, Laura
  • García-Moreno, Aracelys
  • Alvarez de Eulate Llano, Nerea
  • Ivorra Cano, Antoni, 1974-
Comunicació presentada a: 2021 IEEE Biomedical Circuits and Systems Conference (BioCAS), celebrat del 6 al 9 d'octubre de 2021 virtualment, In situ monitoring of biomedical parameters with implantable sensors can provide information to trigger interventional or therapeutic actions. However, these sensors require bulky components for power or for interrogation that hinder miniaturization. We have proposed a wireless sensing method based in passive rectification of high frequency current bursts that flow through the tissues by volume conduction. Here we report the evaluation of a 0.98 mm-thick, passive, and flexible temperature sensor based on this method. The injectable microsensor obtained an accuracy of ±2.1%. This opens the possibility of continuous and in situ temperature sensing with minimal invasiveness., This project has received funding from the European Research Council (ERC) under the European Union’s Horizon 2020 research and innovation programme (grant agreements No 724244 (eAXON) and 963955 (SENSO-eAXON)), and the UPF INNOValora programme, which is co-financed by the Generalitat de Catalunya and the European Regional Development Fund. Antoni Ivorra gratefully acknowledges the financial support by ICREA under the ICREA Academia programme.
Repositorio Digital de la UPF
Publicación Contribución de congreso (ConferenceOutput)

Powering implants by Galvanic coupling: a validated analytical model predicts powers above 1 mW in injectable implants

  • Tudela Pi, Marc
  • Becerra Fajardo, Laura
  • Ivorra Cano, Antoni, 1974-
Comunicació presentada a: World Congress on Medical Physics and Biomedical Engineering 2018, celebrat del 3 al 8 de juny de 2018 a Praga, República Txeca., While galvanic coupling for intrabody communications has been proposed lately by different research groups, its use for powering active im-plantable medical devices remains almost non-existent. Here it is presented a simple analytical model able to estimate the attainable power by galvanic cou-pling based on the delivery of high frequency (> 1MHz) electric fields applied as short bursts. The results obtained with the analytical model, which is in vitro validated in the present study, indicate that time-averaged powers above 1 mW can be readily obtained in very thin (diameter < 1 mm) and short (length < 20 mm) elongated implants when fields which comply with safety standards (SAR < 10 W/kg) are present in the tissues where the implants are located. Re-markably, the model indicates that, for a given SAR, the attainable power is in-dependent of the tissue conductivity and of the duration and repetition frequen-cy of the bursts. This study reveals that galvanic coupling is a safe option to power very thin active implants, avoiding bulky components such as coils and batteries., This project has received funding from the European Research Council (ERC) under the European Union’s Horizon 2020 research and innovation programme (grant agreement No 724244).
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Wireless networks of injectable microelectronic stimulators based on rectification of volume conducted high frequency currents

  • García-Moreno, Aracelys
  • Comerma-Montells, Albert
  • Tudela Pi, Marc
  • Minguillon, Jesus
  • Becerra Fajardo, Laura
  • Ivorra Cano, Antoni, 1974-
Objective. To develop and in vivo demonstrate threadlike wireless implantable neuromuscular microstimulators that are digitally addressable. Approach. These devices perform, through its two electrodes, electronic rectification of innocuous high frequency current bursts delivered by volume conduction via epidermal textile electrodes. By avoiding the need of large components to obtain electrical energy, this approach allows the development of thin devices that can be intramuscularly implanted by minimally invasive procedures such as injection. For compliance with electrical safety standards, this approach requires a minimum distance, in the order of millimeters or a very few centimeters, between the implant electrodes. Additionally, the devices must cause minimal mechanical damage to tissues, avoid dislocation and be adequate for long-term implantation. Considering these requirements, the implants were conceived as tubular and flexible devices with two electrodes at opposite ends and, at the middle section, a hermetic metallic capsule housing the electronics. Main results. The developed implants have a submillimetric diameter (0.97 mm diameter, 35 mm length) and consist of a microcircuit, which contains a single custom-developed integrated circuit, housed within a titanium capsule (0.7 mm diameter, 6.5 mm length), and two platinum–iridium coils that form two electrodes (3 mm length) located at opposite ends of a silicone body. These neuromuscular stimulators are addressable, allowing to establish a network of microstimulators that can be controlled independently. Their operation was demonstrated in an acute study by injecting a few of them in the hind limb of anesthetized rabbits and inducing controlled and independent contractions. Significance. These results show the feasibility of manufacturing threadlike wireless addressable neuromuscular stimulators by using fabrication techniques and materials well established for chronic electronic implants. Although long-term operation still must be demonstrated, the obtained results pave the way to the clinical development of advanced motor neuroprostheses formed by dense networks of such wireless devices., This project has received funding from the European Research Council (ERC) under the European Union’s Horizon 2020 research and innovation programme (Grant Agreement No. 724244). A.I. gratefully acknowledges the financial support by ICREA under the ICREA Academia programme.
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Floating EMG sensors and stimulators wirelessly powered and operated by volume conduction for networked neuroprosthetics

  • Becerra Fajardo, Laura
  • Krob, Marc Oliver
  • Minguillon, Jesus
  • Rodrigues, Camila
  • Welsch, Christine
  • Tudela Pi, Marc
  • Comerma-Montells, Albert
  • Oliveira Barroso, Filipe
  • Schneider, Andreas
  • Ivorra Cano, Antoni, 1974-
Background: Implantable neuroprostheses consisting of a central electronic unit wired to electrodes benefit thousands of patients worldwide. However, they present limitations that restrict their use. Those limitations, which are more adverse in motor neuroprostheses, mostly arise from their bulkiness and the need to perform complex surgical implantation procedures. Alternatively, it has been proposed the development of distributed networks of intramuscular wireless microsensors and microstimulators that communicate with external systems for analyzing neuromuscular activity and performing stimulation or controlling external devices. This paradigm requires the development of miniaturized implants that can be wirelessly powered and operated by an external system. To accomplish this, we propose a wireless power transfer (WPT) and communications approach based on volume conduction of innocuous high frequency (HF) current bursts. The currents are applied through external textile electrodes and are collected by the wireless devices through two electrodes for powering and bidirectional digital communications. As these devices do not require bulky components for obtaining power, they may have a flexible threadlike conformation, facilitating deep implantation by injection. Methods: We report the design and evaluation of advanced prototypes based on the above approach. The system consists of an external unit, floating semi-implantable devices for sensing and stimulation, and a bidirectional communications protocol. The devices are intended for their future use in acute human trials to demonstrate the distributed paradigm. The technology is assayed in vitro using an agar phantom, and in vivo in hindlimbs of anesthetized rabbits. Results: The semi-implantable devices were able to power and bidirectionally communicate with the external unit. Using 13 commands modulated in innocuous 3 MHz HF current bursts, the external unit configured the sensing and stimulation parameters, and controlled their execution. Raw EMG was successfully acquired by the wireless devices at 1 ksps. Conclusions: The demonstrated approach overcomes key limitations of existing neuroprostheses, paving the way to the development of distributed flexible threadlike sensors and stimulators. To the best of our knowledge, these devices are the first based on WPT by volume conduction that can work as EMG sensors and as electrical stimulators in a network of wireless devices., This work has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No. 779982 (Project EXTEND—Bidirectional Hyper-Connected Neural System), and from the European Research Council (ERC)—European Union’s Horizon 2020 research and innovation programme under Grant agreement No. 724244 (eAXON). CR has been also partially funded by CSIC Interdisciplinary Thematic Platform (PTI+) NEURO-AGINGl+ (PTI-NEURO-AGING+). AI gratefully acknowledges the financial support by ICREA under the ICREA Academia programme.
Repositorio Digital de la UPF
Publicación Contribución de congreso (ConferenceOutput)

Networks of injectable microdevices powered and digitally linked by volume conduction for neuroprosthetics: a proof-of-concept

  • Becerra Fajardo, Laura
  • Minguillon, Jesus
  • Comerma-Montells, Albert
  • Ivorra Cano, Antoni, 1974-
Comunicació presentada a 11th International IEEE/EMBS Conference on Neural Engineering (NER 2023), celebrada del 24 al 27 d'abril de 2023 a Baltimore, Estats Units., Wireless power transfer (WPT) methods such as inductive coupling and ultrasounds are used as an alternative to electrochemical batteries to energize active implantable medical devices. However, existing WPT methods require the use of bulky components (e.g., coils) that hinder miniaturization. To avoid this, we proposed the use of volume conduction of high frequency (HF) current bursts to power and bidirectionally communicate with threadlike implants that can be used for electrical stimulation and sensing (e.g., electromyography acquisition). Here, we in vitro demonstrate that several wireless devices can be powered and digitally linked by volume conduction. Eleven devices were randomly placed in a saline medium and were enclosed by two electrodes connected to an external system. The system interrogated the devices, and the waveforms obtained by the external system's demodulator were digitally processed to decode the information sent by the devices through the same HF current bursts. Data was successfully decoded from the devices, independently of the power that each single device obtained. The WPT efficiency of volume conduction boosts when a massive number of devices are powered with a single external system, creating a network of microdevices for neuroprosthetics. This will allow to accomplish closed-loop control for neural interphases using highly miniaturized injectable devices., This work has received funding from the European Research Council (ERC) - European Union’s Horizon 2020 research and innovation programme under grant agreement No. 724244 (eAXON) and from the European Union’s Horizon 2020 research and innovation programme under grant agreement No. 779982 (Project EXTEND - Bidirectional Hyper-Connected Neural System). AI gratefully acknowledges the financial support by ICREA under the ICREA Academia programme.
Repositorio Digital de la UPF
Publicación Contribución de congreso (ConferenceOutput)

First steps towards an implantable electromyography (EMG) sensor powered and controlled by Galvanic coupling

  • Becerra Fajardo, Laura
  • Ivorra Cano, Antoni, 1974-
Comunicació presentada a: World Congress on Medical Physics and Biomedical Engineering 2018, celebrat del 3 al 8 de juny de 2018 a Praga, República Txeca., In the past it has been proposed to use implanted electromyography (EMG) sensors for myoelectric control. In contrast to surface systems, these implanted sensors provide signals with low cross-talk. To achieve this, minia-ture implantable devices that acquire and transmit real-time EMG signals are necessary. We have recently in vivo demonstrated electronic implants for elec-trical stimulation which can be safely powered and independently addressed by means of galvanic coupling. Since these implants lack bulky components as coils and batteries, we anticipate it will be possible to accomplish very thin im-plants to be massively deployed in tissues. We have also shown that these de-vices can have bidirectional communication. The aim of this work is to demon-strate a circuit architecture for embedding EMG sensing capabilities in our gal-vanically powered implants. The circuit was simulated using intramuscular EMG signals obtained from an analytical infinite volume conductor model that used a similar implant configuration. The simulations showed that the proposed analog front-end is compatible with the galvanic powering scheme and does not affect the implant’s ability to perform electrical stimulation. The system has a bandwidth of 958 Hz, an amplification gain of 45 dB, and an output-referred noise of 160 μVrms. The proposed embedded EMG sensing capabilities will boost the use of these galvanically powered implants for diagnosis, and closed-loop control., This project has received funding from the European Research Council (ERC) under the European Union’s Horizon 2020 research and innovation programme (grant agreement No 724244).
Repositorio Digital de la UPF
Publicación Artículo científico (JournalArticle)

Volume conduction for powering deeply implanted networks of wireless injectable medical devices: a numerical parametric analysis

  • Tudela Pi, Marc
  • Minguillon, Jesus
  • Becerra Fajardo, Laura
  • Ivorra Cano, Antoni, 1974-
The use of networks of wireless active implantable medical devices (AIMDs) could revolutionize the way that numerous severe illnesses are treated. However, the development of sub-mm AIMDs is hindered by the bulkiness and the transmission range that consolidated wireless power transfer (WPT) methods exhibit. The aim of this work is to numerically study and illustrate the potential of an innovative WPT technique based on volume conduction at high frequencies for powering AIMDs. In this technique, high frequency currents are coupled into the tissues through external electrodes, producing an electric field that can be partially picked-up by thin, flexible, and elongated implants. In the present study, the system formed by the external electrodes, the tissues and the implants was modeled as a two-port impedance network. The parameters of this model were obtained using a numerical solver based on the finite element method (fem). The model was used to determine the power delivered to the implants’ load (PDL) and the power transmission efficiency (PTE) of the system. The results allow the identification of the main features that influence the PDL and the PTE in a volume conduction scenario and demonstrate that volume conduction at high frequencies can be the basis for a non-focalized WPT method that can transfer powers above milliwatts to multiple mm-sized implants (<10 mm3 ) placed several centimeters (>3 cm) inside the tissues., This work was supported by the European Research Council (ERC) through the European Union’s Horizon 2020 Research and Innovation Program under Grant 724244. The work of Antoni Ivorra was supported by Institució Catalana de Recerca i Estudis Avançats (ICREA) through the ICREA Academia Program.
Digibug. Repositorio Institucional de la Universidad de Granada
Publicación Artículo científico (JournalArticle)

Floating EMG sensors and stimulators wirelessly powered and operated by volume conduction for networked neuroprosthetics

  • Becerra Fajardo, Laura
  • Minguillón Campos, Jesús|||0000-0003-4682-6898
Background: Implantable neuroprostheses consisting of a central electronic unit wired to electrodes benefit thousands of patients worldwide. However, they present limitations that restrict their use. Those limitations, which are more adverse in motor neuroprostheses, mostly arise from their bulkiness and the need to perform complex surgical implantation procedures. Alternatively, it has been proposed the development of distributed networks of intramuscular wireless microsensors and microstimulators that communicate with external systems for analyzing neuromuscular activity and performing stimulation or controlling external devices. This paradigm requires the development of miniaturized implants that can be wirelessly powered and operated by an external system. To accomplish this, we propose a wireless power transfer (WPT) and communications approach based on volume conduction of innocuous high frequency (HF) current bursts. The currents are applied through external textile electrodes and are collected by the wireless devices through two electrodes for powering and bidirectional digital communications. As these devices do not require bulky components for obtaining power, they may have a flexible threadlike conformation, facilitating deep implantation by injection. Methods: We report the design and evaluation of advanced prototypes based on the above approach. The system consists of an external unit, floating semi-implantable devices for sensing and stimulation, and a bidirectional communications protocol. The devices are intended for their future use in acute human trials to demonstrate the distributed paradigm. The technology is assayed in vitro using an agar phantom, and in vivo in hindlimbs of anesthetized rabbits. Results: The semi-implantable devices were able to power and bidirectionally communicate with the external unit. Using 13 commands modulated in innocuous 3 MHz HF current bursts, the external unit configured the sensing and stimulation parameters, and controlled their execution. Raw EMG was successfully acquired by the wireless devices at 1 ksps. Conclusions: The demonstrated approach overcomes key limitations of existing neuroprostheses, paving the way to the development of distributed flexible threadlike sensors and stimulators. To the best of our knowledge, these devices are the first based on WPT by volume conduction that can work as EMG sensors and as electrical stimulators in a network of wireless devices., European Commission 779982, European Research Council (ERC) 724244, CSIC Interdisciplinary Thematic Platform (PTI+) NEURO-AGINGl+ (PTI-NEURO-AGING+), ICREA
Digibug. Repositorio Institucional de la Universidad de Granada
Publicación Artículo científico (JournalArticle)

Wireless networks of injectable microelectronic stimulators based on rectification of volume conducted high frequency currents

  • García Moreno, Aracelys
  • Minguillón Campos, Jesús|||0000-0003-4682-6898
Objective. To develop and in vivo demonstrate threadlike wireless implantable neuromuscular microstimulators that are digitally addressable. Approach. These devices perform, through its two electrodes, electronic rectification of innocuous high frequency current bursts delivered by volume conduction via epidermal textile electrodes. By avoiding the need of large components to obtain electrical energy, this approach allows the development of thin devices that can be intramuscularly implanted by minimally invasive procedures such as injection. For compliance with electrical safety standards, this approach requires a minimum distance, in the order of millimeters or a very few centimeters, between the implant electrodes. Additionally, the devices must cause minimal mechanical damage to tissues, avoid dislocation and be adequate for long-term implantation. Considering these requirements, the implants were conceived as tubular and flexible devices with two electrodes at opposite ends and, at the middle section, a hermetic metallic capsule housing the electronics. Main results. The developed implants have a submillimetric diameter (0.97 mm diameter, 35 mm length) and consist of a microcircuit, which contains a single custom-developed integrated circuit, housed within a titanium capsule (0.7 mm diameter, 6.5 mm length), and two platinum–iridium coils that form two electrodes (3 mm length) located at opposite ends of a silicone body. These neuromuscular stimulators are addressable, allowing to establish a network of microstimulators that can be controlled independently. Their operation was demonstrated in an acute study by injecting a few of them in the hind limb of anesthetized rabbits and inducing controlled and independent contractions. Significance. These results show the feasibility of manufacturing threadlike wireless addressable neuromuscular stimulators by using fabrication techniques and materials well established for chronic electronic implants. Although long-term operation still must be demonstrated, the obtained results pave the way to the clinical development of advanced motor neuroprostheses formed by dense networks of such wireless devices., European Research Council (ERC) 724244, ICREA under the ICREA Academia programme
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Interleaved intramuscular stimulation with minimally overlapping electrodes evokes smooth and fatigue resistant forces

  • Eladly, Ahmed Fayed
  • Del Valle, Jaume
  • Minguillon, Jesus
  • Mercadal, Borja
  • Becerra Fajardo, Laura
  • Navarro, Xavier
  • Ivorra Cano, Antoni, 1974-
Objective. It is known that multi-site interleaved stimulation generates less muscle fatigue compared to single-site synchronous stimulation. However, in the limited number of studies in which intramuscular electrodes were used, the fatigue reduction associated with interleaved stimulation could not consistently be achieved. We hypothesize that this could be due to the inability to place the intramuscular electrodes used in interleaved stimulation in locations that minimize overlap amongst the motor units activated by the electrodes. Our objective in the present study was to use independent intramuscular electrodes to compare fatigue induced by interleaved stimulation with that generated by synchronous stimulation at the same initial force and ripple. Approach. In the medial gastrocnemius muscle of an anesthetized rabbit (n = 3), ten intramuscular hook wire electrodes were inserted at different distances from the nerve entry. Overlap was measured using the refractory technique and only three electrodes were found to be highly independent. After ensuring that forces obtained by both stimulation modalities had the same ripple and magnitude, fatigue induced during interleaved stimulation across three independent distal electrodes was compared to that obtained by synchronously delivering pulses to a single proximal electrode. Main results. Contractions evoked by interleaved stimulation exhibited less fatigue than those evoked by synchronous stimulation. Twitch force recruitment curves collected from each of the ten intramuscular electrodes showed frequent intermediate plateaus and the force value at these plateaus decreased as the distance between the electrode and nerve entry increased. Significance. The results indicate that interleaved intramuscular stimulation is preferred over synchronous intramuscular stimulation when fatigue-resistant and smooth forces are desired. In addition, the results suggest that the large muscle compartments innervated by the primary intramuscular nerve branches give rise to progressively smaller independent compartments in subsequent nerve divisions., This project has received funding from the European Research Council (ERC) under the European Union's Horizon 2020 research and innovation programme (grant agreement No. 724244). AI gratefully acknowledges the financial support by ICREA under the ICREA Academia programme. JdV and XN were supported by project GRAFIN PCI2018-093029, funded by Ministerio de Ciencia, Innovación y Universidades and European Union ERDF/ESF.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Two-port networks to model galvanic coupling for intrabody communications and power transfer to implants

  • Ivorra Cano, Antoni, 1974-
  • Becerra Fajardo, Laura
  • Tudela Pi, Marc
  • Ivorra Cano, Antoni, 1974-
Comunicació presentada a: BioCAS 2018, celebrada a Cleveland, Ohio, Estats Units d'Amèrica, del 17 al 19 d'octubre de 2018., Galvanic coupling, or more precisely, volume conduction, can be used to communicate with and to transfer power to electronic implants. Since no bulky components for power, such as coils or batteries, are required within the implants, this strategy can yield very thin devices suitable for implantation by injection. To design the circuitry of both the implants and the external systems, it is desirable to possess a model that encompasses the behavior of these circuits and also the volume conduction phenomenon. Here we propose to model volume conduction with a two-port network so that the whole system can be studied in circuit simulators. The two-port network consists only of three impedances whose values can be obtained through simple measurements or through numerical methods. We report a validation of this modeling approach in a geometrically simple in vitro setup that allowed us to determine the impedances of the two-port network not only by performing measurements or through a finite element method study but also through an analytical solution., Research Council (ERC) under the European Union’s Horizon 2020 research and innovation programme (grant agreement No 724244).
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Frequency-induced fatigue in electrically stimulated sheep hindlimb muscles

  • Mateu Yus, Berta
  • Garcia-Maestre, Ana
  • Garcia-Moreno, Aracelys
  • Ivorra Cano, Antoni, 1974-
Functional electrical stimulation (FES) is an effective technique for restoring motor function in patients with paralysis. The early onset of muscle fatigue remains a major drawback, limiting its widespread clinical adoption. It is hypothesized that the high frequencies used in FES may be the primary factor determining muscle fatigue onset. Yet few studies have assessed the dependence of muscle fatigue on stimulation frequency. In particular, there is a need for a systematic evaluation across a continuous range of frequencies. Muscle fatigue dependence on stimulation frequency was assessed in anesthetized sheep, with the aim of modeling human musculature with physiological fidelity in the absence of potentially interfering reflexes. Following surgical muscle exposure, symmetrical 250 + 250 & micro;s biphasic pulse trains were delivered via hook wire intramuscular monopolar electrodes to either the tibialis cranialis or the extensor digitorum lateralis muscle, and isometric contraction forces were recorded. Eleven frequencies were assayed from 5 Hz to 100 Hz, with rest periods of over 10 min between trials. The extracted parameters included peak force, time to peak force, time to fatigue (defined as a 25% force drop), and the slope of force decline at fatigue. Additionally, muscle contraction ripple was assessed. Both muscles exhibited increasing fatigue with frequency, revealing three distinct frequency ranges. Fatigue rate was very slow below 15-20 Hz, gradually increased between similar to 20-50 Hz, and raised sharply above 50-75 Hz reaching fatigue in a few seconds. Remarkably, fatigue rate only started to increase substantially at 10-20 Hz. Force fusion increased with stimulation frequency, with both muscles showing fused contractions from approximately 12 Hz. The minimal fatigue observed at frequencies corresponding to natural motor unit firing rates suggests that the high frequencies used in FES are a key driver of fatigue., This project has received funding from the European Research Council (ERC) under the European Union's Horizon 2020 research and innovation programme (Grant Agreement No. 724244).
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

First steps towards an implantable electromyography (EMG) sensor powered and controlled by Galvanic coupling

  • Becerra Fajardo, Laura
  • Ivorra Cano, Antoni, 1974-
Comunicació presentada a: World Congress on Medical Physics and Biomedical Engineering 2018, celebrat del 3 al 8 de juny de 2018 a Praga, República Txeca., In the past it has been proposed to use implanted electromyography (EMG) sensors for myoelectric control. In contrast to surface systems, these implanted sensors provide signals with low cross-talk. To achieve this, minia-ture implantable devices that acquire and transmit real-time EMG signals are necessary. We have recently in vivo demonstrated electronic implants for elec-trical stimulation which can be safely powered and independently addressed by means of galvanic coupling. Since these implants lack bulky components as coils and batteries, we anticipate it will be possible to accomplish very thin im-plants to be massively deployed in tissues. We have also shown that these de-vices can have bidirectional communication. The aim of this work is to demon-strate a circuit architecture for embedding EMG sensing capabilities in our gal-vanically powered implants. The circuit was simulated using intramuscular EMG signals obtained from an analytical infinite volume conductor model that used a similar implant configuration. The simulations showed that the proposed analog front-end is compatible with the galvanic powering scheme and does not affect the implant’s ability to perform electrical stimulation. The system has a bandwidth of 958 Hz, an amplification gain of 45 dB, and an output-referred noise of 160 μVrms. The proposed embedded EMG sensing capabilities will boost the use of these galvanically powered implants for diagnosis, and closed-loop control., This project has received funding from the European Research Council (ERC) under the European Union’s Horizon 2020 research and innovation programme (grant agreement No 724244).
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Injectable sensors based on passive rectification of volume-conducted currents

  • Malik, Shahid
  • Castellví Fernández, Quim
  • Becerra Fajardo, Laura
  • Tudela Pi, Marc
  • García Moreno, Aracelys
  • Shojaei Baghini, Maryam
  • Ivorra Cano, Antoni, 1974-
Sensing implants that can be deployed by catheterization or by injection are preferable over implants requiring invasive surgery. However, present powering methods for active implants and present interrogation methods for passive implants require bulky parts within the implants that hinder the development of such minimally invasive devices. In this article, we propose a novel approach that potentially enables the development of passive sensing systems overcoming the limitations of previous implantable sensing systems in terms of miniaturization. In this approach implants are shaped as thread-like devices suitable for implantation by injection. Their basic structure consists of a thin elongated body with two electrodes at opposite ends and a simple and small circuit made up of a diode, a capacitor and a resistor. The interrogation method to obtain measurements from the implants consists in applying innocuous bursts of high frequency (≥1 MHz) alternating current that reach the implants by volume conduction and in capturing and processing the voltage signals that the implants produce after the bursts. As proof-of-concept, and for illustrating how to put in practice this novel approach, here we describe the development and characterization of a system for measuring the conductivity of tissues surrounding the implant. We also describe the implementation and the in vitro validation of a 0.95 mm-thick, flexible injectable implant made of off-the-shelf components. For conductivities ranging from about 0.2 to 0.8 S/m, when compared to a commercial conductivity meter, the accuracy of the implemented system was about ±10%., This project has received funding from the European Research Council (ERC) under the European Union's Horizon 2020 research and innovation programme (grant agreement No 724244). Antoni Ivorra gratefully acknowledges the financial support by ICREA under the ICREA Academia programme. Shahid Malik would like to thank the Spanish Institute for Foreign Trade (ICEX) and the Spanish National Research Council (CSIC) for the ERASMUS (Alianza 4 Universidades) mobility grant.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Irreversible electroporation for the treatment of cardiac arrhythmias

  • Sugrue, Alan
  • Maor, Elad
  • Ivorra Cano, Antoni, 1974-
  • Vaidya, Vaibhav
  • Witt, Chance
  • Kapa, Suraj
  • Asirvatham, Samuel
Cardiac ablation is an established treatment modality for the management of patients with cardiac arrhythmias. Current approaches to cardiac ablation employ thermal based energy to achieve lesions (damage) within the heart. There are many shortcomings and limitations of thermal based approaches. Electroporation (DC energy) is a non-thermal alternative approach to ablation has shown significant promise in animal studies.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Floating EMG sensors and stimulators wirelessly powered and operated by volume conduction for networked neuroprosthetics

  • Becerra Fajardo, Laura
  • Krob, Marc Oliver
  • Minguillon, Jesus
  • Rodrigues, Camila
  • Welsch, Christine
  • Tudela Pi, Marc
  • Comerma-Montells, Albert
  • Oliveira Barroso, Filipe
  • Schneider, Andreas
  • Ivorra Cano, Antoni, 1974-
Background: Implantable neuroprostheses consisting of a central electronic unit wired to electrodes benefit thousands of patients worldwide. However, they present limitations that restrict their use. Those limitations, which are more adverse in motor neuroprostheses, mostly arise from their bulkiness and the need to perform complex surgical implantation procedures. Alternatively, it has been proposed the development of distributed networks of intramuscular wireless microsensors and microstimulators that communicate with external systems for analyzing neuromuscular activity and performing stimulation or controlling external devices. This paradigm requires the development of miniaturized implants that can be wirelessly powered and operated by an external system. To accomplish this, we propose a wireless power transfer (WPT) and communications approach based on volume conduction of innocuous high frequency (HF) current bursts. The currents are applied through external textile electrodes and are collected by the wireless devices through two electrodes for powering and bidirectional digital communications. As these devices do not require bulky components for obtaining power, they may have a flexible threadlike conformation, facilitating deep implantation by injection. Methods: We report the design and evaluation of advanced prototypes based on the above approach. The system consists of an external unit, floating semi-implantable devices for sensing and stimulation, and a bidirectional communications protocol. The devices are intended for their future use in acute human trials to demonstrate the distributed paradigm. The technology is assayed in vitro using an agar phantom, and in vivo in hindlimbs of anesthetized rabbits. Results: The semi-implantable devices were able to power and bidirectionally communicate with the external unit. Using 13 commands modulated in innocuous 3 MHz HF current bursts, the external unit configured the sensing and stimulation parameters, and controlled their execution. Raw EMG was successfully acquired by the wireless devices at 1 ksps. Conclusions: The demonstrated approach overcomes key limitations of existing neuroprostheses, paving the way to the development of distributed flexible threadlike sensors and stimulators. To the best of our knowledge, these devices are the first based on WPT by volume conduction that can work as EMG sensors and as electrical stimulators in a network of wireless devices., This work has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No. 779982 (Project EXTEND—Bidirectional Hyper-Connected Neural System), and from the European Research Council (ERC)—European Union’s Horizon 2020 research and innovation programme under Grant agreement No. 724244 (eAXON). CR has been also partially funded by CSIC Interdisciplinary Thematic Platform (PTI+) NEURO-AGINGl+ (PTI-NEURO-AGING+). AI gratefully acknowledges the financial support by ICREA under the ICREA Academia programme.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Powering implants by Galvanic coupling: a validated analytical model predicts powers above 1 mW in injectable implants

  • Tudela Pi, Marc
  • Becerra Fajardo, Laura
  • Ivorra Cano, Antoni, 1974-
Comunicació presentada a: World Congress on Medical Physics and Biomedical Engineering 2018, celebrat del 3 al 8 de juny de 2018 a Praga, República Txeca., While galvanic coupling for intrabody communications has been proposed lately by different research groups, its use for powering active im-plantable medical devices remains almost non-existent. Here it is presented a simple analytical model able to estimate the attainable power by galvanic cou-pling based on the delivery of high frequency (> 1MHz) electric fields applied as short bursts. The results obtained with the analytical model, which is in vitro validated in the present study, indicate that time-averaged powers above 1 mW can be readily obtained in very thin (diameter < 1 mm) and short (length < 20 mm) elongated implants when fields which comply with safety standards (SAR < 10 W/kg) are present in the tissues where the implants are located. Re-markably, the model indicates that, for a given SAR, the attainable power is in-dependent of the tissue conductivity and of the duration and repetition frequen-cy of the bursts. This study reveals that galvanic coupling is a safe option to power very thin active implants, avoiding bulky components such as coils and batteries., This project has received funding from the European Research Council (ERC) under the European Union’s Horizon 2020 research and innovation programme (grant agreement No 724244).
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Injectable temperature sensors based on passive rectification of volume-conducted currents

  • Becerra Fajardo, Laura
  • García-Moreno, Aracelys
  • Alvarez de Eulate Llano, Nerea
  • Ivorra Cano, Antoni, 1974-
Comunicació presentada a: 2021 IEEE Biomedical Circuits and Systems Conference (BioCAS), celebrat del 6 al 9 d'octubre de 2021 virtualment, In situ monitoring of biomedical parameters with implantable sensors can provide information to trigger interventional or therapeutic actions. However, these sensors require bulky components for power or for interrogation that hinder miniaturization. We have proposed a wireless sensing method based in passive rectification of high frequency current bursts that flow through the tissues by volume conduction. Here we report the evaluation of a 0.98 mm-thick, passive, and flexible temperature sensor based on this method. The injectable microsensor obtained an accuracy of ±2.1%. This opens the possibility of continuous and in situ temperature sensing with minimal invasiveness., This project has received funding from the European Research Council (ERC) under the European Union’s Horizon 2020 research and innovation programme (grant agreements No 724244 (eAXON) and 963955 (SENSO-eAXON)), and the UPF INNOValora programme, which is co-financed by the Generalitat de Catalunya and the European Regional Development Fund. Antoni Ivorra gratefully acknowledges the financial support by ICREA under the ICREA Academia programme.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Wireless networks of injectable microelectronic stimulators based on rectification of volume conducted high frequency currents

  • García-Moreno, Aracelys
  • Comerma-Montells, Albert
  • Tudela Pi, Marc
  • Minguillon, Jesus
  • Becerra Fajardo, Laura
  • Ivorra Cano, Antoni, 1974-
Objective. To develop and in vivo demonstrate threadlike wireless implantable neuromuscular microstimulators that are digitally addressable. Approach. These devices perform, through its two electrodes, electronic rectification of innocuous high frequency current bursts delivered by volume conduction via epidermal textile electrodes. By avoiding the need of large components to obtain electrical energy, this approach allows the development of thin devices that can be intramuscularly implanted by minimally invasive procedures such as injection. For compliance with electrical safety standards, this approach requires a minimum distance, in the order of millimeters or a very few centimeters, between the implant electrodes. Additionally, the devices must cause minimal mechanical damage to tissues, avoid dislocation and be adequate for long-term implantation. Considering these requirements, the implants were conceived as tubular and flexible devices with two electrodes at opposite ends and, at the middle section, a hermetic metallic capsule housing the electronics. Main results. The developed implants have a submillimetric diameter (0.97 mm diameter, 35 mm length) and consist of a microcircuit, which contains a single custom-developed integrated circuit, housed within a titanium capsule (0.7 mm diameter, 6.5 mm length), and two platinum–iridium coils that form two electrodes (3 mm length) located at opposite ends of a silicone body. These neuromuscular stimulators are addressable, allowing to establish a network of microstimulators that can be controlled independently. Their operation was demonstrated in an acute study by injecting a few of them in the hind limb of anesthetized rabbits and inducing controlled and independent contractions. Significance. These results show the feasibility of manufacturing threadlike wireless addressable neuromuscular stimulators by using fabrication techniques and materials well established for chronic electronic implants. Although long-term operation still must be demonstrated, the obtained results pave the way to the clinical development of advanced motor neuroprostheses formed by dense networks of such wireless devices., This project has received funding from the European Research Council (ERC) under the European Union’s Horizon 2020 research and innovation programme (Grant Agreement No. 724244). A.I. gratefully acknowledges the financial support by ICREA under the ICREA Academia programme.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Networks of injectable microdevices powered and digitally linked by volume conduction for neuroprosthetics: a proof-of-concept

  • Becerra Fajardo, Laura
  • Minguillon, Jesus
  • Comerma-Montells, Albert
  • Ivorra Cano, Antoni, 1974-
Comunicació presentada a 11th International IEEE/EMBS Conference on Neural Engineering (NER 2023), celebrada del 24 al 27 d'abril de 2023 a Baltimore, Estats Units., Wireless power transfer (WPT) methods such as inductive coupling and ultrasounds are used as an alternative to electrochemical batteries to energize active implantable medical devices. However, existing WPT methods require the use of bulky components (e.g., coils) that hinder miniaturization. To avoid this, we proposed the use of volume conduction of high frequency (HF) current bursts to power and bidirectionally communicate with threadlike implants that can be used for electrical stimulation and sensing (e.g., electromyography acquisition). Here, we in vitro demonstrate that several wireless devices can be powered and digitally linked by volume conduction. Eleven devices were randomly placed in a saline medium and were enclosed by two electrodes connected to an external system. The system interrogated the devices, and the waveforms obtained by the external system's demodulator were digitally processed to decode the information sent by the devices through the same HF current bursts. Data was successfully decoded from the devices, independently of the power that each single device obtained. The WPT efficiency of volume conduction boosts when a massive number of devices are powered with a single external system, creating a network of microdevices for neuroprosthetics. This will allow to accomplish closed-loop control for neural interphases using highly miniaturized injectable devices., This work has received funding from the European Research Council (ERC) - European Union’s Horizon 2020 research and innovation programme under grant agreement No. 724244 (eAXON) and from the European Union’s Horizon 2020 research and innovation programme under grant agreement No. 779982 (Project EXTEND - Bidirectional Hyper-Connected Neural System). AI gratefully acknowledges the financial support by ICREA under the ICREA Academia programme.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Volume conduction for powering deeply implanted networks of wireless injectable medical devices: a numerical parametric analysis

  • Tudela Pi, Marc
  • Minguillon, Jesus
  • Becerra Fajardo, Laura
  • Ivorra Cano, Antoni, 1974-
The use of networks of wireless active implantable medical devices (AIMDs) could revolutionize the way that numerous severe illnesses are treated. However, the development of sub-mm AIMDs is hindered by the bulkiness and the transmission range that consolidated wireless power transfer (WPT) methods exhibit. The aim of this work is to numerically study and illustrate the potential of an innovative WPT technique based on volume conduction at high frequencies for powering AIMDs. In this technique, high frequency currents are coupled into the tissues through external electrodes, producing an electric field that can be partially picked-up by thin, flexible, and elongated implants. In the present study, the system formed by the external electrodes, the tissues and the implants was modeled as a two-port impedance network. The parameters of this model were obtained using a numerical solver based on the finite element method (fem). The model was used to determine the power delivered to the implants’ load (PDL) and the power transmission efficiency (PTE) of the system. The results allow the identification of the main features that influence the PDL and the PTE in a volume conduction scenario and demonstrate that volume conduction at high frequencies can be the basis for a non-focalized WPT method that can transfer powers above milliwatts to multiple mm-sized implants (<10 mm3 ) placed several centimeters (>3 cm) inside the tissues., This work was supported by the European Research Council (ERC) through the European Union’s Horizon 2020 Research and Innovation Program under Grant 724244. The work of Antoni Ivorra was supported by Institució Catalana de Recerca i Estudis Avançats (ICREA) through the ICREA Academia Program.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Power transfer by volume conduction: in vitro validated analytical models predict DC powers above 1 mw in injectable implants

  • Tudela Pi, Marc
  • Becerra Fajardo, Laura
  • García Moreno, Aracelys
  • Minguillon, Jesus
  • Ivorra Cano, Antoni, 1974-
Galvanic coupling, or more precisely volume conduction, has been recently studied by different research groups as a method for intrabody communications. However, only in a very few occasions its use for powering implants has been proposed and proper analyses of such capability are still lacking. We present the development and the in vitro validation of a set of analytical expressions able to estimate the maximum ac and dc powers attainable in elongated implants powered by volume conduction. In particular, the expressions do not describe the complete power transfer channel but the behavior of the implants when the presence of an electric field is assumed. The expressions and the in vitro models indicate that time-averaged powers above 1 mW can be readily obtained in very thin (diameter < 1 mm) and short (length < 15 mm) implants when ac fields that comply with safety standards are present in the tissues where the implants are located. The expressions and the in vitro models also indicate that the obtained dc power is maximized by delivering the ac field in the form of short bursts rather than continuously. The study results support the use of volume conduction as a safe option to power implants., This work was supported by the European Research Council (ERC) under the European Union’s Horizon 2020 Research and Innovation Programme under Grant 724244. The work of Antoni Ivorra was supported by the ICREA under the ICREA Academia Programme.