Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

Repositorio Digital de la UPF
Publicación Contribución de congreso (ConferenceOutput)

Injectable temperature sensors based on passive rectification of volume-conducted currents

  • Becerra Fajardo, Laura
  • García-Moreno, Aracelys
  • Alvarez de Eulate Llano, Nerea
  • Ivorra Cano, Antoni, 1974-
Comunicació presentada a: 2021 IEEE Biomedical Circuits and Systems Conference (BioCAS), celebrat del 6 al 9 d'octubre de 2021 virtualment, In situ monitoring of biomedical parameters with implantable sensors can provide information to trigger interventional or therapeutic actions. However, these sensors require bulky components for power or for interrogation that hinder miniaturization. We have proposed a wireless sensing method based in passive rectification of high frequency current bursts that flow through the tissues by volume conduction. Here we report the evaluation of a 0.98 mm-thick, passive, and flexible temperature sensor based on this method. The injectable microsensor obtained an accuracy of ±2.1%. This opens the possibility of continuous and in situ temperature sensing with minimal invasiveness., This project has received funding from the European Research Council (ERC) under the European Union’s Horizon 2020 research and innovation programme (grant agreements No 724244 (eAXON) and 963955 (SENSO-eAXON)), and the UPF INNOValora programme, which is co-financed by the Generalitat de Catalunya and the European Regional Development Fund. Antoni Ivorra gratefully acknowledges the financial support by ICREA under the ICREA Academia programme.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Injectable temperature sensors based on passive rectification of volume-conducted currents

  • Becerra Fajardo, Laura
  • García-Moreno, Aracelys
  • Alvarez de Eulate Llano, Nerea
  • Ivorra Cano, Antoni, 1974-
Comunicació presentada a: 2021 IEEE Biomedical Circuits and Systems Conference (BioCAS), celebrat del 6 al 9 d'octubre de 2021 virtualment, In situ monitoring of biomedical parameters with implantable sensors can provide information to trigger interventional or therapeutic actions. However, these sensors require bulky components for power or for interrogation that hinder miniaturization. We have proposed a wireless sensing method based in passive rectification of high frequency current bursts that flow through the tissues by volume conduction. Here we report the evaluation of a 0.98 mm-thick, passive, and flexible temperature sensor based on this method. The injectable microsensor obtained an accuracy of ±2.1%. This opens the possibility of continuous and in situ temperature sensing with minimal invasiveness., This project has received funding from the European Research Council (ERC) under the European Union’s Horizon 2020 research and innovation programme (grant agreements No 724244 (eAXON) and 963955 (SENSO-eAXON)), and the UPF INNOValora programme, which is co-financed by the Generalitat de Catalunya and the European Regional Development Fund. Antoni Ivorra gratefully acknowledges the financial support by ICREA under the ICREA Academia programme.