Identification and simulation of atmospheric dispersion patterns of odour and VOCs generated by a waste treatment plant
The impact of odorous gases emitted from waste treatment plants (WTP) has been a major concern of communities
living near these facilities. This paper describes the methodology used to estimate the dispersion of
odorous and volatile organic compound (VOC) emissions from a WTP situated in Vacarisses (Barcelona). The
steps are as follows: (1) collection of gaseous samples at the WTP chimney outlet to the atmosphere; (2)
olfactometric and chemical characterization of gaseous samples; (3) identification of the main atmospheric
dispersion patterns using air mass trajectories and (4) modelling of the WTP emissions using a dispersion model.
The impact on nearby populations such as Tarrasa, Esparraguera, Martorell, Castellar del Vall´es and Manresa
(Catalonia, Spain) was evaluated.
The mean removal efficiency of the WTP biofilter was 37.0 ± 5.0%. Therefore, the remaining 63.0 ± 5.0%
accounted for emissions into the atmosphere for average odorous (1,700,000 ouE/s) and VOC emissions
(1,476,500 μg/s). VOCs were classified into 19 chemical families, of which terpenes, ketones, alcohols and
aliphatic hydrocarbons were the most abundant, with concentrations ranging from 4000 to 8000 μg/m3. The air
mass trajectory analysis identified six airflow patterns from the WTP with a clear seasonal distribution. The
simulation of the dispersion revealed that Tarrasa (to the southeast) was the most affected community, with
odorous and VOC impacts of approximately 4.0 ou/m3 and 3.5 μg/m3 (in summer, wind speed = 1.51 m/s).
Although these values are not relevant for the safety and well-being of humans, they do deteriorate air quality.