RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

A general methodology for energy comparison of intermediate configurations in two-stage vapour compression refrigeration systems

  • Torrella Alcaraz, Enrique
  • Larumbe Bernad, Juan Antonio
  • Cabello, R.
  • Llopis, R.
  • Sanchez, D.
The aim of the present paper is to describe a general methodology suitable for analysing any intermediate configuration considered in staged vapour compression refrigeration cycles. This general methodology only depends on two basic parameters related to the subcooling and desuperheating obtained in the inter-stage system. A COP expression based on the two basic parameters was obtained from the general configuration. By means of its particularization to seven common configurations, it was then possible to make an energy comparison of the various configurations working with two fluids appropriated for the low temperature domain such as ammonia and R-404A., The authors are indebted to the Spanish Ministry of Education and Science (CTM2008-06468-C02-02/TECNO) and to the Spanish Ministry of the Environment and Rural and Marine Affairs (200800050084716) for their economic support to this work.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

HCFC-22 replacement with drop-in and retrofit HFC refrigerants in a two-stage refrigeration plant for low temperature

  • Llopis, R.
  • Torrella Alcaraz, Enrique
  • Cabello, R.
  • Sanchez, D.
[EN] The world community has committed to eliminate the HCFC-22 refrigerant to a series of deadlines according to the agreements taken during the 19th Montreal Protocol meeting in September 2007. This phase-out, which is already in progress in European Countries, has been accelerated in Article 5 countries. Refrigerant manufactures offer different drop-in refrigerants to replace R22 in existing equipment by non-ozone depleting substances in order to be able to make full use of the remaining life of the plants or different retrofit refrigerants, the use of which implies modifications to the existing systems. This work aims to contribute to the understanding of the implications of the process of R22 substitution, either with drop-in or retrofitting processes, by presenting a theoretical and experimental analysis of the performance of R22, of two drop-in fluids (R422A, R417B) and a retrofit refrigerant (R404A), in a two-stage vapour compression plant over a wide range of evaporating temperatures for a fixed condensing temperature of 40 C. In this communication the main energy parameters, such as cooling capacity and COP are analysed and discussed., The authors are indebted to the Spanish Ministry of Education and Science (CTM2008-06468-CO2-02/TECNO) and to the Spanish Ministry of the Environment and Rural and Marine Affairs (200800050084716) for their economic support for the present work.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Experimental analysis of energy performance of modified single-stage CO2 transcritical vapour compression cycles based on vapour injection in the suction line

  • Cabello, Ramón
  • Sánchez, Daniel
  • Patiño, Jorge
  • Llopis, Rodrigo
  • Torrella Alcaraz, Enrique
This work presents the experimental evaluation of the energy performance of a modified single-stage CO2 transcritical refrigeration plant with an internal heat exchanger (IHX) based on vapour injection in suction line. This modification, which is only applicable to refrigeration plants with an expansion process divided in two stages with a liquid receiver between them, consists of extracting saturated vapour from the liquid receiver in order to: decrease the vapour quality at the evaporator inlet, and reduce the superheating degree at the compressor suction by means of the expansion and following injection of the extracted refrigerant. Three different injection points have been evaluated experimentally: before the IHX, after the IHX and just before the suction chamber of the compressor. The experimental measurements show that the cooling capacity and COP can be enhanced in 9.81% and 7.01%, respectively. Furthermore, a reduction in the discharge temperature of the compressor up to 14.7 C has been measured inside the evaluation range., The authors are indebted to the Spanish Ministry of Education and Science (CTM2008-06468-C02-02/TECNO) and to the Spanish Ministry of the Environment and Rural and Marine Affairs (200800050084716) for the economic support given to the present work.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Performance evaluation of R404A and R507A refrigerant mixtures in an experimental double-stage vapour compression plant

  • Llopis, R.
  • Torrella Alcaraz, Enrique
  • Cabello, R.
  • Sanchez, D.
[EN] As a result of the ban of the CFC fluids in 2000 and the future limitation of HCFC fluids, which manufacture limit is the year 2010, refrigerant producers have been working to develop different mixtures, mainly based on HFC fluids, which emulate the properties of the former refrigerants used in refrigeration plants. At the moment, the HFC-404A and the HFC-507A are the more widely used fluids in Europe as replacement of the CFC-502 in plants operating at low temperatures. This work presents the experimental evaluation, from an energy point of view, of both refrigerants in the same refrigeration plant, which corresponds to a double-stage vapour compression plant driven by a compound compressor. The characterization was made for an evaporating temperature range between ¿36 and ¿20 °C for a constant condensing temperature of 40 °C., The authors are indebted to 'Fundacion Caixa Castello-Bancaixa' (P1.1B2008-12) and to the 'Ministerio de Medioambiente y Medio Rural y Marino' (200800050084716) for the support given to the present study.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Energetic evaluation of an internal heat exchanger in a CO2 transcritical refrigeration plant using experimental data

  • Torrella Alcaraz, Enrique
  • Sanchez, D.
  • Llopis, R.
  • Cabello, R.
[EN] The performance of an Internal Heat Exchanger (IHX) operating in a CO 2 transcritical refrigeration plant is analysed, from an energetic point of view, in this work. The evaluation is based on experimental data by contrasting the performance of the plant working with (44 tests) and without the IHX (46 tests) at the same operating conditions. The experimental evaluation covers three evaporating levels (-5, -10 and -15 °C), at two different gas-cooler outlet temperatures each (31, 34 °C), for a wide range of gas-cooler operating pressures (74.5-105.9 bar). The thermal effectiveness of the IHX is empirically analysed for the different operating conditions in the first part of the paper. Moreover, the relation of its effectiveness with the operating parameters is presented. The second part is devoted to analyse the modification of the energetic performance of the plant caused by the IHX. The results show a maximum increment on cooling capacity of 12%, an increment of the efficiency of the plant up to 12% and a maximum increase on discharge temperature of 10 °C at -15 °C of evaporating temperature. © 2010 Elsevier Ltd and IIR. All rights reserved., The authors are indebted to the Spanish Ministry of Education and Science (CTM2008-06468-C02-02/TECNO) and to the Spanish Ministry of the Environment and Rural and Marine Affairs (200800050084716) for their economic support to the present work.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Development and validation of a finite element model for water - CO2 coaxial gas-coolers

  • Sanchez, D.
  • Cabello, R.
  • Llopis, R.
  • Torrella Alcaraz, Enrique
The gas-cooler heat exchanger is a characteristic device of the refrigeration plants that use CO2 as the working fluid in transcritical conditions. The proper gas-cooler sizing, allows getting the maximum effectiveness in the heat exchange, thus permitting to reduce the temperature approach and improving the heat recovered in the coolant (secondary) fluid and the COP of this kind of systems. This work deals with the development of a steady-state coaxial gas-cooler model that uses water as coolant fluid. The model is based on the finite-volume methodology and is validated with experimental data. An uncertainty lower than ±10% was obtained in the calculation of the heat transfer rates and an uncertainty lower than ±3 °C in the outlet temperatures of both fluids. Several correlations for estimating the CO2 heat convection coefficient have been studied to select the one that best fits the model. Using the model, the influence of different parameters on the gas-cooler thermal effectiveness has been analyzed and presented in this work. Finally, a comparison between the traditional ε-NTU method and the developed model has been done., The authors are indebted to the Spanish Ministry of Education and Science (CTM2008-06468-C02-02/TECNO) and to the Spanish Ministry of the Environment and Rural and Marine Affairs (200800050084716) for the economic support given to the present work.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Second law analysis of two-stage vapour compression refrigeration plants

  • Torrella Alcaraz, Enrique
  • Llopis, R.
  • Cabello, R.
  • Sanchez, D.
  • Larumbe, J.A.
[EN] This paper describes a Second Law Analysis based on experimental data of a two-stage vapour compression facility driven by a compound compressor for medium and low-capacity refrigeration applications, which operates with the most usual inter-stage configurations (direct liquid injection and subcooler). The experimental analysis is performed for an evaporating temperature range between 36 degrees C and 20 degrees C and for a condensing temperature range between 30 degrees C and 47 degrees C using the refrigerant R-404A. The final results are compared with energy analysis from previous works. Additionally, a new criterion of equivalence between the simple vapour compression cycle and the two-stage compression cycle is given., The authors are indebted to the Spanish Ministry of Education and Science (CTM2008-06468-C02-02/TECNO) and to the Spanish Ministry of the Environment and Rural and Marine Affairs (200800050084716) for their economic support to this work.