Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Insights into removal of antibiotics by selected microalgae (Chlamydomonas reinhardtii, Chlorella sorokiniana, Dunaliella tertiolecta and Pseudokirchneriella subcapitata)

  • Hom-Diaz, Andrea|||0000-0002-5465-0071
  • Jaén-Gil, Adrián|||0000-0002-3519-3717
  • Rodríguez Mozaz, Sara|||0000-0003-2962-8144
  • Barceló i Cullerés, Damià|||0000-0002-8873-0491
  • Vicent i Huguet, Teresa|||0000-0002-6547-7358
  • Blánquez, Paqui|||0000-0003-2443-9977
The increasing contamination of worldwide water with numerous antibiotics has become an emerging environmental concern due to the considerable ecotoxicity and health issues associated with some antibiotics. Microalgae-mediated remediation of pollutants is of growing scientific interest due to the ability of microalgae to take up organic/inorganic nutrients and produce biomass that can be further used for energy or biofuel generation. Elimination of pollutants from water in microalgae experiments includes various mechanisms, such as photodegradation, sorption in biomass and biodegradation. The sorption of pollutants by microalgae has been widely reported, but few studies have proven the biodegradation of pollutants by microalgae. In this work, the ability of four selected microalgae (Chlamydomonas reinhardtii, Chlorella sorokiniana, Dunaliella tertiolecta and Pseudokirchneriella subcapitata) to remove 9 antibiotics and the antidepressant venlafaxine was studied under different experimental conditions. The results show that the highest efficiency for antibiotic removal was obtained with microalgae exhibiting the highest growth rates. Promising results have been obtained from C. reinhardtii and D. tertiolecta cultures, which exhibited a rapid growth and good removal percentages for some of the antibiotics studied. Photodegradation was the main removal mechanism for the 3 fluoroquinolones studied (ciprofloxacin, ofloxacin, norfloxacin) and pipemidic acid (>78%), while for the 3 macrolides (azithromycin, clarithromycin, erythromycin), the efficiency of photodegradation was less than 5%. For the macrolides, the combination of abiotic phenomena, sorption onto the biomass and biodegradation were the mechanisms responsible for total removal. Trimethoprim and venlafaxine were shown to be very stable compounds with low removal percentages. Sulfapyridine appeared to be eliminated mainly by algae biodegradation since low sorption and photodegradation efficiencies were observed. The presence of products resulting from transformations of azithromycin, erythromycin and sulfapyridine in the liquid phase of live algae confirmed that biodegradation is one way by which microalgae eliminate these antibiotics.
DAU Arxiu Digital de la Universitat Ramon Llull
Publicación Artículo científico (JournalArticle)

Combining biological processes with UV/H2O2 for metoprolol and metoprolol acid removal in hospital wastewater

  • Jaén-Gil, Adrián
  • Buttiglieri, Gianluigi
  • Benito, Aleix
  • Mir Tutusaus, Josep Anton
  • González Olmos, Rafael
  • Caminal, Gloria
  • Barceló, Damià
  • Sarrà, Montserrat
  • Rodriguez-Mozaz, Sara
The transformation products (TPs) of water contaminants generated during wastewater treatment can sometimes be equally or even more hazardous than the parent compounds. Therefore, for a comprehensive assessment of removal efficiency of a water treatment technology, it is mandatory to monitor not only the pollutants but also of their TPs. However, this type of evaluation studies is lacking in the case of water combined treatments. In this study, the elimination of metoprolol (MTP), metoprolol acid (MTPA) and the TPs generated was evaluated in pure water and hospital wastewater (HWW) using UV/H2O2 before and after fungal (FG) or conventional activated sludge (CAS). The major transformation pathways were suggested in terms of transformation of the parent compounds through bio-transformation and photo-transformation mechanisms. The results reveal an extended removal of MTP, MTPA and TPs after UV/H2O2 single experiment treating spiked pure water at 2.5 mg/L, without increasing the treated effluents toxicity. However, combined treatments were required to achieve similar removal percentages in spiked real HWW at 2.0 μg/L: while AOPs combined with FG exhibited lower removal efficiencies with generation of persistent intermediates (such as α-HMTP and TP240), AOPs combined with CAS attained the higher persistent TPs removal. In particular, AOP + CAS was classified as the most effective combination for HWW with the highest removal of the parent compounds (86% for MTP and 100% for MTPA), of the intermediates generated (up to 85%) and with a low presence of toxic TPs (such as O-DMTP). This study demonstrates that comprehensive evaluation of the intermediates generated along water treatment technologies is highly recommended to successfully evaluate their removal efficiencies., info:eu-repo/semantics/publishedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Combining biological processes with UV/H2O2 for metoprolol and metoprolol acid removal in hospital wastewater

  • Jaén-Gil, Adrián
  • Buttiglieri, Gianluigi
  • Benito, Aleix
  • Mir Tutusaus, Josep Anton
  • González Olmos, Rafael
  • Caminal, Gloria
  • Barceló, Damià
  • Sarrà, Montserrat
  • Rodriguez-Mozaz, Sara
The transformation products (TPs) of water contaminants generated during wastewater treatment can sometimes be equally or even more hazardous than the parent compounds. Therefore, for a comprehensive assessment of removal efficiency of a water treatment technology, it is mandatory to monitor not only the pollutants but also of their TPs. However, this type of evaluation studies is lacking in the case of water combined treatments. In this study, the elimination of metoprolol (MTP), metoprolol acid (MTPA) and the TPs generated was evaluated in pure water and hospital wastewater (HWW) using UV/H2O2 before and after fungal (FG) or conventional activated sludge (CAS). The major transformation pathways were suggested in terms of transformation of the parent compounds through bio-transformation and photo-transformation mechanisms. The results reveal an extended removal of MTP, MTPA and TPs after UV/H2O2 single experiment treating spiked pure water at 2.5 mg/L, without increasing the treated effluents toxicity. However, combined treatments were required to achieve similar removal percentages in spiked real HWW at 2.0 μg/L: while AOPs combined with FG exhibited lower removal efficiencies with generation of persistent intermediates (such as α-HMTP and TP240), AOPs combined with CAS attained the higher persistent TPs removal. In particular, AOP + CAS was classified as the most effective combination for HWW with the highest removal of the parent compounds (86% for MTP and 100% for MTPA), of the intermediates generated (up to 85%) and with a low presence of toxic TPs (such as O-DMTP). This study demonstrates that comprehensive evaluation of the intermediates generated along water treatment technologies is highly recommended to successfully evaluate their removal efficiencies., info:eu-repo/semantics/publishedVersion
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Prospects on coupling UV/H2O2 with activated sludge or a fungal treatment for the removal of pharmaceutically active compounds in real hospital wastewater

  • Mir Tutusaus, Josep Anton|||0000-0002-0581-2556
  • Jaén-Gil, Adrián|||0000-0002-3519-3717
  • Barceló i Cullerés, Damià|||0000-0002-8873-0491
  • Buttiglieri, Gianluigi|||0000-0003-3419-0511
  • Gonzalez-Olmos, Rafael|||0000-0002-7515-3576
  • Rodríguez Mozaz, Sara|||0000-0003-2962-8144
  • Caminal i Saperas, Glòria|||0000-0001-9646-6099
  • Sarrà, Montserrat|||0000-0002-3447-6328
Conventional active sludge (AS) process at municipal centralized wastewater treatment facilities may exhibit little pharmaceuticals (PhACs) removal efficiencies when treating hospital wastewater (HWW). Therefore, a dedicated efficient wastewater treatment at the source point is recommended. In this sense, advanced oxidation processes (AOPs) and fungal treatment (FG) have evidenced promising results in degrading PhACs. The coupling of the AOP based on UV/HO treatment with biological treatment (AS or FG) treating a real non-sterile HWW, was evaluated in this work. In addition, a coagulation-flocculation pretreatment was applied to improve the efficiency of all approaches. Twenty-two PhACs were detected in raw HWW, which were effectively removed (93-95%) with the combination of any of the biological treatment followed by UV/HO treatment. Similar removal results (94%) were obtained when placing UV/HO treatment before FG, while a lower removal (83%) was obtained in the combination of UV/HO followed by AS. However, the latest was the only treatment combination that achieved a decrease in the toxicity of water. Moreover, deconjugation of conjugated PhACs has been suggested for ofloxacin and lorazepam after AS treatment, and for ketoprofen after fungal treatment. Monitoring of carbamazepine and its transformation products along the treatment allowed to identify the same carbamazepine degradation pathway in UV/HO and AS treatments, unlike fungal treatment, which followed another degradation route.