Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 7
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Microstrip Line loaded with Series Gap and Dumbbell Defect-Ground-Structure (DB-DGS) Resonator for Highly Sensitive Sensing Based on Resonance/Antiresonance, Application to Humidity Measurements

  • Kurniawati, Nazmia|||0000-0002-0686-8754
  • Vélez, Paris|||0000-0001-6502-5987
  • Casacuberta, Pau|||0000-0002-2658-2200
  • Su, Lijuan|||0000-0002-4753-9340
  • Canalias, Xavier|||0009-0002-6473-7514
  • Martín, Ferran|||0000-0002-1494-9167
A new planar structure for the implementation of highly sensitive single-frequency microwave sensors is proposed. The key aspect to obtaining high sensitivity is to generate closely spaced resonance and antiresonance frequencies, achieved by means of a microstrip line with a series gap etched on top of a transversely oriented dumbbell defect-ground-structure (DB-DGS) resonator, the sensitive element. By this means, both the magnitude and the phase of the transmission coefficient exhibit a high phase slope between such frequencies. The result is a high sensitivity of either the magnitude or the phase of the transmission coefficient at the operating frequency with the dielectric constant of the environment surrounding the DB-DGS resonator. Advantages of the proposed device are (i) size and simplicity and (ii) isolation between the analyte (or material under test -MUT) and the line strip. Two sensors with different DB-DGS geometry are reported to validate the proposed approach. Using the phase as the main output variable, the maximum sensitivity in one of the prototypes is found to be 88.7° per unit of dielectric constant variation. This sensor has been applied to relative humidity (RH) measurements by using a functional film of polyvinyl alcohol (PVA) deposited on top of the sensing DB-DGS resonator. The average sensitivity in this case is 0.33°/% (note that RH is given in %).
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Transmission-mode phase-variation microwave sensor applied to highly sensitive micrometer-scale thickness measurements

  • Canalias, Xavier|||0009-0002-6473-7514
  • Vélez, Paris|||0000-0001-6502-5987
  • Casacuberta, Pau|||0000-0002-2658-2200
  • Su, Lijuan|||0000-0002-4753-9340
  • Kurniawati, Nazmia|||0000-0002-0686-8754
  • Martín, Ferran|||0000-0002-1494-9167
This article proposes a highly sensitive two-port single-frequency permittivity sensor operating in transmission. The device consists of a shunt-connected short-circuited quarter-wavelength resonator (the sensing element) sandwiched between a symmetric configuration of cascaded impedance inverters with alternating high and low impedance. The output variable of the sensor is the phase of the transmission coefficient at the operating frequency, which is highly sensitive to variations in the permittivity of the medium surrounding the sensing resonator. In the proposed two-port sensor, the feeding (harmonic) signal and the output signal do not share the same port, which facilitates retrieving the output variable in scenarios where a vector network analyzer (VNA) cannot be used. The maximum sensitivity in the reported prototype is Smax= -63.94° per unit of dielectric constant variation, whereas the figure of merit (FoM), or ratio between the maximum sensitivity and the area of the sensing region expressed in squared wavelengths, is FoM.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Artificial Intelligence (AI) assisted measurement of glucose, sodium, and potassium concentrations in diluted aqueous solutions using microwaves

  • Casacuberta, Pau|||0000-0002-2658-2200
  • Vélez, Paris|||0000-0001-6502-5987
  • Martín, Ferran|||0000-0002-1494-9167
  • Paredes Marco, Ferran|||0000-0002-7252-1169
This letter proposes an artificial intelligence (AI)-driven noninvasive and contactless microwave sensor capable of determining the composition of aqueous solutions containing three different components: glucose, sodium (Na+), and potassium (K+). The sensing element is a one-port microstrip transmission line loaded with a pair of unequal three-turn complementary spiral resonators (CSRs) etched in the ground plane, as well as a capillary that drives the liquid under test (LUT) to the sensing region (i.e., the slots of the CSR). The two CSRs provide a rich frequency response (reflection coefficient), with many singularities (magnitude notches and phase jumps) over a broad frequency band that are necessary to selectively determine the concentration of the different solute components by virtue of their different dispersive behavior. The complete sensor includes the necessary mechanical accessories to implement an automated system with a liquid pump as well as temperature and fluid control. The system analyzes the renormalized S11 response to quantify the variations generated by the different components of the solution, demonstrating a high capacity of detecting their presence and reliably predicting their concentrations. A convolutional neural network (CNN) with a multilayer perceptron (MLP) maps the renormalized reflection coefficient spectra to solute concentrations. Validated on binary to quaternary mixtures, the method yields mean absolute errors of 8.2 mg/dL (glucose), 6.8 mg/dL (Na+), and 1.2 mg/dL (K+), enabling real-time quantification in complex solutions. This modular approach supports scalable dataset generation and adaptable AI training pipelines for other solutes and liquid matrices.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

A Versatile Reflective-Mode Phase-Variation Microwave Sensor Based on a Dumbbell Defect-Ground-Structure (DB-DGS) Resonator for Solid and Liquid Characterization

  • Kurniawati, Nazmia|||0000-0002-0686-8754
  • Vélez, Paris|||0000-0001-6502-5987
  • Casacuberta, Pau|||0000-0002-2658-2200
  • Su, Lijuan|||0000-0002-4753-9340
  • Canalias, Xavier|||0009-0002-6473-7514
  • Sisó, Gerard|||0000-0003-2576-6558
  • Martín, Ferran|||0000-0002-1494-9167
This article presents a single-frequency planar microwave sensor designed for characterizing solid and liquid samples. The sensor operates in reflective-mode one-port configuration utilizing a microstrip line with a series inductive strip terminated with a transversely oriented dumbbell defect-ground-structure (DB-DGS) resonator (etched in the ground plane), the sensing element. The output variable is the phase of the reflection (RX) coefficient at a specific (operating) frequency. The device is modeled by a lumped circuit consisting of a parallel resonator (accounting for the DB-DGS resonator) series connected to an inductor and a parasitic capacitor. This configuration enables the generation of a steep phase slope in the RX coefficient at the operating frequency, which is essential for achieving high sensitivity. The sensor can be applied to the detection of small variations in the permittivity of the environment surrounding the sensing element in the vicinity of a reference (REF) value, where such REF value can be selected at wish by conveniently tuning the operating frequency. To demonstrate the versatility of the proposed device, three different scenarios are considered: 1) dielectric constant of solid samples measurement; 2) ethanol concentration in deionized (DI) water determination; and 3) detection of water/detergent in wine. The maximum sensitivity achieved for the dielectric characterization of solids is -382.44° per unit of dielectric constant. For liquid sensing, the sensor exhibits sensitivities of 9°/% for ethanol concentration in water and 0.88°/% for detecting water/detergent mixtures in wine. Despite the similar electromagnetic characteristics of water/detergent and wine, the proposed sensor can resolve a volume fraction (percentage of water/detergent in wine) as little as 2.5%, demonstrating high sensitivity. For the mixture of ethanol and DI water, the sensor is capable of detecting a concentration of 1% of ethanol.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Low-Cost and Highly Sensitive Reflection Mode Phase Variation Sensor for Bacteria Detection

  • Piekarz, Ilona|||0000-0001-9862-5794
  • Sorocki, Jakub|||0000-0002-6216-7581
  • Skowroński, Witold|||0000-0002-4568-2688
  • Górska, Sabina
  • Gruszczynski, Slawomir|||0000-0002-0370-8640
  • Wincza, Krzysztof|||0000-0002-4471-7842
  • Casacuberta, Pau|||0000-0002-2658-2200
  • Vélez, Paris|||0000-0001-6502-5987
  • Martín, Ferran|||0000-0002-1494-9167
This paper presents a reflective-mode planar microwave biosensor based on phase-variation allowing for the detection of low bacteria concentration. The sensor is a one-port coplanar waveguide (CPW) structure implemented by means of a pair of weakly coupled step-impedance resonators (SIRs). The high sensitivity needed for bacteria detection is obtained by modulating (reducing) the coupling level between the pair of resonators, which simply requires separating such resonators enough. A sensor demonstrator is developed to operate in K-band, resulting in a compact structure manufactured using a single-layer metal-on-glass technology. An experimental study is conducted on an example of detection of various concentrations of E. coli bacteria, where the phase variation at single frequency is an indicator of the bacteria presence. The measurement results show that as low as 100 colony-forming-unit in 1 ml (100 CFU/ml) of bacteria suspension can be easily detected with sensitivity of 3.24° per order of concentration, indicating potential to go even lower with detection threshold, which is superior to many state-of-the-art E. coli microwave biosensors.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Planar Microwave Sensors, State of the Art and Applications

  • Juan, Carlos Gabriel|||0000-0003-0793-7958
  • Grenier, Katia|||0000-0002-5056-5582
  • Zarifi, Mohammad H.|||0000-0001-5544-3966
  • Ebrahimi, Amir|||0000-0002-1787-2230
  • Martín, Ferran|||0000-0002-1494-9167
This review paper focuses on the latest advances and applications of planar microwave sensors contributed by the most prominent researchers in the field. The paper presents the different working principles, design approaches, fabrication technologies, materials, and applications of a wide variety of planar sensors operating at microwave and millimeter-wave frequencies, including contact and contactless sensors, wired and wireless sensors, microfluidic sensors, "green" sensors, wearables, biosensors, physical sensors, chemical sensors, and more. Advanced techniques for sensor performance optimization (e.g., sensitivity, resolution, selectivity, etc.), based on artificial intelligence, active feedback loops, microwave spectroscopy, losses engineering, etc., will also be discussed in the paper.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Transmission-Mode Phase-Variation Sensor Based on Weakly Coupled Distributed Resonators and Phase Detector for High-Sensitivity Applications

  • Canalias, Xavier|||0009-0002-6473-7514
  • Vélez, Paris|||0000-0001-6502-5987
  • Casacuberta, Pau|||0000-0002-2658-2200
  • Su, Lijuan|||0000-0002-4753-9340
  • Kurniawati, Nazmia|||0000-0002-0686-8754
  • Martín, Ferran|||0000-0002-1494-9167
This letter presents a highly sensitive single-frequency permittivity sensor based on a pair of weakly coupled quarter-wavelength resonators. The sensor is a two-port structure operating in transmission, with the pair of coupled resonators shunt connected to the host line, and the output variable is the phase of the transmission coefficient at the operating frequency, i.e., the pole frequency. The maximum sensitivity of the reported prototype is Smax = -593.5° per dielectric constant, and the figure of merit, or ratio between the maximum sensitivity and the area of the sensing region expressed in terms of the squared wavelength, is FoM = 25 917°/λ2, which is a very competitive value. By operating in transmission, the main advantage of the proposed sensor over reflective-mode phase-variation sensors based on coupled resonators is the separation of the input (feeding) signal and the output (transmitted) signal at different ports. This facilitates retrieving the phase information in a real scenario, i.e., without the use of a vector network analyzer. Specifically, a phase detector for that purpose is considered in this letter. Sensor validation is carried out by detecting tiny defects (small holes) in samples and the presence of minuscule perturbations (small strips of polyethylene terephthalate) in the sensing region.