Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

Biblos-e Archivo. Repositorio Institucional de la UAM
Publicación Artículo científico (JournalArticle)

Polarization-sensitive optical projection tomography for muscle fiber imaging

  • Fang, Mengjie
  • Dong, Di
  • Zeng, Chaoting
  • Liang, Xiao
  • Yang, Xin
  • Arranz, Alicia
  • Ripoll, Jorge
  • Hui, Hui
  • Tian, Jie
Optical projection tomography (OPT) is a tool used for three-dimensional imaging of millimeter-scale biological samples, with the advantage of exhibiting isotropic resolution typically in the micron range. OPT can be divided into two types: transmission OPT (tOPT) and emission OPT (eOPT). Compared with eOPT, tOPT discriminates different tissues based on their absorption coefficient, either intrinsic or after specific staining. However, it fails to distinguish muscle fibers whose absorption coefficients are similar to surrounding tissues. To circumvent this problem, in this article we demonstrate a polarization sensitive OPT system which improves the detection and 3D imaging of muscle fibers by using polarized light. We also developed image acquisition and processing protocols that, together with the system, enable the clear visualization of muscles. Experimental results show that the muscle fibers of diaphragm and stomach, difficult to be distinguished in regular tOPT, were clearly displayed in our system, proving its potential use. Moreover, polarization sensitive OPT was fused with tOPT to investigate the stomach tissue comprehensively. Future applications of polarization sensitive OPT could be imaging other fiberlike structures such as myocardium or other tissues presenting high optical anisotropy, This work is supported by the National Basic Research Program of China (973 Program) under Grant 2011CB707700, the National Natural Science Foundation of China under Grant No. 81227901, 61231004, 81501616, 81301346, 81527805 the Chinese Academy of Sciences Fellowship for Young Foreign Scientists under Grant No. 2010Y2GA03, 2013Y1GA0004, the Chinese Academy of Sciences Visiting Professorship for Senior International Scientists under Grant No. 2012T1G0036, 2013T1G0013,the Instrument Developing Project of the Chinese Academy of Sciences under Grant No. YZ201502, YZ201457 and the Strategic Priority Research Program (B) of Chinese Academy of Sciences (XDB02060010). A. Arranz acknowledges support from the Marie Curie Intra-European Fellowship program IEF-2010-275137. J.R. acknowledges support from EC FP7 IMI project PREDICT-TB, the EC FP7 CIG grant HIGH-THROUGHPUT TOMO, and the Spanish MINECO project grant FIS2013-41802-R MESO-IMAGING
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publicación Artículo científico (JournalArticle)

Vertically scanned laser sheet microscopy

  • Dong, Di
  • Arranz, Alicia
  • Zhu, Shouping
  • Yang, Yujie
  • Wang, Jun
  • Shen, Chen
  • Tian, Jie
  • Ripoll Lorenzo, Jorge
Laser sheet microscopy is a widely used imaging technique for imaging the three-dimensional distribution of a fluorescence signal in fixed tissue or small organisms. In laser sheet microscopy, the stripe artifacts caused by high absorption or high scattering structures are very common, greatly affecting image quality. To solve this problem, we report here a two-step procedure which consists of continuously acquiring laser sheet images while vertically displacing the sample, and then using the variational stationary noise remover (VSNR) method to further reduce the remaining stripes. Images from a cleared murine colon acquired with a vertical scan are compared with common stitching procedures demonstrating that vertically scanned light sheet microscopy greatly improves the performance of current light sheet microscopy approaches without the need for complex changes to the imaging setup and allows imaging of elongated samples, extending the field of view in the vertical direction., This work was supported in part by the Bill and Melinda Gates Foundation, the National Basic Research Program of China (973 Program) under Grant No. 2011CB707700, the National Natural Science Foundation of China under Grant No. 81227901, 81027002, 61231004, and 81101095, the Fellowship for Young International Scientists of the Chinese Academy of Sciences under Grant No. 2010Y2GA03, and the Instrument Developing Project of the Chinese Academy of Sciences under Grant No. YZ201164. A. Arranz acknowledges support from the Marie Curie Intra-European Fellowship program IEF-2010-275137. J.R. acknowledges support from EC FP7 IMI project PREDICT-TB, the EC FP7 CIG grant HIGHTHROUGHPUT TOMO, and the Spanish MINECO project grant FIS2013-41802-R MESO-IMAGING.
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publicación Artículo científico (JournalArticle)

In-vivo Optical Tomography of Small Scattering Specimens: time-lapse 3D imaging of the head eversion process in Drosophila melanogaster

  • Arranz, Alicia
  • Dong, Di
  • Zhu, Shouping
  • Savakis, Charalambos
  • Tian, Jie
  • Ripoll Lorenzo, Jorge
5 fig., Even though in vivo imaging approaches have witnessed several new and important developments, specimens that exhibit high light scattering properties such as Drosophila melanogaster pupae are still not easily accessible with current optical imaging techniques, obtaining images only from subsurface features. This means that in order to obtain 3D volumetric information these specimens need to be studied either after fixation and a chemical clearing process, through an imaging window - thus perturbing physiological development -, or during early stages of development when the scattering contribution is negligible. In this paper we showcase how Optical Projection Tomography may be used to obtain volumetric images of the head eversion process in vivo in Drosophila melanogaster pupae, both in control and headless mutant specimens. Additionally, we demonstrate the use of Helical Optical Projection Tomography (hOPT) as a tool for high throughput 4D-imaging of several specimens simultaneously., This work was supported in part by Project ‘‘THALES – BSRC ‘Alexander Fleming’ – Development and employment of Minos-based genetic and functional genomic technologies in model organisms (MINOS)’’ – MIS: 376898, the Fellowship for Young International Scientist of the Chinese Academy of Sciences Grant No. 2010Y2GA03 and the NSFC-NIH Biomedical collaborative research program 81261120414. A. Arranz acknowledges support from Marie Curie Intra-European Fellowship Program FP7-PEOPLE-2010-IEF. J. Ripoll acknowledges support from EC FP7 CIG grant HIGH-THROUGHPUT TOMO, and Spanish MINECO grant MESO-IMAGING FIS2013-41802-R.
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publicación Artículo científico (JournalArticle)

Helical Optical Projection Tomography

  • Arranz, Alicia
  • Dong, Di
  • Zhu, Shouping
  • Rudin, Markus
  • Tsatsanis, Christos
  • Tian, Jie
  • Ripoll Lorenzo, Jorge
A new technique termed Helical Optical Projection Tomography (hOPT) has been developed with the aim to overcome some of the limitations of current 3D optical imaging techniques. hOPT is based on Optical Projection Tomography (OPT) with the major difference that there is a translation of the sample in the vertical direction during the image acquisition process, requiring a new approach to image reconstruction. Contrary to OPT, hOPT makes possible to obtain 3D-optical images of intact long samples without imposing limits on the sample length. This has been tested using hOPT to image long murine tissue samples such as spinal cords and large intestines. Moreover, 3D-reconstructed images of the colon of DSS-treated mice, a model for Inflammatory Bowel Disease, allowed the identification of the structural alterations. Finally, the geometry of the hOPT device facilitates the addition of a Selective Plane Illumination Microscopy (SPIM) arm, providing the possibility of delivering high resolution images of selected areas together with complete volumetric information, This work was partially supported by EC FP7 collaborative grant FMT-XCT and the Bill and Melinda Gates foundation. A.A. wishes to acknowledge support from Marie Curie IEF-2010-275137. J.R. wishes to acknowledge support from EC FP7 IMI project PREDICT-TB, and the EC FP7 CIG grant HIGH-THROUGHPUT TOMO. D.D., S.Z. and J.T. acknowledge support from the National Basic Research Program of China (973 Program) under Grant 2011CB707700, the Fellowship for Young International Scientists of the Chinese Academy of Sciences under Grant 2010Y2GA03, the National Natural Science Foundation of China under Grant 81101084 and Instrument Developing Project of the Chinese Academy of Sciences under Grant No. YZ201164, Publicado
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publicación Artículo científico (JournalArticle)

Polarization-sensitive optical projection tomography for muscle fiber imaging

  • Fang, Mengjie
  • Dong, Di
  • Zeng, Chaoting
  • Liang, Xiao
  • Yang, Xin
  • Arranz de Miguel, Alicia
  • Ripoll Lorenzo, Jorge
  • Hui, Hui
  • Tian, Jie
Optical projection tomography (OPT) is a tool used for three-dimensional imaging of millimeter-scale biological samples, with the advantage of exhibiting isotropic resolution typically in the micron range. OPT can be divided into two types: transmission OPT (tOPT) and emission OPT (eOPT). Compared with eOPT, tOPT discriminates different tissues based on their absorption coefficient, either intrinsic or after specific staining. However, it fails to distinguish muscle fibers whose absorption coefficients are similar to surrounding tissues. To circumvent this problem, in this article we demonstrate a polarization sensitive OPT system which improves the detection and 3D imaging of muscle fibers by using polarized light. We also developed image acquisition and processing protocols that, together with the system, enable the clear visualization of muscles. Experimental results show that the muscle fibers of diaphragm and stomach, difficult to be distinguished in regular tOPT, were clearly displayed in our system, proving its potential use. Moreover, polarization sensitive OPT was fused with tOPT to investigate the stomach tissue comprehensively. Future applications of polarization sensitive OPT could be imaging other fiberlike structures such as myocardium or other tissues presenting high optical anisotropy., This work is supported by the National Basic Research Program of China (973 Program) under Grant 2011CB707700, the National Natural Science Foundation of China under Grant No. 81227901, 61231004, 81501616, 81301346, 81527805 the Chinese Academy of Sciences Fellowship for Young Foreign Scientists under Grant No. 2010Y2GA03, 2013Y1GA0004, the Chinese Academy of Sciences Visiting Professorship for Senior International Scientists under Grant No. 2012T1G0036, 2013T1G0013, the Instrument Developing Project of the Chinese Academy of Sciences under Grant No. YZ201502, YZ201457 and the Strategic Priority Research Program (B) of Chinese Academy of Sciences (XDB02060010). A. Arranz acknowledges support from the Marie Curie Intra-European Fellowship program IEF-2010-275137. J.R. acknowledges support from EC FP7 IMI project PREDICT-TB, the EC FP7 CIG grant HIGH-THROUGHPUT TOMO, and the Spanish MINECO project grant FIS2013-41802-R MESO-IMAGING.