Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 15
Encontrada(s) 1 página(s)

Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Connection of neighboring wastewater treatment plants: Economic and environmental assessment

  • Morera Carbonell, Sadurní
  • Comas Matas, Joaquim
  • Poch, Manuel
  • Corominas Tabares, Lluís
This paper explores the potential of integrated management of neighboring wastewater treatment plants (WWTPs). The novelty lies in the integration of environmental aspects, with the application of life cycle assessment (LCA) methodology, together with economic criteria for the selection of best alternatives. A case study illustrates how the connection of neighboring wastewater systems by constructing an extra pipeline provides positive results in the economic assessment, and in the majority of the LCA categories used in the global environmental assessment. The consideration of local environmental constraints suggests that the usage of the connection should be limited to periods when the minimum ecological flow in the river section between the discharges of the two WWTPs is maintained. In this particular case, the scenario that promotes the usage of the connection between the two WWTPs (but with some restrictions in dry weather periods) is preferred because it provides cost savings of 45,053€·year-1 and satisfies environmental criteria. A scenario analysis has been conducted to evaluate the influence of the pipe length on both economic and environmental aspects and the influence of individual cost terms on the economic assessment, The authors would like to thank Consorci per la Defensa de la Conca del Riu Bes os (CDCRB) (especially A. Freix o, C. Turon and J. Arr aez) for providing the case-study and the required data as well as the Spanish Ministry of Science and Innovation for funding (CTM-2009-13018 and RYC-2013-14595), and the European Union (ECOTECH-SUDOE Project SOE2/P2/E377, Marie Curie Career Integration Grant PCIG9-GA-2011-293535 and Marie Curie SANITAS ITN Project GA 289193). Serni Morera's FI scholarship and Voltes, S.L.U., for the technical advice and information for the inventory of the pipeline construction provided, are also acknowledged. LEQUIA and ICRA were recognised as consolidated research groups by the Catalan Government with codes 2014-SGR-1168 and 2014-SGR-291, respectively
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Life cycle assessment applied to wastewater treatment: State of the art

  • Corominas Tabares, Lluís
  • Foley, Jeff
  • Guest, J.S.
  • Hospido, Almudena
  • Larsen, H.F.
  • Morera Carbonell, Sadurní
  • Shaw, Andrew R.
Life cycle assessment (LCA) is a technique to quantify the impacts associated with a product, service or process from cradle-to-grave perspective. Within the field of wastewater treatment (WWT) LCA was first applied in the 1990s. In the pursuit of more environmentally sustainable WWT, it is clear that LCA is a valuable tool to elucidate the broader environmental impacts of design and operation decisions. With growing interest from utilities, practitioners, and researchers in the use of LCA in WWT systems, it is important to make a review of what has been achieved and describe the challenges for the forthcoming years. This work presents a comprehensive review of 45 papers dealing with WWT and LCA. The analysis of the papers showed that within the constraints of the ISO standards, there is variability in the definition of the functional unit and the system boundaries, the selection of the impact assessment methodology and the procedure followed for interpreting the results. The need for stricter adherence to ISO methodological standards to ensure quality and transparency is made clear and emerging challenges for LCA applications in WWT are discussed, including: a paradigm shift from pollutant removal to resource recovery, the adaptation of LCA methodologies to new target compounds, the development of regional factors, the improvement of the data quality and the reduction of uncertainty. Finally, the need for better integration and communication with decision-makers is highlighted, The authors would like to thank the Spanish Ministry of Science and Innovation (ENDERUS, CTM-2009-13018) and the European Union for FEDER funding. Lluís Corominas holds a Juan de la Cierva scholarship (jci-2009-05604) and was awarded the Marie Curie Career Integration Grant PCIG9-GA-2011- 293535. Almudena Hospido belongs to the Galician Competitive Research Group GRC2010/37 and she acknowledges the NOVEDAR_Consolider project (CSD2007-00055) funded by the Spanish Ministry of Education and Science
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Life cycle assessment of construction and renovation of sewer systems using a detailed inventory tool

  • Morera Carbonell, Sadurní
  • Remy, Christian
  • Comas Matas, Joaquim
  • Corominas Tabares, Lluís
Purpose: The objective was to provide comprehensive life cycle inventories for the construction and renovation of sewers. A detailed inventory was provided with multiple options of pipe materials, diameters and site-specific characteristics, and was embedded into the Excel ® -based tool SewerLCA. The tool allows for life cycle evaluation of different sewers. It was applied to determine the most important phases, processes, and related parameters involved in the construction and renovation of sewers from an environmental and economical perspective. Methods: Comprehensive life cycle inventories (LCIs) for sewers construction and renovation were obtained by first identifying all processes involved after interviewing construction experts and reviewing sewer construction budgets from a Catalan company; and second transforming the processes into masses of materials and energy usage using construction databases. In order to run the life cycle impact assessment (LCIA) the materials and energy typologies from the inventories were matched to their corresponding equivalents into available LCI databases. Afterwards the potential impacts were calculated through the use of LCIA characterization factors from ReCiPe. Life cycle assessment (LCA) was run several times to assess the construction of a 1-km-long sewer with varying pipe materials, life spans for each material, diameters, transport distances, site-specific characteristics, and pipe deposition options. Results and discussion: The environmental impacts generated by construction and renovation of a 1 km Polyvinylchloride (PVC) pipe with a diameter of 40 cm are mainly associated with pipe laying and backfilling of the trench. The evaluation of several pipe materials and diameters shows that the exclusion of renovation would underestimate the impacts by 38 to 82 % depending on the pipe materials and diameters. Including end-of-life phase for plastic pipe materials increases climate change (up to an extra 71 %) and human toxicity (up to an extra 147 %) impacts (among all diameters). The preferred pipe materials from an environmental point of view are precast concrete and High-Density Polyethylene (HDPE). Site-specific characteristics (specially the presence of rocky soil and asphalt placement) and material life span have a high influence on the overall environmental profile, whereas changes in transport distances have only a minor impact ( < 4 %). Conclusions: Environmental impacts during the construction and renovation of sewers are subject to differences in material type, site-specific characteristics and material life span. Renovation of sewers has a large influence on all potential environmental impacts and costs and, hence, should not be omitted in LCA studies. The treatment and disposal processes of plastic pipes at the end of their life has to be accounted in LCA studies, The authors would like to thank Voltes S.L.U. for the technical support, Banc BEDEC, the Ramon and Cajal grant from Lluís Corominas RYC-2013-14595), Marie Curie Career Integration Grant PCIG9-GA-2011-293535 and Marie Curie SANITAS ITN Project GA 289193), Waterfate project (CTM2012-38314-C0201). Serni Morera’s FI scholarship (2015FI_B2 00071), STSMscholarship from EU-Cost Action Water2020 (ECOST-STSM-ES1202-110614-044095). LEQUIA and ICRA were recognized as consolidated research groups by the Catalan Government with codes 2014-SGR-1168 and 2014-SGR-291, respectively
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Balancing effluent quality, economic cost and greenhouse gas emissions during the evaluation of (plant-wide) control/operational strategies in WWTPs

  • Flores Alsina, Xavier
  • Arnell, Magnus
  • Amerlinck, Youri
  • Vanrolleghem, Peter A.
  • Corominas Tabares, Lluís
  • Gernaey, Krist V.
  • Guo, Lisha
  • Lindblom, Erik U.
  • Nopens, Ingmar
  • Porro, Jose
  • Shaw, Andrew R.
  • Snip, Laura J.P.
  • Vanrolleghem, Peter A.
  • Jeppsson, Ulf
The objective of this paper was to show the potential additional insight that result from adding greenhouse gas (GHG) emissions to plant performance evaluation criteria, such as effluent quality (EQI) and operational cost (OCI) indices, when evaluating (plant-wide) control/operational strategies in wastewater treatment plants (WWTPs). The proposed GHG evaluation is based on a set of comprehensive dynamic models that estimate the most significant potential on-site and off-site sources of CO2, CH4 and N2O. The study calculates and discusses the changes in EQI, OCI and the emission of GHGs as a consequence of varying the following four process variables: (i) the set point of aeration control in the activated sludge section; (ii) the removal efficiency of total suspended solids (TSS) in the primary clarifier; (iii) the temperature in the anaerobic digester; and (iv) the control of the flow of anaerobic digester supernatants coming from sludge treatment. Based upon the assumptions built into the model structures, simulation results highlight the potential undesirable effects of increased GHG production when carrying out local energy optimization of the aeration system in the activated sludge section and energy recovery from the AD. Although off-site CO2 emissions may decrease, the effect is counterbalanced by increased N2O emissions, especially since N2O has a 300-fold stronger greenhouse effect than CO2. The reported results emphasize the importance and usefulness of using multiple evaluation criteria to compare and evaluate (plant-wide) control strategies in a WWTP for more informed operational decision making
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Field validation of a new low-cost method for determining occurrence and duration of combined sewer overflows

  • Montserrat Royuela, Albert
  • Gutiérrez Garcia-Moreno, Oriol
  • Poch, Manuel
  • Corominas Tabares, Lluís
Combined sewer overflow (CSO) events produced in combined sewer systems (CSS) during wet weather conditions are a threat for the receiving water bodies. The large number of CSO structures normally present in a CSS makes that the monitoring of the complete CSO network in a simultaneous way would drastically increase the investment costs. In this paper, a new methodology is presented aiming to characterize the occurrence and duration of CSO events by means of low-cost temperature sensors. Hence, a large number of CSO structures can be simultaneously monitored and the system can be characterized as a whole. The method assumes temperature differences between the overflowing mix of wastewater and stormwater and the sewer gas phase, so the temperature shift produced during a rainfall episode is related to a CSO event occurrence. The method has been tested and validated in La Garriga CSS (Spain) where the temperature at 13 CSO weirs was monitored for a period of 1. year (57 rainfall episodes). For the whole set of CSO events, occurrence and duration were successfully determined in 80% of cases. Advantages, limitations and potential applications of the method are discussed at the end of the paper, The authors would like to thank Consorci per la Defensa de la Conca del Riu Besòs (CDCRB), the Spanish Ministry of Science and Innovation (ENDERUS) (CTM-2009-13018), Spanish National Project (CTM-2011-27163), Juan de la Cierva (jci-2009-05604, FPI BES-2010-039247), and European Union (FEDER-CTM2009-13018). In additionwould like to thank to the staff from Drenatges Urbans del Besòs for their constant support. Also the Marie Curie IRG within the 7th European Community Framework Programme, FP7-People-2010-IRG-277050 and a Marie Curie Career Integration Grant PCIG9-GA-2011-293535
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Assessing Urban Wastewater System Upgrades Using Integrated Modeling, Life Cycle Analysis, and Shadow Pricing

  • Hadjimichael, Antonia
  • Morera Carbonell, Sadurní
  • Benedetti, Lorenzo
  • Flameling, Tony
  • Corominas Tabares, Lluís
  • Weijers, Stefan
  • Comas Matas, Joaquim
This study assesses the environmental impacts of four measures proposed for upgrading of the urban wastewater system of Eindhoven and the Dommel River in The Netherlands, against the base case, “do-nothing” option. The measures aim to reduce the overall environmental impact of the Eindhoven urban wastewater system (UWS) by targeting river dissolved oxygen depletion and ammonia peaks, reducing combined sewer overflows, and enhancing nutrient removal. The measures are evaluated using a life cycle analysis with the boundaries including the receiving river section by means of an integrated model of the UWS. An uncertainty analysis of the estimated impacts has been performed to support the outcomes. The study also uses the economic concept of shadow prices to assign relative weights of socio-economic importance to the estimated life cycle impacts. This novel integration of tools complements the assessments of this UWS with the inclusion of long-term global environmental impacts and the investigation of trade-offs between different environmental impacts through a single monetary unit. The results support the selection of deeper clarifiers as the most environmentally beneficial measure for upgrade, The authors would like to acknowledge the People Programme (Marie Curie Actions) of the European Union’s Seventh Framework Programme FP7/2007−2013 under REA agreement 289193 (SANITAS ITN). The authors thank the Spanish Ministry of Science and Innovation (Ramon y Cajal RYC-2013-14595 and CTM 2015-66892-R) and the European Union (Marie Curie Career Integration Grant PCIG9-GA-2011-293535). The authors also acknowledge support from the Economy and Knowledge Department of the Catalan Government through the Consolidated Research Group (2014-SGR- 1168)-LEQUIA-University of Girona and (2014 SGR 291)- Catalan Institute for Water Research
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Using data from monitoring combined sewer overflows to assess, improve, and maintain combined sewer systems

  • Montserrat Royuela, Albert
  • Bosch, Ll.
  • Kiser, M.A.
  • Poch, Manuel
  • Corominas Tabares, Lluís
Using low-cost sensors, data can be collected on the occurrence and duration of overflows in each combined sewer overflow (CSO) structure in a combined sewer system (CSS). The collection and analysis of real data can be used to assess, improve, and maintain CSSs in order to reduce the number and impact of overflows. The objective of this study was to develop a methodology to evaluate the performance of CSSs using low-cost monitoring. This methodology includes (1) assessing the capacity of a CSS using overflow duration and rain volume data, (2) characterizing the performance of CSO structures with statistics, (3) evaluating the compliance of a CSS with government guidelines, and (4) generating decision tree models to provide support to managers for making decisions about system maintenance. The methodology is demonstrated with a case study of a CSS in La Garriga, Spain. The rain volume breaking point from which CSO structures started to overflow ranged from 0.6. mm to 2.8. mm. The structures with the best and worst performance in terms of overflow (overflow probability, order, duration and CSO ranking) were characterized. Most of the obtained decision trees to predict overflows from rain data had accuracies ranging from 70% to 83%. The results obtained from the proposed methodology can greatly support managers and engineers dealing with real-world problems, improvements, and maintenance of CSSs, Support for this project was provided by the ENDERUS Project (CTM-2009-13018) and the predoctoral grant FPI BES-2010-039247, founded by the Spanish Ministry of Science and Innovation. Lluís Corominas received the postdoctoral Juan de la Cierva grant (JCI-2009-05604) from the Government of Spain and the Career Integration Grant (PCIG9-GA-2011-293535) from the EU. The authors also acknowledge the support from the Economy and Knowledge Department of the Catalan Government through the Consolidated Research Group (2014 SGR 291)–Catalan Institute for Water Research
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Water footprint assessment in wastewater treatment plants

  • Morera Carbonell, Sadurní
  • Corominas Tabares, Lluís
  • Poch, Manuel
  • Aldaya, M.M.
  • Comas Matas, Joaquim
Wastewater treatment plants (WWTPs) play an important role within the urbanwater cycle in protecting receiving waters from untreated discharges. However, WWTPs processes also affect the environment. Life cycle assessment has traditionally been used to assess the impact of direct discharges from WWTPs and indirect emissions related to energy or chemical production. The water footprint (WF) can provide complementary information to evaluate the impact of a WWTP regarding the use of freshwater. This paper presents the adoption of the Water Footprint Assessment methodology to assess the consumption of water resources in WWTPs by considering both blue and grey WFs. The usefulness of the proposed methodology in assessing the environmental impact and the benefits from WWTP discharge to a river is illustrated with an actual WWTP, which treats 4,000 m3$d 1, using three scenarios: no treatment, secondary treatment and phosphorus removal. A reduction of the water footprint by 51.5% and 72.4% was achieved using secondary treatment and chemical phosphorus removal, respectively, to fulfill the legal limits. These results indicate that when treating wastewater, there is a large decrease in the grey water footprint compared with the no-treatment scenario; however, there is a small blue water footprint, The authors would like to thank the Spanish Ministry of Science and Innovation (PCIN-2013-074) and the European Union (Marie Curie Career Integration Grant PCIG9-GA-2011-293535 and SANITAS ITN Project agreement 289193). Serni Morera was awarded an FI scholarship from the Catalan Government (2015FI_B2 00071). Lluís Corominas received the Career Integration Grant (PCIG9-GA-2011-293535) from the EU and the Ramon y Cajal Grant (RYC-2013-14595) from Spanish Government. LEQUIA has been recognized as a consolidated research group by the Catalan Government with code2014-SGR-1168. The authors also acknowledge the support from the Economy and Knowledge Department of the Catalan Government through the Consolidated Research Group (2014-SGR-291) e Catalan Institute for Water Research
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Generation of synthetic influent data to perform (micro)pollutant wastewater treatment modelling studies

  • Snip, Laura J.P.
  • Flores Alsina, Xavier
  • Aymerich Blazquez, Ignasi
  • Rodríguez Mozaz, Sara
  • Barceló i Cullerés, Damià
  • Plósz, B. G.
  • Corominas Tabares, Lluís
  • Rodríguez-Roda Layret, Ignasi
  • Jeppsson, Ulf
  • Gernaey, Krist V.
The use of process models to simulate the fate of micropollutants in wastewater treatment plants is constantly growing. However, due to the high workload and cost of measuring campaigns, many simulation studies lack sufficiently long time series representing realistic wastewater influent dynamics. In this paper, the feasibility of the Benchmark Simulation Model No. 2 (BSM2) influent generator is tested to create realistic dynamic influent (micro)pollutant disturbance scenarios. The presented set of models is adjusted to describe the occurrence of three pharmaceutical compounds and one of each of its metabolites with samples taken every 2–4 h: the anti-inflammatory drug ibuprofen (IBU), the antibiotic sulfamethoxazole (SMX) and the psychoactive carbamazepine (CMZ). Information about type of excretion and total consumption rates forms the basis for creating the data-defined profiles used to generate the dynamic time series. In addition, the traditional influent characteristics such as flow rate, ammonium, particulate chemical oxygen demand and temperature are also modelled using the same framework with high frequency data. The calibration is performed semi-automatically with two different methods depending on data availability. The ‘traditional’ variables are calibrated with the Bootstrap method while the pharmaceutical loads are estimated with a least squares approach. The simulation results demonstrate that the BSM2 influent generator can describe the dynamics of both traditional variables and pharmaceuticals. Lastly, the study is complemented with: 1) the generation of longer time series for IBU following the same catchment principles; 2) the study of the impact of in-sewer SMX biotransformation when estimating the average daily load; and, 3) a critical discussion of the results, and the future opportunities of the presented approach balancing model structure/calibration procedure complexity versus predictive capabilities, The authors acknowledge the People Program (Marie Curie Actions) of the European Union's Seventh Framework Program FP7/2007-2013 under REA agreement 289193 (SANITAS), REA agreement 329349 (PROTEUS) and the European Union (Marie Curie Career Integration Grant PCIG9-GA-2011-293535). Dr Flores-Alsina gratefully acknowledges the financial support of the collaborative international consortium WATERJPI2015 WATINTECH of the Water Challenges for a Changing World Joint Programming Initiative (Water JPI) 2015 call. Additionally, the Spanish Ministry of Science and Innovation (Ramon y Cajal, RYC-2013-14595), Ministry of Economy and Competitiveness (CTM2012-38314-C02-01 (WATERFATE)) and the Economy and Knowledge Department of the Catalan Government through the Consolidated Research Group (2014 SGR 291) - Catalan Institute for Water Research are acknowledged
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

The difference between energy consumption and energy cost: Modelling energy tariff structures for water resource recovery facilities

  • Aymerich Blazquez, Ignasi
  • Rieger, L.
  • Sobhani, R.
  • Rosso, D.
  • Corominas Tabares, Lluís
The objective of this paper is to demonstrate the importance of incorporating more realistic energy cost models (based on current energy tariff structures) into existing water resource recovery facilities (WRRFs) process models when evaluating technologies and cost-saving control strategies. In this paper, we first introduce a systematic framework to model energy usage at WRRFs and a generalized structure to describe energy tariffs including the most common billing terms. Secondly, this paper introduces a detailed energy cost model based on a Spanish energy tariff structure coupled with a WRRF process model to evaluate several control strategies and provide insights into the selection of the contracted power structure. The results for a 1-year evaluation on a 115,000 population-equivalent WRRF showed monthly cost differences ranging from 7 to 30% when comparing the detailed energy cost model to an average energy price. The evaluation of different aeration control strategies also showed that using average energy prices and neglecting energy tariff structures may lead to biased conclusions when selecting operating strategies or comparing technologies or equipment. The proposed framework demonstrated that for cost minimization, control strategies should be paired with a specific optimal contracted power. Hence, the design of operational and control strategies must take into account the local energy tariff, The authors would like to thank the Spanish Ministry of Economy and Competitiveness for funding (RYC-2013-14595 and CTM2012-38314-C02-01), and the European Union Marie Curie Career Integration Grant PCIG9-GA-2011-293535. ICRA was recognised as consolidated research groups by the Catalan Government with the code 2014-SGR-291. The usefulness of the energy cost model is now being demonstrated within the framework of the R3water project funded by EU (FP7, Grant agreement no: 619093)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Placing ecosystem services at the heart of urban water systems management

  • Garcia Acosta, Xavier
  • Barceló i Cullerés, Damià
  • Comas Matas, Joaquim
  • Corominas Tabares, Lluís
  • Hadjimichael, Antonia
  • Page, T.J.
  • Acuña, Vicenç
Current approaches have failed to deliver a truly integrated management of the different elements of the urban water system, such as freshwater ecosystems, drinking water treatment plants, distribution networks, sewer systems and wastewater treatment plants. Because the different parts of urban water have not been well integrated, poor decisions have been made for society in general, leading to the misuse of water resources, the degradation of freshwater ecosystems and increased overall treatment costs. Some attempts to solve environmental issues have adopted the ecosystem services concept in a more integrated approach, however this has rarely strayed far away from pure policy, and has made little impact in on-the-ground operational matters. Here, we present an improved decision-making framework to integrate the management of urban water systems. This framework uses the ecosystem service concept in a practical way to make a better use of both financial and water resources, while continuing to preserve the environment, This research was supported by the European Communities 7thFramework Programme (SANITAS ITN Project agreement 289193); as well as by the individual fellowships Ramon y Cajal (RYC-2013-14595) and Marie Curie Career Integration Fellowship (PCIG9-GA-2011-293535) to Lluís Corominas, and a José Castillejo (CAS15-00163) to Vicenç Acuña. Authors also acknowledge the support from the Economy and Knowledge Department of the Catalan Government (Consolidated Research Group 2014 SGR 291 - ICRA).
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Attenuation of pharmaceuticals and their transformation products in a wastewater treatment plant and its receiving river ecos

  • Aymerich Blazquez, Ignasi
  • Acuña, Vicenç
  • Barceló i Cullerés, Damià
  • García-Galán, Maria Jesús
  • Petrović, Mira
  • Poch, Manuel
  • Rodríguez Mozaz, Sara
  • Rodríguez-Roda Layret, Ignasi
  • Sabater, Sergi
  • von Schiller, Daniel
  • Corominas Tabares, Lluís
Pharmaceuticals are designed to improve human and animal health, but may also be a threat to freshwater ecosystems, particularly after receiving urban or wastewater treatment plant (WWTP) effluents. Knowledge on the fate and attenuation of pharmaceuticals in engineered and natural ecosystems is rather fragmented, and comparable methods are needed to facilitate the comprehension of those processes amongst systems. In this study the dynamics of 8 pharmaceuticals (acetaminophen, sulfapyridine, sulfamethoxazole, carbamazepine, venlafaxine, ibuprofen, diclofenac, diazepam) and 11 of their transformation products were investigated in a WWTP and the associated receiving river ecosystem. During 3 days, concentrations of these compounds were quantified at the influents, effluents, and wastage of the WWTP, and at different distances downstream the effluent at the river. Attenuation (net balance between removal and release from and to the water column) was estimated in both engineered and natural systems using a comparable model-based approach by considering different uncertainty sources (e.g. chemical analysis, sampling, and flow measurements). Results showed that pharmaceuticals load reduction was higher in the WWTP, but attenuation efficiencies (as half-life times) were higher in the river. In particular, the load of only 5 out of the 19 pharmaceuticals was reduced by more than 90% at the WWTP, while the rest were only partially or non-attenuated (or released) and discharged into the receiving river. At the river, only the load of ibuprofen was reduced by more than 50% (out of the 6 parent compounds present in the river), while partial and non-attenuation (or release) was observed for some of their transformation products. Linkages in the routing of some pharmaceuticals (venlafaxine, carbamazepine, ibuprofen and diclofenac) and their corresponding transformation products were also identified at both WWTP and river. Finally, the followed procedure showed that dynamic attenuation in the coupled WWTP-river system could be successfully predicted with simple first order attenuation kinetics for most modeled compounds, This research was supported by the European Communities 7th Framework Programme Marie Curie Career Integration Grant PCIG9-GA-2011-293535. Authors also acknowledge the support from the Economy and Knowledge Department of the Catalan Government (Consolidated Research Group 2014 SGR 291 - ICRA) and the Spanish Ministry of Economy and Competitiveness for funding (CTM2015- 66892-R, CTM2012-38314-C02-01 and RYC-2013-14595)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Analysis of the uncertainty in the monetary valuation of ecosystem services: a case study at the river basin scale

  • Boithias, Laurie
  • Terrado, Marta
  • Corominas Tabares, Lluís
  • Ziv, Guy
  • Kumar, Vikas
  • Marquès, Montse
  • Schuhmacher, Marta
  • Acuña, Vicenç
Ecosystem services provide multiple benefits to human wellbeing and are increasingly considered by policy-makers in environmental management. However, the uncertainty related with the monetary valuation of these benefits is not yet adequately defined or integrated by policy-makers. Given this background, our aim was to quantify different sources of uncertainty when performing monetary valuation of ecosystem services, in order to provide a series of guidelines to reduce them. With an example of 4 ecosystem services (i.e., water provisioning, waste treatment, erosion protection, and habitat for species) provided at the river basin scale, we quantified the uncertainty associated with the following sources: (1) the number of services considered, (2) the number of benefits considered for each service, (3) the valuation metrics (i.e. valuation methods) used to value benefits, and (4) the uncertainty of the parameters included in the valuation metrics. Results indicate that the highest uncertainty was caused by the number of services considered, as well as by the number of benefits considered for each service, whereas the parametric uncertainty was similar to the one related to the selection of valuation metric, thus suggesting that the parametric uncertainty, which is the only uncertainty type commonly considered, was less critical than the structural uncertainty, which is in turn mainly dependent on the decision-making context. Given the uncertainty associated to the valuation structure, special attention should be given to the selection of services, benefits and metrics according to a given context, This research was supported by the Spanish Ministry of Economy and Competitiveness through the project SCARCE (Consolider-Ingenio 2010 CSD2009-00065), the postdoctoral grant “Juan de la Cierva” (JC2011-09116, to MT), and the Ramón y Cajal grant (RYC-2013-14595, to LC), as well as by a Marie Curie European Reintegration Grant (PERG07-GA-2010-259219, to VA), and a Marie Curie Career Integration Grant (PCIG9-GA-2011-293535, to LC).
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Life cycle assessment of urban wastewater systems: Quantifying the relative contribution of sewer systems

  • Risch, Eva
  • Gutiérrez Garcia-Moreno, Oriol
  • Roux, Philippe
  • Boutin, Catherine
  • Corominas Tabares, Lluís
This study aims to propose a holistic, life cycle assessment (LCA) of urban wastewater systems (UWS) based on a comprehensive inventory including detailed construction and operation of sewer systems and wastewater treatment plants (WWTPs). For the first time, the inventory of sewers infrastructure construction includes piping materials and aggregates, manholes, connections, civil works and road rehabilitation. The operation stage comprises energy consumption in pumping stations together with air emissions of methane and hydrogen sulphide, and water emissions from sewer leaks. Using a real case study, this LCA aims to quantify the contributions of sewer systems to the total environmental impacts of the UWS. The results show that the construction of sewer infrastructures has an environmental impact (on half of the 18 studied impact categories) larger than both the construction and operation of the WWTP. This study highlights the importance of including the construction and operation of sewer systems in the environmental assessment of centralised versus decentralised options for UWS, ICRA authors also acknowledge the Marie Curie EU Reintegration grants 2010-RG-277050 and PCIG9-GA-2011-293535, the EU-ITN SANITAS (ITN – 289193), the Spanish government (CTM 2011-27163; RYC-2013-14595) and the support from the Economy and Knowledge Department of the Catalan Government through the Consolidated Research Group (2014 SGR 291)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Integration of freshwater environmental policies and wastewater treatment plant management

  • Corominas Tabares, Lluís
  • Acuña, Vicenç
  • Ginebreda, Antoni
  • Poch, Manuel
In the last decade the political awareness of river water quality issues has grown substantially over the world and legislation is accordingly adapting. In the European Union (EU), two different directives regulate separately the characteristics of the discharged water and the chemical status of the receiving freshwater ecosystem. On the one hand, the characteristics of the urban effluents are regulated by the EU Directive 91/271/EEC, which defines limits on different elements set in the form of both static emission limits and minimum percentage load reductions. On the other hand, the characteristics of the receiving freshwater ecosystems are described in the EU Water Framework Directive (2000/60/EEC), which sets minimum 'good' chemical and ecological status in water bodies that should be achieved by 2015, and aims for an ecosystem-based management. With the support of an example, we show that there is a gap in these EU environmental policies leading to non-integrated management, which may result on adverse environmental and economical consequences. We believe that these policies should be updated and tuned to account for an integrated perspective, allowing a more efficient and sustainable management of wastewater treatment plants, maximizing the ecological, economical and social benefits of the system as a whole, This research was supported by a Marie Curie Career Integration Grant (PCIG9-GA-2011-293535) and by a Marie Curie European Reintegration Grant (PERG07-GA-2010-259219) within the 7th European Community Framework Programme, aswell as by the Spanish Ministry of Economy and Competitiveness for its financial support through the projects ENDERUS (CTM-2009-13018) and SCARCE (Consolider-Ingenio 2010 CSD2009-00065) and the postdoctoral grant “Juan de la Cierva” (jci-2009-05604). The authors would like to thank the “Consorci per la Defensa de la Conca del Riu Besòs” (CDCRB) for providing the data of the Garriga system