Pasar al contenido principal

MODELADO, CONTROL Y SISTEMAS DE AYUDA A LA DECISION AVANZADOS PARA EL DISEÑO Y OPERACION DE SISTEMAS DE SANEAMIENTO DE AGUAS RESIDUALES FLEXIBLES Y OPTIMOS.

PCIN-2013-074

•
Nombre agencia financiadora Ministerio de Economía y Competitividad
Acrónimo agencia financiadora MINECO
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos Programación Conjunta Internacional
Año convocatoria 2013
Plan Estatal 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Unidad de gestión Secretaría de Estado de Educación, Formación Profesional y Universidades
Centro beneficiario UNIVERSITAT DE GIRONA
Identificador persistente http://dx.doi.org/10.13039/501100003329

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Towards integrated operation of membrane bioreactors: effects of aeration on biological and filtration performance

  • Dalmau Figueras, Montserrat
  • Monclús Sales, Hèctor
  • Gabarrón Fernández, Sara
  • Rodríguez-Roda Layret, Ignasi
  • Comas Matas, Joaquim
Two experimental studies evaluated the effect of aerobic and membrane aeration changes on sludge properties, biological nutrient removal and filtration processes in a pilot plant membrane bioreactor. The optimal operating conditions were found at an aerobic dissolved oxygen set-point (DO) of 0.5mgO2L-1 and a membrane specific aeration demand (SADm) of 1mh-1, where membrane aeration can be used for nitrification. Under these conditions, a total flow reduction of 42% was achieved (75% energy reduction) without compromising nutrient removal efficiencies, maintaining sludge characteristics and controlled filtration. Below these optimal operating conditions, the nutrient removal efficiency was reduced, increasing 20% for soluble microbial products, 14% for capillarity suction time and reducing a 15% for filterability. Below this DO set-point, fouling increased with a transmembrane pressure 75% higher. SADm below 1mh-1 doubled the values of transmembrane pressure, without recovery after achieving the initial conditions, The research leading to these results has received funding from the Spanish Ministry of Economy and Competitiveness (CTM2012-38314-C02-01 and PCIN-2013-074) and from the People Programme (Marie Curie Actions) of the European Union's Seventh Framework Programme (FP7/2007-2013, under REA agreement 289193 (SANITAS) and under REA agreement 600388 (TECNIOSPRING)). This publication reflects only the authors' views, and the European Union is not liable for any use that may be made of the information contained therein. Montse Dalmau received a grant from the Spanish Ministry of Economy and Competitiveness (BES-2010-033288)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Optimization of full-scale membrane bioreactors for wastewater treatment through a model-based approach

  • Gabarrón Fernández, Sara
  • Dalmau Figueras, Montserrat
  • Porro, Jose
  • Rodríguez-Roda Layret, Ignasi
  • Comas Matas, Joaquim
Despite the high number of advantages of membrane bioreactors (MBR), operational costs still remain as one of the main obstacles of this technology. In that sense, a full-scale MBR was studied in order to explore and identify viable optimization strategies for improving effluent quality and reducing operational costs through a model-based approach. Opportunities for optimization strategies, identified through the initial experimental phase, were focused on improving the nitrogen removal efficiencies and reducing the aeration energy costs through the aerobic DO set point and recirculation modifications. A mechanistic model was developed to reproduce the operation of the full-scale MBR and predict the effects of the optimization actions. Moreover, a qualitative risk model was also applied to ensure that the DO set point reduction did not negatively affect the microbiology of the activated sludge. The best viable control scenario was identified and then tested in the full-scale MBR. The results achieved maximum improvements on the nitrogen removal efficiencies of 27% and reduction on the aeration energy (7%) without affecting the sludge properties or the filtration performance. The model approached proved in this study and the optimization strategies identified can be generalized for municipal MBRs, This research was funded by the Catalan Water Agency (ACA), the Ministry of Science and Innovation (CTM2012-38314-C02-01 and PCIN-2013-074) and SANITAS Project (289193).
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Water footprint assessment in wastewater treatment plants

  • Morera Carbonell, Sadurní
  • Corominas Tabares, Lluís
  • Poch, Manuel
  • Aldaya, M.M.
  • Comas Matas, Joaquim
Wastewater treatment plants (WWTPs) play an important role within the urbanwater cycle in protecting receiving waters from untreated discharges. However, WWTPs processes also affect the environment. Life cycle assessment has traditionally been used to assess the impact of direct discharges from WWTPs and indirect emissions related to energy or chemical production. The water footprint (WF) can provide complementary information to evaluate the impact of a WWTP regarding the use of freshwater. This paper presents the adoption of the Water Footprint Assessment methodology to assess the consumption of water resources in WWTPs by considering both blue and grey WFs. The usefulness of the proposed methodology in assessing the environmental impact and the benefits from WWTP discharge to a river is illustrated with an actual WWTP, which treats 4,000 m3$d 1, using three scenarios: no treatment, secondary treatment and phosphorus removal. A reduction of the water footprint by 51.5% and 72.4% was achieved using secondary treatment and chemical phosphorus removal, respectively, to fulfill the legal limits. These results indicate that when treating wastewater, there is a large decrease in the grey water footprint compared with the no-treatment scenario; however, there is a small blue water footprint, The authors would like to thank the Spanish Ministry of Science and Innovation (PCIN-2013-074) and the European Union (Marie Curie Career Integration Grant PCIG9-GA-2011-293535 and SANITAS ITN Project agreement 289193). Serni Morera was awarded an FI scholarship from the Catalan Government (2015FI_B2 00071). Lluís Corominas received the Career Integration Grant (PCIG9-GA-2011-293535) from the EU and the Ramon y Cajal Grant (RYC-2013-14595) from Spanish Government. LEQUIA has been recognized as a consolidated research group by the Catalan Government with code2014-SGR-1168. The authors also acknowledge the support from the Economy and Knowledge Department of the Catalan Government through the Consolidated Research Group (2014-SGR-291) e Catalan Institute for Water Research
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Comparison of a deterministic and a data driven model to describe MBR fouling

  • Dalmau Figueras, Montserrat
  • Atanasova, Nataša
  • Gabarrón Fernández, Sara
  • Rodríguez-Roda Layret, Ignasi
  • Comas Matas, Joaquim
Membrane bioreactors (MBRs) are a combination of activated sludge bioreactors and membrane filtration, enabling high quality effluent with a small footprint. However, they can be beset by fouling, which causes an increase in transmembrane pressure (TMP). Modelling and simulation of changes in TMP could be useful to describe fouling through the identification of the most relevant operating conditions. Using experimental data from a MBR pilot plant operated for 462days, two different models were developed: a deterministic model using activated sludge model n°2d (ASM2d) for the biological component and a resistance in-series model for the filtration component as well as a data-driven model based on multivariable regressions. Once validated, these models were used to describe membrane fouling (as changes in TMP over time) under different operating conditions. The deterministic model performed better at higher temperatures (>20°C), constant operating conditions (DO set-point, membrane air-flow, pH and ORP), and high mixed liquor suspended solids (>6.9gL-1) and flux changes. At low pH (<7) or periods with higher pH changes, the data-driven model was more accurate. Changes in the DO set-point of the aerobic reactor that affected the TMP were also better described by the data-driven model. By combining the use of both models, a better description of fouling can be achieved under different operating conditions, The research leading to these results has received funding from the Spanish Ministry of Economy and Competitiveness (CTM201238314-0O2-01 and PCIN-2013-074) and from the People Programme (Marie Curie Actions) of the European Union's Seventh Framework Programme FP7/2007-2013, under REA agreement 289193 (SANITAS). This publication reflects only the authors' views and the European Union is not liable for any use that may be made of the information contained therein. M.D was granted by the Spanish Ministry of Economy and Competitiveness (BES-2010033288)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

UV/H2O2 degradation of the antidepressants venlafaxine and O-desmethyl venlafaxine: Elucidation of their transformation pathwayand environmental fate

  • García-Galán, Maria Jesús
  • Anfruns Bagaria, Alba
  • González Olmos, Rafael
  • Rodríguez Mozaz, Sara
  • Comas Matas, Joaquim
The aim of the present work is to investigate the removal and transformation of the antidepressants venlafaxine (VFX) and its main metabolite O-desmethylvenlafaxine (DVFX) upon advanced oxidation with UV/H2O2 under lab conditions. High-resolution mass spectrometry (HRMS) analyses were carried out by means of ultra-high pressure liquid chromatography (UHPLC)-linear ion trap high resolution Orbitrap instrument (LTQ-Orbitrap-MS) in order to elucidate the different transformation products (TPs) generated. The depletion of both VFX and DVFX was very significant, with the 99.9% of both compounds eliminated after 5 and 30 min of reaction, respectively. Eleven TPs for VFX and six for DVFX were detected and their molecular structures elucidated by means of MS2 and MS3 scans, and the corresponding degradation pathways were proposed. The combined ecotoxicity at different treatment times was evaluated by means of bioluminescence inhibition assays with the marine bacteria Vibrio fischeri. Results showed an increase in the ecotoxicity during the UV/H2O2 experiment, especially at those reaction times where the total abundance of TPs was higher, AcknowledgementsThe authors would like to thank the European Union (MarieCurie SANITAS ITN Project agreement 289193) and the SpanishMinistry of Science and Innovation (PCIN-2013-074, CTM2012-38314-C02-01 and CTM2013- 48545-C2). This research has alsobeen co-financed by the European Union through the EuropeanRegional Development Fund (ERDF) in the frame of the Catalo-nia ERDF Operative programme 2007–2013. This work was partlysupported by the Generalitat de Catalunya (Consolidated ResearchGroup: Catalan Institute for water Research 2014 SGR 291). R.Gonzalez-Olmos thanks to “Obra Social La Caixa” for fundingthrough the “Electromembrane” (2014-URL-Trac-002)