A metal ion release study of CoCrMo exposed to corrosion and tribocorrosion conditions in simulated body fluids

  • Espallargas, N.
  • Torres, C.
  • Igual Muñoz, Anna Neus
[EN] Several studies have investigated the presence of metal ions in different human fluids (i.e. blood, urine, serum and plasma) of patients using CoCrMo bearing implants. The general conclusion is that the degradation mechanisms of the implants (the joint action of biocorrosion and wear) lead to an increase of dissolved metals and particles leading to implants failure and tissue inflammation. However, the levels of metallic ions in those fluids can vary depending on the involved degradation mechanism of the implant (corrosion or tribocorrosion). Having a tool able to identify the origin of the metal ion concentration in patients using metal bearing implants could allow faster and easier clinical treatments and failure detection. This work has investigated the metal ion release of a low carbon CoCrMo subjected to different electrochemical and tribocorrosion conditions in NaCI, phosphate buffer solution (PBS) and PBS with protein (albumin) at the human body conditions of 37 degrees C. Cobalt is the most concentrated ion and has the largest concentration ratio in all testing conditions, with the exception of the corrosion tests in PBS with albumin. Albumin drastically increases the molybdenum concentration in the electrolyte after corrosion tests at applied potentials below the transpassive region of the alloy. In the tribocorrosion tests, an increase of metal ion concentration with potential was found, while this effect was not observed in the corrosion tests, thus electrode potential variations are critical for metal ion release of CoCrMo alloys under tribocorrosion conditions. Combining ICP-MS analysis with electrochemical testing gives mechanistic information on the involved redox reactions, oxide formation and amount of wear debris in corrosion and tribocorrosion situations of biomedical alloys. This is needed for the interpretation of the in vivo data., The authors would like to thank financial support from NTNU (Project number 69450741) for performing the experiments of this work.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Tribocorrosion Mechanisms of Ti6Al4V in Artificial Saliva by Zero-Resistance Ammetry (ZRA) Technique

  • Licausi, Marie-Pierre
  • Igual Muñoz, Anna Neus
  • Espallargas, N.
  • Amigó, Vicente|||0000-0002-2107-0273
[EN] Degradation mechanisms of biomedical alloys involve two different phenomena, corrosion and wear, which simultaneously act and may cause the failure of implants and prosthesis. In this work, tribocorrosion of Ti6Al4V biomedical alloy in artificial saliva is studied at open circuit potential (OCP) by a new electrochemical technique that allows measuring the galvanic potential and current between the wear track (anode) and the passive material (cathode) through zero-resistance ammetry. The experimental set-up was conceived for physically separating the depassivated area from the passive material, thus allowing to quantify the mechanically activated corrosion at OCP. Two different counterparts, SiC and Al2O3, were used against the Ti6Al4V alloy in order to analyse the influence of the initial contact pressure on the tribocorrosion mechanisms. A galvanic model based on the cathodic reaction kinetics can describe the current and the potential evolution with time during sliding. It has been observed that at the highest initial contact pressures, wear follows the Archard law, while at lower contact pressures, third body appeared and wear can not be described by the Archard law. Quantification of the evolution of the depassivated wear track with time was obtained and the deviation from the Archard predictions was analysed., The authors would like to thank the financial support from NTNU (Project Number 69450741) for performing the experiments of this work and Universitat Politècnica de Valencia VLC/Campus (PMIA-2013) for the mobility Grant.