Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Biomechanically-driven simulations of the MyoRing treatment in subjects with high myopia

  • Ariza-Gracia, M.A.
  • Flecha-Lescun, J.
  • Calzada, B.C.
  • Buchler, P.
Purpose: Corneal biomechanics is a determinant factor for the outcome of continuous intracorneal segments (MyoRing, Dioptex GmbH). However, implant selection remains driven by optical parameters such as the average central curvature of the cornea (Kmean) and the Spherical Equivalent (SE), while failing to account for the tissue biomechanics or the intraocular pressure (IOP). We hypothesize that biomechanical models and computer simulation can improve the refractive outcomes of the MyoRing treatment. Methods: Four thousand computer models representing the population of patients who are candidates for a MyoRing treatment have been created using the finite element method. These numerical models accounted for physiologic variability of the anatomical features (anterior and posterior corneal radius of curvature, corneal thickness, axial length and pupil size) and mechanical properties (corneal biomechanics and IOP). Two MyoRing implants were evaluated on these virtual patients (Myoring size: 280 µm; optical zone: 5 and 6 mm; depth: 60%-75%; laser ablated pocket 5 µm). Refractive outcomes obtained with the biomechanical simulation were compared to previous clinical data (Daxer 2017; Rattan 2018). Results: Population-based simulations were able to reproduce the refractive correction observed clinically; the average post-surgical Kmean was within ± 0.5 D of the data reported by Rattan (Fig.1 a), and the distribution of post-surgical SE closely matched the clinical data from Daxer (Fig.1 b). Moreover, our simulation approach allowed us to determine the clinical parameters having the most important contributions to the refractive outcome. For example, we found that the correction in Kmean is strongly related to the pre-surgical thickness, mechanics, and IOP, while the correction in SE is highly affected by the depth of MyoRing insertion. Conclusions: Biomechanical modelling is able to predict the refractive outcomes of MyoRing implantations. This approach provides a deeper understanding on the mechanisms underlying continuous intracorneal segments, which can be used to improve implant design and further personalize the treatment procedure.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Corneal Biomechanics After Intrastromal Ring Surgery: Optomechanical In Silico Assessment

  • Ariza-Gracia, M.A.
  • Flecha-Lescun, J.
  • Buchler, P.
  • Calvo, B.
Purpose: To provide a biomechanical framework to better understand the postsurgical optomechanical behavior of the cornea after ring implantation. Methods: Calibrated in silico models were used to determine the corneal shape and stresses after ring implantation. After mechanical simulations, geometric ray-tracing was used to determine the change in spherical equivalent. The effect of the surgical procedure, circadian variation of intraocular pressure, or the biomechanical weakening introduced by keratoconus (KC) were evaluated for each intrastromal ring. Results: Models predicted the postsurgical optomechanical response of the cornea at a population level. The localized mechanical effect of the additional intrastromal volume introduced by the implants (size and diameter) drives the postsurgical corneal response. However, central corneal stresses did not increase more than 50%, and thus implants did not strengthen the cornea globally. Because of the biomechanical weakening introduced by laser pocketing, continuous implants in a pocket resulted in higher refractive corrections and in the relaxation of the anterior stroma, which could slow down KC progression. Implants can move within the stroma, acting as a dynamic pivot point that modifies corneal kinematics and flattens the corneal center. Changes in stromal mechanical properties did not impact on refraction for normal or pathological corneas. Conclusions: Implants do not stiffen the cornea but create a local bulkening effect that regularizes the corneal shape by modifying corneal kinematics without canceling corneal motion. Translational Relevance: In silico models can help to understand corneal biomechanics, to plan patient-specific interventions, or to create biomechanically driven nomograms.