Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 52
Encontrada(s) 1 página(s)

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

A data-driven learning method for constitutive modeling: Application to vascular hyperelastic soft tissues

  • González, D.
  • García-González, A.
  • Chinesta, F.
  • Cueto, E.
We address the problem of machine learning of constitutive laws when large experimental deviations are present. This is particularly important in soft living tissue modeling, for instance, where large patient-dependent data is found. We focus on two aspects that complicate the problem, namely, the presence of an important dispersion in the experimental results and the need for a rigorous compliance to thermodynamic settings. To address these difficulties, we propose to use, respectively, Topological Data Analysis techniques and a regression over the so-called General Equation for the Nonequilibrium Reversible-Irreversible Coupling (GENERIC) formalism (M. Grmela and H. Ch. Oettinger, Dynamics and thermodynamics of complex fluids. I. Development of a general formalism. Phys. Rev. E 56, 6620, 1997). This allows us, on one hand, to unveil the true "shape" of the data and, on the other, to guarantee the fulfillment of basic principles such as the conservation of energy and the production of entropy as a consequence of viscous dissipation. Examples are provided over pseudo-experimental and experimental data that demonstrate the feasibility of the proposed approach.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

A computational model for cardiomyocytes mechano-electric stimulation to enhance cardiac tissue regeneration

  • Urdeitx, P.
  • Doweidar, M.H.
Electrical and mechanical stimulations play a key role in cell biological processes, being essential in processes such as cardiac cell maturation, proliferation, migration, alignment, attachment, and organization of the contractile machinery. However, the mechanisms that trigger these processes are still elusive. The coupling of mechanical and electrical stimuli makes it difficult to abstract conclusions. In this sense, computational models can establish parametric assays with a low economic and time cost to determine the optimal conditions of in-vitro experiments. Here, a computational model has been developed, using the finite element method, to study cardiac cell maturation, proliferation, migration, alignment, and organization in 3D matrices, under mechano-electric stimulation. Different types of electric fields (continuous, pulsating, and alternating) in an intensity range of 50–350 Vm−1, and extracellular matrix with stiffnesses in the range of 10–40 kPa, are studied. In these experiments, the group’s morphology and cell orientation are compared to define the best conditions for cell culture. The obtained results are qualitatively consistent with the bibliography. The electric field orientates the cells and stimulates the formation of elongated groups. Group lengthening is observed when applying higher electric fields in lower stiffness extracellular matrix. Groups with higher aspect ratios can be obtained by electrical stimulation, with better results for alternating electric fields.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Corneal Biomechanics After Intrastromal Ring Surgery: Optomechanical In Silico Assessment

  • Ariza-Gracia, M.A.
  • Flecha-Lescun, J.
  • Buchler, P.
  • Calvo, B.
Purpose: To provide a biomechanical framework to better understand the postsurgical optomechanical behavior of the cornea after ring implantation. Methods: Calibrated in silico models were used to determine the corneal shape and stresses after ring implantation. After mechanical simulations, geometric ray-tracing was used to determine the change in spherical equivalent. The effect of the surgical procedure, circadian variation of intraocular pressure, or the biomechanical weakening introduced by keratoconus (KC) were evaluated for each intrastromal ring. Results: Models predicted the postsurgical optomechanical response of the cornea at a population level. The localized mechanical effect of the additional intrastromal volume introduced by the implants (size and diameter) drives the postsurgical corneal response. However, central corneal stresses did not increase more than 50%, and thus implants did not strengthen the cornea globally. Because of the biomechanical weakening introduced by laser pocketing, continuous implants in a pocket resulted in higher refractive corrections and in the relaxation of the anterior stroma, which could slow down KC progression. Implants can move within the stroma, acting as a dynamic pivot point that modifies corneal kinematics and flattens the corneal center. Changes in stromal mechanical properties did not impact on refraction for normal or pathological corneas. Conclusions: Implants do not stiffen the cornea but create a local bulkening effect that regularizes the corneal shape by modifying corneal kinematics without canceling corneal motion. Translational Relevance: In silico models can help to understand corneal biomechanics, to plan patient-specific interventions, or to create biomechanically driven nomograms.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Enhanced piezoelectric fibered extracellular matrix to promote cardiomyocyte maturation and tissue formation: a 3d computational model

  • Urdeitx, P.
  • Doweidar, M.H.
Mechanical and electrical stimuli play a key role in tissue formation, guiding cell processes such as cell migration, differentiation, maturation, and apoptosis. Monitoring and controlling these stimuli on in vitro experiments is not straightforward due to the coupling of these different stimuli. In addition, active and reciprocal cell–cell and cell–extracellular matrix interactions are essential to be considered during formation of complex tissue such as myocardial tissue. In this sense, computational models can offer new perspectives and key information on the cell microenvironment. Thus, we present a new computational 3D model, based on the Finite Element Method, where a complex extracellular matrix with piezoelectric properties interacts with cardiac muscle cells during the first steps of tissue formation. This model includes collective behavior and cell processes such as cell migration, maturation, differentiation, proliferation, and apoptosis. The model has employed to study the initial stages of in vitro cardiac aggregate formation, considering cell–cell junctions, under different extracellular matrix configurations. Three different cases have been purposed to evaluate cell behavior in fibered, mechanically stimulated fibered, and mechanically stimulated piezoelectric fibered extra-cellular matrix. In this last case, the cells are guided by the coupling of mechanical and electrical stimuli. Accordingly, the obtained results show the formation of more elongated groups and enhancement in cell proliferation.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Mechanical stimulation of cell microenvironment for cardiac muscle tissue regeneration: a 3D in-silico model

  • Urdeitx, P.
  • Doweidar, M.H.
The processes in which cardiac cells are reorganized for tissue regeneration is still unclear. It is a complicated process that is orchestrated by many factors such as mechanical, chemical, thermal, and/or electrical cues. Studying and optimizing these conditions in-vitro is complicated and time costly. In such cases, in-silico numerical simulations can offer a reliable solution to predict and optimize the considered conditions for the cell culture process. For this aim, a 3D novel and enhanced numerical model has been developed to study the effect of the mechanical properties of the extracellular matrix (ECM) as well as the applied external forces in the process of the cell differentiation and proliferation for cardiac muscle tissue regeneration. The model has into account the essential cellular processes such as migration, cell–cell interaction, cell–ECM interaction, differentiation, proliferation and/or apoptosis. It has employed to study the initial stages of cardiac muscle tissue formation within a wide range of ECM stiffness (8–50 kPa). The results show that, after cell culture within a free surface ECM, cells tend to form elongated aggregations in the ECM center. The formation rate, as well as the aggregation morphology, have been found to be a function of the ECM stiffness and the applied external force. Besides, it has been found that the optimum ECM stiffness for cardiovascular tissue regeneration is in the range of 29–39 kPa, combined with the application of a mechanical stimulus equivalent to deformations of 20–25%.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Structure-preserving neural networks

  • Hernández Laín, Quercus
  • Badías Herbera, Alberto
  • González Ibáñez, David
  • Chinesta Soria, Francisco
  • Cueto Prendes, Elías
We develop a method to learn physical systems from data that employs feedforward neural networks and whose predictions comply with the first and second principles of thermodynamics. The method employs a minimum amount of data by enforcing the metriplectic structure of dissipative Hamiltonian systems in the form of the so-called General Equation for the Non-Equilibrium Reversible-Irreversible Coupling, GENERIC (Öttinger and Grmela (1997) [36]). The method does not need to enforce any kind of balance equation, and thus no previous knowledge on the nature of the system is needed. Conservation of energy and dissipation of entropy in the prediction of previously unseen situations arise as a natural by-product of the structure of the method. Examples of the performance of the method are shown that comprise conservative as well as dissipative systems, discrete as well as continuous ones.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Learning non-Markovian physics from data

  • González, D.
  • Chinesta, F.
  • Cueto, E.
We present a method for the data-driven learning of physical phenomena whose evolution in time depends on history terms. It is well known that a Mori-Zwanzig-type projection produces a description of the physical phenomena that depends on history, and also incorporates noise. If the data stream is sampled from the projected Mori-Zwanzig manifold, the description of the phenomenon will always depend on one or more unresolved variables, a priori unknown, and will also incorporate noise. The present work introduces a novel technique able to unveil the presence of such internal variables—although without giving it a precise physical meaning—and to minimize the inherent noise. The method is based upon a refinement of the scale at which the phenomenon is described by means of kernel-PCA techniques. By learning the metriplectic form of the evolution of the physics, the resulting approximation satisfies basic thermodynamic principles such as energy conservation and positive entropy production. Examples are provided that show the potential of the method in both discrete and continuum mechanics.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Effect of haptic geometry in C-loop intraocular lenses on optical quality

  • Cabeza-Gil, I.
  • Pérez-Gracia, J.
  • Remón, L.
  • Calvo, B.
The biomechanical stability of intraocular lenses (IOLs) must achieve high-quality optical performance and clinical outcomes after cataract surgery. For this reason, the quality and performance features of the IOLs should be previously analysed following the Standard ISO 11979-2 and ISO 11979-3. The ISO 11979-3 tries to reproduce the behaviour of the IOL in the capsular bag by compressing the lens between two clamps. With this test, it has been demonstrated that the haptic design is a crucial factor to obtain biomechanical stability. Hence, the main goal of this study was to design an aberration-free aspheric IOL and to study the influence of haptic geometry on the optical quality. For that purpose, 5 hydrophobic IOLs with different haptic design were manufactured and their biomechanical stability was compared experimentally and numerically. The IOLs were classified as stiff and flexible designs depending on their haptic geometry. The biomechanical response was measured by means of the compression force, the axial displacement, the angle of contact or contact area, the decentration, the tilt and the strain energy. The results suggest that in vitro and in silico compression tests present similar responses for the IOLs analysed. Furthermore, the flexible IOL designs presented better biomechanical stability than stiff designs. These results were correlated with the optical performance, where the optical quality decreases with worst biomechanical stability. This numerical methodology provides an indisputable advance regarding IOL designs, leading to reduce costs by exploring a feasible space of solutions during the product design process and prior to manufacturing.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Experimental evaluation of the injection force exerted in intraocular lens delivery with syringe-type injectors

  • Cabeza-Gil, I.
  • Ríos-Ruiz, I.
  • Calvo, B.
The process of intraocular lens (IOL) delivery within the capsular bag during cataract surgery is crucial, as the integrity of the IOL, the injector and the ocular structures should be preserved at all times. This study aims to obtain the main parameters that affect the injection force exerted in the ejection of an intraocular lens (IOL) through syringe-type injectors. For that purpose, ejection tests were carried out in vitro, measuring the resistance force throughout the entire delivery process. The effect of IOL material, haptic design, IOL thickest area and ophthalmic viscosurgical device (OVD) was studied by ejecting seven IOLs with four syringe-type injectors of different sizes, 3.0, 2.2 and 1.8 mm. In all injectors, plate hydrophilic IOLs present the lowest resistance forces; hydrated C-loop hydrophobic IOLs present higher forces and the C-loop hydrophobic IOL in dry conditions presents the highest resistance forces. All IOLs could be properly delivered with an injector size of 2.2 mm, making injector sizes of 3.0 mm outdated. The injector size of 1.8 mm damaged several IOLs. IOL material and cartridge nozzle size were the most influential parameters in IOL delivery. IOL thickest area was also relevant but in a lesser extent whereas IOL haptic design was not as relevant.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

A numerical investigation of changes in lens shape during accommodation

  • Cabeza-Gil, I.
  • Grasa, J.
  • Calvo, B.
The purpose of this study was to investigate how the mechanical properties and geometry of the lens influence the changes in lens shape during accommodation. To do so, ex vivo stretching tests of the isolated lens were simulated via finite element analysis. In these tests, the lens is stretched from the accommodated state to the non-accommodated state. Several key characteristics of the lens were studied: the stiffness gradient of the lens material, the distribution of the capsule thickness, the mechanical properties of the capsule and the material comprising the lens, nucleus and cortex, and the influence of two different age-related lens geometries (17 and 29 y/o subjects). To determine the effects on the changes in lens shape during accommodation, changes in the anterior and posterior radius, the lens and nucleus thicknesses and the equatorial lens diameter were analysed. The results suggest that multiple factors exert statistically significant influences on how the lens changes its shape, but two factors predominate over the rest: the stiffness ratio between the nucleus and cortex and the stiffness of the capsule, specifically the posterior surface.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Simulating Extraocular Muscle Dynamics. A Comparison between Dynamic Implicit and Explicit Finite Element Methods

  • Grasa, Jorge
  • Calvo, Begoña
The finite element method has been widely used to investigate the mechanical behavior of biological tissues. When analyzing these particular materials subjected to dynamic requests, time integration algorithms should be considered to incorporate the inertial effects. These algorithms can be classified as implicit or explicit. Although both algorithms have been used in different scenarios, a comparative study of the outcomes of both methods is important to determine the performance of a model used to simulate the active contraction of the skeletal muscle tissue. In this work, dynamic implicit and dynamic explicit solutions are presented for the movement of the eye ball induced by the extraocular muscles. Aspects such as stability, computational time and the influence of mass-scaling for the explicit formulation were assessed using ABAQUS software. Both strategies produced similar results regarding range of movement of the eye ball, total deformation and kinetic energy. Using the implicit dynamic formulation, an important amount of computational time reduction is achieved. Although mass-scaling can reduce the simulation time, the dynamic contraction of the muscle is drastically altered.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Development and validation of a computational model for steak double-sided pan cooking

  • Moya, J.
  • Lorente-Bailo, S.
  • Salvador, M.L.
  • Ferrer-Mairal, A.
  • Martínez, M.A.
  • Calvo, B.
  • Grasa, J.
The objective of this study was to develop and validate a numerical model to adequately simulate the double-sided pan cooking of beef in a domestic environment. The proposed model takes into account the heat flow from the pan to the meat and the moisture transfer, simultaneously with the meat deformation. The model considers the swelling pressure gradient caused by the shrinkage of the meat fibers and connective tissue due to the denaturation of proteins and the loss of the water holding capacity during cooking. The model results were successfully verified with experimental data of the central temperature and weight loss recorded during cooking for three degrees of doneness. The measured experimental temperatures at the center of the meat were 30 ± 3 °C (very rare), 44 ± 3 °C (rare) and 57 ± 2 °C (done) for a 19 mm steak thickness. Meanwhile, their water losses were 4 ± 2 %, 8 ± 1 % and 11 ± 2 %, respectively. The root mean squared errors of the model predictions were 2.16 °C (very rare), 3.56 °C (rare) and 4.57 °C (done) for the central temperature and 1.48 %, 2.08 % and 2.40 %, respectively for the water loss. The model also correctly predicts cooking times for steaks of different thicknesses, taking weight loss as a reference to set this time. The proposed model is postulated as a useful cooking assistance tool to estimate the optimal cooking time according to consumer preferences.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Mechanical characterisation of hydrophobic and hydrophilic acrylates used in intraocular lenses through depth sensing indentation

  • Cabeza-Gil, I.
  • Calvo, B.
  • Rico, A.
  • Reinhards-Hervás, C.
  • Rodríguez, J.
In this work, the mechanical behaviour of hydrophilic and hydrophobic acrylates has been characterised by depth sensing indentation. Time-dependent behaviour has been studied using load-relaxation tests. Experiments have been simulated with a finite element software using a visco-hyperelastic material model. The parameters of this model have been determined using deep learning techniques. The developed material models have been used to mechanically simulate a standard compression test of a prototype intraocular lens.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Effect of decentration, tilt and rotation on the optical quality of various toric intraocular lens designs: a numerical and experimental study

  • Pérez-Gracia, Jesús
  • Ares, Jorge
  • Ávila Gómez, Francisco Javier
  • Remón, Laura
Toric intraocular lenses (T-IOLs) may lose their optical quality if they are not correctly positioned inside the capsular bag once implanted. In this work, T-IOLs with cylinder powers of +1.50, +4.50 and +7.50 D and differing degrees of spherical aberration have been designed, manufactured and tested in vitro using a commercial optical bench that complies with the requirements of standard ISO 11979-2. Moreover, the effect of tilt and rotation on optical quality was assessed by means of numerical ray tracing on an astigmatic eye model, while the effect of decentration was evaluated numerically and experimentally.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Design and experimental validation of a magnetic device for stem cell culture

  • Salvador-Clavell, R.
  • Rodríguez-Fortún, J.M.
  • López, I.
  • Martín De Llano, J.J.
  • Orús, J.
  • Sancho-Tello, M.
  • Carda, C.
  • Hamdy Doweidar, M.
Cell culture of bone and tendon tissues requires mechanical stimulation of the cells in order to mimic their physiological state. In the present work, a device has been conceived and developed to generate a controlled magnetic field with a homogeneous gradient in the working space. The design requirement was to maximize the magnetic flux gradient, assuring a minimum magnetizing value in a 15 mm × 15 mm working area, which highly increases the normal operating range of this sort of devices. The objective is to use the machine for two types of biological tests: magnetic irradiation of biological samples and force generation on paramagnetic particles embedded in scaffolds for cell culture. The device has been manufactured and experimentally validated by evaluating the force exerted on magnetic particles in a viscous fluid. Apart from the magnetic validation, the device has been tested for irradiating biological samples. In this case, viability of human dental pulp stem cells has been studied in vitro after electromagnetic field exposition using the designed device. After three days of irradiation treatment, cellular microtissues showed a 59% increase in the viable cell number. Irradiated cells did not show morphological differences when compared with control cells.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

A Combined Experimental-Numerical Investigation of the Thermal Efficiency of the Vessel in Domestic Induction Systems

  • Bonet-Sanchez, Belen
  • Cabeza-Gil, Iulen
  • Calvo, Begona
  • Grasa, Jorge
  • Franco, Carlos
  • Llorente, Sergio
  • Martinez, Miguel A.
New studies are emerging to reduce energy costs and become a more sustainable society. One of the processes where the greatest savings can be made is in cooking, due to its large-scale global use. In this vein, this study aims to analyse the influence of the vessel in the thermal efficiency at the cooking process. For that purpose, a numerical model of a cooking vessel was designed and validated with three different experimental heating tests. One of the key factors of the process is the contact between the vessel and the glass, therefore, two new approaches to model the thermal contact between the vessel and the cooktop were explored. Once the numerical models were calibrated, a full factorial analysis was performed to quantify the influence of the key parameters of the vessel in the heating process during cooking (thermal conductivity, specific heat, convection and radiation coefficients, and vessel concavity). Two of the most influential parameters in the heating process are the conductivity and the thermal contact between the vessel and the glass. Higher cooking efficiency can be achieved both with a low thermal conductivity vessel and with a high concavity, i.e., increasing the isolation between the vessel and the glass.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Muscular and tendon degeneration after achilles rupture: new insights into future repair strategies

  • Gil-Melgosa, Lara
  • Grasa, Jorge
  • Urbiola, Ainhoa
  • Llombart, Rafael
  • Susaeta Ruiz, Miguel
  • Montiel, Veronica
  • Ederra, Cristina
  • Calvo, Begona
  • Ariz, Mikel
  • Ripalda-Cemborain, Purificacion
  • Prosper, Felipe
  • Ortiz-de-Solorzano, Carlos
  • Pons-Villanueva, Juan
  • Perez Ruiz, Ana
Achilles tendon rupture is a frequent injury with an increasing incidence. After clinical surgical repair, aimed at suturing the tendon stumps back into their original position, the repaired Achilles tendon is often plastically deformed and mechanically less strong than the pre-injured tissue, with muscle fatty degeneration contributing to function loss. Despite clinical outcomes, pre-clinical research has mainly focused on tendon structural repair, with a lack of knowledge regarding injury progression from tendon to muscle and its consequences on muscle degenerative/regenerative processes and function. Here, we characterize the morphological changes in the tendon, the myotendinous junction and muscle belly in a mouse model of Achilles tendon complete rupture, finding cellular and fatty infiltration, fibrotic tissue accumulation, muscle stem cell decline and collagen fiber disorganization. We use novel imaging technologies to accurately relate structural alterations in tendon fibers to pathological changes, which further explain the loss of muscle mechanical function after tendon rupture. The treatment of tendon injuries remains a challenge for orthopedics. Thus, the main goal of this study is to bridge the gap between clinicians'' knowledge and research to address the underlying pathophysiology of ruptured Achilles tendon and its consequences in the gastrocnemius. Such studies are necessary if current practices in regenerative medicine for Achilles tendon ruptures are to be improved.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Color changes in beef meat during pan cooking: kinetics, modeling and application to predict turn over time

  • Moya, Jara
  • Lorente-Bailo, Silvia
  • Ferrer-Mairal, Ana
  • Martínez, Miguel A.
  • Calvo, Begoña
  • Grasa, Jorge
  • Salvador, María L.
The kinetics of heat-induced color changes in beef meat was determined and implemented in a numerical model for doublesided pan cooking of steak. The CIELab color space was used to obtain the lightness (coordinate L∗ ) and the reddish tone (coordinate a∗ ) of the cooked meat. L∗ was the CIELab coordinate that contributed the most to the change in the absolute color. Two response surfaces were found to describe the evolution with time and temperature of both color coordinates, L∗ and a∗ . The model results were successfully verified with experimental data of the two coordinates along the thickness of the meat for three degrees of cooking. The Root-Mean-Squared Errors (RMSE) for coordinate L∗ were 5.17 (very rare), 2.02 (medium rare) and 3.83 (done), and for coordinate a∗ 1.44 (very rare), 1.26 (medium rare) and 0.89 (done). The applicability of the model for practical cooking purposes was illustrated by determining the optimum turn over time to achieve a similar color profile on both sides of the meat. The turn over time depended on the desired degrees of cooking, and were comprised between one-half and two-thirds of the final cooking time, increasing from very rare cooking degree to done cooking degree.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Atherosclerotic Plaque Segmentation Based on Strain Gradients: A Theoretical Framework

  • Latorre, Álvaro T.
  • Martínez, Miguel A.
  • Cilla, Myriam
  • Ohayon, Jacques
  • Peña, Estefanía
Background: Atherosclerotic plaque detection is a clinical and technological problem that has been approached by different studies. Nowadays, intravascular ultrasound (IVUS) is the standard used to capture images of the coronary walls and to detect plaques. However, IVUS images are difficult to segment, which complicates obtaining geometric measurements of the plaque. Objective: IVUS, in combination with new techniques, allows estimation of strains in the coronary section. In this study, we have proposed the use of estimated strains to develop a methodology for plaque segmentation. Methods: The process is based on the representation of strain gradients and the combination of the Watershed and Gradient Vector Flow algorithms. Since it is a theoretical framework, the methodology was tested with idealized and real IVUS geometries. Results: We achieved measurements of the lipid area and fibrous cap thickness, which are essential clinical information, with promising results. The success of the segmentation depends on the plaque geometry and the strain gradient variable (SGV) that was selected. However, there are some SGV combinations that yield good results regardless of plaque geometry such as ▽εvMises+▽εrθ, ▽εyy+▽εrr or ▽εmin+▽εTresca. These combinations of SGVs achieve good segmentations, with an accuracy between 97.10% and 94.39% in the best pairs. Conclusions: The new methodology provides fast segmentation from different strain variables, without an optimization step.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

A detailed methodology to model the Non Contact Tonometry: a Fluid Structure Interaction study

  • Redaelli, Elena
  • Grasa, Jorge
  • Calvo, Begoña
  • Rodriguez Matas, Jose Felix
  • Luraghi, Giulia
Understanding the corneal mechanical properties has great importance in the study of corneal pathologies and the prediction of refractive surgery outcomes. Non-Contact Tonometry (NCT) is a non-invasive diagnostic tool intended to characterize the corneal tissue response in vivo by applying a defined air-pulse. The biomarkers inferred from this test can only be considered as indicators of the global biomechanical behaviour rather than the intrinsic biomechanical properties of the corneal tissue. A possibility to isolate the mechanical response of the corneal tissue is the use of an inverse finite element method, which is based on accurate and reliable modelling. Since a detailed methodology is still missing in the literature, this paper aims to construct a high-fidelity finite-element model of an idealized 3D eye for in silico NCT. A fluid-structure interaction (FSI) simulation is developed to virtually apply a defined air-pulse to a 3D idealized eye model comprising cornea, limbus, sclera, lens and humors. Then, a sensitivity analysis is performed to examine the influence of the intraocular pressure (IOP) and the structural material parameters on three biomarkers associated with corneal deformation. The analysis reveals the requirements for the in silico study linked to the correct reproduction of three main aspects: the air pressure over the cornea, the biomechanical properties of the tissues, and the IOP. The adoption of an FSI simulation is crucial to capture the correct air pressure profile over the cornea as a consequence of the air-jet. Regarding the parts of the eye, an anisotropic material should be used for the cornea. An important component is the sclera: the stiffer the sclera, the lower the corneal deformation due to the air-puff. Finally, the fluid-like behavior of the humors should be considered in order to account for the correct variation of the IOP during the test which will, otherwise, remain constant. The development of a strong FSI tool amenable to model coupled structures and fluids provides the basis to find the biomechanical properties of the corneal tissue in vivo.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Is location a significant parameter in the layer dependent dissection properties of the aorta?

  • Ríos-Ruiz, Itziar
  • Martínez, Miguel Ángel
  • Peña, Estefanía
Proper characterisation of biological tissue is key to understanding the effect of the biomechanical environment in the physiology and pathology of the cardiovascular system. Aortic dissection in particular is a prevalent and sometimes fatal disease that still lacks a complete comprehension of its progression. Its development and outcome, however, depend on the location in the vessel. Dissection properties of arteries are frequently studied via delamination tests, such as the T-peel test and the mixed-mode peel test. So far, a study that performs both tests throughout different locations of the aorta, as well as dissecting several interfaces, is missing. This makes it difficult to extract conclusions in terms of vessel heterogeneity, as a standardised experimental procedure cannot be assured for different studies in literature. Therefore, both dissection tests have been here performed on healthy porcine aortas, dissecting three interfaces of the vessels, i.e., the intima-media, the media-adventitia and the media within itself, considering different locations of the aorta, the ascending thoracic aorta (ATA), the descending thoracic aorta and the infrarenal abdominal aorta (IAA). Significant differences were found for both, layers and location. In particular, dissection forces in the ATA were the highest and the separation of the intima-media interface required significantly the lowest force. Moreover, dissection in the longitudinal direction of the vessel generally required more force than in the circumferential one. These results emphasise the need to characterise aortic tissue considering the specific location and dissected layer of the vessel.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Modeling systems from partial observations

  • Champaney, Victor
  • Amores, Víctor J.
  • Garois, Sevan
  • Irastorza-Valera, Luis
  • Ghnatios, Chady
  • Montáns, Francisco J.
  • Cueto, Elías
  • Chinesta, Francisco
Modeling systems from collected data faces two main difficulties: the first one concerns the choice of measurable variables that will define the learnt model features, which should be the ones concerned by the addressed physics, optimally neither more nor less than the essential ones. The second one is linked to accessibility to data since, generally, only limited parts of the system are accessible to perform measurements. This work revisits some aspects related to the observation, description, and modeling of systems that are only partially accessible and shows that a model can be defined when the loading in unresolved degrees of freedom remains unaltered in the different experiments.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Computational modeling of multiple myeloma interactions with resident bone marrow cells

  • Urdeitx, Pau
  • Mousavi, S. Jamaleddin
  • Avril, Stephane
  • Doweidar, Mohamed H.
The interaction of multiple myeloma with bone marrow resident cells plays a key role in tumor progression and the development of drug resistance. The tumor cell response involves contact-mediated and paracrine interactions. The heterogeneity of myeloma cells and bone marrow cells makes it difficult to reproduce this environment in in-vitro experiments. The use of in-silico established tools can help to understand these complex problems. In this article, we present a computational model based on the finite element method to define the interactions of multiple myeloma cells with resident bone marrow cells. This model includes cell migration, which is controlled by stress–strain equilibrium, and cell processes such as proliferation, differentiation, and apoptosis. A series of computational experiments were performed to validate the proposed model. Cell proliferation by the growth factor IGF-1 is studied for different concentrations ranging from 0–10 ng/mL. Cell motility is studied for different concentrations of VEGF and fibronectin in the range of 0–100 ng/mL. Finally, cells were simulated under a combination of IGF-1 and VEGF stimuli whose concentrations are considered to be dependent on the cancer-associated fibroblasts in the extracellular matrix. Results show a good agreement with previous in-vitro results. Multiple myeloma growth and migration are shown to correlate linearly to the IGF-1 stimuli. These stimuli are coupled with the mechanical environment, which also improves cell growth. Moreover, cell migration depends on the fiber and VEGF concentration in the extracellular matrix. Finally, our computational model shows myeloma cells trigger mesenchymal stem cells to differentiate into cancer-associated fibroblasts, in a dose-dependent manner.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Peripheral Refraction of Two Myopia Control Contact Lens Models in a Young Myopic Population

  • Marcellán, Maria Concepción
  • Ávila, Francisco J.
  • Ares, Jorge
  • Remón, Laura
Peripheral refraction can lead to the development of myopia. The aim of this study was to compare relative peripheral refraction (RPR) in the same cohort of uncorrected (WCL) and corrected eyes with two different soft contact lenses (CL) designed for myopia control, and to analyze RPR depending on the patient’s refraction. A total of 228 myopic eyes (114 healthy adult subjects) (−0.25 D to −10.00 D) were included. Open-field autorefraction was used to measure on- and off- axis refractions when uncorrected and corrected with the two CLs (dual focus (DF) and extended depth of focus (EDOF)). The RPR was measured every 10° out to 30° in a temporal-nasal orientation and analyzed as a component of the power vector (M). The average RPR for all subjects was hyperopic when WCL and when corrected with EDOF CL design, but changed to a myopic RPR when corrected with DF design. Significant differences were found between RPR curves with both CLs in all the eccentricities (Bonferroni correction p < 0.008, except 10°N). An incremental relationship between relative peripheral refraction at 30 degrees and myopia level was found. It is concluded that the two CLs work differently at the periphery in order to achieve myopia control.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Understanding the Parameter Influence on Lesion Growth for a Mechanobiology Model of Atherosclerosis

  • Hernández-López, Patricia
  • Martínez, Miguel A.
  • Peña, Estefanía
  • Cilla, Myriam
In this work, we analyse the influence of the parameters of a mathematical model, previously proposed by the authors, for reproducing atheroma plaque in arteries. The model uses Navier–Stokes equations to calculate the blood flow along the lumen in a transient mode. It also uses Darcy’s law, Kedem–Katchalsky equations, and the three-pore model to simulate plasma and substance flows across the endothelium. The behaviours of all substances in the arterial wall are modelled with convection–diffusion–reaction equations, and finally, plaque growth is calculated. We consider a 2D geometry of a carotid artery, but the model can be extrapolated to other geometries or arteries, such as the coronaries or the aorta. A mono-variant sensitivity analysis of the model parameters was performed, with values of ±25% and ±10%, with respect to the values of the previous model. The results were analysed with respect to the volume in the plaque of foam cells (FC), synthetic smooth muscle cells (SSMC), and collagen fibre. It was observed that the volume in the plaque of the different substances (FC, SSMC, and collagen) has a strong influence on the results, so it could be used to analyse the vulnerability of plaque. The stenosis ratio of the plaque was also analysed, showing a strong influence on the results as well. Parameters that influence all the results considered when ranged ±10% are the rate of LDL degradation and the diffusion coefficients of LDL and monocytes in the arterial wall. Furthermore, it was observed that the change in the volume of foam cells in the plaque has a greater influence on the stenosis ratio than the change of synthetic smooth muscle cells or collagen fibre.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

A thermodynamics-informed active learning approach to perception and reasoning about fluids

  • Moya, Beatriz
  • Badías, Alberto
  • González, David
  • Chinesta, Francisco
  • Cueto, Elías
Learning and reasoning about physical phenomena is still a challenge in robotics development, and computational sciences play a capital role in the search for accurate methods able to provide explanations for past events and rigorous forecasts of future situations. We propose a thermodynamics-informed active learning strategy for fluid perception and reasoning from observations. As a model problem, we take the sloshing phenomena of different fluids contained in a glass. Starting from full-field and high-resolution synthetic data for a particular fluid, we develop a method for the tracking (perception) and simulation (reasoning) of any previously unseen liquid whose free surface is observed with a commodity camera. This approach demonstrates the importance of physics and knowledge not only in data-driven (gray-box) modeling but also in real-physics adaptation in low-data regimes and partial observations of the dynamics. The presented method is extensible to other domains such as the development of cognitive digital twins able to learn from observation of phenomena for which they have not been trained explicitly.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Multiple myeloma cell simulation using an agent-based framework coupled with a continuous fluid model

  • Urdeitx, Pau
  • Clara-Trujillo, Sandra
  • Gomez Ribelles, Jose Luis
  • Doweidar, Mohamed H.
Bone marrow mechanical conditions play a key role in multiple myeloma cancer. The complex mechanical and chemical conditions, as well as the interactions with other resident cells, hinder the development of effective treatments. Agent-based computational models, capable of defining the specific conditions for every single cell, can be a useful tool to identify the specific tumor microenvironment. In this sense, we have developed a novel hybrid 3D agent-based model with coupled fluid and particle dynamics to study multiple myeloma cells’ growth. The model, which considers cell–cell interactions, cell maturation, and cell proliferation, has been implemented by employing user-defined functions in the commercial software Fluent. To validate and calibrate the model, cell sedimentation velocity and cell proliferation rates have been compared with in vitro results, as well as with another previously in-house developed model. The results show that cell proliferation increased as cell–cell, and cell–extracellular matrix interactions increased, as a result of the reduction n maturation time. Cells in contact form cell aggregates, increasing cell–cell interactions and thus cell proliferation. Saturation in cell proliferation was observed when cell aggregates increased in size and the lack of space inhibited internal cells’ proliferation. Compared with the previous model, a huge reduction in computational costs was obtained, allowing for an increase in the number of simulated cells.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Regularized regressions for parametric models based on separated representations

  • Sancarlos, Abel
  • Champaney, Víctor
  • Cueto, Elías
  • Chinesta, Francisco
Regressions created from experimental or simulated data enable the construction of metamodels, widely used in a variety of engineering applications. Many engineering problems involve multi-parametric physics whose corresponding multi-parametric solutions can be viewed as a sort of computational vademecum that, once computed offline, can be then used in a variety of real-time engineering applications including optimization, inverse analysis, uncertainty propagation or simulation based control. Sometimes, these multi-parametric problems can be solved by using advanced model order reduction—MOR-techniques. However, solving these multi-parametric problems can be very costly. In that case, one possibility consists in solving the problem for a sample of the parametric values and creating a regression from all the computed solutions. The solution for any choice of the parameters is then inferred from the prediction of the regression model. However, addressing high-dimensionality at the low data limit, ensuring accuracy and avoiding overfitting constitutes a difficult challenge. The present paper aims at proposing and discussing different advanced regressions based on the proper generalized decomposition (PGD) enabling the just referred features. In particular, new PGD strategies are developed adding different regularizations to the s-PGD method. In addition, the ANOVA-based PGD is proposed to ally them.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Optimal velocity planning based on the solution of the Euler-Lagrange equations with a neural network based velocity regression

  • Ghnatios, Chady
  • di Lorenzo, Daniele
  • Champaney, Víctor
  • Cueto, Elías
  • Chinesta, Francisco
Trajectory optimization is a complex process that includes an infinite number of possibilities and combinations. This work focuses on a particular aspect of the trajectory optimization, related to the optimization of a velocity along a predefined path, with the aim of minimizing power consumption. To tackle the problem, a functional formulation and minimization strategy is developed, by means of the Euler-Lagrange equation. The minimization is later performed using a neural network approach. The strategy is deemed Lagrange-Net, as it is based on the minimization of the energy functional, by the means of Lagrange's equation and neural network approximations.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Reseña (Review)

Thermodynamics of Learning Physical Phenomena

  • Cueto, Elias
  • Chinesta, Francisco
Thermodynamics could be seen as an expression of physics at a high epistemic level. As such, its potential as an inductive bias to help machine learning procedures attain accurate and credible predictions has been recently realized in many fields. We review how thermodynamics provides helpful insights in the learning process. At the same time, we study the influence of aspects such as the scale at which a given phenomenon is to be described, the choice of relevant variables for this description or the different techniques available for the learning process.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Conciliating accuracy and efficiency to empower engineering based on performance: a short journey

  • Chinesta, Francisco
  • Cueto, Elias
This paper revisits the different arts of engineering. The art of modeling for describing the behavior of complex systems from the solution of partial differential equations that are expected to govern their responses. Then, the art of simulation concerns the ability of solving these complex mathematical objects expected to describe the physical reality as accurately as possible (accuracy with respect to the exact solution of the models) and as fast as possible. Finally, the art of decision making needs to ensure accurate and fast predictions for efficient diagnosis and prognosis. For that purpose physics-informed digital twins (also known as Hybrid Twins) will be employed, allying real-time physics (where complex models are solved by using advanced model order reduction techniques) and physics-informed data-driven models for filling the gap between the reality and the physics-based model predictions. The use of physics-aware data-driven models in tandem with physics-based reduced order models allows us to predict very fast without compromising accuracy. This is compulsory for diagnosis and prognosis purposes.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Unraveling the multilayer mechanical response of aorta using layer-specific residual stresses and experimental properties

  • Díaz, C.
  • Peña, J. A.
  • Martínez, M. A.
  • Peña, E.
To test the capability of the multilayer model, we used previously published layer-specific experimental data relating to the axial pre-stretch, the opening angle, the fiber distribution obtained by polarized light microscopy measurements, and the uniaxial and biaxial response of the porcine descending and abdominal aorta. We fitted the mechanical behavior of each arterial layer using Gasser, Holzapfel and Ogden strain energy function using the dispersion parameter ¿ as phenomenological parameter obtained during the fitting procedure or computed from the experimental fiber distribution. A multilayer finite element model of the whole aorta with the dimensions of the circumferential and longitudinal strips were then built using layer-specific material parameters previously fitted. This model was used to capture the whole aorta response under uniaxial and biaxial stress states and to reproduce the response of the whole aorta to internal pressure. Our results show that a model based on a multilayer structure without residual stresses is unable to render the uniaxial and biaxial mechanical response of the aorta (R2=0.6954 and R2=0.8582 for descending thoracic aorta (DTA) and infrarenal abdominal aorta (IAA), respectively). Only an appropriate multilayer model that includes layer-specific residual stresses can reproduce the response of the whole aorta (R2=0.9787 and R2=0.9636 for DTA and IAA respectively). In addition, a multilayer model without residual stresses produces the same stress distribution as a monolayer model without residual stresses where the maximal value of circumferential and longitudinal stresses appears at the inner radius of the intima. Finally, if layer-specific residual stresses are not available, there is less error the stress distribution using a monolayer model with residual stresses that a multilayer model without residual stresses.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Biomechanical characterization and constitutive modeling of the layer-dissected residual strains and mechanical properties of abdominal porcine aorta

  • Peña, Juan A.
  • Cilla, M.
  • Martínez, Miguel A.
  • Peña, Estefania
We analyze the residual stresses and mechanical properties of layer-dissected infrarenal abdominal aorta (IAA). We measured the axial pre-stretch and opening angle and performed uniaxial tests to study and compare the mechanical behavior of both intact and layer-dissected porcine IAA samples under physiological loads. Finally, some of the most popular anisotropic hyperelastic constitutive models (GOH and microfiber models) were proposed to estimate the mechanical properties of the abdominal aorta by least-square fitting of the recorded in-vitro uniaxial test results. The results show that the residual stresses are layer dependent. In all cases, we found that the OA in the media layer is lower than in the whole artery, the intima and the adventitia. For the axial pre-stretch, we found that the adventitia and the media were slightly stretched in the environment of the intact arterial strip, whereas the intima appears to be compressed. Regarding the mechanical properties, the media seems to be the softest layer over the whole deformation domain showing high anisotropy, while the intima and adventitia exhibit considerable stiffness and a lower anisotropy response. Finally, all the hyperelastic anisotropic models considered in this study provided a reasonable approximation of the experimental data. The GOH model showed the best fitting.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Peripheral refraction under different levels of illuminance

  • Marcellán Vidosa, María Concepción
  • Remón, Laura
  • Ávila, Francisco J.
Peripheral refraction is believed to be involved in the development of myopia. The aim of this study was to compare the relative peripheral refraction (RPR) at four different levels of illuminance, ranging from photopic conditions to complete darkness, using an open‐field autorefraction method. The RPR was calculated for each eccentricity by subtracting central from peripheral autorefraction measurements. The study included 114 myopic eyes from 114 subjects (mean age of 21.81 ± 1.91 years) and the mean difference in RPR between scotopic and photopic conditions (0 and 300 lux, respectively) was +0.32 D at 30° temporal and +0.37 D at 30° in the nasal visual field (NVF). Statistically significant differences were observed between 0 and 300 lux at 30° in the temporal visual field and at 30° and 20° in the NVF. Our results revealed a significant increase in relative peripheral hyperopia with increasing visual field eccentricity along the horizontal visual field in myopic eyes of young adults. Furthermore, this relative peripheral hyperopia increased as illumination decreased. These findings suggest that an increase in peripheral illuminance may protect against myopic eye growth.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Characterizing atherosclerotic tissues: in silico analysis of mechanical properties using intravascular ultrasound and inverse finite element methods

  • Latorre, Álvaro T.
  • Martínez, Miguel A.
  • Peña, Estefanía
Atherosclerosis is a prevalent cause of acute coronary syndromes that consists of lipid deposition inside the artery wall, creating an atherosclerotic plaque. Early detection may prevent the risk of plaque rupture. Nowadays, intravascular ultrasound (IVUS) is the most common medical imaging technology for atherosclerotic plaque detection. It provides an image of the section of the coronary wall and, in combination with new techniques, can estimate the displacement or strain fields. From these magnitudes and by inverse analysis, it is possible to estimate the mechanical properties of the plaque tissues and their stress distribution. In this paper, we presented a methodology based on two approaches to characterize the mechanical properties of atherosclerotic tissues. The first approach estimated the linear behavior under particular pressure. In contrast, the second technique yielded the non-linear hyperelastic material curves for the fibrotic tissues across the complete physiological pressure range. To establish and validate this method, the theoretical framework employed in silico models to simulate atherosclerotic plaques and their IVUS data. We analyzed different materials and real geometries with finite element (FE) models. After the segmentation of the fibrotic, calcification, and lipid tissues, an inverse FE analysis was performed to estimate the mechanical response of the tissues. Both approaches employed an optimization process to obtain the mechanical properties by minimizing the error between the radial strains obtained from the simulated IVUS and those achieved in each iteration. The second methodology was successfully applied to five distinct real geometries and four different fibrotic tissues, getting median R2 of 0.97 and 0.92, respectively, when comparing the real and estimated behavior curves. In addition, the last technique reduced errors in the estimated plaque strain field by more than 20% during the optimization process, compared to the former approach. The findings enabled the estimation of the stress field over the hyperelastic plaque tissues, providing valuable insights into its risk of rupture.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Casting hybrid twin: physics-based reduced order models enriched with data-driven models enabling the highest accuracy in real-time

  • Ammar, Amine
  • Ben Saada, Mariem
  • Cueto, Elias
  • Chinesta, Francisco
Knowing the thermo-mechanical history of a part during its processing is essential to master the final properties of the product. During forming processes, several parameters can affect it. The development of a surrogate model makes it possible to access history in real time without having to resort to a numerical simulation. We restrict ourselves in this study to the cooling phase of the casting process. The thermal problem has been formulated taking into account the metal as well as the mould. Physical constants such as latent heat, conductivities and heat transfer coefficients has been kept constant. The problem has been parametrized by the coolant temperatures in five different cooling channels. To establish the offline model, multiple simulations are performed based on well-chosen combinations of parameters. The space-time solution of the thermal problem has been solved parametrically. In this work we propose a strategy based on the solution decomposition in space, time, and parameter modes. By applying a machine learning strategy, one should be able to produce modes of the parametric space for new sets of parameters. The machine learning strategy uses either random forest or polynomial fitting regressors. The reconstruction of the thermal solution can then be done using those modes obtained from the parametric space, with the same spatial and temporal basis previously established. This rationale is further extended to establish a model for the ignored part of the physics, in order to describe experimental measures. We present a strategy that makes it possible to calculate this ignorance using the same spatio-temporal basis obtained during the implementation of the numerical model, enabling the efficient construction of processing hybrid twins.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Exploring the muscle architecture effect on the mechanical behaviour of mouse rotator cuff muscles

  • Heras-Sádaba, A.
  • Pérez-Ruiz, A.
  • Martins, P.
  • Ederra, C.
  • Ortiz de Solórzano, C.
  • Abizanda, G.
  • Pons-Villanueva, J.
  • Calvo, B.
  • Grasa, J.
Incorporating detailed muscle architecture aspects into computational models can enable researchers to gain deeper insights into the complexity of muscle function, movement, and performance. In this study, we employed histological, multiphoton image processing, and finite element method techniques to characterise the mechanical dependency on the architectural behaviour of supraspinatus and infraspinatus mouse muscles. While mechanical tests revealed a stiffer passive behaviour in the supraspinatus muscle, the collagen content was found to be two times higher in the infraspinatus. This effect was unveiled by analysing the alignment of fibres during muscle stretch with the 3D models and the parameters obtained in the fitting. Therefore, a strong dependence of muscle behaviour, both active and passive, was found on fibre orientation rather than collagen content.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Optimal trajectory planning combining model-based and data-driven hybrid approaches

  • Ghnatios, Chady
  • Di Lorenzo, Daniele
  • Champaney, Victor
  • Ammar, Amine
  • Cueto, Elias
  • Chinesta, Francisco
Trajectory planning aims at computing an optimal trajectory through the minimization of a cost function. This paper considers four different scenarios: (i) the first concerns a given trajectory on which a cost function is minimized by a acting on the velocity along it; (ii) the second considers trajectories expressed parametrically, from which an optimal path and the velocity along it are computed; (iii), the case in which only the departure and arrival points of the trajectory are known, and the optimal path must be determined; and finally, (iv) the case involving uncertainty in the environment in which the trajectory operates. When the considered cost functions are expressed analytically, the application of Euler–Lagrange equations constitutes an appealing option. However, in many applications, complex cost functions are learned by using black-box machine learning techniques, for instance deep neural networks. In such cases, a neural approach of the trajectory planning becomes an appealing alternative. Different numerical experiments will serve to illustrate the potential of the proposed methodologies on some selected use cases.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Establishing standardization guidelines for finite-element optomechanical simulations of refractive laser surgeries: An application to photorefractive keratectomy

  • Fantaci, Benedetta
  • Calvo, Begoña
  • Barraquer, Rafael
  • Picó, Andrés
  • Ariza-Gracia, Miguel Ángel
Purpose: Computational models can help clinicians plan surgeries by accounting for factors such as mechanical imbalances or testing different surgical techniques beforehand. Different levels of modeling complexity are found in the literature, and it is still not clear what aspects should be included to obtain accurate results in finite-element (FE) corneal models. This work presents a methodology to narrow down minimal requirements of modeling features to report clinical data for a refractive intervention such as PRK. Methods: A pipeline to create FE models of a refractive surgery is presented: It tests different geometries, boundary conditions, loading, and mesh size on the optomechanical simulation output. The mechanical model for the corneal tissue accounts for the collagen fiber distribution in human corneas. Both mechanical and optical outcome are analyzed for the different models. Finally, the methodology is applied to five patient-specific models to ensure accuracy. Results: To simulate the postsurgical corneal optomechanics, our results suggest that the most precise outcome is obtained with patient-specific models with a 100 µm mesh size, sliding boundary condition at the limbus, and intraocular pressure enforced as a distributed load. Conclusions: A methodology for laser surgery simulation has been developed that is able to reproduce the optical target of the laser intervention while also analyzing the mechanical outcome. Translational Relevance: The lack of standardization in modeling refractive interventions leads to different simulation strategies, making difficult to compare them against other publications. This work establishes the standardization guidelines to be followed when performing optomechanical simulations of refractive interventions.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Impact of geometric and hemodynamic changes on a mechanobiological model of atherosclerosis

  • Hernández-López, Patricia
  • Cilla, Myriam
  • Martínez, Miguel Á.
  • Peña, Estefanía
  • Malvè, Mauro
Background and Objective: In this work, the analysis of the importance of hemodynamic updates on a mechanobiological model of atheroma plaque formation is proposed. Methods: For that, we use an idealized and axisymmetric model of carotid artery. In addition, the behavior of endothelial cells depending on hemodynamical changes is analyzed too. A total of three computational simulations are carried out and their results are compared: an uncoupled model and two models that consider the opposite behavior of endothelial cells caused by hemodynamic changes. The model considers transient blood flow using the Navier–Stokes equation. Plasma flow across the endothelium is determined with Darcy’s law and the Kedem–Katchalsky equations, considering the three-pore model, which is also employed for the flow of substances across the endothelium. The behavior of the considered substances in the arterial wall is modeled with convection–diffusion–reaction equations, and the arterial wall is modeled as a hyperelastic Yeoh’s material. Results:Significant variations are noted in both the morphology and stenosis ratio of the plaques when comparing the uncoupled model to the two models incorporating updates for geometry and hemodynamic stimuli. Besides, the phenomenon of double-stenosis is naturally reproduced in the models that consider both geometric and hemodynamical changes due to plaque growth, whereas it cannot be predicted in the uncoupled model. Conclusions: The findings indicate that integrating the plaque growth model with geometric and hemodynamic settings is essential in determining the ultimate shape and dimensions of the carotid plaque.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Non-contact tonometry: predicting intraocular pressure using a material—corneal thickness—independent methodology

  • Redaelli, Elena
  • Calvo, Begoña
  • Rodriguez Matas, Jose Felix
  • Luraghi, Giulia
  • Grasa, Jorge
Introduction: Glaucoma, a leading cause of blindness worldwide, is primarily caused by elevated intraocular pressure (IOP). Accurate and reliable IOP measurements are the key to diagnose the pathology in time and to provide for effective treatment strategies. The currently available methods for measuring IOP include contact and non contact tonometers (NCT), which estimate IOP based on the corneal deformation caused by an external load, that in the case of NCT is an air pulse. The deformation of the cornea during the tonometry is the result of the coupling between the IOP, the mechanical properties of the corneal tissue, the corneal thickness, and the external force applied. Therefore, there is the need to decouple the four contributions to estimate the IOP more reliably.Methods: This paper aims to propose a new methodology to estimate the IOP based on the analysis of the mechanical work performed by the air jet and by the IOP during the NCT test. A numerical eye model is presented, initially deformed by the action of a falling mass to study the energy balance. Subsequently, Fluid-Structure Interaction (FSI) simulations are conducted to simulate the action of Corvis ST.Results and discussion: The new IOP estimation procedure is proposed based on the results of the simulations. The methodology is centred on the analysis of the time of maximum apex velocity rather than the point of first applanation leading to a new IOP estimation not influenced by the geometrical and mechanical corneal factors.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Impact of hypertension and arterial wall expansion on transport properties and atherosclerosis progression

  • Hernández-López, Patricia
  • Laita, Nicolás
  • Cilla, Myriam
  • Martínez, Miguel Ángel
  • Peña, Estefanía
This study explored the impact of hypertension on atheroma plaque formation through a mechanobiological model. The model incorporates blood flow via the Navier–Stokes equation. Plasma flow through the endothelium is determined by Darcy’s law and the Kedem–Katchalsky equations, which consider the three-pore model utilized for substance flow across the endothelium. The behaviour of these substances within the arterial wall is described by convection–diffusion–reaction equations, while the arterial wall itself is modelled as a hyperelastic material using Yeoh’s model. To accurately evaluate hypertension’s influence, adjustments were made to incorporate wall compression-induced wall compaction by radial compression. This compaction impacts three key variables of the transport phenomena: diffusion, porosity, and permeability. Based on the obtained findings, we can conclude that hypertension significantly augments plaque growth, leading to an over 400% increase in plaque thickness. This effect persists regardless of whether wall mechanics are considered. Tortuosity, arterial wall permeability, and porosity have minimal impact on atheroma plaque growth under normal arterial pressure. However, the atheroma plaque growth changes dramatically in hypertensive cases. In such scenarios, the collective influence of all factors—tortuosity, permeability, and porosity—results in nearly a 20% increase in plaque growth. This emphasizes the importance of considering wall compression due to hypertension in patient studies, where elevated blood pressure and high cholesterol levels commonly coexist.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Exploring mechanical damage in fascia: Experiments and advanced constitutive modeling approaches

  • Aparici-Gil, Alejandro
  • Pérez, Marta M.
  • Peña, Estefanía
Biological tissues exhibit complex structures that necessitate mechanical models incorporating details of their key components and the physical processes occurring within the material. Our objective is to enhance the understanding of damage mechanisms in fibered tissues through mechanical testing. This includes conducting uniaxial tensile tests on fascia beyond physiological stretch limits and developing two constitutive models to describe damage and rupture. These models integrate both phenomenological and microstructural perspectives. Two perpendicular directions, corresponding to the two families of collagen fibers, were compared: the longitudinal direction, characterized by greater stiffness, and the transverse direction. The mean Cauchy rupture stress ( ) was reported as 16.67 for the longitudinal direction and 4.76 MPa for the transverse direction, with a significant difference observed between them (-value 0.05). Similarly, a significant difference in stored strain energy was found between the two directions (-value 0.05) between directions, being in longitudinal equal to 1.33 and 0.49 in transversal one. However, rupture stretches () did not exhibit a significant difference (-value 0.05) with values of 1.17 and 1.22 for the longitudinal and transverse directions, respectively. In this study, a hyperelastic constitutive model for fascia was modified to incorporate damage effects into the strain energy function. Additionally, an extended version of a microstructural damage model was developed to effectively replicate the experimental data. The proposed damage models successfully captured the stress–strain behavior and accurately represented the damage process. The coefficient of determination for the fitted data ranged from 0.616 to 0.973, except for Sample IV, which exhibited an value of 0.251 when using the phenomenological model. In all cases, the microstructural model provided a more accurate fit compared to the phenomenological model, with values ranging from 0.748 to 0.927.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

What about the mechanical behaviour and modelling of arteries in radial direction?

  • Ríos-Ruíz, Itziar
  • Martínez, Miguel A.
  • Peña, Estefanía
Understanding the physiological behaviour of arteries in the radial direction is crucial for establishing a reference point to detect and analyse pathological changes. In this study, the influence of the radial component of the aorta will be investigated by performing experimental tests on porcine aortic tissue in the three main directions of the aorta: circumferential, longitudinal and radial. The results obtained in all directions will be analysed and compared in order to contribute to a comprehensive understanding of the healthy behaviour of the vessel. Our results demonstrate that the aorta exhibits nonlinear behaviour under compression and tensile loading in the radial direction. Moreover, tissue stiffening progresses more prominently under compression compared to tensile loading. We have found that the tensile stiffness in the ATA is higher compared to the other two regions examined. The Neo-Hookean and Demiray models were selected to describe the isotropic contribution when fitting the uniaxial response of the circumferential and longitudinal samples using the GOH model. Neo-Hookean model fall short ( ) in accurately replicating the observed behaviour of the aorta in the radial direction and Demiray model showing better fitting results ().
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Predicting the biomechanical stability of IOLs inside the postcataract capsular bag with a finite element model: Predicting the IOL position after cataract surgery

  • Cabeza-Gil, I.
  • Calvo, B.
Background and Objectives: Although cataract surgery is a safe operation in developed countries, there is still room for improvement in terms of patient satisfaction. One of the key issues is assessing the biomechanical stability of the IOL within the capsular bag to avoid refractive errors that lead to a second surgery. For that purpose, a numerical model was developed to predict IOL position inside the capsular bag in the short- and long-term. Methods: A finite element model containing the implanted IOL, the postcataract capsular bag, the zonules, and a portion of the ciliary body was designed. The C-loop hydrophobic LUCIA IOL was used to validate the numerical model and two more worldwide IOL designs were tested: the double C-loop hydrophobic POD FT IOL and the plate hydrophilic AT LISA IOL. To analyze the biomechanical stability in the long-term, the effect of the fusion footprint, which occurs days following cataract surgery, was simulated. Moreover, several scenarios were analyzed: the size and location of the capsulorexhis, the capsular bag diameter, the initial geometry of the capsular bag, and the material properties of the bag. Results: The biomechanical stability of the LUCIA IOL was simulated and successfully compared with the in vitro results. The plate AT LISA design deformed the capsular bag diameter up to 11.0 mm against 10.5 mm for the other designs. This design presented higher axial displacement and lower rotation, 0.19 mm and 0.2°, than the C-loop design, 0.09 mm and 0.9°. Conclusions: All optomechanical biomarkers were optimal, assuring good optical performance of the three IOLs under investigation. Our findings showed that the capsulorexhis size influences the stiffness of the capsular bag; however, the shape in the anterior and posterior curvature surfaces of the bag barely affect. The results also suggested that the IOL is prone to mechanical perturbations with the fusion footprint, but they were not high enough to produce a significant refractive error. The proposed model could be a breakthrough in the selection of haptic design according to patient criteria.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Mathematical modelling of endovascular drug delivery: Balloons versus stents; 35427751

  • Escuer, J.
  • Schmidt, A. F.
  • Peña, E.
  • Martínez, M. A.
  • McGinty, S.
The most common treatment for obstructive coronary artery disease (CAD) is the implantation of a permanent drug-eluting stent (DES). Not only has this permanency been associated with delayed healing of the artery, but it also poses challenges when treating subsequent re-narrowing due to in-stent restenosis (ISR). Drug-coated balloons (DCBs) provide a potential solution to each of these issues. While their use has been primarily limited to treating ISR, in recent years, DCBs have emerged as an attractive potential alternative to DESs for the treatment of certain de novo lesions. However, there remain a number of concerns related to the safety and efficacy of these devices. Firstly, unlike DESs, DCBs necessitate a very short drug delivery window, favouring a higher drug loading. Secondly, while the majority of coronary DCBs in Europe are coated with paclitaxel, the potential mortality signal raised with paclitaxel DCBs in peripheral interventions has shifted efforts towards the development of limus-eluting balloons. The purpose of this paper is to provide a computational model that allows drug delivery from DCBs and DESs to be investigated and compared. We present a comprehensive computational framework that employs a 2D-axisymmetric geometry, incorporates two nonlinear phases of drug binding (specific and non-specific) and includes the influence of diffusion and advection, within a multilayer arterial wall. We utilise this framework to (i) simulate drug delivery from different types of balloon platform; (ii) explore the influence of DCB application time; (iii) elucidate the importance on release kinetics of elevated pressure during DCB application; (iv) compare DCB delivery of two different drugs (sirolimus and paclitaxel) and; (v) compare simulations of DESs versus DCBs. Key measures of comparison are related to safety (drug content in tissue, DC) and efficacy (specific binding site saturation, %SBSS) markers. Our results highlight the pros and cons of each device in terms of DC and %SBSS levels achieved and, moreover, indicate the potential for designing a DCB that gives rise to sufficiently similar safety and efficacy indicators as current commercial DESs.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Impact of mechanical properties of aneurysms and intraluminal thrombus on abdominal aortic aneurysm aoutcomes

  • Caruso, Gaia
  • Martínez, Miguel Ángel
  • Peña, Estefanía
This study aims to examine how changes in material coefficients impact the mechanical responses of AAA models, including both cases with and without the ILT. The main focus will be on identifying the material coefficients that most significantly influence strain and stress fields, using the GHO model, which is widely regarded as the most popular hyperelastic model. The findings of this study reveal that compliant AAAs are particularly sensitive to fiber dispersion, which exerts a substantial influence on stress distribution and deformation patterns. In stiffer AAAs, however, matrix stiffness emerges as the key player. Notably, the study of interactions among all GHO parameters demonstrate that even minor adjustments can dramatically shift model behavior, emphasizing the importance of finely fitted parameter combinations for accurate predictions. The impact of ILT material properties on AAA mechanical behavior was found to be relatively minor, indicating that precise fitting of ILT coefficients may not be essential. However, the inclusion of the ILT itself was important, as it played a crucial role in shielding the AAA wall by reducing stress. This study offers valuable insights into the material modeling of AAA tissue and the significance of the ILT. The findings can be instrumental in optimizing patient-specific computational models, enhancing the accuracy of AAA wall material behavior, while also incorporating the ILT’s effects.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

A POD-NN methodology to determine in vivo mechanical properties of soft tissues. Application to human cornea deformed by Corvis ST test

  • Redaelli, Elena
  • Calvo, Begoña
  • Rodríguez Matas, José Felix
  • Luraghi, Giulia
  • Grasa, Jorge
The interaction between optical and biomechanical properties of the corneal tissue is crucial for the eye’s ability to refract and focus light. The mechanical properties vary among individuals and can change over time due to factors such as eye growth, ageing, and diseases like keratoconus. Estimating these properties is crucial for diagnosing ocular conditions, improving surgical outcomes, and enhancing vision quality, especially given increasing life expectancies and societal demands. Current ex-vivo methods for evaluating corneal mechanical properties are limited and not patient-specific. This study aims to develop a model to estimate in real-time the mechanical properties of the corneal tissue in-vivo. It is composed both by a proof of concept and by a clinical application. Regarding the proof of concept, we used high-fidelity Fluid-Structure Interaction (FSI) simulations of Non-Contact Tonometry (NCT) with Corvis ST® (OCULUS, Wetzlar, Germany) device to create a large dataset of corneal deformation evolution. Proper Orthogonal Decomposition (POD) was applied to this dataset to identify principal modes of variation, resulting in a reduced-order model (ROM). We then trained a Neural Network (NN) using the reduced coefficients, intraocular pressure (IOP), and corneal geometry derived from Pentacam® (OCULUS, Wetzlar, Germany) elevation data to predict the mechanical properties of the corneal tissue. This methodology was then applied to a clinical case in which the mechanical properties of the corneal tissue are estimated based on Corvis ST results. Our method demonstrated the potential for real-time, in-vivo estimation of corneal biomechanics, offering a significant advancement over traditional approaches that require time-consuming numerical simulations. This model, being entirely data-driven, eliminates the need for complex inverse analyses, providing an efficient and accurate tool to be implemented directly in the Corvis ST device.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Uniaxial, biaxial, and planar tension properties of deep fascia and a constitutive model to simultaneously reproduce these strain states

  • Aparici-Gil, Alejandro
  • Peña, Estefanía
  • Pérez, Marta M.
This study aims to provide an in-depth analysis of the mechanical behavior of deep fascia through a comprehensive multidimensional characterization, including uniaxial, biaxial, and planar tension tests. To determine material parameters via test fitting, both a newly developed coupled exponential energy function and a previously proposed uncoupled exponential model—both considering two perpendicular fiber directions—are evaluated. For the uniaxial response, the mean stress measured was 3.96 MPa in the longitudinal direction and 0.6 MPa in the transverse direction at a stretch (λ) of 1.055. In planar tension tests, stress values of 0.43 MPa and 0.11 MPa were recorded for the longitudinal and transverse directions, respectively, at λ = 1.72. Under equibiaxial loading conditions, the mean stresses were 3.16 MPa and 1.2 MPa for the longitudinal and transverse directions when λ reached 1.037, respectively. The fitting results indicate that while the uncoupled exponential model effectively captures the uniaxial and equibiaxial experimental data, it fails to predict other mechanical responses accurately. In contrast, the coupled exponential strain energy function (SEF) demonstrates robust performance in both fitting and prediction. Additionally, an analysis was conducted to assess how the number and combination of tests influence the determination of material parameters. Findings suggest that a single biaxial test incorporating three loading ratios is sufficient to accurately capture and predict uniaxial, planar tension, and other biaxial strain states.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Mechanical characterization of infarcted porcine hearts using left anterior descending and left circumflex coronary artery models

  • Laita, Nicolás
  • Aparici-Gil, Alejandro
  • Oliván-Viguera, Aida
  • Pérez-Martínez, Alba
  • Wu, Ming
  • García de Yébenes, Manuel
  • Abizanda, Gloria
  • Janssens, Stephan
  • Prósper, Felipe
  • Mazo Vega, Manuel M.
  • Martínez, Miguel Ángel
  • Doblaré, Manuel
  • Peña, Estefanía
This study comprehensively analyzes passive mechanical and structural changes of cardiac tissue 6 weeks after myocardial infarction (MI) by biaxial, simple triaxial shear, and confined compression characterization. We considered a porcine model, comparing two MI types: Left Anterior Descending (LAD) artery and Left Circumflex (LCX) artery occlusions. LAD model generated apical transmurally infarcted hearts, while the LCX model generated medial heterogeneous infarctions ranging from mild locally infarcted tissue to transmurally infarcted tissue. Infarcted tissue exhibited significantly higher stiffness than healthy tissue. When peak equibiaxial stretch increases up to 20%, the stress increase is 2.19 for medial locally infarcted tissue, 4.49 for medial fully infarcted tissue, and 6.26 for apical fully infarcted tissue. Fully infarcted animals showed significant macroscopic geometrical remodeling, with thickness reductions in the infarcted area of 45%–60%, while locally infarcted tissue showed no thinning. The anisotropy of healthy myocardium was also altered post-MI: medial infarcts exhibited preferentially circumferential anisotropy, while apical infarctions increased isotropy. Histological analysis validated these mechanical alterations, revealing a substantial increase in collagen content in infarcted regions. In LCX infarctions, collagen distribution was uniformly aligned, whereas in LAD ones, its distribution was spatially heterogeneous. Non-infarcted tissue far from the infarction did not exhibit changes in mechanical properties or collagen content, suggesting a localized effect at least 6 weeks post-MI. These findings highlight the importance of considering the extent and location of MI when developing personalized therapeutic strategies. Statement of Significance This work provides a comprehensive mechanical and histological assessment of post-infarct porcine myocardium using advanced multimodal testing. Unlike previous studies, we compare two infarct types (LAD and LCX) under identical conditions and examine regional and severity-dependent differences in stiffness, compressibility, and anisotropy. We show that infarction induces local rather than global changes in tissue passive mechanics, modulated by infarct geometry and scar distribution. These insights support more accurate cardiac modeling and may guide personalized therapeutic strategies after myocardial infarction.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Biomechanically informed patient-specific in silico models for laser refractive surgery

  • Fantaci, Benedetta
  • Redaelli, Elena
  • Martí, Mònica
  • Julio, Gemma
  • Barraquer, Anton
  • Lamarca, Jose
  • Grasa, Jorge
  • Calvo, Begoña
Purpose: Corneal biomechanics plays a key role in the planning and outcomes of laser refractive surgery. This study presents a validated methodology for simulating patient-specific refractive treatments, focusing on the optomechanical effects of the three most commonly performed procedures: PRK, LASIK, and SMILE. Methods: For the first time, patient-specific mechanical properties of the cornea were incorporated into finite element simulations. These properties were estimated using an artificial neural network trained on in silico data from fluid–structure interaction models of non-contact tonometry. The tool takes as input corneal deformation images acquired with the Corvis ST device, intraocular pressure (IOP), and corneal geometry obtained from Pentacam imaging. IOP is estimated independently of corneal geometry and mechanical properties using a novel algorithm developed in prior studies. The methodology was tested on a cohort of 58 eyes from 29 patients who underwent one of the three procedures. Results: By integrating patient-specific geometry, IOP, and biomechanical characterization, the proposed framework successfully simulated postoperative corneal responses, yielding a mean dioptric error of +0.40 ± 0.30 D relative to clinical outcomes. Among the three procedures, SMILE produced the highest mechanical impact on the corneal model. Conclusion: This study introduces a personalized, biomechanically informed approach to simulate corneal behavior following refractive surgery. The proposed framework enhances surgical planning and improves prediction of postoperative refractive stability, offering a step toward personalized refractive correction and safer, more predictable clinical outcomes.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Nonlinear viscoelastic effects of fascia: experimental findings and constitutive modelling

  • Aparici-Gil, Alejandro
  • Pérez, Marta M.
  • Peña, Estefanía
This study provides a comprehensive biomechanical characterization of the fascia lata, integrating systematic stress-relaxation protocols and, for the first time, dynamic mechanical analysis to resolve its complex dissipative mechanisms. Experimental tests were conducted along both longitudinal and transverse fibre orientations across multiple strain levels and frequencies to assess the synergistic effects of anisotropy, strain magnitude and loading rate. To describe these phenomena, three visco-hyperelastic constitutive frameworks were developed and compared: a first-order linear model (n=1), a generalized Maxwell model with two internal variables (n=2) and a nonlinear strain-dependent formulation. Results reveal a marked anisotropic viscoelastic profile, with the transverse direction exhibiting a significantly higher relaxation capacity (ratio of 0.666±0.144 at 2.5% strain) compared to the longitudinal axis (0.817±0.049), driven by the viscous flow of the interfibrillar ground substance. Although the tissue demonstrated marginal nonlinear viscoelasticity, the linear n=2 model outperformed the nonlinear n=1 framework, achieving superior predictive fidelity (R2=0.7321, NRMSE=0.1216 versus R2=0.7200, RMSE=0.2949 MPa). Results indicate that spectral refinement outweighs nonlinear complexity in this context. Specifically, the dual-branch linear approach captures the tissue's fundamental dissipation more effectively than a single-branch nonlinear formulation, which tends towards over-parametrization.