Pasar al contenido principal

DESARROLLO DE MODELOS IN SILICO PARA EL ANALISIS DE LESIONES TENDINOMUSCULARES UTILIZANDO TECNICAS BASADAS EN INTELIGENCIA ARTIFICIAL

PID2023-147987OB-C31

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal para Impulsar la Investigación Científico-Técnica y su Transferencia
Subprograma Subprograma Estatal de Generación de Conocimiento
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2023
Plan Estatal 2021-2023 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDAD DE ZARAGOZA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Corneal deformation mapping and FE-based strain analysis via digital image correlation: Biomechanical changes after CXL and laser refractive surgery

  • Fantaci, Benedetta
  • Frechilla, Alejandro
  • Frigelli, Matteo
  • Büchler, Philippe
  • Kling, Sabine
  • Calvo, Begoña
Data will be made available on request., Accurate assessment of corneal mechanical properties is critical for understanding ocular biomechanics, predicting refractive surgery outcomes, and optimizing cross-linking (CXL) treatments. Conventional uniaxial tensile testing is limited by non-physiological boundary conditions and simplified stress distributions. Inflation testing more closely reproduces the in vivo stress state but has traditionally lacked spatially distributed deformation mapping. In this work, we present an integrated experimental–computational protocol combining inflation testing of freshly enucleated porcine eyes with high-resolution three-dimensional digital image correlation (3D-DIC). Fifteen corneas were analyzed across three cohorts: (i) de-epithelialized controls, (ii) CXL-treated (standard Dresden protocol), and (iii) anterior stromal ablation via femtosecond laser. Samples were subjected to controlled intraocular pressure (IOP) elevations up to 40 mmHg. The 3D-DIC approach provided dense, pointwise displacement and strain maps across the anterior surface, successfully quantifying the localized stiffening effects of CXL and the increased compliance induced by stromal ablation. The surface kinematics was post-processed using a membrane-theory formulation to resolve principal in-plane strains, from which a regional strain metric was derived for inverse modeling with a fully three-dimensional finite element model to estimate anisotropic hyperelastic parameters of porcine corneal tissue. Overall, the method establishes an end-to-end route from physiologic loading to regional surface strain quantification and constitutive parameter identification, enabling quantitative evaluation of treatment-induced biomechanical changes in the cornea., This work received funding from the University of Zaragoza (project I-2021/010/PIP OBERON — Opto-Biomechanical Eye Research Network/PIP); from the Spanish Ministerio de Ciencia, Innovación Universidades through grant PID2023-147987OB-C31, financed by MICIU/AEI/10.13039/501100011033 and by FEDER, EU; and from the Government of Aragon through research group grant T24-23R (co-financed by FEDER). Part of the work was performed at the ICTS “NANBIOSIS”, specifically the High Performance Computing Unit (U27) of CIBER in Bioengineering, Biomaterials & Nanomedicine (CIBER-BBN) at the University of Zaragoza. CIBER activities are financed by the Instituto de Salud Carlos III with assistance from the European Regional Development Fund., Peer reviewed
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Modeling and fabrication of MEW-3D tubular scaffolds with tendon mechanical behavior for tenocyte differentiation

  • Grasa, Jorge
  • Urbiola, Ainhoa
  • Flandes-Iparraguirre, María
  • Extramiana, Leire
  • Ederra, Cristina
  • Ortiz-de-Solórzano, Carlos
  • Llombart, Rafael
  • Valentí, Andrés
  • Baquero, Enrique
  • Heras-Sádaba, Ángel
  • Pons-Villanueva, Juan
  • Calvo, Begoña
  • Pérez-Ruiz, Ana
Tendon injuries present substantial challenges in clinical settings, where traditional treatments often lead to suboptimal outcomes, including scar tissue formation, reduced strength, limited range of motion, and re-ruptures. These difficulties primarily arise from the complex hierarchical structure of tendons and their limited healing capacity. Tissue engineering offers promising solutions for tendon regeneration and muscle-to-bone reconnection, typically through the use of biodegradable scaffolds that mimic the extracellular matrix of tendons, thereby supporting cell growth and tissue formation. However, several obstacles must be addressed to develop tendon reconstruction strategies suitable for clinical application. In this study, we developed computational models to design and produce Melt Electrowriting (MEW)-3D tubular structures that replicate the mechanical properties of native mouse Achilles tendons, improving the guidance of tenocyte growth and differentiation. These models incorporated a new approach to consider the non-continuum nature of printed scaffolds formed by sets of fibers interacting with one another. Moreover, these structures facilitated cell confinement, expansion, and alignment, resulting in bundle-like formations with enhanced tensile properties. Importantly, tenocyte differentiation was achieved through a two-step cell culture protocol, which involved transitioning cells from high to low serum media. This approach effectively mitigated the phenotypic drift that often occurs with long-term cell cultures. Statement of Significance Tendon injuries are a common issue in healthcare, often leading to scar tissue, weaker tendons, limited mobility, and frequent re-injury. Tendon engineering aims to address these challenges by using biodegradable “scaffolds” that mimic the natural tendon environment, supporting cell growth and tissue repair. In this study, we developed computational models to design 3D tubular structures using a printing method called Melt Electrowriting (MEW). These structures replicate the mechanical properties of mouse Achilles tendons, guiding tendon cells to grow and differentiate effectively. By creating scaffolds from interwoven fibers, we closely replicated how natural tendon fibers interact, allowing cells to form strong, organized bundles. This approach may improve engineered tendon strength and durability, addressing key challenges in tendon reconstruction strategies.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Biomechanically informed patient-specific in silico models for laser refractive surgery

  • Fantaci, Benedetta
  • Redaelli, Elena
  • Martí, Mònica
  • Julio, Gemma
  • Barraquer, Anton
  • Lamarca, Jose
  • Grasa, Jorge
  • Calvo, Begoña
Purpose: Corneal biomechanics plays a key role in the planning and outcomes of laser refractive surgery. This study presents a validated methodology for simulating patient-specific refractive treatments, focusing on the optomechanical effects of the three most commonly performed procedures: PRK, LASIK, and SMILE. Methods: For the first time, patient-specific mechanical properties of the cornea were incorporated into finite element simulations. These properties were estimated using an artificial neural network trained on in silico data from fluid–structure interaction models of non-contact tonometry. The tool takes as input corneal deformation images acquired with the Corvis ST device, intraocular pressure (IOP), and corneal geometry obtained from Pentacam imaging. IOP is estimated independently of corneal geometry and mechanical properties using a novel algorithm developed in prior studies. The methodology was tested on a cohort of 58 eyes from 29 patients who underwent one of the three procedures. Results: By integrating patient-specific geometry, IOP, and biomechanical characterization, the proposed framework successfully simulated postoperative corneal responses, yielding a mean dioptric error of +0.40 ± 0.30 D relative to clinical outcomes. Among the three procedures, SMILE produced the highest mechanical impact on the corneal model. Conclusion: This study introduces a personalized, biomechanically informed approach to simulate corneal behavior following refractive surgery. The proposed framework enhances surgical planning and improves prediction of postoperative refractive stability, offering a step toward personalized refractive correction and safer, more predictable clinical outcomes.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Corneal deformation mapping and FE-based strain analysis via digital image correlation: Biomechanical changes after CXL and laser refractive surgery

  • Fantaci, Benedetta
  • Frechilla, Alejandro
  • Frigelli, Matteo
  • Büchler, Philippe
  • Kling, Sabine
  • Calvo, Begoña
Accurate assessment of corneal mechanical properties is critical for understanding ocular biomechanics, predicting refractive surgery outcomes, and optimizing cross-linking (CXL) treatments. Conventional uniaxial tensile testing is limited by non-physiological boundary conditions and simplified stress distributions. Inflation testing more closely reproduces the in vivo stress state but has traditionally lacked spatially distributed deformation mapping. In this work, we present an integrated experimental–computational protocol combining inflation testing of freshly enucleated porcine eyes with high-resolution three-dimensional digital image correlation (3D-DIC). Fifteen corneas were analyzed across three cohorts: (i) de-epithelialized controls, (ii) CXL-treated (standard Dresden protocol), and (iii) anterior stromal ablation via femtosecond laser. Samples were subjected to controlled intraocular pressure (IOP) elevations up to 40 mmHg. The 3D-DIC approach provided dense, pointwise displacement and strain maps across the anterior surface, successfully quantifying the localized stiffening effects of CXL and the increased compliance induced by stromal ablation. The surface kinematics was post-processed using a membrane-theory formulation to resolve principal in-plane strains, from which a regional strain metric was derived for inverse modeling with a fully three-dimensional finite element model to estimate anisotropic hyperelastic parameters of porcine corneal tissue. Overall, the method establishes an end-to-end route from physiologic loading to regional surface strain quantification and constitutive parameter identification, enabling quantitative evaluation of treatment-induced biomechanical changes in the cornea.