Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 17
Encontrada(s) 1 página(s)

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

A 3D multi-scale skeletal muscle model to predict active and passive responses. Application to intra-abdominal pressure prediction

  • Karami, Mina
  • Zohoor, Hassan
  • Calvo, Begoña
  • Grasa, Jorge
Computational models have been used extensively to study the behavior of skeletal muscle structures, however few of these models are able to evaluate their 3D active response using as input experimental measurements such as electromyography. Hence, improving the activation mechanisms in simulation models can provide interesting and useful achievements in this field. Therefore, the purpose of this paper was to develop a multi-scale chemo-mechanical material model to consider the active behavior of skeletal muscle in 3D geometries. The model was used to investigate the response of abdominal muscles which represent a challenging scenario due to their complex geometry and anatomical conditions. Realistic muscle geometries and other tissues of the human abdomen, including transverse abdominis (TA), internal oblique (IO), external oblique (EO), rectus abdominis (RA), rectus sheath (RSH), linea alba (LA) and aponeurosis (APO) were considered. Since the geometry of these tissues was obtained from magnetic resonance images, an iterative algorithm was implemented to find the initial stress state that achieve the equilibrium of them with the intra-abdominal pressure. In order to investigate the functionality of the proposed model, the increase of intra-abdominal pressure was calculated during cough in the supine position while the Ca2+ signal for activating the muscles was set in regard to experimentally recorded electrical activity from previous studies. The amount of intra-abdominal pressure calculated by the model is consistent with reported experimental results. This model can serve as a virtual laboratory to analyze the role of the abdominal wall components in different conditions, such as the performance of meshes used for repairing hernia defects.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Digital twins for monitoring and predicting the cooking of food products: A case study for a French crêpe

  • Cabeza-Gil, Iulen
  • Ríos-Ruiz, Itziar
  • Martínez, Miguel Ángel
  • Calvo, Begoña
  • Grasa, Jorge
The food industry is shifting toward automated and customized processes, leading to the emergence of smart cooking devices that improve cooking outcomes. However, these devices can be invasive, costly, and only applicable to certain foods. To address these issues, a noninvasive digital twin that monitors food during cooking using a common frying pan with a temperature sensor and a weighing scale is proposed. A case study for a French crêpe is presented, in which we developed a digital twin using a neural network trained on over 400,000 simulation data points. The results show that the digital twin can accurately estimate the properties of the crêpe during cooking in real time with a mean absolute percentage error of less than 5% and predict when it will be cooked according to user criteria. The approach offers significant benefits over existing smart cooking devices, as it can be applied to a wide range of cooking processes. The proposed technology enables food process automation and has potential applications in both home and professional kitchens.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Towards domestic cooking efficiency: A case study on burger pan frying using experimental and computational results

  • Hernández-Alhambra, E.
  • Guíu, P.
  • Cabeza-Gil, I.
  • Ferrer-Mairal, A.
  • Martínez, M. A.
  • Calvo, B.
  • Grasa, J.
  • Salvador, M. L.
It is well known that the use of efficient domestic cooking appliances and equipment can not only save energy, but also improve the quality of the food being prepared. This work raises the question of whether cooking procedures can also contribute to this energy efficiency. Focusing on burger pan frying, experimental data were used to develop a model able to predict cooking outcomes under different power levels supplied by an induction hob. The proposed model takes into account not only the heat consumed by water evaporation in the contact region but also the shrinkage process of the hamburger. A new formulation based on the multiplicative decomposition of the strain deformation gradient is proposed to describe the observed decoupling between weight and volume loss during the process. The model properly predicts temperature, moisture loss and shrinkage, and allows elucidation of the effects of supplying different amounts of energy on the final water content.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Modeling biological growth of human keratoconus: On the effect of tissue degradation, location and size

  • Fantaci, Benedetta
  • Calvo, Begoña
  • Rodríguez, José Félix
Keratoconus is a non-inflammatory bilateral disease, that usually occurs in the inferior-temporal region, where the cornea bulges out and becomes thinner, due to the gradual loss of structural organization in corneal tissue. Degenerated extracellular matrix and fibers breakage have been observed in keratoconic corneas, that may promote the progression of the pathology. While keratoconus histopathology has been widely described in literature, its etiology is still not clear. Being able to fully understand keratoconus growing process could be crucial to detect its development and improve prevention strategies. This work proposes a novel continuum-based keratoconus growth model. The proposed framework accounts for the structural changes occurring in the underlying tissue during the progression of the disease, as indicated in experiments. The developed formulation is able to replicate the typical bulging and thinning of keratoconic corneas, as well as different forms in terms of shape, as they are commonly classified in clinics (nipple, oval and globus cones). The cone that is obtained constitutes a permanent deformed state, not pressure dependent. The resulting model may help to better understand the etiology of the behavior of this disease with the aim of improving the diagnosis and the treatment of the pathology.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Predicting optimal flipping conditions during burger pan cooking with a numerical model

  • Hernández-Alhambra, E.
  • Guiu, P.
  • Ferrer-Mairal, A.
  • Martínez, M.A.
  • Calvo, B.
  • Grasa, J.
  • Salvador, M.L.
This study analyzes the influence of the number of flips on the cooking performance of burgers by heating contact using results from both experimental test and computational simulation. The analysis employs a previously developed multiphysics model that accounts for heat and moisture transfer as well as product deformation. The turning process was simulated considering two heat sources representing the cooking pan that are alternately activated and deactivated to heat either surface of the product. Furthermore, a set of experiments were carried out to validate the model outcomes recording data of temperature at the center and upper surface of the burger, weight loss, and shrinkage at different number of flips. When performing only one flip, great moisture expelling was observed at the top surface, while multiple flips facilitates moisture retention, reducing cooking losses and shrinkage since it allows for a reduction in cooking time to reach the desired temperature. However, more than five flips do not significantly improve these effects.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Unraveling the impact of laser refractive surgery on corneal ectasia: an in silico study

  • Fantaci, Benedetta
  • Rodriguez Matas, José Félix
  • Squartecchia, Vittoria
  • Vavassori, Lucia
  • Calvo, Begoña
IntroductionLaser refractive surgeries are a safe option for low-to-moderate refractive corrections, providing excellent visual outcomes. Over the years, various procedures have been introduced into clinical practice, but the most performed today remain Photorefractive Keratectomy (PRK), Laser In-Situ Keratomileusis (LASIK), and Small Incision Lenticule Extraction (SMILE). Although laser refractive treatments are considered safe, clinicians have focused on the risk of post-surgical ectasia, a rare but serious complication. Ectasia is characterized by progressive corneal thinning and steepening, leading to vision distortion, irregular astigmatism, and in some cases, a reduction of visual acuity. It is still debated whether laser refractive surgeries can cause ectasia as an iatrogenic condition or merely accelerate the progression of an underlying corneal pathology, not detected during pre-surgical screening. The proposed work investigates the relationship among three laser refractive surgeries (PRK, LASIK and SMILE), currently performed in clinical practice, and ectasia onset and progression by means of an in silico analysis.MethodsAn average 3D finite-element corneal model is developed and a pathological area, characterized by reduced stiffness of varying severity grades, is defined to analyze its influence on ectasia development and progression in the pre-surgical state. Three laser treatments (PRK, LASIK and SMILE) are simulated on healthy and pathological models. Pre- and post-surgical conditions are compared to check whether any procedure worsens the pre-surgical pathological state. The optomechanical effect of each procedure on the cornea is analyzed at both healthy and pathological conditions and compared to establish which refractive procedure mostly affects corneal structure.Results and discussionWhile the three refractive procedures showed different behaviors in terms of mechanical changes affecting the cornea, from an optical perspective, as the pathology severity worsened, none of the surgeries caused a worsening in the cone’s severity with respect to pre-surgical pathological conditions. This result suggests that surgeries may have a limited role in causing post-surgical ectasia, as it seems more plausible that they accelerate the progression of an underlying pathological condition. Among the three procedures, PRK was found to be the least invasive treatment from a mechanical perspective, while SMILE showed the greatest impact on the posterior surface, suggesting a potential long-term risk for ectasia progression.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Modeling and fabrication of MEW-3D tubular scaffolds with tendon mechanical behavior for tenocyte differentiation

  • Grasa, Jorge
  • Urbiola, Ainhoa
  • Flandes-Iparraguirre, María
  • Extramiana, Leire
  • Ederra, Cristina
  • Ortiz-de-Solórzano, Carlos
  • Llombart, Rafael
  • Valentí, Andrés
  • Baquero, Enrique
  • Heras-Sádaba, Ángel
  • Pons-Villanueva, Juan
  • Calvo, Begoña
  • Pérez-Ruiz, Ana
Tendon injuries present substantial challenges in clinical settings, where traditional treatments often lead to suboptimal outcomes, including scar tissue formation, reduced strength, limited range of motion, and re-ruptures. These difficulties primarily arise from the complex hierarchical structure of tendons and their limited healing capacity. Tissue engineering offers promising solutions for tendon regeneration and muscle-to-bone reconnection, typically through the use of biodegradable scaffolds that mimic the extracellular matrix of tendons, thereby supporting cell growth and tissue formation. However, several obstacles must be addressed to develop tendon reconstruction strategies suitable for clinical application. In this study, we developed computational models to design and produce Melt Electrowriting (MEW)-3D tubular structures that replicate the mechanical properties of native mouse Achilles tendons, improving the guidance of tenocyte growth and differentiation. These models incorporated a new approach to consider the non-continuum nature of printed scaffolds formed by sets of fibers interacting with one another. Moreover, these structures facilitated cell confinement, expansion, and alignment, resulting in bundle-like formations with enhanced tensile properties. Importantly, tenocyte differentiation was achieved through a two-step cell culture protocol, which involved transitioning cells from high to low serum media. This approach effectively mitigated the phenotypic drift that often occurs with long-term cell cultures. Statement of Significance Tendon injuries are a common issue in healthcare, often leading to scar tissue, weaker tendons, limited mobility, and frequent re-injury. Tendon engineering aims to address these challenges by using biodegradable “scaffolds” that mimic the natural tendon environment, supporting cell growth and tissue repair. In this study, we developed computational models to design 3D tubular structures using a printing method called Melt Electrowriting (MEW). These structures replicate the mechanical properties of mouse Achilles tendons, guiding tendon cells to grow and differentiate effectively. By creating scaffolds from interwoven fibers, we closely replicated how natural tendon fibers interact, allowing cells to form strong, organized bundles. This approach may improve engineered tendon strength and durability, addressing key challenges in tendon reconstruction strategies.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Otros (Other)

Embracing cellular complexity: Toward integrative, mechanobiological, and computational frontiers in cell science

  • Doweidar, Mohamed H.
In recent decades, cell biology has evolved from a discipline centered on isolated structures and pathways into a vibrant, multidisciplinary science that seeks to understand the cell as a dynamic, complex system. This transformation has been fueled by progress in imaging, high-throughput omics, biomechanical measurements, and - critically - advanced computational modeling. These developments now allow us to probe, quantify, and simulate cell behavior across biological, temporal, and mechanical scales.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Otros (Other)

Cancer Cell Resistance: The Emergent Intelligence of Adaptation and the Need for Biophysical Integration

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Minimally Invasive Glaucoma Surgery Procedure in the Human Eye. A Fluid Structure Interaction Study

  • Redaelli, Elena
  • Perri, Letizia Maria
  • Calvo, Begoña
  • Grasa, Jorge
  • Luraghi, Giulia
Aqueous humor is a clear fluid pressurized at an intraocular pressure (IOP) within a range of 8–20 mmHg in healthy conditions that fills and shapes the anterior and posterior chambers of the eye. It is typically drained through the trabecular meshwork, but reduced permeability of this structure can lead to impaired drainage, elevated IOP, and the development of glaucoma. Minimally invasive glaucoma surgeries (MIGS) offer a treatment option by implanting micro stents to create alternative pathways for aqueous humor drainage. Despite their potential, limited research has explored the biomechanical changes in ocular tissues and the hydrodynamic interactions following MIGS implantation. This paper aims to study the aqueous humor flow after the surgery by means of computational simulations. For the first time, the implantation process has been simulated to assess residual stresses on ocular structures post‐implantation. Then, this study introduces a Fluid–Structure Interaction (FSI) simulation to model the aqueous humor dynamics after MIGS implantation. The results demonstrate the necessity of FSI simulations, as they reveal the interplay between the eye's biomechanical properties and the aqueous humor dynamics. The advantage of using an FSI simulation is its ability to capture the aqueous humor dynamics, providing a more realistic representation compared to the Computational Fluid Dynamic (CFD) simulations found in the literature. Using only CFD, the outflow velocity of the aqueous humor through the stent is approximately 1e−4 m/s, whereas with an FSI approach, the velocity reaches up to 0.8 m/s as the deformation of the ocular tissues has a substantial impact on the flow dynamics and cannot be neglected. This novel methodology can be potentially used for visualizing and quantifying the aqueous humor flow as a function of implant design, position and dimensions in order to design next‐generation MIGS devices and optimize implantation strategies, offering significant advancements in glaucoma treatment.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Effect of electrical conductivity on the inactivation of Anisakis spp. by PEF

  • Abad, V.
  • Ruíz, A.
  • Grasa, J.
  • Calvo, B.
  • Escursell, N.
  • Peiro, T.
  • Raso, J.
  • Cebrián, G.
  • Álvarez-Lanzarote, I.
Pulsed Electric Fields (PEF) have proven effective in inactivating Anisakis in fish fillets. One of the parameters conditioning the lethal efficacy of PEF is the electrical conductivity of the treatment medium in which the fish is immersed. However, the underlying cause of this increased efficacy remains unknown. It was hypothesized that the difference in electrical conductivity between fish cells and Anisakis larvae could influence the electric field applied to each cell type. As measuring cells' electric fields is difficult, the study adopted an alternative dual approach. First, based on the experimental data, a mathematical equation was developed to predict Anisakis inactivation in hake belly fillets within the study's parameter ranges (1–5 kV/cm, 10–40 kJ/kg, 7–30 μs pulse width, and 0.4–10 mS/cm). Additionally, an increase in electrical conductivity under the same PEF treatment was experimentally observed to result in a greater degree of parasite inactivation. To investigate this phenomenon, the numerical simulation strategy was employed to estimate the electric field strength affecting the elements in the treatment chamber. The results showed that as the electrical conductivity of the medium increased, the electric field strength in the parasite also increased, thus explaining the greater inactivation observed.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Comparative evaluation of the mechanical properties of amniotic membranes for corneal grafting: Effects of cryopreservation, lyophilization, and dehydration

  • Fantaci, B.
  • Calvo, B.
  • Mesa, A.M.
  • Ortillés, A.
In both human and veterinary ophthalmology, stromal to full-thickness corneal defects can be treated using several techniques that involve various biomaterials, which support healing while preserving vision. Among these, the amniotic membrane stands out due to its multifaceted biological properties, including anti-inflammatory, antimicrobial, and regenerative capabilities. Three main preservation methods (cryopreservation, dehydration, and lyophilization) have been developed to facilitate amniotic membrane clinical use. However, these methods may significantly alter its mechanical and structural integrity, which are critical for graft success. This study investigates the mechanical performance of bovine amniotic membranes for veterinary use, preserved using the above-mentioned techniques, by means of uniaxial tensile and inflation tests in a non-biological in vitro setting. Structural and chemical differences are also analyzed using scanning electron microscopy and energy-dispersive X-ray spectroscopy. Despite structural differences arose among the samples, these differences did not alter or worsen the structural resistance of the membranes. All samples withstood 5 inflation cycles of 200 mmHg without leaking.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Large-strain anisotropic behavior of meat during cooking: A finite element study

  • Grasa, Jorge
  • Teresi, Luciano
  • van der Sman, Ruud
This paper investigates the role of anisotropy in the deformation of meat during cooking, and how it influences transport properties such as diffusion and thermal conductivity. To address this multiphysics problem a Finite Element model was developed, coupling mass transfer of water with thermal energy transport and large-strain solid mechanics. To account for fiber directionality, an anisotropic constitutive model with swelling-driven deformation is implemented. Particular emphasis is given to the definition of the reference configuration. Numerical simulations reveal that fiber orientation significantly influences the local stretch and overall shape evolution during pan frying. The magnitude and anisotropy of the deformation are sensitive to the swelling parameters and the fiber stiffness. These findings offer insights into the physical origin of cooking-induced texture transformations in meat and provide a framework for modeling fibrous biological materials undergoing thermal and fluid-driven processes.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

FEM modeling of hamburger pan cooking: Fat content influence and neural network-based prediction of fat loss

  • Hernández-Alhambra, E.
  • Guiu, P.
  • Ferrer-Mairal, A.
  • Martínez, M.A.
  • Calvo, B.
  • Grasa, J.
  • Salvador, M.L.
In this study, we developed an improved contact-cooking model that incorporates variations in fat content and its retention capacity, aiming to accurately simulate products with different compositions. The proposed approach incorporates the structural heterogeneity of meat by distinguishing between muscle fibers and interstitial fluid, and simulates the transport of water and fat between these regions. The model also accounts for heat transfer and meat deformation, representing the tissue as a hyperelastic material. The computational framework was implemented for the pan-cooking of hamburgers with different fat contents (ranging from 3% to 24%) and periodic flipping during the process. To validate the model, cooking experiments were performed. Although increasing fat content did not significantly affect water loss or core temperature (p>0.05), it strongly influenced other critical aspects of cooking performance and product quality, such as surface temperature, fat loss, total cooking losses, and shrinkage. These changes are relevant because they impact texture and consumer perception. In addition, hamburgers with a higher fat content exhibited lower hardness, cohesiveness, gumminess, and chewiness. The model successfully predicted these trends, demonstrating its potential to capture fat-related effects beyond thermal behavior and enabling the use of model-generated data for the training, validation, and testing of a simple neural network to predict fat loss during the cooking of hamburgers with varying water, fat, and protein contents.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Corneal deformation mapping and FE-based strain analysis via digital image correlation: Biomechanical changes after CXL and laser refractive surgery

  • Fantaci, Benedetta
  • Frechilla, Alejandro
  • Frigelli, Matteo
  • Büchler, Philippe
  • Kling, Sabine
  • Calvo, Begoña
Accurate assessment of corneal mechanical properties is critical for understanding ocular biomechanics, predicting refractive surgery outcomes, and optimizing cross-linking (CXL) treatments. Conventional uniaxial tensile testing is limited by non-physiological boundary conditions and simplified stress distributions. Inflation testing more closely reproduces the in vivo stress state but has traditionally lacked spatially distributed deformation mapping. In this work, we present an integrated experimental–computational protocol combining inflation testing of freshly enucleated porcine eyes with high-resolution three-dimensional digital image correlation (3D-DIC). Fifteen corneas were analyzed across three cohorts: (i) de-epithelialized controls, (ii) CXL-treated (standard Dresden protocol), and (iii) anterior stromal ablation via femtosecond laser. Samples were subjected to controlled intraocular pressure (IOP) elevations up to 40 mmHg. The 3D-DIC approach provided dense, pointwise displacement and strain maps across the anterior surface, successfully quantifying the localized stiffening effects of CXL and the increased compliance induced by stromal ablation. The surface kinematics was post-processed using a membrane-theory formulation to resolve principal in-plane strains, from which a regional strain metric was derived for inverse modeling with a fully three-dimensional finite element model to estimate anisotropic hyperelastic parameters of porcine corneal tissue. Overall, the method establishes an end-to-end route from physiologic loading to regional surface strain quantification and constitutive parameter identification, enabling quantitative evaluation of treatment-induced biomechanical changes in the cornea.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Computational Assessment of Oxygen Availability and Shear Stress in Microfluidic Cell Culture Chambers for Optimized Cell Adhesion

  • Poursaberi, Mahdi
  • Hauke, Guillermo
  • Mousavi, S. Jamaleddin
  • Doweidar, Mohamed H.
Microfluidic cell culture systems provide controlled microscale environments for biomedical research; however, cell viability within closed microchambers depends on adequate oxygen availability during the adhesion phase and on the mechanical stresses generated after perfusion begins. Experimental characterization of oxygen depletion and local shear stress remains challenging due to the small dimensions involved and the complexity of transport phenomena. In this study, a computational framework was developed to assess oxygen transport and hydrodynamic shear stress in an SU-8-based microfluidic culture chamber. Oxygen diffusion and cellular consumption were first modeled under static conditions to determine cell survival time prior to perfusion. The influence of chamber height on oxygen availability was investigated, and an empirical correlation was derived to predict oxygen concentration as a function of chamber geometry. Subsequently, medium perfusion was introduced, and the resulting wall shear stresses acting on adhered cells were evaluated under different flow conditions. The simulations demonstrated that chamber height significantly affects oxygen depletion time, while both chamber geometry and flow rate influence the magnitude of wall shear stress. The proposed framework provides practical design guidelines for optimizing microfluidic culture systems, enabling adequate oxygen supply and physiologically compatible mechanical conditions while reducing reliance on extensive experimental testing.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Biomaterials and biomechanical design of distal weight-bearing implants: Computational modeling, biomaterial interfaces, and clinical translation

  • Mahdi, Muntadher Saleh
  • Takhakh, Ayad M.
  • Hamdy Doweidar, Mohamed
Distal Weight-Bearing Implants (DWBIs) represent a clinically emerging class of load-bearing medical devices in which biomaterial design, surface architecture, and biomechanical performance are tightly coupled. Their success depends not only on restoring distal support in transfemoral rehabilitation, but also on the ability of metallic, ceramic, and composite biomaterial interfaces to sustain cyclic loading while promoting durable bone-implant integration. However, distal support also changes bending moments, shear stresses, micromotion, coating durability, and biological demands at the bone–implant interface. This systematic review synthesizes DWBI concepts, geometry optimization, finite element analysis with gait-phase loading, Functionally Graded Materials (FGMs), graded Ti–HAp (hydroxyapatite) architectures, in-vivo osseointegration evidence, and clinical translation pathways. A quantitative trend analysis was performed on 34 direct-contribution papers and 32 empirical studies to assess trends, validation depth, and translation readiness. However, more than half of the empirical evidence remained at the bench or simulation level, while animal and human/clinical studies formed a smaller validation layer. HAp-centered surface or bulk material engineering represented a substantial share of the corpus; however, evidence for graded Ti–HAp/FGM architectures was derived predominantly from non-DWBI biomaterial and mechanistic analog studies, supporting mechanistic plausibility rather than DWBI-specific validation. Mechanistically, DWBI should be interpreted as an integrated biomaterial-mechanical system linking macro-geometry, metallic/ceramic surface architecture, graded Ti-HAp interfaces, gait-phase loading, tribology/corrosion behavior, in-vivo fixation, and clinical workflow. Translation will require patient-realistic loading conditions, validated finite element analysis workflows, device-level fatigue and coating-integrity testing, standardized in-vivo endpoints, harmonized rehabilitation protocols, and registry-supported clinical follow-up linking mechanical plausibility to durable biological fixation and patient-level benefit.