Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Effect of decentration, tilt and rotation on the optical quality of various toric intraocular lens designs: a numerical and experimental study

  • Pérez-Gracia, Jesús
  • Ares, Jorge
  • Ávila Gómez, Francisco Javier
  • Remón, Laura
Toric intraocular lenses (T-IOLs) may lose their optical quality if they are not correctly positioned inside the capsular bag once implanted. In this work, T-IOLs with cylinder powers of +1.50, +4.50 and +7.50 D and differing degrees of spherical aberration have been designed, manufactured and tested in vitro using a commercial optical bench that complies with the requirements of standard ISO 11979-2. Moreover, the effect of tilt and rotation on optical quality was assessed by means of numerical ray tracing on an astigmatic eye model, while the effect of decentration was evaluated numerically and experimentally.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Three-dimensional particle size and position measurement by linear complex amplitude Wiener filtering; 35473233

  • Gómez-Climente, M.
  • Lobera Salazar, J.
  • Arroyo de Grandes, M. P.
  • Palero Díaz, V.
Digital in-line holography (DIH) combined with a Wiener filter has been applied to measure particle size and position in the flow inside a capillary model, seeded with magnetic particles (3µm) and with solid opaque particles that simulated red and white cells. The proposed filtering process takes advantage of the linearity implicit in the numerical reconstruction of the object complex amplitude. A modified DIH set-up, with a tilted illumination beam, was used as it presents two main advantages: it solves the twin image issue associated to in-line holography and increases the out-of-plane resolution. Experiments show that the proposed method discriminates particles within a range from 3 to 30µm with a sensitivity of 0.5µm. © 2022 Optica Publishing Group under the terms of the Optica Open Access Publishing Agreement
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Sector-based Fresnel zone plate with extended depth of focus

  • Torcal-Milla, F.
  • Sanchez-Brea, L.
  • Gomez-Pedrero, J.
A Sector-based Fresnel zone plate consists of a binary diffractive lens composed of a mosaic of sectors of Fresnel zone plates with different focal distances. When these focal distances are linearly distributed within the sectors, dual focus is obtained. Besides, we explore the possibility to generate an extended depth-of-focus lens by using a cubic distribution of the focal distances assigned to the sectors and optimizing the weight factors given to the terms of the cubic polynomial. Finally, numerical simulations based on the Rayleigh-Sommerfeld approach are carried out and experimental verifications by using a Spatial Light Modulator are performed, showing high agreement. The proposed kind of zone plate has potential applications in different research fields such as microscopy, lithography, data storage, or imaging.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Theoretical analysis of optical bistability in a CW-pumped erbium-doped fiber laser

  • Martín, Juan Carlos
A theoretical model that allows numerical simulations of optical bistability phenomena in CW-pumped erbium-doped fiber lasers is presented. Results of the simulations match correctly with previous experimental data. In order to simulate this phenomenon, the population inversion and optical powers longitudinal distributions along the active fiber have been considered. If this fiber is long enough, it has been found that the transition between the non-lasing and the lasing states involves a dramatic redistribution of the population inversion along the active medium. This fact makes that non-lasing and lasing states constitute different enough initial conditions which determine different final responses to the same control parameter, that is to say, bistability. On the other hand, a theoretical justification is found for a previous experimental result which pointed out that the bistability range becomes reduced if an external signal is launched to the cavity. Finally, the bistability range width dependence on the active fiber length is analyzed.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Mach-Zehnder-based measurement of light emitting diodes temporal coherence

  • Torcal-Milla, F.
  • Lobera Salazar, J.
  • Lopez, A. M.
  • Palero, V.
  • Andres Gimeno, N.
  • Arroyo de Grandes, M. P.
Objectives: The main objective of this work is to validate a Mach-Zehnder based interferometric method to measure the temporal coherence length of broadband finite size light sources such as Light Emitting Diodes (LEDs), and give a qualitative value of the temporal coherence length of white LEDs, for which nor their spectral width neither their emission peak wavelength are clearly defined. Motivation: Low-coherence light sources such as LEDs have opened many possibilities in applications in which using lasers introduces coherent noise (speckle) that hinders the performance of interferometric measurement techniques. The coherence length is an important characteristic of light sources for scientific applications related to diffraction, holography, tomography, or interferometry. The spatial coherence of a source depends on the distance from the source to the observation plane and its size, while the temporal coherence is related to the emission spectral width and the emission peak wavelength. Therefore, the temporal coherence is a characteristic of each source. Methodology and results: In this work, we use a Mach-Zehnder interferometer for the first time to measure the coherence degree and the temporal coherence length of quasi-monochromatic LEDs. We validate the technique by comparing the results to those obtained directly from the spectrum. Then, we use the tested interferometric method to measure the temporal coherence length of a white LED, for which neither the width of the spectrum nor the emission peak wavelength, are clearly defined. In this case, the Wiener-Khinchin theorem is used to validate the interferometric technique. A very interesting property of the method is that the temporal coherence length is obtained from a single measurement, without needing to perform a scanning. This method can be used also for other non-coherent sources such as halogen lamps, pulsed lasers, and so on. The obtained results will improve the characterization of light sources and the applications dealing with physical optics and electromagnetic interference. © 2022 The Authors
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Contribution to the Improvement of the Correlation Filter Method for Modal Analysis with a Spatial Light Modulator

  • Benedicto, David
  • Collados, María Victoria
  • Martín, Juan C.
  • Atencia, Jesús
  • Mendoza-Yero, Omel
  • Vallés, Juan A.
Modal decomposition of light is essential to study its propagation properties in waveguides and photonic devices. Modal analysis can be carried out by implementing a computer-generated hologram acting as a match filter in a spatial light modulator. In this work, a series of aspects to be taken into account in order to get the most out of this method are presented, aiming to provide useful operational procedures. First of all, a method for filter size adjustment based on the standard fiber LP-mode symmetry is presented. The influence of the mode normalization in the complex amplitude encoding-inherent noise is then investigated. Finally, a robust method to measure the phase difference between modes is proposed. These procedures are tested by wavefront reconstruction in a conventional few-mode fiber.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Design and numerical analysis of metallic Ronchi diffraction gratings acting as reflective beam-splitter

  • Torcal-Milla, Francisco Jose
  • Sanchez-Brea, Luis Miguel
Objective In this work, a reflective beam-splitter based on a metallic Ronchi diffraction grating normally illuminated is designed and analysed. This kind of beam-splitter could have potential applications in photonics and optical technologies in which robustness is necessary since it may be manufactured over malleable metallic substrates. Methods The main idea under the design is as simple as obligating the zero-th diffraction order to be null. Firstly, scalar approach is performed, showing an approximation to the parameters of the grating necessary to cancel zero-th diffraction order. After that, a more rigorous approach such as Rigorous Coupled Waves Analysis (TE and TM polarization) is used to evaluate the proposed diffraction gratings as reflective beam-splitters. Results Beam-splitting is demonstrated for TE and TM polarization with slightly different dimensional parameters of the diffraction grating. Besides, we show how physical height of the grating grooves that allows cancelling zero-th diffraction order for a certain illumination wavelength depends on the metals used to manufacture the grating and its period. The dependence of the grooves height on the period is exponentially decreasing. To complete the analysis, we demonstrate how for a given grating period, the grooves height also depends on the illumination wavelength.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Peripheral Refraction of Two Myopia Control Contact Lens Models in a Young Myopic Population

  • Marcellán, Maria Concepción
  • Ávila, Francisco J.
  • Ares, Jorge
  • Remón, Laura
Peripheral refraction can lead to the development of myopia. The aim of this study was to compare relative peripheral refraction (RPR) in the same cohort of uncorrected (WCL) and corrected eyes with two different soft contact lenses (CL) designed for myopia control, and to analyze RPR depending on the patient’s refraction. A total of 228 myopic eyes (114 healthy adult subjects) (−0.25 D to −10.00 D) were included. Open-field autorefraction was used to measure on- and off- axis refractions when uncorrected and corrected with the two CLs (dual focus (DF) and extended depth of focus (EDOF)). The RPR was measured every 10° out to 30° in a temporal-nasal orientation and analyzed as a component of the power vector (M). The average RPR for all subjects was hyperopic when WCL and when corrected with EDOF CL design, but changed to a myopic RPR when corrected with DF design. Significant differences were found between RPR curves with both CLs in all the eccentricities (Bonferroni correction p < 0.008, except 10°N). An incremental relationship between relative peripheral refraction at 30 degrees and myopia level was found. It is concluded that the two CLs work differently at the periphery in order to achieve myopia control.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Propagation Losses Estimation in a Cationic-Network-Based Hydrogel Waveguide

  • Pons, Carolina
  • Galindo, Josué M.
  • Martín, Juan C.
  • Torres-Moya, Iván
  • Merino, Sonia
  • Herrero, M. Antonia
  • Vázquez, Ester
  • Prieto, Pilar
  • Vallés, Juan A.
A method based on the photographic recording of the power distribution laterally diffused by cationic-network (CN) hydrogel waveguides is first checked against the well-established cut-back method and then used to determine the different contributions to optical power attenuation along the hydrogel-based waveguide. Absorption and scattering loss coefficients are determined for 450 nm, 532 nm and 633 nm excitation. The excellent optical loss values obtained (0.32–1.95 dB/cm), similar to others previously described, indicate their potential application as waveguides in different fields, including soft robotic and light-based therapies.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Guiding losses estimation in hydrogel-based waveguides

  • Pons, Carolina
  • Galindo, Josué M.
  • Martín, Juan Carlos
  • Torres-Moya, Iván
  • Merino, Sonia
  • Herrero, María Antonia
  • Vázquez, Ester
  • Prieto, Pilar
  • Vallés, Juan Antonio
A method based on the photographic recording of the power distribution laterally diffused by cationic electroactive network (CN)-based hydrogel waveguides is first checked against the well-established cut-back method and then used to determine the different contributions to the optical power attenuation along the hydrogel-based waveguide. Absorption and scattering loss coefficients are determined for 450 nm, 532 nm and 633 nm excitation.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Optical quality variation of different intraocular lens designs in a model eye: lens placed correctly and in an upside-down position

  • Lacort, M.
  • Pérez-Gracia, J.
  • Ares, J.
  • Remón, L.
Introduction: Intraocular lenses (IOLs) may lose their optical quality if they are not correctly placed inside the capsular bag once implanted. One possible malpositioning of the IOL could be the implantation in an upside-down position. In this work, three aspheric IOLs with different spherical aberration (SA) have been designed and numerically tested to analyse the optical quality variation with the IOL flip, and misalignments, using a theoretical model eye. Methods: Using the commercial optical design software OSLO, the effect of decentration and tilt was evaluated by numerical ray tracing in two conditions: IOL in their designed position and flipped. The Atchison theoretical model eye used. Seven IOL designs of +27.00 diopters were used: a lens with negative SA to correct the corneal SA, a lens to partially correct the corneal SA and a lens to not add any SA to the cornea (aberration-free IOL). These lenses were designed with the aspherical surface located on the anterior and posterior IOL surface. A lens with no aspherical surfaces was also included. For the optical quality analysis, the Modulation Transfer Function (MTF) and Zernike wavefront aberration coefficients of defocus, astigmatism and primary coma were used. Results: Off-centering and tilting the IOL reduced overall MTF values, and increased wavefront aberration errors. With the IOL correctly positioned within the capsular bag, an aberration-free IOL is the best choice for maintaining optical quality. When the IOL is flipped inside the capsular bag the optical quality changes, with the aberration-free IOL and the IOL without aspheric surfaces providing the worst results. With the lens in an upside-down position, an IOL design to partially correct corneal SA shows the best optical quality results in decentration and tilt. Conclusion: The aberration-free IOL is the best choice when minimal postoperative errors of decentration or tilt are predicted. With IOL flip, the negative SA lens design is the best choice, regarding the root mean square wavefront aberrations. However, in a proper IOL implantation, the IOL designed to partially compensate the corneal SA including asphericity on its posterior surface is the better possible option, even in the presence of decentration or tilt.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Holographic sensor based on Bayfol HX200 commercial photopolymer for ethanol and acetic acid detection

  • Potarniche, Ioana-Adriana
  • Marín-Sáez, Julia
  • Collados, M. Victoria
  • Atencia, Jesús
This paper presents a holographic sensor based on reflection holograms recorded in the commercial photopolymer Bayfol® HX 200. The recording geometry and index modulation of the hologram were optimised to improve accuracy for this specific application. The sensor was subjected to tests using various analytes, and it exhibited sensitivity to acetic acid and ethanol. The measurements revealed a correlation between the concentration of the analyte in contact with the sensor’s surface and the resulting wavelength shift of the diffracted light. The minimum detectable concentrations were determined to be above 0.09 mol/dm3 for acetic acid and 5% (v/v) for ethanol. Notably, the sensors demonstrated a rapid response time. Given that ethanol serves as a base for alcoholic beverages, and acetic acid is commonly found in commercial vinegar, these sensors hold promise for applications in food quality control.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

A simple approach to the suppression of the Gibbs phenomenon in diffractive numerical calculations

  • Torcal-Milla F.J.
The Gibbs phenomenon is a well-known effect that is produced at discontinuities of a function represented by the Fourier expansion when it is truncated to perform numerical calculations. This phenomenon appears because it is not possible to fit a discontinuous function as the summation of continuous functions, such as it is done with the Fourier expansion. Only considering infinite terms of the summation, the Fourier expansion fits the real signal. From a general point of view, it will affect to the final results since the representation of the signal does not include higher frequencies. It is true that the higher is the truncation, the better are the results, but an error is always committed. The Gibbs phenomenon has been studied in electric signal and diffractive optics, where the Fourier expansion is commonly used. In this work, we drop complex mathematics to show the effect of the Gibbs phenomenon on the near field propagation of diffraction gratings (self-imaging phenomenon) and also possible implementations of some corrections which allow diminishing the analytical or numerical errors in comparison with less accurate approaches. Anyway, the conclusions of this work would be applicable to other numerically solved diffractive problems which include sharp edges apertures. Simulations are compared with experiments giving interesting results. © 2021 Elsevier GmbH
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Converging through the window

  • Torcal-Milla, Francisco José
Winter usually invites everybody to sit down in a comfortable armchair and enjoy the heat coming from a stove or the sunlight passing through the window. The glass of windows is commonly smooth, and the light passes through it without appearing to deviate from its path.1 It is refracted going into the glass but is refracted again as it leaves, so that it leaves the glass in the same direction as it arrived...
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

A diffraction experiment at the near field: the homemade Talbot effect

  • Torcal Milla, Francisco José
Diffraction refers to a kind of optical phenomena which occurs when light approaches an element (object or aperture) whose features are in the range of the illuminating wavelength (small apertures, sharp edges). It can be explained by means of the undulatory nature of light or also geometrically by using simple ray optics. Diffraction phenomena are impressive and not intuitive, so it makes them very interesting to bring examples to the classroom. The most popular diffraction experiments show effects in Fraunhofer regime, that is to be said, far from the diffractive object. Common examples are the single or double slit experiments. In this manuscript, we propose and show a less common diffractive effect that occurs in the Fresnel regime, near to the diffractive object. It is the Talbot effect or self-imaging phenomenon, which appears by illuminating a diffraction grating with a collimated monochromatic beam. It consists of the apparition of replicas (self-images) of the grating intensity pattern at periodic distances, multiples of the so-called Talbot distance. We show how this effect may be shown into the classroom with cheap and easy to find elements. In addition, we take advantage of its dependence on the coherence degree of the source to introduce the concept of optical coherence and show its effect on the contrast of the Talbot self-images. These experiments could be appropriate for undergraduate students or introductory physics courses.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Contribución de congreso (ConferenceOutput)

Oscillation period of the truncated simple pendulum

  • Torcal-Milla, Francisco Jose
In this manuscript, a non typical kind of simple pendulum called Truncated Simple Pendulum is analysed to obtain its oscillation period, frequency, and angular frequency. It is easily derived that its motion can be viewed as the concatenation of two pendular movements with different lengths, contributing each one to half of the period of the complete oscillation. An analytical formulation is derived and corroborated with an experiment showing high agreement. This experiment could be interesting as a proposed exercise for the students or as a laboratory practical work. Besides, the gravity acceleration can be determined from each singular experiment and averaged to obtain it with lesser experimental error. In addition, it can be used to evaluate energy conservation theorem and small angle approximation (Law of isochronism) for the pendular oscillation. The level of the manuscript makes it appropriate for undergraduate students and introductory physics courses.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Modified Mach–Zehnder interferometer for spatial coherence measurement

  • Torcal-Milla, F. J.
  • Lobera, J.
  • Roche, E. M.
  • Lopez, A. M.
  • Palero, V.
  • Andres, N.
  • Arroyo, M. P.
Spatial coherence of light sources is usually obtained by using the classical Young’s interferometer. Although the original experiment was improved upon in successive works, some drawbacks still remain. For example, several pairs of points must be used to obtain the complex coherence degree (normalized first-order correlation function) of the source. In this work, a modified Mach–Zehnder interferometer which includes a pair of lenses and is able to measure the spatial coherence degree is presented. With this modified Mach–Zehnder interferometer, it is possible to measure the full 4D spatial coherence function by displacing the incoming beam laterally. To test it, we have measured only a 2D projection (zero shear) of the 4D spatial coherence, which is enough to characterize some types of sources. The setup has no movable parts, making it robust and portable. To test it, the two-dimensional spatial coherence of a high-speed laser with two cavities was measured for different pulse energy values. We observe from the experimental measurements that the complex degree of coherence changes with the selected output energy. Both laser cavities seem to have similar complex coherence degrees for the maximum energy, although it is not symmetrical. Thus, this analysis will allow us to determine the best configuration of the double-cavity laser for interferometric applications. Furthermore, the proposed approach can be applied to any other light sources.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Modeling optical amplification in Er/Yb-codoped integrated Bragg gratings

  • Sanz-Felipe, Ángel
  • Ariza, Rocío
  • Benedicto, David
  • Macias-Montero, Manuel
  • Vallés, Juan A.
  • Solís, Javier
Bragg gratings inscribed in active waveguides combine very efficient reflective properties with the amplifying capability of rare-earths, which may lead to large amplification and lasing performance. However, the response of these photonic structures highly depends on the grating parameters and working conditions, so modeling their behavior and dependences becomes fundamental. In this work, a numerical method has been implemented to simulate the optical power propagation along an Er/Yb-codoped integrated waveguide Bragg grating as a function of its most relevant operational parameters. The results obtained show the optimal conditions to maximize its performance as a highly amplifying reflector, but also its capability as a monolithic laser. In addition, the modeling results adequately match experimental values measured in fs-laser written structures in Er/Yb-codoped phosphate glass, supporting the accuracy of the numerical method developed and its usefulness for further optimizing these promising photonic structures.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Peripheral refraction under different levels of illuminance

  • Marcellán Vidosa, María Concepción
  • Remón, Laura
  • Ávila, Francisco J.
Peripheral refraction is believed to be involved in the development of myopia. The aim of this study was to compare the relative peripheral refraction (RPR) at four different levels of illuminance, ranging from photopic conditions to complete darkness, using an open‐field autorefraction method. The RPR was calculated for each eccentricity by subtracting central from peripheral autorefraction measurements. The study included 114 myopic eyes from 114 subjects (mean age of 21.81 ± 1.91 years) and the mean difference in RPR between scotopic and photopic conditions (0 and 300 lux, respectively) was +0.32 D at 30° temporal and +0.37 D at 30° in the nasal visual field (NVF). Statistically significant differences were observed between 0 and 300 lux at 30° in the temporal visual field and at 30° and 20° in the NVF. Our results revealed a significant increase in relative peripheral hyperopia with increasing visual field eccentricity along the horizontal visual field in myopic eyes of young adults. Furthermore, this relative peripheral hyperopia increased as illumination decreased. These findings suggest that an increase in peripheral illuminance may protect against myopic eye growth.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Using clinical optical coherence tomography to characterise contact lens edge shape and base curve radius

  • Otin Mallada, Sofia
  • Gargallo Yebra, Diana
  • Tolón Zardoya, Nerea
  • Ares García, Jorge
Clinical relevance: Clinical optical coherence tomography devices are widely used in optometry and ophthalmology and may be used to measure contact lens base curvature radius and visualise contact lens edge shape. Background: Knowledge of contact lens geometry facilitates fitting, while optical coherence tomography provides a powerful means of measuring geometrical form. This study evaluates the performance of a clinical optical coherence tomography device (3D OCT-1000) in characterising contact lens edge shape and measuring the back optic zone radius of rigid gas-permeable contact lenses in vitro. Methods: First, an opto-mechanical optical coherence tomography contact lens adaptor was designed and 3D-printed to facilitate a contact lens being imaged using a commercial optical coherence tomography device. Second, several image-processing algorithms and a simple calibration method were developed to measure the back optic zone radius in optical coherence tomography B-scans. Finally, based on the findings of two experiments, B-scan performance was evaluated in terms of 1) capacity to differentiate between contact lens edge geometries, and 2) capacity to obtain accurate and repeatable back optic zone radius measurements. Statistical and graphical analyses were performed to characterise reliability and reproducibility. Results: The 3D OCT-1000 and adaptor combination was capable of acquiring images of sufficient quality to discriminate between soft and rigid contact lens edge geometries. Additionally, statistical analysis of the rigid contact lens measurements demonstrated satisfactory back optic zone radius measurement accuracy and reproducibility. Conclusion: This study demonstrates that a 3D OCT-1000 fitted with an opto-mechanical adaptor combination can be used to assess contact lens edges in vitro and that this clinical optical coherence tomography device, combined with image processing and linear calibration of the B-scans, is capable of obtaining back optic zone radius measurements of rigid gas-permeable contact lenses that are close to the ISO 18,369-2:2018 manufacturing tolerance range (±0.05 mm).
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Characterization of Multicore Integrated Active Waveguides Written in an Er3+/Yb3+Codoped Phosphate Glass

  • Benedicto D.
  • DIas A.
  • Martin J.
  • Valles J.-A.
  • Solis J.
A new methodology to completely characterize active multicore waveguides is proposed. The method is applied to two-core waveguides written in an Er3+/Yb3+ co-doped phosphate glass by femtosecond laser inscription. Determination of the core diameter and refractive index variation is based on asymmetric excitation of the dual core waveguide and measurements of the intensity output distribution. Moreover, a single core waveguide has also been written for characterization purposes and signal enhancement measurements carried out on it have allowed the determination of the glass active properties. Finally, enhancement measurements on the two-core waveguides for different pump powers and core-to-core separations have been performed, together with simulations of the experiments using the parameters determined in the characterization procedure. The good agreement between measurements and simulations supports the validity of the characterization method presented. The proposed characterization technique is suitable for any multicore symmetric structure regardless the fabrication method and the number of cores, allowing the benefits of multi-core fibre designs to be transferred to integrated active structures.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Characterization of asymmetrically Fed Er3+/Yb3+ Co-Doped double core integrated waveguides

  • Benedicto, David
  • Valles, Juan A.
  • Martin, Juan C.
The output signal intensity distribution of several fs-laser written double-core active waveguides was registered. The ratio between cores output powers exhibited a strong dependence on the input pump power when both input pump and signal powers were directly coupled to one of the cores. A model based on the coupled-mode theory which incorporates non-identical cores and longitudinally variable signal gain coefficients was implemented. Simulations based on this model are compared to experiments. A good agreement is achievable if small differences between cores’ parameters (within the manufacturing precision limits) are allowed. IEEE
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

A feasibility study of 3D printing technology for simulating rigid gas permeable contact lens fitting

  • Tolón Zardoya, Nerea
  • Gargallo Yebra, Diana
  • Ávila Gómez, Francisco J.
  • Ares García, Jorge
Purpose: To assess the feasibility of a novel method for simulating a Rigid Gas Permeable Contact Lenses (RGP-CL) fitting using 3-D printed sclero-corneal surfaces (SCSs). Methods: The experiment involved the fabrication of two resin SCSs with biconic corneal geometry and the participation of 22 optician-optometrists as observers. Participants compared the fluorescein patterns of three RGP-CL fitted on each SCS with theoretical patterns generated through computer simulation. To standardize visualization, comparisons were conducted through a multiple-choice questionnaire composed of 6 questions. Each question presented one main fluorescein pattern (either theoretical or experimental) and four additional patterns obtained using the other technique. Optometrists were required to select the fluorescein pattern more similar to the main pattern. A statistical analysis was performed to evaluate the accuracy of the comparison between the two methods. Results: The surface quality of the printed SCSs was sufficient to produce consistent and interpretable fluorescein patterns. In all questions, at least 70 % of optometrists selected the correct pattern. In four questions, more than 90 % identified the correct pattern, and in one question accuracy reached 100 %. The correct option was always the most frequently chosen, with a significantly higher rate than the second most selected option (p = 0.05). Conclusions: The ability of most optometrists to correctly identify patterns suggests that, even without polishing, 3-D printed SCSs can simulate fluorescein patterns closely resembling theoretical ones. This approach shows promise as a supportive tool for training in RGP-CL fitting.