Pasar al contenido principal

TECNOLOGIAS FOTONICAS APLICADAS PARA LA COMPENSACION Y DIAGNOSTICO OCULAR

DPI2016-75272-R

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos I+D+i Retos de Investigación
Año convocatoria 2016
Plan Estatal 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDAD COMPLUTENSE DE MADRID

Resultados relacionados

Resultados totales (Incluyendo duplicados): 6
Encontrada(s) 1 página(s)

Docta Complutense
Publicación Artículo científico (JournalArticle)

Machine learning techniques in the diagnosis of meibomian glands related alterations from clinical indicators

  • Fernández Jimenez, Elena
  • Diz Arias, Elena
  • Gómez Pedrero, José Antonio
  • Peral Cerda, María Asunción
Purpose: There is no "Gold Standard" test that allows the diagnosis and classification of alterations and pathologies related to Meibomian glands (MG). A global evaluation of objective and subjective tests is necessary to determine the final diagnosis. In recent years, Artificial Intelligence (AI) and Machine Learning (ML) techniques have experienced great progress in the field of health sciences, as promising techniques for predicting pathologies from data and images. The main objective of this study has been to train ML classifiers for the classification of three groups of participants with and without MG alterations. The secondary objective was to study the precision, specificity and sensitivity of the ML classifiers. Methods: A retrospective comparative study was carried out on a total of 135 participants (control, contact lens wearers and MG pathology). Symptomatology and clinical tests were performed to evaluate the ocular surface and adnexa. The numerical data obtained from these tests were used to train ML classifiers and the top 5 were subsequently verified. Results: Accuracies greater than 76 % were obtained for the training group and greater than 79 % for the verification group, for five classifiers previously described in Matlab. Subspace KNN was the classifier with the highest accuracies, specificities and sensitivities, these being moderate-high (greater than 79 %). Conclusions: ML algorithms can be useful for classifying groups of participants with various meibomian gland disorders using clinical data. A large number of participants is needed for reliable diagnostic accuracy.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Single-focus binary Fresnel zone plate

  • Torcal Milla, Francisco José
  • Sanchez-Brea, Luis Miguel,
In this work, we propose and analyze a novel kind of binary Fresnel zone plate with single focus. It consists of a Fresnel zone plate whose zones have rough edges. We give analytical results for the intensity along the optical axis and demonstrate that lateral roughness of the zones produces the disappearance of secondary foci as a blurring of the edges. Besides, we corroborate its behavior by numerical simulations and experiments. This kind of Fresnel zone plate can be useful in a wide range of photonic applications, even for focusing with soft and hard X-rays or extreme ultraviolet radiation.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Numerical model of the inhomogeneous scattering by the human lens

  • Cuadrado, A.
  • Sanchez-Brea, L.M.
  • Torcal-Milla, F.J.
  • Quiroga, J.A.
  • Gomez-Pedrero, J.A.
We present in this work a numerical model for characterizing the scattering properties of the human lens. After analyzing the scattering properties of two main scattering particles actually described in the literature through FEM (finite element method) simulations, we have modified a Monte Carlo''s bulk scattering algorithm for computing ray scattering in non-sequential ray tracing. We have implemented this ray scattering algorithm in a layered model of the human lens in order to calculate the scattering properties of the whole lens. We have tested our algorithm by simulating the classic experiment carried out by Van der Berg et al for measuring "in vitro" the angular distribution of forward scattered light by the human lens. The results show the ability of our model to simulate accurately the scattering properties of the human lens. (C) 2019 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Sector-based Fresnel zone plate with extended depth of focus

  • Torcal-Milla, F.
  • Sanchez-Brea, L.
  • Gomez-Pedrero, J.
A Sector-based Fresnel zone plate consists of a binary diffractive lens composed of a mosaic of sectors of Fresnel zone plates with different focal distances. When these focal distances are linearly distributed within the sectors, dual focus is obtained. Besides, we explore the possibility to generate an extended depth-of-focus lens by using a cubic distribution of the focal distances assigned to the sectors and optimizing the weight factors given to the terms of the cubic polynomial. Finally, numerical simulations based on the Rayleigh-Sommerfeld approach are carried out and experimental verifications by using a Spatial Light Modulator are performed, showing high agreement. The proposed kind of zone plate has potential applications in different research fields such as microscopy, lithography, data storage, or imaging.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Far field diffraction of gratings with two roughness levels

  • Torcal-Milla, F.J.
  • Sanchez-Brea, L.M.
We investigate the far field diffraction process produced by diffraction gratings with two roughness levels, such as steel tape gratings, which are used in environments where diffraction gratings made of glass are not possible. We obtain the analytical formulation describing the formation of diffraction orders in terms of the roughness parameters. Since roughness is stochastic, we use the mutual coherence function to propagate the field to the Fraunhofer regime. We conclude that diffraction orders exists when at least one correlation length of both roughness is larger than the period of the grating and the standard deviation on heights is around or larger than the illumination wavelength. Finally, we corroborate the analytical results with numerical simulations based on the fast Fourier transform, showing a high agreement.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Optimization of angular diffractive lenses with extended depth of focus

  • Sanchez-Brea, L.M.
  • Torcal-Milla, F.J.
  • Del Hoyo, J.
  • Cuadrado, A.
  • Gomez-Pedrero, J.A.
Conventional refractive lenses concentrate the incident light at focal distance. A narrow beam waist can be achieved by increasing the lens numerical aperture, but strongly reduces the depth of focus. In this work, we explore diffractive lenses designs, with fast angular variation of the focal distance, that produce both a narrow beam waist and a long depth of focus. We predict the focusing properties of the diffractive lenses with a simple analytical model based on an incoherent superposition of standard lenses with different focal distances. The histogram of the local focal distances is used to determine the weights in the superposition. Our model optimizes the shape of the diffractive lenses, in order to extend the depth of focus, which corresponds to the lotus lens. We verify our results with numerical simulations based on Rayleigh-Sommerfeld approach. Experimentally, we validate our analytical and numerical solutions with a spatial light modulator. We have found configurations for the lotus lens where the depth of focus is significantly incremented with only a slight increment of the focal width. For example, we increased the depth of focus from 7.6 mm to 37.2 mm while the beam waist varied from 35.0 microns to 51.6 microns for a lens with diameter D = 4 mm, and focal distance f'' = 125 mm. These results may find applications in the design of contact and intraocular lenses with extended depth of focus, laser focus generators, and imaging applications where extended depth of focus is needed.